MMP-100F/30B/DL/3
JIAKARIDOWNLIGHT
InstallationGuideLightingFixture
Φ100
Ceilingcutout
kg
Weight
0.67
Ceiling
thickness
9〜25
mm
Lamp
Inputvoltage
Inputcurrent
Driver
Soldseparately
COB
35.8V
0.9AMAX
Pleaseuseconstantcurrentdriver.
Thefixtureisforindooruseonlyingeneralconditions.
Cannotbeusedfollowingconditions(Causesoffalling,electrocutionandfire)
●Ambienttemperatureunder0℃andover35℃
●Highhumidity
●Outside
●Onthefloor
●Insulatedinsideofceiling
●Vibratedorshockedareas
●Areasgetdirectsunlight
●Inclined,unevensurface
●
Ceilingwhichcanʼtholdthefixtureweight
●Onthewall
●
Placesaffectedbywindorair-conditionermachine
●Nearfire
●
Dustyareas,corrosivegasoutbreaksareas
Before
installation
Forelectric
wiring
Atlighting
fixture
installation
Warning
Warning
Warning
Warning: Failuretoinstallthefixtureproperlycouldresultinpersonalinjury.
Failuretoinstallthefixtureproperlycouldresultinpropertydamage.
:Prohibited
:Strictobservance
Caution:
Caution
Caution
Toinstallthefixturesafely《Readcarefullyandfollowalltheinstructionsintheguide》
Pleasefollowthefixturesʼindicationorspecificationforthedistanceofirradiatedarea.
(Causesofchangeinshape,changeincolorofirradiatedobjects)
Pleasecontactifyouarenotabletojudgewhetherinstallation
environmentissuitabletotheplacesornot.
Onlyqualifiedpersonmayworkonelectricwiringandequipment.(Causeofaccidents)
Besurepowersupplyvoltageiswithin±6%mentionedinratingplateortheguide.(Causesofshortlifeoflamps・electrification・fire)
Besureallthewiresandcodesarenotdamaged.(Causesoffalling・damage)
Pleasefollowthefixturesʼinstructionorthisguidetoinstallthefixtureandlamp.(Causesoffalling・electrification・fire)
Switchoffthepowerwheninstallingthelamp.(Causesofelectrification)
Donottouchthefixturewhenswitchisonorjustturnofftheswitchbecauseofhightemperature.
Donotputorcoverthefixturebyanycloths,papers,orinsulators.(Causesofnotlighting・fire)
Donotplaceanymetallicorflammableobjects.(Causeofelectrification・fire・brokenfixture)
Makesuretoinstallallthepartsoffixturesbesidesinstallationandmountingpartswillnottouchwithany
objectsbothinsideandoutsideofceilingsuchaslightingtrack,etc.(Causesoffalling・electrification・fire)
Donotdismountorremodelfixtures.(Causeofelectrification・fire・falling・brokenfixtures)
Donotoperatewithwethands.
Ifyousmellsmoke,seesmoke,orfindanythingunusual,pleaseturntheswitchoffandaskconstruction
companiestorepair.(Causeofelectrification・fire)
Makesuretheconstructionwillnotaffectanyfirepreventionsystemssuchassprinklerbyheatfromthefixture.
(Causesofimproperoperation)
Usealternatingcurrent.Pleasefollowratingplateoffixturesforpowersupplyfrequency.
(Causeofelectrification・fire)(50Hz・60Hzcommonuseforballastsandincandescentlampfixtures)
20cm〜
10cm〜
Insulator
InsulatorInsulator
InstallationGuide LightingFixture
RemovableSlit
−BLACK
+RED
110
9〜25
135.5
2.5
Thisfixturecanonlybeinstalledonahorizontalceiling.