UTR-2244
AUXILIARY SUPPLY:
UNIVERSAL TIMER
Supply voltage
Power consumption
(VA RATING) Approx 4 VA @ 230V AC MAX
ENVIRONMENT CONDITION:
Relative Humidity
Protection Level
(AS Per Request)
Operating Temp. 0°C to 55°C
UP to 95% RH
(non-condensing)
IP-65 (Front side) As per IS/IEC
60529 : 2001
100 to 250V AC, 50-60Hz
MECHANICAL INSTALLATION GUIDELINES
1. Prepare the panel cutout with proper dimensions as shown
above.
2. Fit the unit into the panel with the help of clamp given.
3. The equipment in its installed state must not come in close
proximity to any heating source, caustic vapors, oils steam,
or other unwanted process byproducts.
4. Use the specified size of crimp terminal (M3.5 screws) to
wire the terminal block. Tightening the screws on the
terminal block using the tightening torque of the range of
1.2 N.m.
5. Do not connect anything to unused terminals.
INSTALLATION GUIDELINES
1. This equipment, being built-in-type, normally becomes a
part of main control panel and in such case the terminals
do not remain accessible to the end user after installation
and internal wiring.
2. Do not allow pieces of metal, wire clippings, or fine metallic
fillings from installation to enter the product or else it may
lead to a safety hazard that may in turn endanger life or
cause electrical shock to the operator.
3. Circuit breaker or mains switch must be installed between
power source and supply terminal to facilitate power ‘ON’ or
‘OFF’ function. However this mains switch or circuit breaker
must be installed at convenient place normally accessible to
the operator.
4. Use and store the instrument within the specified ambient
temperature and humidity ranges as mentioned in this
manual.
Page -1
MAINTENANCE
1. The equipment should be cleaned regularly to avoid
blockage of ventilating parts.
2. Clean the equipment with a clean soft cloth. Do not use
isopropyl alcohol or any other cleaning agent.
3. Fusible resistor must not be replaced by operator.
Read complete instructions prior to installation
and operation of the unit.
WARNING : Risk of electric shock.
SAFETY PRECAUTION
!
All safety related codifications, symbols and instructions
that appear in this operating manual or on the equipment
must be strictly followed to ensure the safety of the operating
personnel as well as the instrument.
If all the equipment is not handled in a manner specified
by the manufacturer, it might impair the protection provided
by the equipment.
WARNING GUIDELINES
WARNING : Risk of electric shock.
1. To prevent the risk of electric shock, power supply to the
equipment must be kept OFF while doing the wiring
arrangement. Do not touch the terminals while power is
being supplied.
2. To reduce electro magnetic interference, use wire with
adequate rating and twists of the same of equal size shall
be made with shortest connection.
3. Cable used for connection to power source, must have a
cross section of 1mm or greater. These wires should have
insulations capacity made of at least 1.5kV.
4. A better anti-noise effect can be expected by using
standard power supply cable for the instrument.
Input (Start Pulse)
Time Range
Display
Operating Mode
Size
Keys
Counting Direction
Panel Cutout
Upper: 4 digit, 7 segment, 0.70” Red
Forward - Reverse Timer
Lower: 4 digit, 7 segment, 0.50” Green
72 (H) x 72 (W) x 85 (D) mm
SET/ENT, SHIFT, INC, RESET
68 (H) x 68 (W) mm
TECHNICAL SPECIFICATION
GENERAL SPECIFICATION:
DISPLAY AND KEYS:
DIMENSION:
MECHANICAL INSTALLATION
