manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Mizuho
  6. •
  7. Medical Equipment
  8. •
  9. Mizuho 07-863-02CE User manual

Mizuho 07-863-02CE User manual

1/2
MES-CK07-863-01CEEN-0
PREPARED: (2018-04-03) (Version 1)
Instructions for Use
Trade Name: Micro Jeweler Forceps
Warning
Please read these instructions carefully prior to using this
product. Product should be used according to these
instructions and pay close attention to the safety of
patients. Not doing so may give rise to serious problems
or adverse events.
For the US market
Do not reuse the device when it is used on a patient with
or suspected of having Creutzfeldt-Jakob Disease (CJD)
or variant CJD (vCJD).
For the markets outside the US
When the device is used on a patient with or suspected of
having CJD or vCJD, make sure to adhere to the most
recent and updated restrictions available in each country
and/or region for its reuse. Be cautious of the possibility
of secondary infection. Refer to www.a-k-i.org or AAMI
Standard ST79 for more information related to cleaning
and sterilization.
Contraindication / Prohibition
1. Use for intended purpose only
Incorrect use can cause breakage of this product. Never
use as a lever or twist the unit with force. Doing so may
cause failure of the internal mechanism or otherwise
damage the instrument.
2. Prohibition of use of chemicals
Avoid exposing this product to chemicals. Doing so could
damage this product due to corrosion.
3. Prohibition of secondary processing of this product
Do not apply any secondary processing to this product.
For example, do not apply impacts or vibration markings
to the surface of this product. Doing so could break this
product.
4. Handle with care
Handle this product with care, as it can be deformed or
damaged. Rough handling could significantly reduce the
service life of devices and appliances.
5. Prohibition of use of polishing powder and wire wool
When cleaning this product, do not attempt to polish its
surfaces with rough polishing powder or wire wool. This
could cause scratches on the surface of this product and
result in rust or corrosion.
6. Prohibition of use of household detergents
Use only medical detergents to clean this product. Do not
use any household detergent. Washing this product with
an improper detergent could result in rust or corrosion.
Shape/Structure
Code No. Product Description
07-863-01CE Micro Jeweler Forceps
12cm, Strong Tip #1 CE
Code No. Product Description
07-863-02CE
Micro Jeweler Forceps
12cm, Strong Tip #2 CE
Code No. Product Description
07-863-03CE
Micro Jeweler Forceps
12cm, Very Fine Tip #3 CE
Code No. Product Description
07-863-04CE
Micro Jeweler Forceps
11cm, Very Fine Tip #4 CE
Code No. Product Description
07-863-05CE
Micro Jeweler Forceps
11cm, Extra Fine Tip #5 CE
Code No. Product Description
07-863-08CE
Micro Jeweler Forceps
14cm, Long Tip #8 CE
Material: Stainless steel
Intended Purpose
This device is a surgical instrument to grasp an object with
the 2 blades placed symmetrically.
Instructions for use
Before using this product, inspect, wash, and sterilize in
accordance with these instructions (See the requirements
relating to maintenance and inspection).
Cautions/Warnings
1. Warning
Device must be sterilized by users in accordance with
sterilization procedures or the validated sterilization
conditions which validity is proven by medical organizations
in each country or region.
Be sure to read this instruction manual before using this product.
Keep this manual available for reference when needed.
2/2
2. Defect/Adverse event
Defect
-Corrosion or pitting caused by use of chemicals
-Damage or breakage caused by the corrosion or pitting
-Scissors may not cut properly due to damaged tip of the
blades.
Adverse event
-Broken pieces of metal from the damaged instrument
falling into the patient.
Storage/Life
1. Please store the device in normal ambient temperature
areas. Do not store in areas of high humidity where the
temperature may dramatically vary causing condensation.
