Micromark MM23052 Manual

INSTALLATION & OPERATING INSTRUCTIONS
IIMMPPOORRTTAANNTT::PPLLEEAASSEERREEAADDTTHHEESSEEIINNSSTTRRUUCCTTIIOONNSSCCAARREEFFUULLLLYYBBEEFFOORREEAATTTTEEMMPPTTIINNGGTTOOIINNSSTTAALLLLTTHHIISSAALLAARRMMSSYYSSTTEEMM..
IIFFTTHHEESSYYSSTTEEMMIISSBBEEIINNGGIINNSSTTAALLLLEEDDBBYYAASSEECCUURRIITTYYIINNSSTTAALLLLEERROORREELLEECCTTRRIICCAALLEENNGGIINNEEEERR,,PPLLEEAASSEEEENNSSUURREETTHHAATTAA
CCOOPPYYOOFFTTHHEESSEEIINNSSTTRRUUCCTTIIOONNSSIISSGGIIVVEENNTTOOTTHHEECCUUSSTTOOMMEERRFFOORRRREETTEENNTTIIOONNAANNDDFFUUTTUURREERREEFFEERREENNCCEE..
This alarm system can provide valuable protection for your home and property if used properly. However, the system
cannot guarantee complete protection against burglary or robbery. Therefore, the manufacturer, distributor or supplier will
not be held responsible for any loss or damage which may occur.
2-ZONE EASYFIT INTRUDER ALARM
Check the contents of the
packaging:
• 2-zone control panel
• External siren
• Mains adaptor
• 1 PIR sensor
• 1 set of hardwired door
contacts
• 4 sticky pads
• Fixing screws
• Cable clips
• Wall plugs
• 30m of multi-core alarm
cable
• Fixing bracket
IMPORTANT
In certain areas of the country you are required by law to
notify the Police and Local Authority when you install an
Alarm System. Since the requirements of each Authority
differ, we suggest that you contact the Environmental Officer
of your local Borough for full information about your local
area‘s by-laws.
CCOONNTTEENNTTSS
Planning your system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Start with installing the control panel and siren . . . . . . . . . . . . .4
Fitting the PIRs and door contacts . . . . . . . . . . . . . . . . . . . . . . . .6
Wiring the control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Checking the system – Walk test . . . . . . . . . . . . . . . . . . . . . . . . .8
Total immobilisation of system . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Checking the system – Bell test mode . . . . . . . . . . . . . . . . . . . . .8
System entry time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
System exit time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Bell reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
To change password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
To arm the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
To disarm the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Chime zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .back cover
KKIITTCCOONNTTEENNTTSS
Please note that this equipment and its components have NO user serviceable parts.
If you experience any difficulties call our Helpline.
MMIICCRROOMMAARRKKHHEELLPPLLIINNEETTEELL::0088770022441133002299
Monday to Friday (8.30am to 5pm)
www.micromark.co.uk
PPlleeaasseennoottee::BBeeffoorreeyyoouussttaarrttttooiinnssttaalllltthhiissMMiiccrroommaarrkkAAllaarrmm,,wweeaaddvviisseetthhaattyyoouusshhoouullddttaakkeeaaddeeqquuaatteessaaffeettyypprreeccaauuttiioonnss
wwhheennuussiinnggppoowweerrttoooollssaannddllaaddddeerrss..PPrrootteeccttyyoouurreeyyeesswwhheennddrriilllliinnggaannddnneevveerruusseeaapppplliiaanncceessiinnddaammppoorrwweettccoonnddiittiioonnss..
CONTROL PANEL
EXTERNAL SIREN
PIR SENSOR
MAINS ADAPTOR
ALARM CABLE
FIXING BRACKET
DOOR
CONTACTS
MMMM2233005522
ukpanels.com

WWHHAATTIISSAAZZOONNEE??
Throughout these instructions the term ZONE is used, meaning a defined area of protection. A zone can be one room, or any number of rooms,
connected to the same connection on the control panel. With this system there are 2 areas you can guard and a 24-hour anti-tamper guard.
