E18V
Power on the unit
Nexsan E-18V/E18P with Nexsan E18 expansion unit attached
1Using the two supplied power cords, connect each PSU on the Nexsan E18 to main
power, making sure to fold down the power cord retaining clip over each one.
NOTE: You may need to use the SW0 switch to initiate the power up sequence.
Press and hold the SW0 switch until you hear the systems cooling fans start up
and then release. Do not hold the SW0 switch in for longer than that as that may
cause the product's controllers to start in Emergency Mode.
NOTE: If the audible alarm sounds when the unit is first powered on, this may be
because the controller batteries are discharged. Press either SW0 switch on the
rear of the unit to silence the alarm.
2Wait approximately 10 seconds, then power up Nexsan E-18V/E18P to which the Nexsan E18 is
attached.
3When the main unit is fully powered up (this can take up to 5 minutes), check the EXP IN L0 and L1 LEDs
next to the expansion ports on the Expansion Modules. Both LEDs should be green.
NOTE: If either of the EXP IN LEDs are flashing amber, you must power down both units, correct the
cabling (see Attach cables), and then repeat Step 1 through Step 3.
Nexsan E-18V/E18P with no expansion unit
Using the two supplied power cords, connect each PSU to main power, making sure to fold down the power
cord retaining clip over each one.
NOTE: You may need to use the SW0 switch to initiate the power up sequence. Press and hold the SW0
switch until you hear the systems cooling fans start up and then release. Do not hold the SW0 switch in for
longer than that as that may cause the product's controllers to start in Emergency Mode.
NOTE: If the audible alarm sounds when the unit is first powered on, this may be because the controller
batteries are discharged. Press either SW0 switch on the rear of the unit to silence the alarm.
CAUTION:
When applying power to the unit, use ONLY the IEC power cords originally supplied with the
unit. Do NOT use other power cords, even if they appear identical to the supplied cords.
The Nexsan E-18V/E18P and Nexsan E32XV/E18X/E18XV do not have power switches. Do
NOT attach the power cords until the unit is fully installed, with all disk drives in place.
EXP 0 EXP 1
STATMGMT SERIAL
SW0
NETWORK PORTS
HOST
L1L0
Fibre Channel, 10 GbE, or SAS ports (see below)
Expansion Ports Management Port Serial Port iSCSI Ports
Fibre Channel 10gb Ethernet, Optical 10gb Ethernet, Copper SAS-to-Host
PSU
FAN
L0
L0