INSTRUCTIONS • ENGLISH
PLEASE READ AND SAVE THESE INSTRUCTIONS
• This product is not intended to diagnose or treat any health problem or disease and
should not be used as a substitute for the consultation and advice of a physician or
other medical professional.
• Thermometers should only be used under the supervision of an adult.
• Before use, it is recommended that the patient avoid eating, drinking, smoking or
exercising for at least twenty minutes prior to taking a measurement. Never walk, run
or talk during a measurement.
NORMAL BODY TEMPERATURE / FEVER INDICATOR
Body temperature can vary from 97°F and 100.0°F and still be considered normal. The
medically accepted‘normal’body temperature is 98.6°F Body temperature is commonly
lower in the upon waking than at any point during the rest of an individual’s waking
hours.
Temperature readings will vary based on the body location point of the reading. Average
‘normal’temperature ranges by measurement location site:
Forehead 97.0°F–100.0°F (36.1°C–37.8°C)
Oral 97.0°F–100.0°F (36.1°C–37.8°C)
Rectal 97.3°F–100.4°F (36.3°C–38.0°C)
Axillary 95.4°F–99.0°F (35.2°C–37.2°C)
A fever is dened as a body temperature that is elevated above the normal for that per-
son. It is important to determine what is normal for an individual before determining if
a fever is present. Tracking an individual’s temperature on a consistent basis, at the same
body site and at the same time everyday when the person is well or healthy will help
determine an individual’s normal temperature.
GUIDELINES FOR TEMPLE MEASUREMENTS
This thermometer is designed to measure the temperature at the forehead,
in proximity to the temple area between the end of the eyebrow and the
hairline.
• Do not place the thermometer on scar tissue, skin disorder, open sores
or abrasions or patients in trauma.
• Consult your physician when using drug therapies that may elevate
skin temperature in the forehead.
• Do not use skin exposed to direct sunlight, replace heat, air conditioner
or fan air ow, or hot/cold compress therapies.
• Wait at least one minute between measurements to allow the unit
sensor to readjust to room temperature.
• If the thermometer has been stored in an excessively cold or warm
environment, allow the thermometer to adjust to the ambient room
temperature before use. Performance and operation of this unit may be compromised if
operated outside of the specied temperature and humidity operating ranges.
OPERATING INSTRUCTIONS
1. Press and release the POWER button to activate the thermometer.
2. The unit will beep and the thermometer will perform a self-test, showing
all of the symbols on the display, Fig 1.
3. The last measurement taken will show on the display.
4. Gently place the probe in the center of the temple area between the
end of the eyebrow and the hairline. Maintain rm contact with the
skin, hold the thermometer in place during the reading and do not
move the thermometer to ensure reliable results.
5. Do NOT press the power button again. The measurement will start
automatically once the probe is in place and will take approximately
6-8 seconds. A running circle will appear on the display indicating the
reading is in progress, Fig 2.
6. The unit will sound one long beep when the measurement is complete
and the reading will appear on the display, Fig 3.
7. To turn the unit o, simply press the POWER button. The unit will
automatically shut-o after approximately one minute.
NOTE: If you take another measurement before 1 minute has elapsed, the device will
perform a 10 to 0 countdown to allow the device to reset for a new measurement.
DO NOT TRY TO MEASURE DURING THIS COUNTDOWN. If you attempt to measure during the
countdown time, the device will display the previous result, beep 8 times and turn itself o
automatically.
SETTING THE OPERATING SCALE °F OR °C
The device setting is by default Fahrenheit (°F). To change the scale to °C,
or back to °F:
1. While o, press and hold the Power button for 5 seconds, on the screen
you will see the icon (°F , °C ) changes.
2. Release the button, the hourglass icon will disappear in 5 seconds
indicating that the device is ready for use.
MEMORY RECALL
This unit includes a recall of the last measurement taken. When the unit is OFF, press the
POWER button to turn the unit on, and release. After the self-test, the
unit will briey show the last reading on the display.
REPLACING THE BATTERY
This thermometer includes 2 AAA 1.5V batteries. The low-battery
symbol will appear on the top center of the display when the battery
needs to be changed.
