manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADC
  6. •
  7. Thermometer
  8. •
  9. ADC Adtemp II 412 Maintenance manual

ADC Adtemp II 412 Maintenance manual

Other ADC Thermometer manuals

ADC Adtemp V 418 Maintenance manual

ADC

ADC Adtemp V 418 Maintenance manual

ADC Adtemp 418N User manual

ADC

ADC Adtemp 418N User manual

ADC Adtemp Mini 432 User manual

ADC

ADC Adtemp Mini 432 User manual

ADC Adtemp 422 Maintenance manual

ADC

ADC Adtemp 422 Maintenance manual

ADC Adtemp TempleTouch 427 User manual

ADC

ADC Adtemp TempleTouch 427 User manual

ADC Adtemp 427 Temple Touch Maintenance manual

ADC

ADC Adtemp 427 Temple Touch Maintenance manual

ADC Adtemp II 413B-00 Maintenance manual

ADC

ADC Adtemp II 413B-00 Maintenance manual

ADC Adtemp V 418 Owner's manual

ADC

ADC Adtemp V 418 Owner's manual

ADC Adtemp Temple Touch  427 User manual

ADC

ADC Adtemp Temple Touch 427 User manual

ADC Adtemp 429 User manual

ADC

ADC Adtemp 429 User manual

ADC Adtemp 422 Maintenance manual

ADC

ADC Adtemp 422 Maintenance manual

ADC Adtemp II 412 Maintenance manual

ADC

ADC Adtemp II 412 Maintenance manual

ADC Adtemp 424 Maintenance manual

ADC

ADC Adtemp 424 Maintenance manual

ADC Adtemp II 413 Maintenance manual

ADC

ADC Adtemp II 413 Maintenance manual

ADC Adtemp V 418N User manual

ADC

ADC Adtemp V 418N User manual

ADC Adtemp 413 User manual

ADC

ADC Adtemp 413 User manual

ADC Adtemp ULTRA 417 User manual

ADC

ADC Adtemp ULTRA 417 User manual

ADC Adimals 426 User manual

ADC

ADC Adimals 426 User manual

ADC Adtemp 433 User manual

ADC

ADC Adtemp 433 User manual

ADC ADTEMP 421 User manual

ADC

ADC ADTEMP 421 User manual

ADC Adimals 426 User manual

ADC

ADC Adimals 426 User manual

ADC Adtemp 424 User manual

ADC

ADC Adtemp 424 User manual

ADC Adtemp ULTRA 417 Maintenance manual

ADC

ADC Adtemp ULTRA 417 Maintenance manual

ADC Adtemp 415FL User manual

ADC

ADC Adtemp 415FL User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

AdtempTM II 412
Digital Fever Thermometer
USE, CARE &
MAINTENANCE
Intended Use:
A digital thermometer is a device used to measure the body temperature o a patient by means
o a transducer coupled with an electric signal ampli ication, conditioning, and display unit.
Safety Infor ation:
• High, prolonged ever requires medical attention especially or young children.
Please contact your physician.
• Do not allow children to take their temperatures unattended.
• Read the enclosed instructions care ully to ensure accurate temperature readings.
Temperature readings are a ected by many actors including exercise, drinking hot or
cold beverages prior to taking a reading as well as technique.
• Do not allow children to walk or run during temperature taking. The rigid probe could
present a hazard. Oral, underarm, and rectal temperatures vary by approximately 1°F
(0.5°C).
• WARNING: Keep battery out o children’s reach. Swallowing battery could be harm ul.
Battery should not be recharged or placed into extreme heat as it may explode.
• CAUTION:
Do not take an axillary temperature through patient’s clothing. Direct probe
cover to skin contact is required.
• CAUTION:
Biting the probe tip while taking a temperature may result in damage to the
probe.
• CAUTION:
Do not autoclave. Please note the cleaning procedures described in this
manual
How to take te perature:
1.Place a probe cover care ully over the tip (Figure 1). Select
oral, underarm, or rectal as your measurement site based on the
individual requiring a temperature measurement.
2.Push the Multi-Function button located at the end o the thermometer. The display will
read: “188.8 ° ”. This is a unction check indicating the unit is working properly. The
last measured temperature will be displayed or approximately 2-seconds. Next the
thermometer will read L°F.(or L°C).
3.The °F or °C symbol will lash when the unit is ready to measure temperature. Please note
that the “ ” indicates a low battery. Do not expect an accurate temperature reading i this low
battery indicator is present. An “ERR” message in the window indicates your unit is not unc-
tioning properly.
4.Depending on the measurement site, the unit will complete measurement in 40 (rectal), 60
(oral), or approximately 90 (axillary) seconds. When the F° or C° symbol stops lashing and
the display reads a consistant temperature, the peak temperature has been reached.
