NoiseKen 01-00006A User manual

INSTRUCTIONMANUAL
RADIATION PROBE
NOISE LABORATORY CO., LTD.
Edition 1.05
AEB00310-00E -0 F
MODEL 01-00006A
01-00007A
01-00008A
01-00009A
01-00010A
01-00030A
01-00031A
01-00033A
01-00043A
01-00050A

NOTICE
The contents of this booklet are subject to change without prior notice.
No part of this booklet may be reproduced or transferred, in any form, for
any purpose, without the permission of Noise Laboratory Co., Ltd.
The contents of this booklet have been thoroughly checked. However, if a
doubtful point, an error in writing or a missing is found, please contact us.
Noise Laboratory Co., Ltd. shall have no liability for any trouble resulting
from the misuse or improper handling of this product regardless of the
contents of this booklet or arising from the repair or remodeling of this
product by a third party other than Noise Laboratory Co., Ltd. or its
authorized person.
Noise Laboratory Co., Ltd. shall have no liability for any trouble resulting
from the remodeling or modification of this product.
In no event shall Noise Laboratory Co., Ltd. be liable for any results
arising from the use of this product.

1
1 APPLICATION FORM FOR INSTRUCTION MANUAL
We place an order for an instruction manual.
Model: 01-000
Applicant:
Company name:
Address:
Department:
Person in charge:
Tel No.:
Fax No.:
Cut off this page "application form for instruction manual" from this volume and keep it
for future use with care.
When an INSTRUCTION MANUAL is required, fill in the above Application
Form and mail or fax it to your nearest sales agent of Noise Laboratory or
Noise Laboratory.
Your sales agent:
NOISE LABORATORY CO., LTD.
1-4-4 CHIYODA, CHUO-KU, SAGAMIHARA-CITY, KANAGAWA PREF. 252-0237 JAPAN
TEL +81-42-712-2051 FAX +81-42-712-2050
Cut line
Cut line

2
Memorandum

3
2 CONTENTS
1 APPLICATION FORM FOR INSTRUCTION MANUAL ............................... 1
2 CONTENTS ......................................................................................... 3
3 GENERAL DESCRIPTION ..................................................................... 5
4 APPEARANCE ..................................................................................... 6
5 SPECIFICATIONS ................................................................................ 9
6 OPERATION ................................................................................... 10
7 WARRANTY ...................................................................................... 12
8 MAINTENANCE ................................................................................. 14
9 NOISE LABORATORY SUPPORT NETWORK ....................................... 15

4
Memorandum

5
3 GENERALDESCRIPTION
Connected to the INS Impulse Noise Simulator, Radiation Probe gives
radiated interference to the circuit, PC board or unit to be tested, allowing
the user to know where are the parts or blocks which are sensitive to
radiated noise.
※
※※
※
For the safety precautions, warranty terms and so on, refer to the
For the safety precautions, warranty terms and so on, refer to the For the safety precautions, warranty terms and so on, refer to the
For the safety precautions, warranty terms and so on, refer to the
relevant section of the manual of y
relevant section of the manual of yrelevant section of the manual of y
relevant section of the manual of your simulator.
our simulator.our simulator.
our simulator.

6
4 APPEARANCE
MODEL:
::
:01-00006A
Loop diameter:
::
:φ
φφ
φ50mm
MODEL:
::
:01-00007A
Loop diameter:
::
:φ
φφ
φ75mm
MODEL:
::
:01-00008A
Loop diameter:
::
:φ
φφ
φ100mm
MODEL:
::
:01-00009A
Loop diameter:
::
:φ
φφ
φ150mm

7
MODEL:
::
:01-00010A
Loop diameter:
::
:φ
φφ
φ200mm
MODEL:
::
:01-00030A
Loop diameter:
::
:φ
φφ
φ300mm
MODEL:
::
:01-00031A
Loop diameter:
::
:φ
φφ
φ250mm

8
MODEL:
::
:01-00033A
Loop diameter:
::
:L type φ
φφ
φ30mm
MODEL:
::
:01-00043A
Loop diameter:
::
:L type φ
φφ
φ300mm
MODEL:
::
:01-00050A
Loop diameter:
::
: φ
φφ
φ30mm