1. Carefully slide the battery cap away from the unit.
2. Replace the batteries, taking care to match the correct polarity.
3. Carefully replace the battery cap.
4. Do not dispose of used batteries in the trash. Consult your local recycling
center for the proper way to dispose of batteries in your area. Keep used
batteries away from children, pets and excessive heat.
Temple Touch
Mini Thermometer
Model 09-331
THANK YOU FOR PURCHASING THE MINI TEMPLE THERMOMETER. PLEASE
READ THESE INSTRUCTIONS CAREFULLY TO ENSURE PROPER USE AND SAFE
OPERATION OF YOUR THERMOMETER.
TROUBLESHOOTING / IDENTIFYING DISPLAY SYMBOLS
Performance may be degraded should one or more of the following occur:
• Operation outside stated temperature and humidity range
• Storage outside state temperature and humidity range
• Mechanical shock
• Patient temperature is below ambient temperature
The thermometer has been designed to display feedback-warnings to ensure proper usage
and accurate temperature measurement. When an error appears, the device will“beep”5
times, and then the thermometer will turn o automatically. In the event of a malfunction or
incorrect temperature measurement, the following warnings will be displayed:
PRODUCT SPECIFICATIONS
MEASUREMENT TIME: 6–8 seconds
MEASUREMENT SITE: Temple area of forehead
MEASUREMENT RANGE: 95.0°F – 107.6°F (35° – 42°C)
OPERATING TEMPERATURE: 60.8°F – 104.0°F (16°C – 40°C);
Humidity 15-95% (non condensing)
STORAGE TEMPERATURE: -4.0°F – 122.0°F (-20°C – 50°C);
Humidity 15-95% (non condensing)
MEASUREMENT SCALE: Fahrenheit and Celsius
MEMORY: Recall of last measurement taken
BATTERY: 2 AAA 1.5V batteries
BATTERY LIFE: Approximately 24 months; minimum of 1000 measurements
AUTOMATIC SHUT-OFF: Approximately after 1 minute of non-use
ACCURACY: complies with ASTM E 1112-00 standards
DISPLAY: Liquid crystal display
DISPLAY RESOLUTION: LCD 0.63”x 0.44”
DIMENSIONS: 4.7”X 1.17”X 1”
WEIGHT: 1.3 ounces with batteries
Specications are subject to change without notice.
Toll-Free Customer Care Help Line: 1-866-326-1313
Monday – Friday 8:30 a.m. – 4:30 p.m. CST
www.veridianhealthcare.com
Fig. 1
Fig. 2
Fig. 3
Correct Placement
Incorrect Placement
Digital
Display
POWER
Button
Probe
Sensor
Battery
Compartment The Temple Touch Thermometer
works by measuring the heat ow
from the blood vessels to the skin.
That measurement is then
converted to a comparable body
temperature.
Quick Start Tips
1. Press and release the POWER button, wait 2-seconds.
2. Hold unit rmly to temple until a long single beep is heard, 6-8 seconds
3. Results will be displayed on the screen.
4. Wait one minute before new measurement.
5. To alternate between °F and °C, press and hold the POWER button.
Blood Vessels
Heat/Energy Flow
Skin
FCC STATEMENT
IMPORTANT INFORMATION REQUIRED BY THE FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference; and (2) this device must accept any interference received, including
interference that may cause undesirable operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not
installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment o
and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CAUTION: Changes or modications not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
ONE-YEAR WARRANTY
Congratulations on your purchase of a Temple Touch Mini Thermometer. Your Temple Touch Mini Thermometer is
covered by the following limited warranty commencing upon the date of purchase, and subject to the following
terms and conditions:
The Warrantor warrants that its Temple Touch Mini Thermometer will be free from defects in materials and
workmanship under normal consumer usage for a period of one year for the original purchaser of the Mini Temple
Thermometer.
Periodic maintenance, repair and replacement of parts due to normal wear and tear are excluded from coverage.
