
Part number: P0450170 Rev: D Release Date: December 2018
Related Documentation: Nexsan Unity Hardware Maintenance Guide,
Nexsan Unity User Guide, Nexsan Unity Online Help, Nexsan Unity
nxadmin CLI Reference Guide
Technical Support
By Email: support@nexsan.com
By Web: http:// helper.nexsansupport.com/unt_support.html
Nexsan 325 E. Hillcrest Drive, Suite 150, Thousand Oaks, CA 91360 | www.nexsan.com
Copyright © 2010-2018 Nexsan Corporation. All Rights Reserved. Nexsan®, Unity 2200™, Unity 4400™, Unity 6900™, Unity 2200X™, US 224™, US 316™,
US 424™, US 460,™, FASTier™, and the Nexsan logo are trademarks or registered trademarks of Nexsan Corporation. All other trademarks and
registered trademarks are the property of their respective owners.
.
Safety notices
This equipment must be installed and operated in
compliance with local laws and regulations.
Ensure that the ambient temperature at the
installation is between 5°C (41°F) and 30°C
(86°F). If the temperature at the site is not actively
regulated, ensure that daily and seasonal
temperature changes will not result in the ambient
temperature going outside these limits.
Always fully stabilize racks with wall anchors or
stabilizing legs, or both, before mounting the
Nexsan storage unit or any other components on
the rack.
Situate the rack so that full air flow at both the
front and the rear of the Nexsan storage unit is
possible.
Ensure that the floor beneath the mounting rack
has enough load-bearing capacity to support the
rack and all mounted components.
Always fully secure all rack-mounting hardware
when installing the Nexsan storage unit in a rack.
Insufficient rack-mount support may allow the unit
to fall onto other rack-mounted hardware or onto
the floor, potentially damaging equipment or
causing injury to nearby personnel.
Rack and enclosure specifications
Rail kit mounting
3U enclosure height
The rack has square holes
Maximum distances: 30" (800 mm)
Enclosure dimensions
Height:5.25’’133 mm
Width: 17.25’’438 mm
Depth:26.25’’667 mm
Weight
54 lbs24.5 kg (no drives installed)
75 lbs34 kg (all drives installed)
Power requirements
Power supply: 1,200W
Input voltage: 100-240V
Amperage: 12V (100A @ 240V), +5Vsb (6A @
240V, 4A @ 100V)
Input frequency: 50/60 Hz
Power consumption: varies depending on the
number and size of drives, running fans, and room
temperature
NIC1
Indicates network activity on the LAN1
port when flashing.
NIC2
Indicates network activity on the LAN2
port when flashing.
Power fail
Indicates a power supply module has
failed. The second power supply
module takes the load and keeps the
system running, but the failed module
should be replaced as soon as
possible.
This LED should be off when the
system is operating normally.
Fan fail
When flashing, this LED indicates a
fan failure.
When lit continuously, this LED
indicates an overheat condition, which
may be caused by cables obstructing
the airflow in the system or the room
temperature being too high.
Check the routing of the cables and
make sure all fans are connected and
operating normally. You should also
check to make sure that the chassis
covers are installed.
Drive
LED Indication
Green A steady green LED indicates the drive is
powered on.
If this LED is not lit, the drive is not
getting power.
If this LED is flashing, the drive is being
accessed (read or write).
Red A steady red LED indicates a drive
failure.
LED Indication