The PIR detects movement of people or animals in the detection zone. Door contacts can be used to detect door or window entry in either zone. See the
diagram to help you plan your system.
IIMMPPOORRTTAANNTTPPOOIINNTTSSTTOO
CCOONNSSIIDDEERR
When planning your system and
before installation consider the
following points:
• TThhiissssyysstteemmiissddeessiiggnneeddttoouussee
oonnllyy11PPIIRRppeerrzzoonnee..
• Make zone 1 the Entry/Exit zone.
• Do not position PIRs facing
windows, in direct sunlight, above
a heat source such as radiator, or
in conservatories or draughty
areas.
• Where possible keep pets out of
areas protected by PIR sensors
when armed.
• Position control panel near a
power socket.
NNoottee::This alarm must only be
used when powered by the mains
adaptor, the internal battery
operates as a stabilizing back up
supply in the event of short periods
of power loss, and will not run the
system over a long period.
In the event of an activation during
a power loss period all of the zone
LEDs will illuminate when you
disarm the system. You will have to
reset the system using your
personal security code.
2
PLANNING YOUR SYSTEM ACCESSORIES
MMMM99445522
SSuurrffaacceemmaaggnneettiiccddoooorr
ccoonnttaaccttss..
2 terminal single reed.
White high impact
plastic. 4 fixing screws
and 2 adhesive pads
included.
MMMM2233004477
PPIIRRsseennssoorr
8 metre range,
3 terminal
connections
SSiirreennccoovveerrss
MMMM99445555
’C’ type. White
polypropylene
MMMM99446611
’C’ type. Yellow
polypropylene
MMMM99445533--44ccoorreeaallaarrmm
ccaabbllee
30m alarm cable. NNoottffoorr
uusseewwiitthhmmaaiinnssvvoollttaaggee..
White sheath, 4 core
(red/black/blue/yellow).
NNoottee::ddiissrreeggaarrddtthheebblluuee
wwiirreeoonntthhiisskkiitt..
MMMM99445544--3300ccaabblleecclliippss
3.5mm flat. White
Extra door contacts can be
used with and without PIRs.
Extra door contacts are
available as accessories.
SSIIRREENN
ZZOONNEE11
Use this as your entry/exit
zone. Door contacts.
ZZOONNEE22
PIR and/or door
contacts.
We suggest that outside
doors are protected by a
door contact, as 71% of
entries are made through a
door.
Home Office statistics, Jan.
2001.
CCOONNTTRROOLL
PPAANNEELL
ukpanels.com

3
WIRING DIAGRAMS
TYPICAL WIRING DIAGRAM SHOWING PIR IN ZONE 2 AND DOOR CONTACTS IN ZONE 1 (THE ENTRY/EXIT ZONE)
ZONE 2 ZONE 1
WIRING DIAGRAM SHOWING PIR AND DOOR CONTACTS
WIRED ON ONE CABLE RUN TO CONTROL PANEL IN THE
SAME ZONE
TRIM RED
WIRE BACK
TO
INSULATION
AND COVER
WITH TAPE
TRIM RED WIRES BACK TO
INSULATION AND COVER
WITH TAPE
TERMINAL BLOCK
BLACK WIRES TWISTED
AND TAPED TOGETHER
BLACK WIRES TWISTED
AND TAPED TOGETHER
RED WIRES
TWISTED
AND
TAPED
TOGETHER
3-WAY
TERMINAL
BLOCK
FROM CONTROL
PANEL
FROM
CONTROL
PANEL
DOOR
CONTACTS
BATTERY
COMPARTMENT
SNAP CONNECTOR
DOOR CONTACTS
PIR
MAINS
ADAPTOR
PIR
SIREN
CONTROL PANEL
ANTI-TAMPER SWITCH
WIRING DIAGRAM SHOWING ADDING AN EXTRA
CONTACT TO AN EXISTING DOOR CONTACT
ZZOONNEE11
ZZOONNEE22
TRIM RED
WIRE BACK
TO
INSULATION
AND COVER
WITH TAPE
ukpanels.com

4
START WITH INSTALLING THE CONTROL PANEL AND SIREN
Position the control panel near a mains socket and
within easy reach of the entry/exit door.
