
4
ENGLISH
¡:DOOWKLFNQHVVPP ¡:DOOWKLFNQHVVPP
¡:DOOWKLFNQHVVPP ¡:DOOWKLFNQHVVPP
It is strictly prohibited to use pipes with thin wall not listed in
WKHDERYHWDEOH
,IWKHLQVLGHRISLSHLVFRQWDPLQDWHGLWFRXOGFDXVHGHWHULRUDWLRQ
RIUHIULJHUDWRURLORURWKHUSUREOHPV
- Store the piping to be used during installation indoors and
NHHSERWKHQGVRIWKHSLSLQJVHDOHGXQWLOMXVWEHIRUHEUD]LQJ
(Store elbows and other joints in a plastic bag.)
,IGXVWGLUWRUZDWHUHQWHUVWKHUHIULJHUDQWF\FOHGHWHULRUDWLRQ
of the oil and compressor trouble may result.
8VHHVWHURLOHWKHURLORUDON\OEHQ]HQHVPDOODPRXQWVDPH
DVWKHUHIULJHUDWRURLOWRFRDWÀDUHVDQGÀDQJHFRQQHFWLRQV
- The refrigerator oil will degrade if it is mixed with a large
amount of mineral oil.
- Do not use a refrigerant other than R410A.
,IDQRWKHUUHIULJHUDQW5HWFLVXVHGWKHFKORULQHLQWKHUHIULJ-
erant may cause the refrigerator oil to deteriorate.
8VHDYDFXXPSXPSZLWKDUHYHUVHÀRZFKHFNYDOYH
7KHYDFXXPSXPSRLOPD\ÀRZEDFNLQWRWKHUHIULJHUDQWF\FOH
and cause the refrigerator oil to deteriorate.
- For the following tools, use only the tools special to the
refrigerant R410A.
7RROVDVOLVWHGLQWKHIROORZLQJWDEOHDUHUHTXLUHGIRUWKHUHIULJ-
erant R410A.
Tool name (For R410A)
Gauge manifold Flare tool
Charging hose 3URWUXVLRQDGMXVWFRSSHUSLSHJDXJH
Gas leak detector Vacuum pump adaptor
7RUTXHZUHQFK Balance for refrigerant charging
- Be especially careful when managing the tools.
,IGXVWGLUWRUZDWHUJHWVLQWKHUHIULJHUDQWF\FOHWKHUHIULJHUDQW
may deteriorate.
- Do not use a charging cylinder.
-
Using a charging cylinder may cause the refrigerant to deterio-
rate.
5HIULJHUDQWOHDNDJHPD\FDXVHVXIIRFDWLRQ3URYLGHYHQWLOD-
WLRQLQDFFRUGDQFHZLWK(1
1.4. Before conducting supply pipe
and drain pipe work
[Supply pipe work is not required for GUF-50, 100RD4]
Caution:
7KHZDWHUTXDOLW\RIWKHSHUPHDEOH¿OPKXPLGL¿HUVVXSSO\
ZDWHUVKRXOGPHHWSXEOLFZDWHUZRUNVVWDQGDUGVDQGKDYHD
hardness less than 100 mg/ . If the supply water does not
PHHWWKHVHVWDQGDUGVXVHDGHLRQL]HU
- The supply pressure must be within the range of 2u104pa to
49u104pa.
-
6XSSO\SUHVVXUHWKDWLVORZHUWKDQWKHVSHFL¿HGUDQJHZLOOFDXVH
WKHZDWHUWRQRWVXSSOLHGWKHSHUPHDEOH¿OPKXPLGLWLHUDQGWKHKX-
PLGL¿HUPD\QRWZRUN6XSSO\SUHVVXUHWKDWH[FHHGVWKHVSHFL¿HG
range may cause damage to the solenoid valve and result in water
leaks.
- Drain pipe gradient must be more than 1/100.
- Drain water will not be properly discharged.
)RUDUHDVWKDWDUHH[WUHPHO\FROGLQZLQWHUSHUIRUPIUHH]H
SUHYHQWLRQRQWKHVXSSO\SLSHE\ZUDSSLQJDIUHH]HSUHYHQ-
tion heater and thermal insulation.
&ROGWHPSHUDWXUHVPD\IUHH]HZDWHUDQGGDPDJHVXSSO\SLSH
- Install the drain piping according to this installation Manual
to ensure proper drainage. Wrap thermal insulation around
WKHSLSHVWRSUHYHQWFRQGHQVDWLRQ
- Improper drain piping may cause water leakage and damage to
furniture and other possessions.
