3SPECIFICATIONS
Model PUMY-P112VKM1(-BS) PUMY-P125VKM1(-BS) PUMY-P140VKM1(-BS)
Power source 1-phase 220/240 V,50Hz
Cooling capacity
(Nominal) kW*112.5 14.0 15.5
kcal/h*110,750 12,040 13,330
BTU/h*142,650 47,768 52,886
Power input kW 2.79 3.46 4.52
Current input A 12.87/ 12.32/ 11.80 15.97/ 15.27/ 14.64 20.86/ 19.95/ 19.12
COP kW/kW 4.48 4.05 3.43
Temp. range of
cooling Indoor temp. W.B. 15 to 24 °C
Outdoor temp. D.B. −5to46°C
Heating capacity
(Nominal) kW*214.0 16.0 18.0
kcal/h*212,040 13,760 15,480
BTU/h*247,768 54,592 61,416
Power input kW 3.04 3.74 4.47
Current input A 14.03/ 13.42/ 12.86 17.26/ 16.51/ 15.82 20.63/ 19.73/ 18.91
COP kW/kW 4.61 4.28 4.03
Temp. range of
heating Indoor temp. D.B. 15 to 27 °C
Outdoor temp. W.B. −20to15°C
Indoor unit
connectable Total capacity 50 to 130% of outdoor unit capacity
Model / Quantity Citymulti 15 - 125/ 9 15 - 140/ 10 15 - 140/ 12
Branch box 15 - 100/ 8 15 - 100/ 8 15 - 100/ 8
Mixed system
15 - 125(*3)/ 10 15 - 140/ 10*415 - 125/ 10*4
Sound pressure level
(measured in anechoic room) dB <A> 49/ 51 50/ 52 51/ 53
Power pressure level
(measured in anechoic room) dB <A> - - -
Refrigerant
piping diameter Liquid pipe mm (in) 9.52 (3/8)
Gas pipe mm (in) 15.88 (5/8)
FAN *2 Type x Quantity Propeller Fan x 2
Airowrate m3/min 110
L/s 1,833
cfm 3,884
Control, Driving mechanism DC control
Motor output kW 0.06+0.06
External static press. 0
Compressor Type x Quantity Scroll hermetic compressor x 1
Manufacture Mitsubishi Electric Corporation
Starting method Inverter
Capacity control % Cooling 26 to 100
Heating 20 to 100 Cooling 24 to 00
Heating 18 to 100 Cooling 21 to 100
Heating 17 to 100
Motor output kW 2.9 3.5 3.9
Case heater kW 0
Lubricant FV50S(2.3litter)
Externalnish Galvanized Steel Sheet
Munsell No. 3Y 7.8/1.1
External dimension HxWxD mm 1,338 x 1,050 x 330(+25)
in 52-11/16 x 41-11/ 32 x 13 (+1)
Protection
devices High pressure protection High pressure Switch
Inverter circuit (COMP./FAN) Overcurrent detection, Overheat detection(Heat sink thermistor)
Compressor Compressor thermistor, Over current detection
Fan motor Overheating,Voltageprotection
Refrigerant Type x original charge R410A 4.8kg
Control ElectronicExpansionValve
Net weight kg (lb) 123 (271)
Heat exchanger Cross Fin and Copper tube
HIC circuit (HIC: Heat Inter-Changer) HIC circuit
Defrosting method Reversed refrigerant circuit
Drawing External BK01N346
Wiring BH78B813
Standard
attachment Document Installation Manual
Accessory Grounded lead wire x2
Optional parts Joint:CMY-Y62-G-E
Header: CMY-Y64/68-G-E
Branch box: PAC-MK30/50BC
Remarks Unit converter
kcal/h = kW × 860
BTU/h = kW × 3,412
cfm = m3/min x 35.31
lb = kg/0.4536
Abovespecicationdatais
subject to rounding
variation.
*1Nominal cooling conditions *2Nominal heating conditions
Indoor :
27 °C D.B./19 °C W.B. [81 °F D.B/66 °FW.B.]
20 °C D.B. [68 °FD.B.]
Outdoor : 35 °C D.B. [95 °FD.B.]
7°C DB/6°C W.B. [45 °F D.B./43 °FW.B.]
Pipe length : 7.5m[24-9/16ft] 7.5m[24-9/16ft]
Level difference : 0m[0ft] 0m[0ft]
Note : 1. Nominal conditions *1, *2are subject to ISO 15042.
2.Duetocontinuingimprovement,abovespecicationsmaybesubjecttochangewithoutnotice.
*3 Up to P100 when connecting via branch box.
*4 Up to 11 units when connecting via 2 branch boxes.