Milwaukee pH51 User manual

pH51
Waterproof pH-meter
USER MANUAL
SPECIFICATIONS
Range
0.0 to 14.0 pH
Resolution
0.1pH
Accuracy(@20°C)
±0.1pH
Typical EMC Deviation
±0.1pH
Calibration
Manual, at 2 points
throughtrimmers
pHelectrode
MA73600or
(replaceable)
MA73600-S
Environment
0to50°C; 100% RH
Batterytype
3 x 1.5V, alkaline
Batterylife
morethan1500
hoursof continuous use
Dimensions
165 x 30 x 30 mm
Weight
80g
ACCESSORIES
MA73600 ReplaceablepHelectrode
MA73600-S ReplaceablepHlong
electrode
M10007B pH7.01 buffer solution,
20 mL sachet (25 pcs)
M10004B pH4.01 buffer solution,
20 mL sachet (25 pcs)
M10010B pH10.01buffer solution,
20 mL sachet (25 pcs)
M10000B Electroderinsesolution,
20 mL sachet (25 pcs)
MA9015 Electrodestoragesolution,
220mL bottle
MA9016 Electrode cleaning solution,
220mL bottle
This meter is in compliance with the CE directives.
ISTRPH51R2 05/03
CONDITIONING:
Remove the cap and immerse the
pH51
in
MA9015 storage solution for 2 hours to acti-
vate the electrode.
CALIBRATION:
Unscrew the battery compartment cap on the
top of the meter and perform one of the follow-
ing two-point calibration procedure, according
to the required application:
Acid calibration for measurements below pH7:
• Immerse the electrode in pH7.01
(M10007) buffer solution.
• Allow the reading to stabilize and
with a small screwdriver turn the
“7” calibration trimmer inside the
battery compartment until the dis-
play shows "7.0".
• Rinse the electrode with tap water
and immerse it in pH4.01 (M10004)
buffer solution.
• Allow the reading to stabilize and with a
small screwdriver turn the “4” calibration trim-
mer until the display shows "4.0".
Alkaline calibration for measurements above pH7:
• Immerse the electrode in pH7.01 (M10007)
buffer solution.
• Allow the reading to stabilize and with a
small screwdriver turn the “7” calibration trim-
mer until the display shows "7.0".
• Rinse the electrode with tap water and im-
merse it in pH10.01 (M10010) buffer solution.
• Allow the reading to stabilize and with a
small screwdriver turn the “4” calibration trim-
mer until the display shows "10.0".
Replace the battery compartment cap.
OPERATION:
• Remove the protective cap.
• Turn the
pH51
on by pressing the ON key.
• Immerse the electrode in the solution to be
tested.
• Stir gently and wait for the reading to
stabilize.
• After use, rinse the electrode with wa-
ter to minimize contamination.
• Store the electrode with a few drops of
storage (MA9015) or pH7 (M10007)
solution in the protective cap.
• Always replace the protective cap after use.
NEVER USE DISTILLED OR DEIONIZED WA-
TER FOR STORAGE PURPOSES.
ELECTRODE REPLACEMENT:
The electrode can be easily replaced in the
following way:
• Remove the protective cap.
• Unscrew the plastic ring on the top
of the electrode.
• Pull out the MA73600 (or
MA73600-S) pH electrode and re-
place it with a new one (aligning
the colored pin towards the LCD
side).
• Make sure the gaskets are in place
before screwing back the ring.
BATTERY REPLACEMENT:
pH51
is supplied with BEPS (Battery Error Pre-
venting System) which avoids any erroneous
reading due to low battery level, by switching the
meter off. To replace the batteries unscrew the
battery compartment cap and replace all three
1.5V batteries while paying attention to their po-
larity. Make sure the gasket is in place before
screwing back the cap.
Batteries should only be replaced in a nonhaz-
ardous area using the battery type specified in
this instruction manual.
WARRANTY:
This meter is warranted from all defects in materials and manufacturing
for a period of two years. The electrode is warranted for a period of
one year. During this period, the required repair or replacement of parts,
where the damage is not due to negligence or erroneous operation by the
user, will be effected free of charge.