1.5. Before getting installed
Caution:
- Do not install the unit where combustible gas may leak.
,IWKHJDVOHDNVDQGDFFXPXODWHVDURXQGWKHXQLWDQH[SORVLRQ
may result.
- Do not use the Fresh Master where food, pets, plants, preci-
sion instruments, or artwork are kept.
7KHTXDOLW\RIWKHIRRGHWFPD\GHWHULRUDWH
'RQRWXVHWKH)UHVK0DVWHULQVSHFLDOHQYLURQPHQWV
2LOVWHDPVXOIXULFVPRNHHWFFDQVLJQL¿FDQWO\UHGXFHWKH
performance of the Fresh Master or damage its parts.
- When installing the unit in a hospital, communication station,
RUVLPLODUSODFHSURYLGHVXI¿FLHQWSURWHFWLRQDJDLQVWQRLVH
-
7KHLQYHUWHUHTXLSPHQWSULYDWHSRZHUJHQHUDWRUKLJKIUHTXHQF\
PHGLFDOHTXLSPHQWRUUDGLRFRPPXQLFDWLRQHTXLSPHQWPD\
FDXVHWKH)UHVK0DVWHUWRRSHUDWHHUURQHRXVO\RUIDLOWRRSHU-
DWH2QWKHRWKHUKDQGWKH)UHVK0DVWHUPD\DIIHFWVXFKHTXLS-
ment by creating noise that disturbs medical treatment or image
broadcasting.
- Do not install the unit on a structure that may cause leakage.
:KHQWKHURRPKXPLGLW\H[FHHGVRUZKHQWKHGUDLQSLSH
LVFORJJHGFRQGHQVDWLRQPD\GULSIURPWKH)UHVK0DVWHU
3HUIRUPFROOHFWLYHGUDLQDJHZRUNWRJHWKHUZLWKWKHRXWGRRUXQLW
DVUHTXLUHG
%HIRUHJHWWLQJLQVWDOOHGPRYHG
electrical work
Caution:
- Ground the unit.
'RQRWFRQQHFWWKHJURXQGZLUHWRJDVRUZDWHUSLSHVOLJKWQLQJ
URGVRUWHOHSKRQHJURXQGOLQHV,PSURSHUJURXQGLQJPD\UHVXOW
in electric shock.
-
Install the power cable so that tension is not applied to the cable.
- Tension may cause the cable to break and generate heat and
FDXVHD¿UH
- Install an leak circuit isolator, as required.
,IDQOHDNFLUFXLWLVRODWRULVQRWLQVWDOOHGHOHFWULFVKRFNPD\
result.
8VHSRZHUOLQHFDEOHVRIVXI¿FLHQWFXUUHQWFDUU\LQJFDSDFLW\
and rating.
-
&DEOHVWKDWDUHWRRVPDOOPD\OHDNJHQHUDWHKHDWDQGFDXVHD
¿UH
8VHRQO\DFLUFXLWLVRODWRUDQGIXVHRIWKHVSHFL¿HGFDSDFLW\
- A fuse or circuit isolator of a larger capacity or a steel or copper
ZLUHPD\UHVXOWLQDJHQHUDOXQLWIDLOXUHRU¿UH
- Do not wash the Fresh Master.
- Washing them may cause an electric shock.
-
Be careful that the installation base is not damaged by long
use.
,IWKHGDPDJHLVOHIWXQFRUUHFWHGWKHXQLWPD\IDOODQGFDXVH
SHUVRQDOLQMXU\RUSURSHUW\GDPDJH
%HYHU\FDUHIXODERXWSURGXFWWUDQVSRUWDWLRQ
- Only one person should not carry the product if it weighs more
than 20 kg.
- Fresh Master use PP bands for packaging. Do not use any PP
bands for a means of transportation. It is dangerous.
'RQRWWRXFKWKHKHDWH[FKDQJHU¿QV'RLQJVRPD\FXW\RXU
¿QJHUV
:KHQWUDQVSRUWLQJWKHRXWGRRUXQLWVXVSHQGLWDWWKHVSHFL¿HG
positions on the unit base. Also support the outdoor unit at four
points so that it cannot slip sideways.
- Safely dispose of the packing materials.
3DFNLQJPDWHULDOVVXFKDVQDLOVDQGRWKHUPHWDORUZRRGHQ
SDUWVPD\FDXVHVWDEVRURWKHULQMXULHV
- Tear apart and throw away plastic packaging bags so that chil-
dren can not play with them. If children play with a plastic bag
ZKLFKZDVQRWWRUQDSDUWWKH\IDFHWKHULVNRIVXIIRFDWLRQ