Before drilling holes, ensure that they are not near
hidden mains wiring and pipework.
When planning the wiring, avoid awkward cable runs
to the control panel, siren box, PIRs and door
contacts.
1
Install the control panel out of reach of young
children.
Mark for two vertical holes 60mm apart. Use a power drill with a no. 6 masonry drill bit, and
drill two holes 25mm deep. Insert the masonry plugs.
Mount the fixing bracket and secure with the fixing
screws.
456
2 3
60mm
ukpanels.com

5
Connect the connector from the control panel to the
connector on the end of the cable. Temporarily hang
the control panel on the bracket. Warning: Do not
power up the control panel yet.
7
Run the cable inside the property to the point of exit
where the the outside siren is to be installed. Drill a
hole through the inside wall to the outside and thread
through the cable to the outside. Use cable clips to
hold the cable near the exit hole.
8
Use a suitable platform to work from and use the
siren box as a template to mark the position for the
fixing screws. Drill holes 25mm deep and insert
masonry plugs.
9
Bring the cable to the position of the siren box and cut
the cable, allowing enough surplus for wiring into the
siren terminal block. Strip the wires and connect them
to the teminal block as shown.
Fix the siren to the wall with the 3 fixing screws and
wall plugs supplied. Start at the control panel and
secure the cable run with cable clips. Reserve some
clips for wiring the PIR and door contacts.
CHECK LIST
Have you planned the layout?
Is the control panel near a power socket?
Have you temporarily placed the control
panel on the fixing bracket?
Are the connector plugs connected?
Is the wiring to siren box completed?
Has the wiring been secured with cable clips?
11
wall
plugs
10
FFoolllloowwssaaffeettyypprreeccaauuttiioonnss
wwhheennuussiinnggllaaddddeerrss..
ukpanels.com

6
FITTING THE PIRs AND DOOR CONTACTS
Allow enough cable to reach the control panel.
Unscrew the fixing screw at the base of the PIR and
remove the front cover. Remove the knockout at the
base of the back casing. Strip the wires to bare the
ends.
1
Fit the door contact with the screws
with a gap of 5mm between the
leading edges. Fix the wireable
contact to the frame
4
Run the wiring to the door contacts
(see wiring diagrams). The picture
shows door contacts wired directly to
the control panel. Cut back the red
wire to the insulation and tape the
end.
5
Follow the same procedure for each of
the zones. At the control panel mark
the wwiirreesswwiitthhtthheezzoonneessffrroommwwhhiicchh
tthheeyyaarreeffrroomm..
6
Thread the stripped cable through and connect the
wires to the terminal block observing the colours.
Replace the cover and screw.
Use a sticky pad and secure the PIR to the mounting
surface. Run the cable back to the control panel
taking the shortest route and secure it with cable
clips.
2
CHECK LIST
Are PIRs wired correctly?
Are the PIRs securely mounted?
Is the gap between door contacts correct?
Are the door contacts wired correctly?
Are the wires marked with their zones?
3
ukpanels.com

7
WIRING THE CONTROL PANEL
Ensure that the mains adaptor from the control panel
is unplugged. During all wiring, panel must be
switched off.
1
Plug the mains adaptor jack plug into the socket on
the back of the control panel.
2
Take the labelled wires and connect them into their
respective zones marked on the terminal block, using
the folllowing code for the wiring:
Connect the red wires into the terminal marked + or
red.
Connect the black wires into the terminal marked – or
black.
Connect the yellow wires into the terminal marked
yellow.
3
Tape down the anti-tamper spring before connecting the
back-up battery (when the battery is connected the panel
produces a bleep), otherwise as soon as the back-up
battery is connected in the control panel, the anti-tamper
sounds. If the siren does sound then:-
PPrreessss11112222to disarm.
Open the battery compartment cover and fit a Duracell
PP3 9 volt alkaline battery (not supplied). Replacement
batteries must be of a Duracell alkaline type. Make sure
that terminals on the connector are connected to the
correct terminals on the battery. NNeevveerruusseerreecchhaarrggeeaabbllee
bbaatttteerriieess..
