Ultra Elite-H Mask – Negative Pressure 5
Safety Regulations
GB
1 Safety Regulations
1.1 Correct Use
The mask/helmet combination series Ultra Elite-H/F1 with standard thread connection according to
EN 148-1 are not complete respiratory protective devices by themselves, but serve as facepieces in
accordance with DIN 58610 [EN 443 and EN 136 CL3+ with the exception of selection 7.11] for use
with respiratory filters, compressed air breathing apparatus, fresh air hose breathing apparatus and
compressed air line breathing apparatus.
The mask as part of a respiratory protective device ensures an appropriately tight fit of the user’s face
against the ambient atmosphere.
The helmet as part of the whole protective device ensures the protection of the upper half of the head
mainly against the effects of impact, penetration, heat and flames during firefighting.
The masks can only be used in conjunction with following MSA GALLET helmets:
The instructions for use for the helmets have to be regarded.
The mask/helmet combination series Ultra Elite-H/F2 X-TREM with standard thread connection
according to EN 148-1 are not complete respiratory protective devices by themselves, but serve as
facepieces in accordance with DIN 58610 [EN 136 CL3+ with the exception of selection 7.11].
WARNING!
The helmet type F2 X-TREM is not certificated according to EN 443. Therefore this helmet in combi-
nation with the mask must not be used for firefighting in buildings and structures.
The mask/helmet combination provides the function of head protection and respiratory protection in
one system.
WARNING!
According to the European directive 89/656/EWG it has to be verified before first use of the mask that
a correct size has been chosen [proper tight fit], that the mask can be worn in combination with other
protective equipment [for example a protective jacket], that it is a correct choice for the conditions at
the particular place of use and that it fulfils the ergonomic requirements.
It is imperative that this operating manual be read and observed when using the device. In particular,
the safety instructions, as well as the information for the use and operation of the device, must be care-
fully read and observed. Furthermore, the national regulations applicable in the user's country must be
taken into account for a safe use.
WARNING!
This product is supporting life and health. Inappropriate use, maintenance or servicing may affect the
function of the device and thereby seriously compromise the user's life.
Before use the product operability must be verified. The product must not be used if the function test
is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA
spare parts have not been used.
• F1SF [EN 443:2008]
• F1E [EN 443:2008] • Gallet F1 XF [EN 443:2008]