mr. steam W500 Manual

mr
.steam
®
towelwarmers
Electric & Hydronic Models
Installation & O erating Instructions
Model _________________
Serial #________________
PUR 103852 Rev. 12/09

mr.steam
®
towelwarmers
Table of Contents
___________________________
Electric Models . . . . . . . . . . . . . . . . . . . . .1
General Information & Specifications . . . . . . . . . . . . .2
Wall Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Mounting Dimensions . . . . . . . . . . . . . . . . . . . . . . . .4
Installation
Models 542, 552, 554, 562, 572, 634, . . . . . . . . . . . .5
Model 842 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Models 500 & 510 . . . . . . . . . . . . . . . . . . . . . . . . .7
Model 556 & 856 . . . . . . . . . . . . . . . . . . . . . . . . . .8
Electrical Connections . . . . . . . . . . . . . . . . . . . . . .9-10
Optional Programmable Timer . . . . . . . . . . . . . . . . . .11
____________________________
Hydronic Models . . . . . . . . . . . . . . . . . .12
General Information & Pre-Installation . . . . . . . . . . .13
Wall & Plumbing Preparation . . . . . . . . . . . . . . . . . .14
Installation, Operation & Maintenance . . . . . . . . . . .15
___________________________
IMPORTANT NOTE:
As you follow these instructions, you will notice warning
and caution symbols. This blocked information is important for the safe and
efficient installation and operation of this Towel Warmer. These are types of
potential hazards that may occur during this installation and operation:
states a hazard may cause serious injury or death
if precautions are not followed.
signals a situation where minor injury or product damage
may occur if you do not follow instructions.
IMPORTANT NOTE:
This highlights information that is especially relevant to a problem-free installation.
All information in these instructions is based on the latest product information
available at the time of publication. Sussman-Automatic Corporation reserves the
right to make changes at any time without notice.
!CAUTION
!WARNING
Sussman-Automatic
Corporation®
www.mrsteam.com
pur 103852 rev 11.1/08
43-20 34th Street
Long Island City, NY 11101
Tel: 1-800-76 STEAM
Fax: (718) 472-3256 Western
9410 S. La Cienega Blvd.
Inglewood CA 90301
1-800 -72 STEAM
Fax: (310) 216-2944

W500 W510
W542 W552 W554
W556 W562 W572
W634 W842 W856
mr.steam
®
towelwarmers
Models W500, W510, W542, W552, W554,
Electric Models W556, W562, W572, W634, W842, W856
___________________________
Model
___________________________
Serial #