PPLLEEAASSEENNOOTTEE::
TToommaaiinnttaaiinnooppttiimmuummsseeccuurriittyy,,tthheebbaatttteerryy
sshhoouullddbbeecchheecckkeeddrreegguullaarrllyyaannddrreenneewweeddeevveerryyyyeeaarr..
4
Check all wiring connections are tight in the terminal
block. Remove the tape from the anti-tamper spring
and place the control panel on the mounting bracket.
TThheeaallaarrmmwwiillllssoouunnddwwhheenntthheesspprriinnggiissrreelleeaasseedd,,
uunnttiilltthheeccoonnttrroollppaanneellmmaakkeessaaffiirrmmffiittaaggaaiinnsstttthhee
bbrraacckkeettddeepprreessssiinnggtthheeaannttii--ttaammppeerrsspprriinngg..
The anti-tamper spring will ‘click’ when it is
depressed.
PPrreessss11112222to silence the alarm, then pprreessss11112222to
reset the panel.
5
CHECK LIST
Is mains adaptor unplugged at wall socket?
Have you plugged mains jack plug into
control panel?
Are red, black and yellow wires connected
to the correct terminals in control panel?
Is battery back-up in control panel?
Is control panel firmly attached to the bracket?
Is anti-tamper spring fully compressed?
If additional cable is required, use 4-core alarm
cable (see accessories) and cut short the blue wire.
Anti-tamper spring
ukpanels.com

8
CHECKING THE SYSTEM – BELL TEST MODE
CHECKING THE SYSTEM – WALK TEST
In this mode you can test each zone without
the alarm sounding. The zones that you
enter or open will show on the control panel
by a flashing LED and a bleep sound.
PPrreessssPP11112222EEttooeenntteerrpprrooggrraammmmiinngg..
PPrreessssPP77EE
Open a door with a door contact fitted, or
enter an area where a PIR is fitted. The
control panel will bleep twice and the
Zone LED will illuminate.
Repeat the procedure for each zone to
check correct operation.
In this mode you can test the control panel
siren and the outside siren to hear them
working.
PPrreessssPP11112222EEttooeenntteerrpprrooggrraammmmiinngg..
PPrreessssPP00EEttooeennddtteesstt
The control panel returns to
programming mode with flashing
SYSTEM ARMED LED on Zone 1 and 2.
PPrreessssPP00EEaaggaaiinnttooeexxiittpprrooggrraammmmiinngg..
PPrreessssPP66EE
Zones 1 and 2 LEDs will flash with the control
panel siren and the outside siren sounding
for 15 seconds.
PPrreessssPP00EEttooeennddtteesstt
The internal buzzer will temporarily sound a
constant tone for 3 seconds.
The control panel returns to programming
mode with flashing STATUS LED.
PPrreessssPP00EEaaggaaiinnttooeexxiittpprrooggrraammmmiinngg..
12
123
3
Plug the adaptor from the control panel
into the mains socket and switch on.
The power LED on the control panel will
light showing that programming can
begin.
If for any reason the sirens sound,
pprreessss11112222to disarm.
TOTAL IMMOBILISATION
OF SYSTEM
Should it be necessary to totally
immobilise the system in the alarmed
state (e.g. forgotten you password):
aa..Unplug from mains.
bb..Remove control panel from fixing
bracket, and remove the back-up battery.
If you are unable to get the system to
reset, contact the Micromark Helpline.
TThheessttaattuussoofftthheerreeddPPOOWWEERRLLEEDDoonntthhee
ccoonnttrroollppaanneelliissaassffoolllloowwss::
OONNPower on
OOFFFFNo transformer supply
TThheemmeeaanniinnggoofftthheerreeddSSTTAATTUUSSLLEEDDoonn
tthheeccoonnttrroollppaanneelliissaassffoolllloowwss::
OONN24-hr fault, or reset
required
OOFFFFNormal
FFLLAASSHHIINNGGProgram mode
CONTROL PANEL STATUS
ukpanels.com

9
SYSTEM ENTRY TIME
Then PPrreessssPP22EEand within 5
seconds your choice.
