Step 7: View Configuration Results
When the Site Setup Wizard successfully applies the
configuration settings to the UNITY2000, it prompts
you to create a storage pool.
For steps to create a storage pool, see the Nexsan
UNITY Setup Guide included in your shipment or the
Nexsan UNITY Software User Guide on the
documentation CD.
NOTE: Asynchronous replication. If you promoted a
storage pool on another site and the primary site
gets back online, E-Centre allows you to delete or
promote the storage pool replica as an alternative to
demoting one of the primary storage pools.
What’s Next:
To configure the User Authentication mode:
AOpen the site’s properties panel in E-Centre.
BSelect the User Authentication tab.
CSelect the desired mode of authentication and
click Apply.
The following modes for authentication are available:
Join a Microsoft Active Directory Domain
Connect to an LDAP Directory Service
Use E-Centre authentication (default)
To set site Administrators:
AOpen the site’s properties panel in E-Centre.
BSelect the Administrators tab.
CClick Add Administrators.
DFollow the popup window instructions, then click
Apply.
Safety Notices
This equipment must be installed and operated in
compliance with local laws and regulations.
Ensure that the ambient temperature at the
installation is between 5°C (41°F) and 30°C
(86°F). If the temperature at the site is not actively
regulated, ensure that daily and seasonal
temperature changes will not result in the ambient
temperature going outside these limits.
Always fully stabilize racks with wall anchors or
stabilizing legs, or both, before mounting the
Nexsan storage unit or any other components on
the rack.
Situate the rack so that full air flow at both the
front and the rear of the Nexsan storage unit is
possible.
Ensure that the floor beneath the mounting rack
has enough load-bearing capacity to support the
rack and all mounted components.
Always fully secure all rack-mounting hadware
when installing the Nexsan storage unit in a rack.
Insufficient rack-mount support may allow the unit
to fall onto other rack-mounted hardware or onto
the floor, potentially damaging equipment or
causing injury to nearby personnel.
Rack and Enclosure Specifications
These specifications apply to both UNITY2000 head
and expansion units.
Rail Kit Mounting
3U enclosure height
The rack must have square roles
Maximum distances: 30" (800 mm)
Enclosure Dimensions
Height: 5.2’’ 132 mm
Width: 17.2’’ 437 mm
Depth: 24.2’’ 615 mm
Weight
56 lbs 25.5 kg (no drives installed)
75 lbs 34 kg (all drives installed)
Power Requirements
Power supply: 1,200W
Input voltage: 100-240V
Amperage: 12V (100A @ 240V), +5Vsb (6A @
240V, 4A @ 100V)
Input frequency: 50/60 Hz
Power consumption: varies depending on the
number and size of drives, running fans, and room
temperature
CAUTION: As there are two primary
storage pools in this situation, you must
demote one of them to avoid replication
conflicts.