TERMINAL CONNECTION
1 - Relay 1 control output
2 - Relay 2 control Output
STATUS LED DESCRIPTION
KEY OPERATION
To enter in parameter setting
mode
To reset the timer
PRESS KEYFUNCTION
OPERATOR MODE
PARAMETER SETTING MODE
Edited parameter value to be set,
And move to the next parameter
It will select the digit to modify,
When value is edited
It will change the Value of
selected digit
Page -2
NPN/PNP Proximity
Sec (9.999/999.9/9999)
Micro Switch
Min (99.59/999.9/9999)
Limit Switch
Hour (99.59/999.9/9999)
Cyclic Timer
Sequential Timer
Combination Timer
UP/ DOWN
Reset Option Front Panel Reset
Terminal Reset
UTR 2244
R1
R2
SET
ENT
RESET
TIME
SET TIME
9939
9939
72
85
68
68
3
72
Outline Dimension (mm) Panel Cutout
Dimension (mm)
~
50/60 HZ
4VA
100
250V AC
N0
N0
+12V
I/P1
I/P2
GND
M/S
NC
NC
C
C
L
N
1
2
3
4
5
6
7
8
9
10
11
12
13
14
RESET
RELAY 1
RELAY 2
!
MICRO SWITCH:- M/S Connection 4 & 6
Press Key along
with power on device
RESET
SEQUENTIAL TIMER
OPERATING MODE FUNCTION
Start pulse
Start pulse
COMBINATION TIMER
dL-1
d1c1
dL-2
Of-1
d1c2
Of-2
on-1
r1c1
on-2
5
5
5
5
10
10
10
10
15
15
15
15
20
20
20
20
25
25
25
25
30
30
30
30
35
35
35
35
40
40
40
40
45
45
45
45
50
50
50
50
55
55
55
55
60
60
60
60 65 70
Relay-1
Relay-1 Relay-2
Relay-2
Relay-1 setting
Relay-1 setting
dL-1(Delay time )= 5 sec
d1c1(Delay Time Of Relay 1 & cycle 1)= 5 sec
dL-2(Delay time)= 10 sec
d2c1(Delay Time Of Relay 2 & cycle 1)= 5 sec
of-1(Off time)= 5 sec
d1c2(Delay Time Of Relay 1 & cycle 2)= 5 sec
r1c2(Relay on time Of Relay 2) = 10 sec1 & cycle-
Cyc1(Relay combination) = 2 1 Cyc2(Relay combination) = 2 2
of-2(Off time)= 10 sec
d2c2(Delay Time Of Relay 2 & cycle 2)= 10 sec
r2c2(Relay on time Of Relay 2) = 10 sec2& cycle-
on-1(On time )= 10 sec
r1c1(Relay on time Of Relay 1 )=10 sec& cycle-1
on-2(On time)= 20 sec
r2c1(Relay on time Of Relay )= 10 sec 2& cycle-1
Relay-2 setting
Relay-2 setting
cyc(Total no. of repeat cycle of Relay 1 & Relay 2)= 1
nocl( )=2 Total no. of Relay-1 & Relay-2 Combination
d1c1 d1c2
r1c2 r1c1 r1c2
Time(Sec)
Time(Sec)
r2c1
d2c1 d2c2 r2c2 r2c1
d2c1 r2c2
d2c2
TIME
SET TIME
9939
9939
1
2
FORWORD REVERSE TIMER
Start pulse
cyclic on
cyclic off
CYCLIC TIMER on time (ontm)= 5 sec
off time (oftm)= 10 sec
Reverse time
sttm
sttm
sttm
sttm
sttm
sttm
sttm
sttm
50
5
5
0
0
10
10
10
15
15
15
20
20
20
25
25
25
25
25
20
20
20
20
15
15
15
15
10
10
10
10
5
5
5
5
25
25
30
30
30
30
30
30
30
35
35
35
40
40
40
45
45
45
50
50
50
55
55
55
60
60
60
Relay-1
Relay-1Relay-2Relay-1Relay-2 Relay-2
Forword Time (Frtm) = 10 SeC
Stop Time (Sttm) = 5 Sec
Total Time (totl) = 1 min
Reverse Time (rvtm) = 10 Sec
on time
off time
off time
on time
off time off time
on time
on time
Time(Sec)
Time(Sec)
Time(Sec)
Time(Sec)
Forward time
Time
(sec)
Time
(sec)
Forward time
Reverse time
Time(Sec)
Time(Sec)
ontm
ontm ontm
ontm
oftm
oftm oftm
oftm
This symbol in all graph
will represent Relay is On
-
INPUT SPECIFICATION:
OUTPUT SPECIFICATION:
Relay
Relay Type
Rating
2 nos.
1 C/O (NO-C-NC)
5A, 230V AC
Relay Output
PROXY COLERS CODE
+12V OUTPUT GND
Brown Black Blue
Red Green Black
Start pulse
oftm
STOP
TOTAL TIME
Time
(sec)
SET
ENT
SET
ENT
PARAMETER SETTING PARAMETER SETTING
To Enter in Parameter Setting mode
SET
Press & Hold Key along with power on Device
/
//
Forward
Reverse Timer
Sequential
Timer
Cyclic
Timer
Combination
Timer
Select the operating mode and Restart the device
FRT (Forward Reverse Timer)
fO.OO
frTM
5.0
010
Process Time
Total Time (min)
Forward Time
sttm
