manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. MULTISPAN
  6. •
  7. Timer
  8. •
  9. MULTISPAN UTR - 1044 User manual

MULTISPAN UTR - 1044 User manual

OPERATING MANUAL
UNIVERSAL TIMER
UTR - 1044/2044/444
OPERATING MANUAL
UNIVERSAL TIMER
UTR - 1044/2044/444
Technical Specification
Notes:
1). For safely purpose, key function are designed in such a way that operator will not go into
detailed parmeter setting (Previously Set) function. In this situation, in LOCK parameter,
has to be selected. If previously set parameters are to be changed, then any operator
has to select
2). In Cycling Mode, parameter will be displayed.
3). POWER ON () : Timer starts counting as soon as it gets power supply.
4). By default ON delay Mode is provided. Please refer programming guide to change to OFF
delay or Cycling Mode.
1). Turn ON instrument. SET time according to your requirment.
2). In running mode, upper display indicates current TIME value and lower display shows SET
time value. Relay ON or OFF controls depends on set time.
3). Relay operation is according to selection of Delay ON or Delay OFF in programming menu.
4). In cycling mode, relay will turn on for ON time (time-1) & relay will turn off for OFF time
(time-2) and this ON-OFF process will continue.
5). To reset the time, press Reset Key.
YES
NO
UNT- UNT TIME MEMO1, -2 &
Working
Page - 1 www.multispanindia.com
1) Display : a) Upper : 4 digit, 0.56’’, 7 segment LED
b) Lower : 4 digit, 0.4’’, 7 segment LED
2) Output : 1 relay, 2 C/O, 230V AC, 5 Amp.
3) Supply : 110V to 250V AC, 50 Hz smps
96 X 96 X 50 mm 72 X 72 X 60 mm 48 X 48 X 90 mm
UTR - 1044 UTR - 444
R1
R2
Universal Timer UTR-1044
TIME
SET TIME
1 2 3 4
1 2 3 4
UTR - 2044
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Page - 2
www.multispanindia.com
PARAMETER MODE
press key
SET
ENT
press key
SET
ENT
press key
SET
ENT
press key
SET
ENT
press key
SET
ENT press key
SET
ENT
press key
SET
ENT
press key
SET
ENT
press SET/ENT key
press SET/ENT key
press SET/ENT key
Lock Mode : yes / no
L O C KL O C K
Y E S N O
F U N C
D L O F D L O N C Y O F C Y O N
N O C L
SELECT BY
key
SELECT BY
SELECT BY
key
key
SELECT BY
key
SELECT BY
key
SELECT BY
key
SELECT BY
key
SELECT BY
key
Select:
Cycling Mode
delayed ON or
delayed OFF or
9 999 SEC.9 999 SEC.9 999 SEC.9 999 SEC.
9 999 SEC.9 999 SEC.
99 9 min SEC..599 9 min SEC..599 9 min SEC..599 9 min SEC..5
99 9 min SEC..599 9 min SEC..5
99 9 hr min..599 9 hr min..599 9 hr min..599 9 hr min..5
99 9 hr min..599 9 hr min..5
999 9 min.999 9 min.999 9 min.999 9 min.
999 9 min.999 9 min.
999 9 hr.999 9 hr.999 9 hr.999 9 hr.
999 9 hr.999 9 hr.
9999 hr 9999 hr
9999 hr
999 9 SEC.999 9 SEC.999 9 SEC.999 9 SEC.
999 9 SEC.999 9 SEC.
9999 SEC 9999 SEC
9999 SEC
9999 MIN 9999 MIN
9999 min
select by key select by key
select by key
U N T 1U N T 1
p u L s
U N T 2
M I NM I N
T r G
M I N
M I NM I N
M I N M I N
M I N