Do not store on or near chemicals as the chemicals may
cause damage to the device.
2. Service life of this product: 7 years
(Subject to following manufacturer's specified
maintenance, inspection and proper storage
requirements)
Maintenance/Inspection
1. Check prior to each use
Operational and functional checks
Conduct daily and pre-operation checks of this product to
make sure that it functions properly.
2. Check after each use
(1) Immediately wash with clean water.
(1)-1 If exposed to bleach or antiseptic solutions, wash
and rinse with clean water immediately and immerse
in neutral enzyme detergent to remove any bleach
or antiseptic solution, which may contain chlorine or
iodine and can damage the instrument. Manually
remove contaminated matter by hand or with an
ultrasonic-cleaner.
(1)-2 Further remove any remaining contamination with a
soft nylon brush.
(1)-3 Select a proper detergent for each decontamination
method and maintain appropriate density and
handling.
(1)-4 Use a soft towel, a soft nylon brush or a water jet for
cleaning.
(1)-5 To avoid damage, do not use a metal brush, coarse
polishing agents, or apply excessive force when
handling the device.
(1)-6 Only use distilled water or deionized water (reverse
osmosis) to wash this product.
(1)-7 Only use fully deionized water (reverse osmosis) for
the final rinse.
It is recommended to use a washer-disinfector for
this device.
Thermal Disinfection can be used by following the
manufacture's defined parameters.
Thermal Disinfection Band: 90-93°C/194.0-199.4°F,
5-10 minutes (A0 value: 3000-12000)
(reference EN ISO 15883-1)
(2) Fully dry this product immediately after washing it.
Do not leave it wet for a longer time than necessary as
residual water may damage the instrument.
(3) Only use distilled or deionized water
Use distilled or deionized water to wash this product.
Residual chlorine and organic matters in tap water may
cause staining and/or rust and may damage the
instrument.
(4) Use a water-based, anticorrosive lubricant
Lubricating oil is completely removed by washing. After
washing this product, apply a water-based, anticorrosive
lubricant prior to sterilization.
3. Sterilization
Device must be sterilized by users in accordance with our
recommended sterilization procedures or the validated
sterilization conditions which validity is proven by medical
organizations in each country or region.
Our recommended sterilization parameters are as follows.
For the US market
FDA has not approved or cleared medical devices,
including sterilizers, for the intended use of reducing the
infectivity of TSE agents (i.e., prions).
For the markets outside the US
When the device is used on a patient with or suspected of
having CJD or vCJD, make sure to adhere to the most
recent and updated restrictions available in each country
and/or region for its reuse.
Maintenance and check by agents
For safety use of this instrument, conduct periodic checks by
the manufacturer or the agent recognized by the
manufacturer. Maintenance and check by other agents could
cause the adverse events and the decrease of the
performance and the function. To schedule the periodic
check, contact your local distributor or the manufacturer.
Packing
1 piece per pack
Matters related to warranty period
MIZUHO Corporation will repair defective parts of this
product without charge for one year from the date of
delivery/installment except for cases of damage caused by a
third party’s repair, act of nature, improper use or intentional
damage. All other warranty terms and conditions are subject
to regulations of MIZUHO Corporation.
Name and address of manufacturer
MIZUHO Corporation
3-30-13 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
http://www.mizuho.co.jp
Authorized Representative Europe
Emergo Europe B.V.
Prinsessegracht 20, 2514 AP, The Hague,
The Netherlands
Sterilization
method
Pre-vacuum steam sterilization
(Autoclave sterilization)
Sterilization
conditions
Sterilization
temp.
Retention time
132°C / 269.6°F 4 min
134°C / 273.2°F 3 min