05
Stop Time
rutm
010
Reverse Time
tOTL
pass
funt
005.0
25
seC
Total Time
(min.)
( sec./min.)
Press key for 15 Sec to go into Detailed parameter
SET
FRNG
999
RUNT
SEC
RRNG
999
TIME
UP
SEQ (Sequential Timer) CYL (Cyclic Timer) Comb (Combination Timer)
51 150 0 0000
d1C1
r1C1
d1C2
r1C2
d2C1
attm
cyc2
r2C1
CyC1
unt2
d2C2
unt1
rng2
r2C2
rng1
nOCL
ONTM
Oftm
pass
funC
CyCL
unt1
rng1
unt2
rng2
memO
puLs
dL-1
100 300 0 0200
01 00
10 00
01 00
10 00
01 00
01 0
2
10 00
2
seC
01 00
seC
9999
10 00
9999
0004
300 0
300 0
25
CyOn
0025
seC
9999
seC
9999
yes
pwOn
0100
Process Time Process Time Process Time
Delay time of Relay -1 & Cycle-1
Relay on time of Relay -1 & Cycle-1
Relay on time of Relay -1 & Cycle-2
Relay on time of Relay -2 & Cycle-1
Relay on time of Relay -2 & Cycle-2
Delay time of Relay -2 & Cycle-2
Delay time of Relay -1 & Cycle-2
Delay time of Relay -2 & Cycle-1
Depending on cyc1
Depending on cyc2
Auto-Manual time
No. of Relay -1 Combination
Total no. of Relay-1 &
Relay-2 Combination
Set Time Set Time Set Time
(no.of Relay-1 combination)
(no.of Relay-2 combination)
Delay Time of On time of relay 1 &
Off time of relay 1 &
Total no. of Repeat Cycle
Unit selection of Relay 1
Range selection of Relay 1
Off time of relay 2
On time of relay 2
Relay-1
ON-1
1000
On Time of Relay-1
OF-1
0050
Off Time of Relay-1
DL-2
0100
Delay Time of Relay-2
999
999
9999
9999
9999
9999
9999
9999
S E C
S E C
S E C
S E C
Hr
Hr
M I N
M I N
M I N
M I N
9.59
9.59
99.59
99.59
99.59
99.59
9.999
9.999
999.9
999.9
999.9
999.9
999.9
999.9
99.9
99.9
999
999
99.9
99.9
9.99
9.99
Unit selection of Relay 2
Range selection of relay 2
Memory retain
start pulse
(Power on/trigger/enable)
Time Count
Function as
(cyclic on/
(sec./Min./hr.)
(Yes/no)
(sec./min./ hr.)
cyclic off )
ON-2
1000
On Time of Relay-2
OF-2
0050
Off Time of Relay-2
PASS
25
CYCL
0001
Total no. of
Repeat cycle
of Relay-1 & Relay-2
unt1
seC
Unit selection of Relay-1
RNG1
9999
Range Selection of Relay -1
(sec./min./hr.)
9.999 99.59 99.59
999.9 999.9
9999
999.9
9999 9999
M I N H R
S E C
unt2
seC
Unit selection of Relay-2
RNG2
9999
Range Selection of Relay -2
9.999 99.59 99.59
999.9 999.9
9999
999.9
9999 9999
M I N H R
S E C
TIME
TIME
UP
UP
Time count
Up/ down
MEMO
PULS
YES
PWON
Memory Retain
(Yes/no)
Start pulse
( power on / Trigger/ Enable)
Press key for 15 Sec to go into Detailed parameter
SET
Press key for 15 Sec to go into Detailed parameter
SET
Press key for save & exit
Press key for save & exit
Press key for save & exit
Password is 25
Forward time unit
Forward time Range
Reverse time unit
( sec./min.)
Reverse time Range
Time count
Up/down
Password is 25
(sec./min./hr.)
Password is 25
(Up/Down)
Press + key to go into Detailed parameter
SET
Unit selection of Relay 1
(sec./min./ hr.)
Range selection
of Relay-1
9999 9999
9999
S E C Hr
M I N
99.59
99.59
9.999
999.9
999.9
999.9
No. of Relay -2 Combination
Unit selection of Relay 1
(sec./min./ hr.)
Range selection
of Relay-2
9999 9999
9999
S E C Hr
M I N
99.59
99.59
9.999
999.9
999.9
999.9
memO
puls
yes
pwOn
Memory retain
start pulse
(Power on/trigger/enable)
(Yes/no)
Press key for save & exit
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change by
& Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change
by Key
Change by
& Key
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
Press key
SET
ENT
SET
ENT
SET
ENT
SET
ENT
SET
ENT
Press key for save & exit
SET
ENT
Press key for save & exit
SET
ENT
Press key for save & exit
SET
ENT