((IIffyyoouuddoonnoottddeecciiddeewwiitthhiinn55
sseeccoonnddss,,tthhrreeeesshhoorrttbblleeeeppss
wwiillllbbeehheeaarrdd,,aannddyyoouuwwiillll
hhaavveettooeenntteerrPP22EEaannddssttaarrtt
aaggaaiinn..))
Then PPrreessssPP00EEto exit
programming.
123 4
Entry time is the period
of time allowed for you
to enter and disarm the
system with the
password (factory set to
1122), before the sirens
sound.
The entry time is set by
the factory to 20
seconds but this can be
changed from a choice
of 7 other entry times to
suit you.
If for any reason the
sirens sound, pprreessss
11112222to disarm.
PPrreessss33EEwhich is the
program for 40 seconds.
If entered correctly, a
continuous bleep will be
heard for 2 seconds.
For example, to change the
entry time to 40 seconds (see
choices in Table):
PPrreessssPP11112222EEttooeenntteerr
pprrooggrraammmmiinngg..
SYSTEM EXIT TIME
Exit time is the period of
time allowed for you to
exit after arming the
system with the
password, before the
sirens sound.
The exit time is set by
the factory to 15
seconds but this can be
changed from a choice
of 7 other exit times to
suit you.
If for any reason the
sirens sound, pprreessss
11112222to disarm.
1
For example, to change the
exit time to 60 seconds (see
choices in Table):
PPrreessssPP11112222EEttooeenntteerr
pprrooggrraammmmiinngg..
Then PPrreessssPP33EEand within 5
seconds your choice.
((IIffyyoouuddoonnoottddeecciiddeewwiitthhiinn55
sseeccoonnddss,,tthhrreeeesshhoorrttbblleeeeppss
wwiillllbbeehheeaarrdd,,aannddyyoouuwwiillll
hhaavveettooeenntteerrPP33EEaaggaaiinn..))
23
PPrreessss44EEwhich is the
program for 60 seconds.
If entered correctly, a
continuous bleep will be
heard for 2 seconds.
Then PPrreessssPP00EEto exit
programming.
4
Example:
Example:
To choose other entry times:
11EE10 seconds
00EE15 seconds
22EE20 seconds
33EE40 seconds
44EE60 seconds
55EE90 seconds
66EE120 seconds
77EE240 seconds
To choose other exit times:
11EE10 seconds
00EE15 seconds
22EE20 seconds
33EE40 seconds
44EE60 seconds
55EE90 seconds
66EE120 seconds
77EE240 seconds
ukpanels.com

10
BELL RESET
Then PPrreessssPP44EEand within 5
seconds your choice.
((IIffyyoouuddoonnoottddeecciiddeewwiitthhiinn55
sseeccoonnddss,,tthhrreeeesshhoorrttbblleeeeppss
wwiillllbbeehheeaarrddaannddyyoouuwwiillll
hhaavveettooeenntteerrPP44EEaannddssttaarrtt
aaggaaiinn..))
Then PPrreessssPP00EEttooeexxiitt
pprrooggrraammmmiinngg..
1
4
3
2
TO CHANGE PASSWORD
The panel comes factory set to a standard 4-digit password 11112222. This password code is the signal by
which the panel recognises a legitimate user, we recommend that you change this code to a 4-digit
password code of your own choosing. Each member of your family or household will have to know this
code and how to use it. To change the factory set code:
TTOOCCHHAANNGGEETTHHEEFFAACCTTOORRYYSSEETTCCOODDEE::
PPrreessssPP11112222EEttoo
eenntteerrpprrooggrraammiinngg..
31
EE
????
????
SETTING UP CHECK LIST
Have you done the walk test
Have you done the bell test?
Have you set your preferred entry time?
Have you set your preferred exit time?
Have you set your preferred bell reset time?
Have you changed your password?
2
After activation of the alarm system, the
external siren will stop after the
programmed time, but the internal siren
will beep slowly until the password has
been entered.