9
5 SPECIFICATIONS
Table Specifications of this product
Parameters Specifications Note
Input voltage ±4000V MAX
Input pulse width
50ns~1μs
Loop diameter
01-00006A: φ 50 mm
01-00007A: φ 75 mm
01-00008A: φ 100 mm
01-00009A: φ 150 mm
01-00010A: φ 200 mm
01-00030A: φ 300 mm
01-00031A: φ 250 mm
01-00033A:L type φ30mm
01-00043A:L type φ300mm
01-00050A: φ 30 mm
Cable length Approx. 2m
Weight Loop diameter φ50mm:Approx. 175g
Loop diameter φ150mm:Approx. 200g
HV Coaxial
Connector NMHV
Noiseken original
(NOTICE)
Connect the radiation probe with Impulse Noise Simulator (INS series).
This radiation probe is originally designed for INS-4300 series, INS-AX
series, 400L, 4001 (both 2kV and 4kV types) , INS-4020/4040 and INS-AX2
series. A conversion connector (Model:02-00034A) is required when it is
used with INS-400 series (Model: INS-410, 420, 420A, etc.).
Coaxial cable and high-voltage coaxial connector
The high-voltage coaxial cable (incorporated in the simulator) and high-voltage coaxial
connector (external) are consumable supplies. Check the high-voltage coaxial cable and
high-voltage coaxial connector with an insulation-resistance tester every half-year or when
they are used for about 200 hours. When the performance drops below DC1000V/100MΩ,
change them for new ones.

10
6 OPERATION
①As shown in the figure, connect the connector of the radiation probe to the
PULSE OUT or 50ΩTERM OUT connected to the PULSE OUT via TERM IN
terminal. These different connections generate different pulse waveforms and
amplitudes.
②Turn on the simulator power.
③Select the desired output voltage, polarity, pulse width and repetition
frequency by setting the controls of the simulator.
④Move the probe loop to locate the point where the radiation from the probe
can invite the degradation in the operational performance of the specimen.
⑤Change the setting of the output voltage, polarity, pulse width and
repetition and repeat the procedures of sections ④.
The obtained data will help you to develop and incorporate effective
protective measures to ensure adequate immunity from radiated interference.
EUT L1
EUT L2
EUT PE
SG
EUT L2
EUT L1
EUT PE
LINE IN
LINE OUT
GROUND PLANE
EUT
FG
50
Ω
TERM IN
L1
L2
L3
C1
C2
C3
C4
C5
C6
INS-4020/4040
PLS OUT
50
Ω
TERM OUT
RADIATION
PROBE
L1
L2
PE
0.1
0.10.1
0.1m
mm
m
1MΩ
0.5m
0.5m0.5m
0.5m±
±±
±0.05m
0.05m0.05m
0.05m
SHORT PLUG
Test set-up y using INS-4020/4040
EUT L1
EUT L2
SG
EUT L2
EUT L1
LINE IN
LINE OUT
GROUND PLANE
FG
EUT
FG
50
Ω
TERM
L1
L2
C1
C2
C2
C3
INS
-
AX2
PULSE OUT
RADIATION
PROBE
Test set-up y using INS-AX2 Series
(Note) FG is an abbreviation for "frame ground".
SG is an abbreviation for "signal ground" for high voltage pulses.
(Note) FG is an abbreviation for "frame ground".
SG is an abbreviation for "signal ground" for high voltage pulses.

11
NOTE
In case of positive pulse on Impulse Noise Simulator, The loop current direction
is indicated by arrow in the following figure.
When a negative pulse is applied, the loop current flows opposite.
Caution label