This manual suits for next models

2

Other MULTISPAN Timer manuals

MULTISPAN UTR-433 User manual

MULTISPAN

MULTISPAN UTR-433 User manual

MULTISPAN MDT-4310 User manual

MULTISPAN

MULTISPAN MDT-4310 User manual

MULTISPAN UTR-1044 User manual

MULTISPAN

MULTISPAN UTR-1044 User manual

MULTISPAN UTR-1033 User manual

MULTISPAN

MULTISPAN UTR-1033 User manual

MULTISPAN FRT 22 User manual

MULTISPAN

MULTISPAN FRT 22 User manual

MULTISPAN UTR - 1044 User manual

MULTISPAN

MULTISPAN UTR - 1044 User manual

MULTISPAN UTR-2244 User manual

MULTISPAN

MULTISPAN UTR-2244 User manual

MULTISPAN UTR-4244 User manual

MULTISPAN

MULTISPAN UTR-4244 User manual

MULTISPAN DI-22U User manual

MULTISPAN

MULTISPAN DI-22U User manual

MULTISPAN DIN-63C User manual

MULTISPAN

MULTISPAN DIN-63C User manual

MULTISPAN UTR-413 User manual

MULTISPAN

MULTISPAN UTR-413 User manual

MULTISPAN MDT-4310N User manual

MULTISPAN

MULTISPAN MDT-4310N User manual

MULTISPAN CYL-22U User manual

MULTISPAN

MULTISPAN CYL-22U User manual

MULTISPAN DT 10S User manual

MULTISPAN

MULTISPAN DT 10S User manual

MULTISPAN UTR-1244 User manual

MULTISPAN

MULTISPAN UTR-1244 User manual

MULTISPAN UTR-2033 User manual

MULTISPAN

MULTISPAN UTR-2033 User manual

MULTISPAN UTR 1044 User manual

MULTISPAN

MULTISPAN UTR 1044 User manual

MULTISPAN CYL-22 Instruction sheet

MULTISPAN

MULTISPAN CYL-22 Instruction sheet

MULTISPAN SQT 1044 User manual

MULTISPAN

MULTISPAN SQT 1044 User manual

MULTISPAN DIN-63 User manual

MULTISPAN

MULTISPAN DIN-63 User manual

MULTISPAN SDX 22-02 User manual

MULTISPAN

MULTISPAN SDX 22-02 User manual

MULTISPAN SQT-1044 User manual

MULTISPAN

MULTISPAN SQT-1044 User manual

Popular Timer manuals by other brands

Radio Shack 61-265 user guide

Radio Shack

Radio Shack 61-265 user guide

Leviton Decora LTT15 installation instructions

Leviton

Leviton Decora LTT15 installation instructions

Theben SYN 161 d manual

Theben

Theben SYN 161 d manual

Favero Coin Timer 1 User and installation manual

Favero

Favero Coin Timer 1 User and installation manual

Theben TR 652 S quick start guide

Theben

Theben TR 652 S quick start guide

REX MicroRex S11 quick start guide

REX

REX MicroRex S11 quick start guide

ETI SHT-1 instructions

ETI

ETI SHT-1 instructions

Prince Castle Merlin II 740-T Series operating instructions

Prince Castle

Prince Castle Merlin II 740-T Series operating instructions

WorkChoice WC2021 instructions

WorkChoice

WorkChoice WC2021 instructions

Velleman WT3116 user manual

Velleman

Velleman WT3116 user manual

Becker Centronic TimeControl TC52 Assembly and operating instructions

Becker

Becker Centronic TimeControl TC52 Assembly and operating instructions

RaceAmerica 5842AW manual

RaceAmerica

RaceAmerica 5842AW manual

Topgreener TGT06-JT installation instructions

Topgreener

Topgreener TGT06-JT installation instructions

KingShield T109-C Installation & operating instructions

KingShield

KingShield T109-C Installation & operating instructions

Aube Technologies TI044 Installation and user guide

Aube Technologies

Aube Technologies TI044 Installation and user guide

Stanley TM-266 quick start guide

Stanley

Stanley TM-266 quick start guide

altadex Drip & Fresh C5191 quick start guide

altadex

altadex Drip & Fresh C5191 quick start guide

Emos P5504 quick start guide

Emos

Emos P5504 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.