Monnit Serial MODBUS User manual

Information to Users
This equipment has been tested and found to comply with the limits for a Class B digital
devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communi-
cations. However, there is no guarantee that interference will not occur in a particular instal-
lation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one of more of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING:
authority to operate the equipment.
RF EXPOSURE WARNING: To satisfy FCC RF exposure requirements for mobile transmit-
ting devices, a separation distance of 20 cm or more should be maintained between the
antenna of this device and persons during device operation. To ensure compliance, opera-
tions at closer than this distance are not recommended. The antenna used for this transmit-
ter must not be co-located in conjunction with any other antenna or transmitter.
Inside the Box
Monnit Wireless Sensors
Serial MODBUS
(RTU/ASCII) Gateway
Quick Start Guide

Features
Example Network Integration
Monnit Serial MODBUS Gateway Quick Start
Pump
Control
Level
Valve Control
SCADA
E-1
Activity
PLC
Monnit Serial
MODBUS GW
SMG
Voltage
Temp
Water Leak
Pump
Tank

Attach Hardware
SMG 5-Wire Connector
n
Red - 4.5 - 36 VDC
Black - Power Ground
Orange - Transmit
White Signal Ground
Green - Receive

Verify Communication Settings
Change Communication Settings
o
p

Register Name Address Description
Value Represented Baud Selected
Value Represented Meaning

Register Sensors To SMG
q

(READ-ONLY)

Register Name Address Register Name Address
Bring Sensors Online
Read / Interpret Sensor Data
r
s
+
_

Record Name Address Record Name Address

C1

Troubleshooting

Other manuals for Serial MODBUS
1
Table of contents
Other Monnit Gateway manuals

Monnit
Monnit MonnitLink User manual

Monnit
Monnit Ethernet Gateway Series User manual

Monnit
Monnit ALTA XL User manual

Monnit
Monnit Serial MODBUS User manual

Monnit
Monnit MonnitLink CGW2 User manual

Monnit
Monnit MNG2-9-EGW-CCE User manual

Monnit
Monnit ALTA EGW4 User manual

Monnit
Monnit MonnitLink User manual

Monnit
Monnit ALTA LTE International Gateway User manual

Monnit
Monnit Wireless Sensors and Ethernet Gateway User manual