M I N
R R
E n B L
R R
R
R
S E CS E C
P O O N
S E C S E C
S E C
S E C
Time-1 select:
Time-2 select: Sec, Min, Hr
Sec, Min, Hour
T I M E
U P D n
Memory Retain (yes / no)
Memory Retain (yes / no)
T I M E
M E M O
M E M O
U P
Y E S
Y E S
D n
N O
N O
1 2 3 4
1 2 3 4
Process Value
Set Value
T I M 1
1 2 3 4
Delay time (time-1)
T I M 1
1 2 3 4
Cycle ON time (time-1)
Cycle OFF time (time-2)
SELECTED BY
KEY
SELECTED BY
SELECTED BY
KEY
KEY
SELECTED BY
KEY
SELECTED BY
SELECTED BY
SELECTED BY
KEY
KEY
KEY
SELECTED BY
KEY
SELECTED BY
KEY
press key to
set cycle ON time
press key to
set cycle OFF time
press key to
set cycle Delay time
T I M 2
1 2 3 4
press SET/ENT key
press SET/ENT key
press SET/ENT key
press SET/ENT key
press SET/ENT key
press SET/ENT key
press SET/ENT key
press SET/ENT key
press SET/ENT key
If Delayed ON/ Delayed OFF is selected
If Delayed ON/ Delayed OFF is selected
If Cycling Mode is selected
If Cycling Mode is selected
press
SET/ENT
key
press
SET/ENT
key
Time Count : UP/Down
Time Count : UP/Down
OFF Starting ON Starting
No. of Repeat
Cycle
CONNECTION TERMINAL DIAGRAM
Page - 3 www.multispanindia.com
DESCRIPTION
Time - 1
Delayed OFF
No. of cycle to repeat
All Parameter allowed to set
Lock Parameter
Unit - 2 for Time - 2
Cycling time
Start from relay on
Minute set for Time - 1 or 2
Up counting
Memory Retain : Yes / No
Enable/ Trigger/ Power ON
DISPLAY
SR.
1
9
5
13
3
11
7
15
18
Time - 2
Unit - 1 for Time - 1
Delayed function
Seconds set for Time - 1 or 2
Direction of time counting
All Parameter Locked
Delayed ON
Start from relay off
Hour set for Time - 1 or 2
Down counting
2
10
6
14
17
4
12
8
16
19
20
21
22
T I M 1
T I M 2
Y E S
N O
F U N C
C Y L E
C Y O N
D L O N
C Y O F
D L O F
N O C L
U N T 1
U N T 2
S E C
M I n
R
T I M E
U P
m E M O
P U L S
D N
L O C K
DISPLAY MESSAGE AND THEIR MEANING
1
+VE
L
SUPPLY
110 To 250V AC
N
No1 No2
Nc1 Nc2
C1 C2
I/P1 I/P2 GND RESET
2345678 9 10
17 16 15 14 13 12 11
181920
NPN PROXI:- Short Pins 16 & 15NPN PROXI:- Short Pins 16 & 15
Proxi Connection to 15,14 & 13Proxi Connection to 15,14 & 13
M/S Connection to 16 & 15M/S Connection to 16 & 15
MICRO SWITCH :- Short Pins 14 & 13MICRO SWITCH :- Short Pins 14 & 13
PNP PROXI:- Short Pins 13 & 14PNP PROXI:- Short Pins 13 & 14
Proxi Connection to 16,15 & 14Proxi Connection to 16,15 & 14
M/S
110 TO 250V AC RESET
SUPPLY
18
29
310
411
512
613
714
N
L
RELAY
RELAY
NO NO C
CNC NC
GND
I/P2
I/P1
+Ve
NPN PROXI:- Short Pins 3 & 4
Proxi Connection to 4,5 & 6
M/S Connection to 3 & 4
MICRO SWITCH :- Short Pins 5 & 6
PNP PROXI:- Short Pins 5 & 6
Proxi Connection to 3,4 & 5
NC L
N
R
PROXY
RELAY
SUPPLY
110 TO 270V AC110 TO 270V AC
G
B
M/S
NC
NO
NO
C
RESET
Product improvement and upgrade is a constant procedure. So for more updated operating information and support, please
contact our Helpline : 079-22770865 or Email at marke[email protected]
NOTE :
Page - 4 www.multispanindia.com

