Mieo JH305 User manual

Digital Clinical Thermometer
User Manual
Model:JH305

Digital Clinical Thermometer
User Manual
Model:JH305
Thank you for purchasing our Digital Clinical
Thermometer.Thank you for purchasing our Digital
Clinical Thermometer. It is mainly used for oral and
Armpit temperature measurement and usually
operated by medical staffs, patient himself or his
families. Not used for life support or rescue. If the
device is invalid will not cause any accident, no
need special or emergency measures.
Please read these instructions carefully to
ensure accurate temperature measurements
and safe operation.
Please read
the following instructions to achieve the most
accurate temperature and safe operation.With
proper care and use,your thermometer will provide
you reliable reading for many years.
In order to enable you use the thermometer
safely and properly, and keep away from the harm
because of please note the warning
signs and symbols in the manual.
misusing,
Warning signs, symbols and their meaning are
explained as follows:
Safety Precautions
Casualties may occurred when misuse
Refer to instruction
Warning
Misuse may cause personal injury
or product damaged.
Note
Symbols
European Union's Waste Electrical and
Electric Equipment in accordance with
Article 11 (2) of Directive 2002/96/EC WEEE).
To protect the environment, product must be
disposed at the definite places according to
your national or local regulations
Indicates is BF-type
equipment.
No rain
Fragile UP
Fragile,
Handle with care
Manufacturer
Authorised Representative In
The European Community
EC R EP
Stand-by
Keep dry
This way up
Over View
1
1-----Sensor Probe 4-----ON/OFF button
5-----Battery cover
2-----Body
3-----LCD
2
3
4
5
1

Warning
It is very dangerous if the patients make
self-judgement and treatment by means of
measuring results. So please be sure to follow
the doctor's guidance.
Self-judgement may worsen the illness.
The thermometer is only for Oral and Armpit
temperature. So don't use for other parts
(such as in the ear) .
Otherwise, the thermometer will not measure the
body temperature, and it may hurt the body.
Keep the thermometer far from the place
which kid can touch.
It may injure the mouth if kid measures by himself.
If swallows the battery or protective film accidentally,
please contact doctor immediately.
Keep the thermometer in measure location for
30 minutes before operation, if there is big
difference in temperature between storage
site and measuring site.
Otherwise may get incorrect measurement results.
Do not measure body temperature within 30
minutes after meal, sports or bath.
Otherwise may get incorrect measurement results.
Please note the battery polarity when replace
the battery.
Otherwise it may cause leakage, heat, rupture
even damage the thermometer.
Otherwise it will cause bacterial infection.
Not allow for multiple users at same time.
Don't take down, repair and reform product
by yourself.
The operator not at the same time contact
battery and patients.
Note
Please don't force the probe into the mouth. And
if you feel pain or other unusual feeling, please
stop to use.
Otherwise will injury mouth.
Don't use product if suffering from mouth ulcers,
bleeding gums.
Otherwise it will deterioate the infected part.
To deal with the old batteries and product,please
compliance with the local law or prescribe.
Otherwise it will cause injury because of explosion.
Do not throw the batteries into fire.
Please indicate the results was measured by digital
thermometer when consult with physician.
Please do not collide, drop, step and shake product
by force.
The measure result can not be substituted for the
consultation from doctors.
Avoid keep product in place with direct sunshine,
high temperature,heavy humidity,dust,close to
the fire,easy shock and vibration areas.
Please do not use the thermometer when suffer
electromagnetic interference.
The front part of the thermometer favorable
angle,the operation that should pay attention
to scratch hand.
℉/ Conversion
The default display unit is Celsius. Under power
off status, press and hold the button for at least
2 seconds, thermometer converts to ℃ or ℉.
Release the button, thermometer will save the
setting and enter measuring mode automatically.
℃
2