Other Milwaukee Measuring Instrument manuals

Milwaukee 2217-40 User manual

Milwaukee

Milwaukee 2217-40 User manual

Milwaukee MI407 User manual

Milwaukee

Milwaukee MI407 User manual

Milwaukee MW11 User manual

Milwaukee

Milwaukee MW11 User manual

Milwaukee 2237-20 User manual

Milwaukee

Milwaukee 2237-20 User manual

Milwaukee MI 413 User manual

Milwaukee

Milwaukee MI 413 User manual

Milwaukee Heavy Duty 2270-20 User manual

Milwaukee

Milwaukee Heavy Duty 2270-20 User manual

Milwaukee MR100ATC User manual

Milwaukee

Milwaukee MR100ATC User manual

Milwaukee M12 3622-20 User manual

Milwaukee

Milwaukee M12 3622-20 User manual

Milwaukee Mi170 User manual

Milwaukee

Milwaukee Mi170 User manual

Milwaukee 3712 User manual

Milwaukee

Milwaukee 3712 User manual

Milwaukee 2235-40 User manual

Milwaukee

Milwaukee 2235-40 User manual

Milwaukee MW101 User manual

Milwaukee

Milwaukee MW101 User manual

Milwaukee MW12 User manual

Milwaukee

Milwaukee MW12 User manual

Milwaukee MI455 User manual

Milwaukee

Milwaukee MI455 User manual

Milwaukee MAX MW160 User manual

Milwaukee

Milwaukee MAX MW160 User manual

Milwaukee Smart PH Meter User manual

Milwaukee

Milwaukee Smart PH Meter User manual

Milwaukee MC310 User manual

Milwaukee

Milwaukee MC310 User manual

Milwaukee MI605 User manual

Milwaukee

Milwaukee MI605 User manual

Milwaukee MW802 User manual

Milwaukee

Milwaukee MW802 User manual

Milwaukee MW100 User manual

Milwaukee

Milwaukee MW100 User manual

Milwaukee MI 405 User manual

Milwaukee

Milwaukee MI 405 User manual

Milwaukee MW101 User manual

Milwaukee

Milwaukee MW101 User manual

Milwaukee MW105 MAX User manual

Milwaukee

Milwaukee MW105 MAX User manual

Milwaukee MW11 User manual

Milwaukee

Milwaukee MW11 User manual

Popular Measuring Instrument manuals by other brands

SDI db checker instructions

SDI

SDI db checker instructions

CommScope OneCell Hardware installation guide

CommScope

CommScope OneCell Hardware installation guide

ND MultiCube Single Phase Installation and operation

ND

ND MultiCube Single Phase Installation and operation

fos4X Blackbird OECD MDE1117 Instructions for use

fos4X

fos4X Blackbird OECD MDE1117 Instructions for use

Omron K3TJ manual

Omron

Omron K3TJ manual

Sierra RedyCompact Series instruction manual

Sierra

Sierra RedyCompact Series instruction manual

WIKA mensor 9476 operating instructions

WIKA

WIKA mensor 9476 operating instructions

Bullard COHP User instructions

Bullard

Bullard COHP User instructions

Servomex SERVOTOUGH SpectraExact 2500 Series installation manual

Servomex

Servomex SERVOTOUGH SpectraExact 2500 Series installation manual

SEFRAM M9885A00 operating manual

SEFRAM

SEFRAM M9885A00 operating manual

Pitney Bowes DM300c series instructions

Pitney Bowes

Pitney Bowes DM300c series instructions

Fisher Scientific accumet AB200 instruction manual

Fisher Scientific

Fisher Scientific accumet AB200 instruction manual

ETI DEC-2 manual

ETI

ETI DEC-2 manual

Simex SRT-94 user manual

Simex

Simex SRT-94 user manual

LINSHANG LS133 user manual

LINSHANG

LINSHANG LS133 user manual

Shodex OHpak SB-2000 Series Operation manual

Shodex

Shodex OHpak SB-2000 Series Operation manual

Honeywell E-Mon KWH owner's manual

Honeywell

Honeywell E-Mon KWH owner's manual

Emerson FB2100 quick start guide

Emerson

Emerson FB2100 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.