12
7 WARRANTY
Servicing terms
The following terms are applicable to servicing by Noise Laboratory Co.,
Ltd., (hereafter referred to as the Company) provided to maintain the
intended performance of its products.
1. Scope
The following terms shall apply only to products made by the
Company.
2. Technical servicing fee
In the event of a failure of a product within the warranty period (see
warranty section), the Company will repair a product without charge.
After the warranty expires, repairs will be billed at a nominal cost.
3. Ownership of defective parts
Any defective part exchanged under the Company’s servicing belongs
to it.
4. Limited liability
In the event that damages resulting from servicing by the Company
are intentional or caused by negligence, the Company will pay the
cost but at the purchase value of the relevant product maximum. But,
notwithstanding the foregoing, the Company shall not be responsible
for any incidental or consequential damages of any nature, including
without limitation thereof loss of would-be profit or compensation
demanded from a third party
5. Refusal to offer servicing
The company may not accept a repair order in the following cases:
More than 5 years have passed since the product discontinued
More than 8 years have passed after delivery
Required component for servicing already discontinued and no
alternative is available.
Product changed, repaired or remodeled without obtaining a prior
permission from the Company.
Product severely damaged to the extent it has lost its original form

13
Limited warranty
Noise Laboratory Co., Ltd. (hereafter referred to as the Company)
warrants its products to be free from defects in materials and
workmanship under normal use and service for a period of one year from
date of delivery. In the event of failure of a product covered by this
warranty, the Company will repair the product or may, at its option,
replace it in lieu of repair without charge.
Not withstanding the foregoing, the Company shall not be responsible for
any incidental or consequential damages of any nature, including without
limitation thereof loss of would-be profit or compensation demanded from
a third party. This warranty is valid only in Japan.
1. Scope
This warranty shall only apply to products made by the Company.
2. Period
One year from date of delivery. The warranty may be valid in 6 months
after servicing if the same failure on the same component has
repeated.
3. Exclusions
The followings are exclusions from this warranty:
Consumable parts (including HV relay)
Failure caused by misuse, neglect, accident or abnormal conditions
of operation
Failure caused by remodeling on the user side without prior
permission from the Company
Failure caused by servicing by unauthorized personnel by the
Company
Failure due to force majeure including but not limited to, acts of
God, fire, war, riot, rebellion and others
Failure due to shock or drop in or after transit
Failure due to operation in environment being out of ambient
specifications.
A unit shipped to overseas.

14
8 MAINTENANCE
1. When repair, maintenance or internal adjustment of the unit is required,
a qualified service engineer takes charge of such work.
2. Maintenance on the user side is restricted to the outside cleaning and
functional check of the unit.
3. When checking or replacing the fuse, turn off the switch of the unit and
disconnect the plug socket beforehand.
4. When cleaning the unit, turn off the switch of this unit and the
connected equipment and disconnect the plug socket beforehand.
5. Avoid using chemicals for cleaning. Otherwise, the coating of the unit
may peel off or the sight glass may be broken.
6. Do not open the cover of this unit.

15
9 NOISE LABORATORYSUPPORT NETWORK
If a symptom that seems a trouble is found, check the symptom against
the following check sheet and inform the model name and serial Number
of the product together with the symptom to Noise Laboratory or our
nearest sales agent in your area.
When the product is returned to Noise Laboratory, write the state of the
trouble, contents of your request, model name and serial number in a
repair order, pack the product and repair order sheet in the former
package or equivalent suitable for transit, and send them back.
NOISE LABORATORY CO., LTD.
SALES DEPT. TEL:+81-42-712-2051 FAX +81-42-712-2050
E-mail:sales@noiseken.com
http://www.noiseken.com

NOISE LABORATORY CO., LTD.
1-4-4, CHIYODA, CHUO-KU, SAGAMIHARA CITY, KANAGAWA PREF., 252-0237 JAPAN
TEL: +81-42-712-2051 FAX: +81-42-712-2050
URL: http://www.noiseken.co.jp
PRINT E D I N JA PAN
This manual suits for next models
9
Table of contents
Other NoiseKen Test Equipment manuals

NoiseKen
NoiseKen LSS-F03 Series User manual

NoiseKen
NoiseKen LSS-720B2 User manual

NoiseKen
NoiseKen LSS-6000 Series User manual

NoiseKen
NoiseKen ESS-S3011 User manual

NoiseKen
NoiseKen GT-30R User manual

NoiseKen
NoiseKen INS-AX2 Series User manual

NoiseKen
NoiseKen FNS-AX4-A20-N2447 User manual

NoiseKen
NoiseKen EPS-02Ev3 User manual

NoiseKen
NoiseKen ESS-801 User manual

NoiseKen
NoiseKen 03-00074A User manual