Operating Guide
l Press ON/OFF button to turn on the
thermometer. The LCD will be in full display for
2 seconds and sound beep.
Release the button, it displays the last result
for about 2 seconds. Then display 37.0℃. After
that, ℃ or ℉ flashes, entering measuring mode.If
the temperature is lower than 32℃, it shows
“LO” ; if higher than 42.9℃, it shows“HI”.when
temperature becomes stable, the ℃ or ℉stops
flashing and buzzer sounds beep.When measuring
ends, thermometer will memory the largest result.
In order to get an more accurate result, measuring
another 3 minutes after hearing the alarm is
recommended. If the temperature is higher than
37.8℃,thermometer will sound beep for about 10
seconds.
l Turn the thermometer off by pressing the on/off
button to extend the battery life after recording
the measuring result. The thermometer will
automatically turn off in 8 minutes.
Oral Use
Hold thermometer by hand to avoid movement.
Don't open the mouth or breathe by mouth when
measuring.
Close mouth for at least 3 minutes before
measuring to balance the oral temperature
Put the thermometer under tongue and close
to the base of tongue(refer to picture)
In order to get a more accurate result,
measuring another 3 minutes after hearing the
alarm is recommended.
Under-the-arm Use
Wipe the under arm with a towel
Place the thermometer to the centre of armpit.
Push it up softly and clamp the sensor probe in
the armpit. Please hold the arm by another hand
in order to get full contact.
To get a more accurate result, it is better to
measure another 3 minutes after hearing the
alarm. Then take out the body thermometer to
read the value.
Replace Battery
When icon flashes indicates
low battery and need to replace
new one.
Remove the battery cover.
Put the new battery
If long time no use of this thermometer,please remove
the battery.
In order to protect the environment, please send
the waste batteries to the appropriate collection
points according to the national or local laws.
Note:
Please properly dispose of the batteries away from
small children and heat.
Wipe with paper towel, then sanitize with
alcohol after using each time.
3

How to maintain and store the thermometer
Maintain method
Use a soft, dry cloth to wipe down the dirt on unit softly.
Use a wet cloth or neutral detergent to wipe the serious
dirt, then wipe with dry cloth.
Don't wipe the LCD when wipe by alcohol.
Maintenance
Don't use propellant, thinner or gasoline to clean the unit.
Storage method
Avoid keep product in place with direct sunshine,
high temperature, heavy humidity, dust, close to
the fire, easy shock and vibration areas.
Keep the thermometer far from the place
where kid easy touch.
LCD display Meaning
Self-checking once turn on,
LCD full screen display
the unit is Measurement
The measured temperature
is too high, more than 42.9℃
The measured temperature is
too low, lower than 32.0℃
Operating temperature is too
high or too low, out of
temperature measuring range.
LCD display symbols indication
Name: Digital Clinical Thermometer
Model: JH305
Applied Part: Sensor Probe
Measuring range:32.0℃~42.9℃
Accuracy: ±0.1℃(37.0℃~39.0℃)
±0.2℃(35.3℃~36.9℃& 39.1℃~41.0℃)
±0.3℃(<35.3℃& >41.0℃ )
Function and intended usage:
Classification according to prevent electric shock:
type of internal power and B-type application part
Classification according to operation mode:
Continuous operation
Measure temperature of oral,armpit
Production classification:
Product Specification
Expected service life: 2 years
Celsius-Fahrenheit
Low battery indicator
4

Digital Clinical Thermometer
Item:JH305
Purchase date:
Shop name:
Shop address:
Name:
Family address:
Telephone:
Shop stamp:
After-sale service
Free repairing within one year since purchase date
if proper use.
In the request for warranty service, you must have a
seal of the purchase date and place of purchase
(including name and address). Be sure to purchase
this product requires the clerk stamped on this
Guarantee.
Out of the warranty, repair service will be charged.
Not reissue, please keep this warrantee safely.
Repair Card
Name:
MIEO Product Guarantee
1.
2.
3.
4.
Service: must return to manufacturers,
by professionally trained personnel to repair it.
Thermometer
Power supply: DC1.5V
Power consumption: 0.2 mW(No back light)
Battery life: 1year(about 300 times measuring
Weight: about 10g(with battery)
Dimension: L127mm xW18.5mm xH10mm
Operation environment: + 5℃ ~+ 4 0℃ ≤85%RH
700hpa~1060hpa
Transport/Storage
environment:
Accessories:
User's manual、
AG13 battery 1pcs(already pre-loaded in the unit)
Consumables: Battery
Any improvement on this product no need a
special notice
-25℃~+55℃ ≤95%RH
500hpa~1060hpa
5