5.Read and record the temperature and time or re erence. The reading will automatically
be stored in the memory.
6.Push the Multi-Function button to turn the unit o . This will prolong the battery li e. I
Figure 1
F
M
you do not turn the unit o , it will shut o automatically in approximately 10 minutes.
Oral use: ( or children 4 years and older)
1.Do not drink hot or cold luids, exercise or per orm other activities that will raise or lower
temperature readings when compared to your normal, average temperature.
The mouth should remain closed up to 5 minutes be ore attempting a read-
ing.
2.Place the probe tip well under the tongue as indicated (Figure 2).
3.Instruct children not to bite down on the probe.
4.The peak temperature should be reached in approximately 60 seconds. Opening the mouth
or improper placement o the probe tip could result in a longer time or a reading.
Rectal use:
1.Commonly used or babies, young children or when it is di icult to take an oral or under-
arm temperature.
2.A ter placing the probe cover on the thermometer, lubricate with a water-soluble jelly or pe-
troleum jelly.
3.Gently insert the probe tip no more than 1/2 inch or 1.3 cm into the rectum. Do not orce the
tip into the rectum i resistance is encountered.
4.Dispose o the used probe cover and wash the thermometer as recommended.
5.The peak temperature should be reached in approximately 40 seconds.
Underar (Axillary) use:
1.Wipe underarm with a dry towel.
2.Place probe tip in armpit and bring arm down against the body.
3.The probe should be pointing upward in the same direction as your body i possible.
4.The time required or an accurate underarm temperature may be 90 seconds or longer
depending on placement o the probe and closure o the arm against the body.
Operation of the °F - °C feature (How to change the measuring scale) From the “OFF” po-
sition, hold down the Multi-Function button or 5-sec. The thermometer will automatically
change rom °F - °C or °C - °F. Release the button. You may toggle between °C +°F. A ter 3-
sec. in one scale the °C or °F will lash, indicating ready to measure.
Standards:
Complies with EN 12470-3:2000 and ASTEM E 1112-00
The manufacturer recommends a calibration check every 2-years.
How to care for this product:
• Use o probe covers is recommended to help avoid spreading germs,
and to keep the thermometer clean. The thermometer should be cleaned
a ter use even when probe covers are used.
• Clean the thermometer tip and probe only using isopropyl alcohol or
soap and water.
• Store the unit in the protective case while not in use.
• Do not store or keep in direct sunlight, or in high temperatures.
• Keep battery away rom children.
• Do not open the thermometer.
Figure 2
• Do not drop the thermometer, as this may ruin the unit.
• The manu acturer recommends veri ying the accuracy by an authorized laboratory
Specifications
Size: 5”L x 3/ ”W x 3/8”H (12.7cm L x 1.905cm W x .9525cm H)
Weight: 0. 9 oz (1 grams)
Display: LCD, Liquid Crystal Display
Battery: 1.55v (LR 1) Alkaline
Battery Life: Estimated 1,500 uses
Measurement Time: Oral 60 Seconds / Rectal 0 Seconds / Axillary 90 Seconds
Measurement Range: 90.0°F to 109.9°F / 32.0°C to 3.9°C
Accuracy: 0.2°F / 0.1°C between 96.0°F to 107.0°F / 3 .0°C to 2.0°C at
a room temperature of 6 . °F to 82. °F / 18°C to 28°C
Measurement Mode: Real measurement with peak-hold method
Auto Turn Off: In approximately 10 minutes
Memory Feature: Stores last temperature taken.
WARRANTY: This Thermometer is guaranteed or a period o 24 months rom date o purchase. This
warranty does not cover batteries, or damage resulting rom improper handling or use. Speci ic legal
rights stipulated in your state may guide this warranty. I you have a legitimate claim under this warranty,
send item(s) postage paid to Service Center, Attn: Repair Dept., 55 Commerce Dr., Hauppauge, NY
11788. Please include your name and address, phone no., proo o purchase, and a brie note explaining
the problem., your return address and $2.00 to cover shipping and handling.
Probe Tip Display Window Multi-Function Button
Parts and Asse bly
ADC
55 Commerce Drive
Hauppauge, NY 11788
U.S.A.
ADC (UK) Ltd.
Unit 6, PO1 1TH
United Kingdom
Inspected in the U.S.A.
Made in China
tel: 631-273-9600, 1-800-232-2670
fax: 631-273-9659
www.adctoday.com
email: info@adctoday.com
IB p/n 93- 12-00 rev 2 english