This manual suits for next models

4

Other Mizuho Medical Equipment manuals

Mizuho 07-868-01 User manual

Mizuho

Mizuho 07-868-01 User manual

Mizuho SPL-331 User manual

Mizuho

Mizuho SPL-331 User manual

Mizuho MOT-VS700 Series User manual

Mizuho

Mizuho MOT-VS700 Series User manual

Mizuho MOT-VE100 User manual

Mizuho

Mizuho MOT-VE100 User manual

Mizuho MST-7300B User manual

Mizuho

Mizuho MST-7300B User manual

Mizuho SUGITA AVM Microclip II CASE B User manual

Mizuho

Mizuho SUGITA AVM Microclip II CASE B User manual

Mizuho 08-068-31 User manual

Mizuho

Mizuho 08-068-31 User manual

Mizuho MES-CK08-064-23EN-0 User manual

Mizuho

Mizuho MES-CK08-064-23EN-0 User manual

Mizuho Sugita T2 Clip Tray Series User manual

Mizuho

Mizuho Sugita T2 Clip Tray Series User manual

Mizuho 07-870-03CE User manual

Mizuho

Mizuho 07-870-03CE User manual

Mizuho MST-7201B User manual

Mizuho

Mizuho MST-7201B User manual

Mizuho Allegro 6800 User manual

Mizuho

Mizuho Allegro 6800 User manual

Mizuho Knee Rests User manual

Mizuho

Mizuho Knee Rests User manual

Mizuho MOT-3602X User manual

Mizuho

Mizuho MOT-3602X User manual

Mizuho 7200B User manual

Mizuho

Mizuho 7200B User manual

Mizuho MOC-142 User manual

Mizuho

Mizuho MOC-142 User manual

Mizuho Seat Extension User manual

Mizuho

Mizuho Seat Extension User manual

Mizuho MOT-1602BW User manual

Mizuho

Mizuho MOT-1602BW User manual

Mizuho MOT-VE100 User manual

Mizuho

Mizuho MOT-VE100 User manual

Mizuho MOT-VS500DK User manual

Mizuho

Mizuho MOT-VS500DK User manual

Mizuho MOT-VS700 Series User manual

Mizuho

Mizuho MOT-VS700 Series User manual

Mizuho SMART FIX User manual

Mizuho

Mizuho SMART FIX User manual

Mizuho 5348 User manual

Mizuho

Mizuho 5348 User manual

Mizuho MST-7300B User manual

Mizuho

Mizuho MST-7300B User manual

Popular Medical Equipment manuals by other brands

Climax Technology PB-15 manual

Climax Technology

Climax Technology PB-15 manual

Invacare microAIR MA90 Series Owner's operator and maintenance manual

Invacare

Invacare microAIR MA90 Series Owner's operator and maintenance manual

AKRUS ak 5003M user manual

AKRUS

AKRUS ak 5003M user manual

lopital Lotus Instructions for use

lopital

lopital Lotus Instructions for use

Cobi Rehab Bariatric user manual

Cobi Rehab

Cobi Rehab Bariatric user manual

Gima DMS 300-BTT02 user manual

Gima

Gima DMS 300-BTT02 user manual

Ossur Miami LSO Instructions for use

Ossur

Ossur Miami LSO Instructions for use

Care of Sweden Optimal series user manual

Care of Sweden

Care of Sweden Optimal series user manual

CAE Ares user guide

CAE

CAE Ares user guide

Orliman C-45 Instructions for use

Orliman

Orliman C-45 Instructions for use

Omron Focus PM710-M instruction manual

Omron

Omron Focus PM710-M instruction manual

Clinton ALPHA Series Assembly instructions

Clinton

Clinton ALPHA Series Assembly instructions

Rini R5 user manual

Rini

Rini R5 user manual

Inogen One G3 user manual

Inogen

Inogen One G3 user manual

idi MDS quick start

idi

idi MDS quick start

Bestcare SA400HE manual

Bestcare

Bestcare SA400HE manual

Playcore SPECTRUM Aquatics Motion Trek 350 Deluxe manual

Playcore

Playcore SPECTRUM Aquatics Motion Trek 350 Deluxe manual

Stryker Quantum LED Surgical Headlights Instructions for use

Stryker

Stryker Quantum LED Surgical Headlights Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.