The bell reset time is set by the factory to
10 minutes but this can be changed from
a choice of 3 other times to suit you.
The bell reset test mode enables you to
re-program the length of time you wish
the siren to sound after it has been
activated. The legal maximum time under
current legislation is 20 minutes.
If for any reason the sirens sound,
pprreessss11112222to disarm.
For example, to change the
bell reset to 15 minutes (see
choices in Table):
PPrreessssPP11112222EEttooeenntteerr
pprrooggrraammmmiinngg..
PPrreessss33EEwhich is the
program for 15 minutes.
If entered correctly, a
continuous bleep will be
heard for 2 seconds.
PPrreessssPP11EE..
YYOOUUMMUUSSTTNNOOWWUUSSEETTHHEENNEEWWPPAASSSSWWOORRDDFFOORRAALLLLAACCTTIIOONNSS..
You have 10 seconds
to enter the new 4-
digit password plus EE.
After the keys are
pressed an
acceptance tone of 2
seconds duration will
be heard and then
reset back to zones 1
and 2 with flashing
LEDs.
PPrreessssPP00EEttooeexxiitt
pprrooggrraammmmiinngg..
Should the system
lose power, the
control panel
reverts to the
factory default
settings.
4
Example:
Choices are:
11EE5 minutes
22EE10 minutes
33EE15 minutes
44EE20 minutes
55EE1 minute
66EE2 minutes
77EE3 minutes
88EE4 minutes
ukpanels.com

TO ARM THE SYSTEM
TO DISARM THE SYSTEM CHIME
Full Guard means that you have placed
all of the zones covered by sensors into
the armed mode. Should you or an
intruder enter a zone covered by these
sensors the sirens will sound.
BBeeffoorreeyyoouuccaannaarrmmtthheessyysstteemm,,eennssuurree
tthhaattddoooorrssoorrwwiinnddoowwssccoovveerreeddbbyyddoooorr
ccoonnttaaccttssaarreecclloosseedd,,aannddtthhaatttthheezzoonnee
LLEEDDss11aanndd22oonntthheeccoonnttrroollppaanneellaarreennoott
iilllluummiinnaatteedd..
EEnntteerryyoouurrPPaasssswwoorrdd..
Exit the premises. A
continuous tone will
be heard from the
control panel followed
by 4 bleeps.
1
????
????
On re-entry, the control panel will bleep
fast until tthheeppaasssswwoorrddhhaassbbeeeenneenntteerreedd..If
it is not entered within the entry time, the
alarm will activate. When the password
has been entered the bleeps will stop and
the zone entered LED will be illuminated.
EEnntteerrppaasssswwoorrddaaggaaiinnttoorreesseett..
1
????
????
You can programme a zone to activate as a chime tone. This is useful if the system is not fully armed, but you need
to know of unauthorised entry in a particular zone. You can arm zone 1, zone 2 or cancel the chime.
1
1
EE
????
????
EE
PP
PP
????
????
2
Should you want to cancel arming, enter your
password again while the system is sounding the
exit time.
Note that each zone activated during the armed
period will be indicated by a corresponding LED on
the control panel when disarmed.
TThheessyysstteemmiissnnoottddeessiiggnneeddttooaarrmmiiff::
a) Tamper switch is not fully depressed.
b) Bell box is not connected correctly
c) A door or window with a contact has been left
open.
Check above and reset system pressing 11112222or your
password. The LED should extinguish.
EEnntteerryyoouurrPPaasssswwoorrdd..
To add a chime to a zone,
enter your Password and
press:
To cancel a chime zone
enter the factory pre-set
code or your password.
Then press PP55EE00EE.PP55EE11EEfor Zone 1.
PP55EE22EEfor Zone 2.
You have 5 seconds to
enter the relevant code.
To exit programming
press PP00EE.
3
TTOOCCAANNCCEELLAACCHHIIMMEEZZOONNEETTOOSSEETTAACCHHIIMMEEZZOONNEE
To exit programming
press PP00EE.