Defects or damage that result from: (a) improper operation, storage, misuse or abuse, accident or neglect, such
as physical damage (cracks, scratches, etc.) to the surface of the product resulting from misuse; (b) contact with
liquid, water, rain, extreme humidity or heavy perspiration, sand, dirt or the like, extreme heat, or food; (c) use of
the Temple Touch Mini Thermometer for commercial purposes or subjecting the Temple Touch Mini Thermometer
to abnormal usage or conditions; or (d) other acts which are not the fault of the Warrantor, are excluded from
coverage. This warranty does not cover batteries or other power sources that may be provided with, or used with
the Temple Touch Mini Thermometer.
If the Digital Thermometer fails to conform to this limited warranty, return the Temple Touch Mini Thermometer
to: Attn: Repair Department, 1175 Lakeside Drive, Gurnee, IL, 60031. When returning a product, please also
include: (i) a copy of your receipt, bill of sale or other comparable proof of purchase; (ii) a written description of the
problem; and (iii) your name, address and telephone number. Carefully package the product to avoid any damage
that may occur while in transit; shipping insurance with returned receipt is recommended. At our option, the war-
rantor will repair or replace the unit found to be defective in materials or workmanship under normal consumer
usage. The purchaser will be notied of any additional repairs required prior to completing the repair, and will be
responsible for parts charges, if any, and repair charges not covered by this limited warranty.
EXCEPT AS PROVIDED FOR IN THIS LIMITED WARRANTY, ALL EXPRESS AND IMPLIED WARRANTIES AND CONDITIONS
ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FIT-
NESS FOR A PARTICULAR PURPOSE. THE REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS LIMITED WARRANTY
IS THE EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED. IN NO EVENT SHALL THE WARRANTOR BE LIABLE, WHETHER IN CONTRACT OR TORT (INCLUDING NEGLI-
GENCE) FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL,
SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND, OR FOR DAMAGES TO, OR LOSS OF, OTHER PROPERTY OR
EQUIPMENT OR PERSONAL INJURIES TO THE FULL EXTENT THESE DAMAGES MAY BE DISCLAIMED BY LAW.
Some states and jurisdictions do not allow the limitation or exclusion of incidental or consequential damages, or
limitation on the length of an implied warranty, so the above limitations or exclusions may not apply to you. This
warranty gives you specic legal rights, and you may also have other rights that vary from state to state or from
one jurisdiction to another.
CARE AND CLEANING INSTRUCTIONS
• Wipe the probe with an alcohol swab or a cotton swab moistened with 70%
isopropyl alcohol before & after each use
• After cleaning, wait at least 2 minutes before taking a measurement for the unit
to readjust to room temperature
• Use only a soft dry cloth to clean the body of the thermometer (if necessary).
Never use an abrasive cleanser or submerge the thermometer in water or other
liquids
• Do not expose the thermometer to extreme temperatures, humidity, direct
sunlight or shock
• Store at room temperature
Distributed by:
Veridian Healthcare
1175 Lakeside Drive
Gurnee, IL 60031
www.veridianhealthcare.com
Product of Israel
Packed in China
#93-1142 08/19
©2019 Veridian Healthcare, LLC
Protected by US patent
# 7,597,668 B2
Error Problem/Cause Solution
The measured temperature is
above 107.6°F (42°C)
These are not device malfunctions
The measured temperature is
below 95°F (35°C)
These are not device malfunctions
The thermometer is too cold or too
hot to operate
Temperature did not register
because of poor contact, patient
movement or poor placement
Unit malfunctioned
Low battery - Battery icon
ashes
Drained battery - Battery icon is
the only icon on the display and
unit turns o
1. Turn the unit OFF and then ON again
2. Retake temperature
3. If still reads HI, this indicates that
the patient has a high fever; seek
medical attention
1. Turn the unit OFF and then ON again
2. Retake temperature
3. If still reads LO, this indicates that
the patient has a low body tempera-
ture; seek medical attention
1. Verify that the room temperature
within product range 60.8°F-104°F
(16° C - 40° C)
2. Retake temperature
Turn the unit OFF, wait 2 minutes, turn
it ON again and retake temperature
Do not use the thermometer – contact
Customer Care
Battery is low; enough power remains
for approximately 10 measurements
Battery is completely expired and
must be replaced