SineBravo Operators Manual
9
Advice on Application of Electrodes
Make sure that SineBravoLVWXUQHGRuQRLQGLFDWLRQYLVLEOHRQWKH/&’GLVSOD\
Now connect the single poled ends of the lead wires with the electrodes.
The output plugs of the electrode lead wires will be plugged into the channels A or B of the
SineBravo. The reference lead wire will be connected to its jack as well.
)XUWKHUPRUHPDNHVXUHWKDWDOOSOXJV¿WFRPSOHWHO\LQWRWKHHOHFWURGHVRFNHWVDVZHOODVWKH
device sockets.
If you are using a probe, lubricate it with water or a gel suitable for electrotherapy.
Now place the electrodes or the probe according to the instructions of your doctor or
physiotherapist. The self-adhesive skin electrodes are provided with a sticky gel and can be re-
used after removal from the skin. Replace these electrodes when the adhesive force is weak.
Electrodes which are damaged due to careless handling may not be used.
Electrodes with damaged lead wire insulation (e.g. visible copper wire) may not be used.
Electrodes with damaged, missing or stained aluminium coating or carbon layer, also with
LQVXvFLHQWDGKHVLYHJHOPD\QRWEHXVHG
Electrodes may not be altered or tampered with (e.g. by scissors or other tools).
Do not pull the electrodes by force on the electrode lead wire. To remove the electrodes from
the skin, please lift the electrode at the rim towards the middle.
’RQRWXVHHOHFWURGHVZLWKRLQWPHQWVRUFUHDPVHVSHFLDOO\ZKLFKHQKDQFHWKHEORRGRZRUDFW
as local anaesthesia).
Apply the electrodes on clean and healthy skin only.
In the case of strong bodily hair growth, the hair should be shaved or shortened with scissors.
Neither stretch the skin nor the electrodes when applying the electrodes.
For standard treatment we recommend the use of our self-adhesive electrodes with a minimum
area of 40x40 mm. This size is suited for the reference electrode as well. For best results please
make sure that the reference electrode is placed on a bone near the treatment area, not on
muscles.
)RUWUHDWPHQWRIWKHPXVFOHVRIWKHSHOYLFRRUZHUHFRPPHQGWKHXVHRIRXUYDJLQDO
(IncoProbe V) or rectal-probes (IncoProbe R).
If using a probe, please clean it carefully before and after use with a mild detergent (without
alcohol) and ensure the probe is rinsed thoroughly to remove all cleaning residues. Ensure the
connectors are not submerged in water as they may corrode. Ensure the probe is completely dry
before storage.
After all electrodes have been removed, wash the skin with mild soap and rinse thoroughly.
Then dry your skin.
All electrodes or probes are for single person use only.
6NLQHOHFWURGHVDVZHOODVSUREHVFDQFRQWDLQDPRXQWVRIQLFNHO$OOHUJ\VXuHUHUVVKRXOGFKHFN
this before using. Should skin irritation occur whilst using the SineBravo, please interrupt the
application and inform your doctor, so that an allergic reaction can be excluded.