2
11
ukpanels.com

MMiiccrroommaarrkk
DDeevvoonnsshhiirreeHHoouussee,,555500WWhhiitteeHHaarrttLLaannee,,LLoonnddoonnNN117777RRQQ
Micromark continuously tries to improve its products for the benefit of its customers. For this reason we reserve the right to make changes to any product at any time, without notice.
MICROMARK INSTRUCTIONS MM25201/160805 © Micromark 2005
If you have any difficulty with this Alarm System, please check the following before telephoning the Helpline.
PPRROOBBLLEEMMSSOOLLUUTTIIOONN
When finishing programming and pressing PP00EEinternal
alarm sounds.
Unable to set system. Zone LED illuminated.
Panel showing fault.
• Tamper spring on panel not depressed.
• Bad connections at terminal block.
• Tighten wall screw and refit.
• Check terminal block connections.
• Door open or PIR is getting tripped by someone
moving.
• Close doors and keep still while entering password.
• Door contacts not close enough – 5mm. • Move contact magnet closer.
TROUBLESHOOTING
PPOOSSSSIIBBLLEECCAAUUSSEE
**PPLLEEAASSEENNOOTTEE::TToommaaiinnttaaiinnooppttiimmuummsseeccuurriittyy,,tthheebbaatttteerryysshhoouullddbbeecchheecckkeeddrreegguullaarrllyyaannddrreenneewweeddeevveerryyyyeeaarr..
TThhiissaapppplliiaannccee//ffiittttiinnggiissmmaarrkkeeddaaccccoorrddiinnggttootthheeEEuurrooppeeaannddiirreeccttiivvee22000022//9966//EECCoonnWWaasstteeEElleeccttrriiccaallaannddEElleeccttrroonniiccEEqquuiippmmeenntt
((WWEEEEEE))..BByyeennssuurriinnggtthhiisspprroodduuccttiissddiissppoosseeddooffccoorrrreeccttllyy,,yyoouuwwiillllhheellpppprreevveennttppootteennttiiaallnneeggaattiivveeccoonnsseeqquueenncceessffoorrtthhee
eennvviirroonnmmeennttaannddhhuummaannhheeaalltthh,,wwhhiicchhccoouullddootthheerrwwiisseebbeeccaauusseeddbbyyiinnaapppprroopprriiaatteewwaasstteehhaannddlliinnggoofftthhiisspprroodduucctt..
TThheessyymmbboolloonntthheepprroodduucctt,,oorroonntthheeddooccuummeennttssaaccccoommppaannyyiinnggtthheepprroodduucctt,,tthheeCCrroosssseeddOOuuttWWhheeeelliieeBBiinnssyymmbbooll,,
iinnddiiccaatteesstthhaatttthhiissaapppplliiaannccee//ffiittttiinnggmmaayynnoottbbeettrreeaatteeddaasshhoouusseehhoollddwwaassttee..IInnsstteeaaddiittsshhaallllbbeehhaannddeeddoovveerrttootthhee
aapppplliiccaabblleeccoolllleeccttiioonnppooiinnttffoorrtthheerreeccyycclliinnggooffeelleeccttrriiccaallaannddeelleeccttrroonniicceeqquuiippmmeenntt..DDiissppoossaallmmuussttbbeeccaarrrriieeddoouuttiinn
aaccccoorrddaanncceewwiitthhllooccaalleennvviirroonnmmeennttaallrreegguullaattiioonnssffoorrwwaasstteeddiissppoossaall..FFoorrmmoorreeddeettaaiilleeddiinnffoorrmmaattiioonnaabboouuttttrreeaattmmeenntt,,
rreeccoovveerryyaannddrreeccyycclliinnggoofftthhiisspprroodduucctt,,pplleeaasseeccoonnttaaccttyyoouurrllooccaallaauutthhoorriittyy,,yyoouurrhhoouusseehhoollddwwaasstteeddiissppoossaallsseerrvviicceeoorr
tthheerreettaaiilleerrwwhheerreeyyoouuppuurrcchhaasseeddtthheepprroodduucctt..
ukpanels.com