This manual suits for next models

2

Other MULTISPAN Timer manuals

MULTISPAN UTR-1244 User manual

MULTISPAN

MULTISPAN UTR-1244 User manual

MULTISPAN UTR-2033 User manual

MULTISPAN

MULTISPAN UTR-2033 User manual

MULTISPAN MDT-4310N User manual

MULTISPAN

MULTISPAN MDT-4310N User manual

MULTISPAN DIN-63C User manual

MULTISPAN

MULTISPAN DIN-63C User manual

MULTISPAN MDT-4310 User manual

MULTISPAN

MULTISPAN MDT-4310 User manual

MULTISPAN DT 10S User manual

MULTISPAN

MULTISPAN DT 10S User manual

MULTISPAN UTR-1044 User manual

MULTISPAN

MULTISPAN UTR-1044 User manual

MULTISPAN UTR-2244 User manual

MULTISPAN

MULTISPAN UTR-2244 User manual

MULTISPAN DIN-63 User manual

MULTISPAN

MULTISPAN DIN-63 User manual

MULTISPAN DI-22U User manual

MULTISPAN

MULTISPAN DI-22U User manual

MULTISPAN UTR-413 User manual

MULTISPAN

MULTISPAN UTR-413 User manual

MULTISPAN UTR 1044 User manual

MULTISPAN

MULTISPAN UTR 1044 User manual

MULTISPAN CYL-22U User manual

MULTISPAN

MULTISPAN CYL-22U User manual

MULTISPAN FRT 22 User manual

MULTISPAN

MULTISPAN FRT 22 User manual

MULTISPAN UTR-4244 User manual

MULTISPAN

MULTISPAN UTR-4244 User manual

MULTISPAN CYL-22 Instruction sheet

MULTISPAN

MULTISPAN CYL-22 Instruction sheet

MULTISPAN UTR-1033 User manual

MULTISPAN

MULTISPAN UTR-1033 User manual

MULTISPAN UTR-433 User manual

MULTISPAN

MULTISPAN UTR-433 User manual

MULTISPAN UTR-2244 User manual

MULTISPAN

MULTISPAN UTR-2244 User manual

MULTISPAN SQT-1044 User manual

MULTISPAN

MULTISPAN SQT-1044 User manual

MULTISPAN SQT 1044 User manual

MULTISPAN

MULTISPAN SQT 1044 User manual

MULTISPAN SDX 22-02 User manual

MULTISPAN

MULTISPAN SDX 22-02 User manual

Popular Timer manuals by other brands

Zamel ASM-04 user manual

Zamel

Zamel ASM-04 user manual

Siemens Profi 7LF4 522-0 operating instructions

Siemens

Siemens Profi 7LF4 522-0 operating instructions

ACU-RITE 00654 instruction manual

ACU-RITE

ACU-RITE 00654 instruction manual

REV EMT450 Assembly and operating instructions

REV

REV EMT450 Assembly and operating instructions

HANYOUNG NUX MA4N-A instruction manual

HANYOUNG NUX

HANYOUNG NUX MA4N-A instruction manual

HANYOUNG NUX TF4 instruction manual

HANYOUNG NUX

HANYOUNG NUX TF4 instruction manual

Smartswitch HNS220TD owner's manual

Smartswitch

Smartswitch HNS220TD owner's manual

HANYOUNG NUX MP Series instruction manual

HANYOUNG NUX

HANYOUNG NUX MP Series instruction manual

Skytech TM/R-AF1-1 Installation and operating instructions

Skytech

Skytech TM/R-AF1-1 Installation and operating instructions

wattstopper RT-50 installation instructions

wattstopper

wattstopper RT-50 installation instructions

Intermatic HB52RC supplementary guide

Intermatic

Intermatic HB52RC supplementary guide

Koch 13007 manual

Koch

Koch 13007 manual

Wieland flare TIME FM6-2 230 V instruction manual

Wieland

Wieland flare TIME FM6-2 230 V instruction manual

VDH ALFA 804-ADS user manual

VDH

VDH ALFA 804-ADS user manual

Intermatic DT620 Series Installation and user instructions

Intermatic

Intermatic DT620 Series Installation and user instructions

Jorc TEC-11 Installation & maintenance instructions

Jorc

Jorc TEC-11 Installation & maintenance instructions

BN Thermic PROTIM-7 instructions

BN Thermic

BN Thermic PROTIM-7 instructions

Robertshaw Paragon 9145 manual

Robertshaw

Robertshaw Paragon 9145 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.