mr.steam®towelwarmers Electric Models
_________________________________________________________________
Installation and Operating Instructions
2
HOMEOWNER:
__________________________________________
THANK YOU for selecting Mr.Steam Towel Warmer, the perfect
addition to bathrooms, family spas, and exercise rooms within
your home. Our products have long been a standard for quality
and comfort, and we are sure that you will experience contin-
ued enjoyment from the Towel Warmer you have purchased by
following these simple instructions.
TOWEL WARMERS ARE HOT! The Towel
Warmer is an electrical heating appliance, intended only for
indoor residential applications and, as such, should be
installed and used with certain precautions for your safety.
1. INSTALLATION PROCEDURES FOR PERMANENTLY-WIRED
WALL-MOUNTED UNITS MUST BE ACCOMPLISHED BY
QUALIFIED PERSONNEL IN STRICT ACCORD WITH
APPLICABLE NATIONAL AND LOCAL BUILDING AND
ELECTRICAL CODES.
2. DO NOT place TOWEL WARMER units inside a shower, sauna
or steam room enclosure or any other wet location or with
elevated temperatures.
3. CAUTION is advised when Towel Warmer is accessible to
children.
4. For the ultimate ease in use, a dedicated wall switch or
timer can be used to control the TOWEL WARMER unit.
Contact Mr.Steam for an in-wall 24-hour-7 day timer
(PN W-103588) Note: All switches and control devices must
be installed on the load (black) side of the Towel Warmer
circuit in compliance with the National Electric Code and
Local Codes. (see page 11 for installation instructions)
IMPORTANT:
The finish of your Towel Warmer can be
protected and maintained by an occasional wiping with a soft,
non-abrasive, damp cloth and lightly polished, thereafter, with
a soft dry cloth when the Towel Warmer is cold. Under no cir-
cumstances should abrasive cleaning powders, metal polish or
chlorine-based cleaners be used on any part of this product.
IMPORTANT:
This appliance is intended for towels washed
in water. Fabrics that contain soap or detergent residue may
show what appears to be scorch marks. However this is simply
the discoloration of the residue. The Towel Warmer unit does
not reach sufficient temperature to scorch fabric. We are not
responsible for discoloring or damage of any fabrics.
This picture shows the recommend
method of draping a towel on a towel
warmer. Ensure as much as possible of
the towel's surface is touching the
towel warmer to ensure fast even warm-
ing of the towel.
TOWEL WARMER SPECIFICATIONS
_____________________________________________________________
Model No. Dimensions (inches) Amps Volts/Phase Weight (lbs.)
W x H x D
_____________________________________________________________
W500 22.5 x 25 x 5 0.83 120/1 20
_____________________________________________________________
W510 20.5 x 18.5 x 5 0.58 120/1 20
_____________________________________________________________
W542 23.75 x 26 x 5.25 1.25 120/1 25
_____________________________________________________________
W552 23.5 x 25.25 x 13 1.67 120/1 40
_____________________________________________________________
W554 23.75 x 21.5 x 13 1.67 120/1 30
_____________________________________________________________
W556 21.75 x 34 x 10 1.25 120/1 25
_____________________________________________________________
W562 23.5 x 23.25 x 5.25 1.67 120/1 30
_____________________________________________________________
W572 23.75 x 36 x 5.25 1.25 120/1 30
_____________________________________________________________
W634 19.5 x 27.5 x 7.25 1.67 120/1 25
_____________________________________________________________
W842 23 x 24.5 x 4.75 0.83 120/1 25
_____________________________________________________________
W856 21.5 x 31 x 9.875 1.25 120/1 30
_____________________________________________________________
INSTALLER:
_________________________________________________________
READ THIS ENTIRE INSTRUCTION MANUAL THOROUGHLY BEFORE BEGINNING
INSTALLATION. LEAVE THESE INSTRUCTIONS WITH HOMEOWNER.
BE CERTAIN ELECTRICITY IS SHUT OFF AT MAIN PANEL
BEFORE WIRING OR SERVICING YOUR TOWEL WARMER. Follow instructions
to make certain your Towel Warmer is properly attached to the wall. FAIL-
URE TO FOLLOW THESE STEPS COULD RESULT IN HAZARDOUS CONDITIONS.
To avoid possible fire hazard, the Towel Warmer must
remain in its intended position. MOUNT THIS UNIT ONLY AS SHOWN IN
THESE INSTRUCTIONS.
1. Install in accordance with
National and local codes.
2. Do not locate in shower stall or
near shower spray.
3. Do not locate within the show-
er or tub zone.
4. All models are to be protected by dedicated
and suitably rated GFCI circuit breaker or equal.
TO ENSURE CORRECT OPERATION OF YOUR TOWEL WARMER, PLEASE FOLLOW
ALL THE INSTRUCTIONS CAREFULLY, OBSERVING THE "CAUTION" NOTATIONS
FOR EACH STEP.
Inspect Towel Warmer
Unpack the Towel Warmer carefully to avoid any damage or loss of any part.
When opening the box be sure that the parts are not accidentally discarded.
Towel Warmers are shipped in specially designed shipping cartons. The entire
surface of the Towel Warmer is hand-wrapped to protect the finish. It is your
responsibility to immediately inspect for any damage.
For illustrative purposes only
!WARNING
!WARNING
!WARNING
!CAUTION
Shower/Tub
Zone
Do not locate the
towel warmer within
the shower/tub zone

mr.steam®towelwarmers Electric Models
_________________________________________________________________
Installation and Operating Instructions
3
WALL PREPARATION
• DO NOT mount the Towel Warmer without
providing structurally secure headers as shown.
• DO NOT mount the Towel Warmer directly to sheet
rock or any other non-structural surface.
• Use longer fasteners as required if the finished wall surface
prevents adequate mounting with the screws provided.
• Provide a clearance hole in the lower header as required
to route field wiring to the Towel Warmer wiring box.
If a single gang electric box has been roughed-in, install cover plate
PN103877. See part numbers below for decorative finish information.
DO NOT install the Towel Warmer without these instructions.
Cover Plate Part Numbers & Decorative Finishes:
Polished Chrome 103877PC
Polished Brass 103877PB
Polished Nickel 103877PN
Pewter 103877P
Satin Nickel 103877SN
Polished Gold 103877 PG
Satin Gold 103877SG
Antique Brass 103877AB
Oil Rubbed Bronze 103877ORB
IMPORTANT NOTE:
Towel Warmers may have small dimensional
variations and must be measured prior to installation.
For Technical Service Assistance:
East Coast Tel: 1-800-767-8326
West Coast Tel: 1-800-727-8326
Lower Header (Z)
Upper Header (Z)
Lower Header (Z)
Upper Header (Z)
Wiring Box
X
Y
Wiring
Box
Finished
wall surface
Finished
wall surface
Y
X
!CAUTION
!WARNING
MOUNTING DIMENSIONS (inches)
MODEL X(min) Y Z (min)
(Header horizontal length) (Header vertical length) (Header size)
W 500 5 22 5⁄82 x 6
W 510 5 161⁄82 x 6
W 542 231⁄4243⁄42 x 6
W 552 231⁄4233⁄42 x 6
W 554 231⁄4205⁄16 2 x 6
W 562 231⁄4233⁄16 2 x 6
W 572 231⁄4243⁄42 x 6
W 634 19 271⁄82 x 6
W 842 23 231⁄42 x 6
Other manuals for W500
1
This manual suits for next models
10
Table of contents
Other mr. steam Food Warmer manuals