Chapter 2 New for OEM7 – Firmware
OEM6 to OEM7 Integration Guide v1 12
OEM6 OEM7
CONNECTIMU
Added the EPSON G320 IMU.
Removed the Litef LCI-1 IMU.
For the IMU Type parameter, the ASCII values for IMU no longer use the
"IMU_" prefix. However, the legacy ASCIIvalues that contain the "IMU_"
prefix are still supported. The binary IMU type values have not changed.
See the CONNECTIMU command on page24
ETHCONFIG Ethernet interface hardware now automatically connects properly to the
other physical device
EXTERNALPVAS
The format of several of the options in this command have been changed
from Double to Float.
See the EXTERNALPVAS command on page26
FRESET
Added new FRESET targets.
Binary ASCII Description
10 USERDATA Resets the user data saved using the
NVMUSERDATA command
82 USBCONFIG Resets the stored USB port settings
INTERFACEMODE
Added new Interface Mode options:
Binary ASCII Description
49 NOVATELMINBINARY
NovAtel binary message with a minimal
header.
Only available for CCOM ports.
LOG
The default settings for a command can not be checked by logging that
command. A command must be sent to the receiver before logging the
command will produce valid values. Refer to the command description in
this documentation for the default values.
The optional parameters Period, Offset and Hold are only used when the
Trigger is ONTIME. Previous versions of the firmware accepted (but ignored)
non-zero values for Period and Offset even if the Trigger was not ONTIME.
The firmware on OEM7 receivers will reject such commands and return an
error.
It is especially important that these values are zero when entering a LOG
command in Binary or ASCII format.
POSAVE “state” field no longer optional; default ON. A value must now be entered
SETINITAZIMUTH The range for the standard deviation parameter has changed to 1 to 25
degrees.