Novus NHDR-6116A-H2-II User manual

Quick start guide
NHDR-6116A-H2-II

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
2
CAUTIONS AND WARNINGS
THE PRODUCT MEETS THE REQUIREMENTS CONTAINED IN THE FOLLOWING DIRECTIVES:
Exclusion of liability in the event of damage to data contained on disks or other devices or media:
The manufacturer is not liable in the event of damage or loss of data contained on disks or other
devices or carriers during the operation of the Product.
Obligation to consult the Manufacturer before performing any action not provided for in the
instruction manual or other documents:
Before performing an action that is not provided for a given Product in the user manual, other
documents attached to the Product or does not result from the normal purpose of the Product, it is
necessary, under pain of exclusion of the Manufacturer's liability for the consequences of such action,
to contact the Manufacturer.
Pictures in this publication showing camera views can be simulations. Actual camera
images may vary depending on the type, model, settings, observation area, or
environmental conditions.
DIRECTIVE 2014/30/EU OF THE EUROPEAN PARLIMENT AND OF THE
COUNCIL of 26 February 2014 on the harmonization of the laws of the Member States
relating to electromagnetic compatibility (OJ L 96, 29.3.2014, p. 79–106, with changes).
DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 4 July 2012 on waste electrical and electronic equipment WEEE)
(OJ L 197, 24.7.2012, p. 38–71, with changes).
DIRECTIVE 2011/65/EU OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 8 June 2011 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment (OJ L 174, 1.7.2011, p. 88–110, with changes).
COMMISION DELEGATED DIRECTIVE (EU) 2015/863 of 31 March 2015 amending
Annex II to Directive 2011/65/EU of the European Parliament and of the Council as regards
the list of restricted substances.
DIRECTIVE (EU) 2017/2102 OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 15 November 2017 amending Directive 2011/65/EU on the restriction of the
use of certain hazardous substances in electrical and electronic equipment.
DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT
AND OF THE COUNCIL of 26 February 2014 on the harmonisation
of the laws of the Member States relating to the making available on the
market of electrical equipment designed for use within certain voltage limits.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
3
SAFETY REQUIREMENTS
1. Please read this manual carefully before installation and operation;
2. Please keep this manual for the lifespan of the device in case referring to the contents of this
manual is necessary;
3. It is necessary to comply with the safety requirements described in the manual, as they have a
direct impact on the safety of users and the durability and reliability of the device;
4. All activities performed by installers and users must be carried out as described in the manual;
5. The device should be disconnected from power sources during maintenance procedures;
6. It is not allowed to use any additional devices, components or accessories not provided for and not
recommended by the manufacturer;
7. Do not install this device in places where proper ventilation cannot be provided (e.g. closed
cabinets, etc.), as this may cause heat build-up and may result in damage;
8. Do not place the device on unstable surfaces. Installation must be carried out by qualified
personnel with appropriate permissions in accordance with the recommendations provided in this
manual;
9. The device may be powered only from sources with parameters compliant with those indicated by
the manufacturer in the technical data;
Before using the device, read the instruction manual in order to ensure proper and safe operation
of the device. Failure to comply with the instructions may lead to damage to the device and/or
safety violations.
The user may not repair the device himself. Repairs and maintenance of the device may only be
performed by qualified service personnel.
The device, which is an element of a professional CCTV system used for supervision and
control, is not intended for self-assembly in households by persons without specialist
knowledge.
As the product is constantly improved and optimised, some of its parameters and functions may have
changed from those described in this manual. If in doubt, please refer to the user manual at
www.novuscctv.com
The user manual located at www.novuscctv.com is always the most up-to-date version.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
4
FOREWORD INFORMATION
1. FOREWORD INFORMATION
1.1. Main characteristics
• Digital recorders support high definition analog cameras (720p, 1080p, 4MPX, 5MPX) AHD,
TVI, CVI.
• Support IP cameras up to 5 Mpx (hybrid mode).
• AHD recording resolution: 1280 x 1944, 1280 x 1440, 1920 x 1080, 1280 x 720, 960 x 480.
• Dual stream recording.
• Supports 2 x SATA 3,5” HDDs.*
• Channel assigning to each HDD.
• Operating system based on Linux.
• H.264, H.265, H.265+ compression.
• Main monitor 1 x HDMI (max. FullHD), 1 x VGA (max. FullHD).
• Spot monitor - BNC connector (single analog or IP camera sequence).
• Recording compression, resolution, speed and quality defined individually for each camera.
• Channel covering function.
• Intelligent analysis with analog and IP cameras.
• 16 alarm inputs, 4 alarm output.
• 8 channel real-time audio recording.
• PTZ control of analog and IP cameras directly from the device.
• Protocols: Pelco-D, Pelco-P, COAX and others.
• RTSP stream connection as IP channels.
• Backup through USB port and through the IP network.
• Software: N Control 6000 (application for remote administration, live monitoring and recorded
data search).
• Self-diagnostic functions with automatic notification.
• User friendly multi-lingual OSD.
• The device can be operated with a USB computer mouse and remote control.
• Power supply: 12 VDC (100 ~ 240 VAC/12 VDC PSU in-set included).
* The list of recommended disk models and their capacity is available on Novus Security website
in the Compatible Disk file in the product “Downloadable files” tab.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
5
FOREWORD INFORMATION
1.2. Recorders’ technical data
NHDR-6116A-H2-II
Video
Video Input 16 x BNC
Operating mode AHD 5Mpx, TVI 5Mpx, CVI 5Mpx, analog 960H
Monitor Output main (split screen, full screen, sequence): 1 x HDMI (FullHD), 1 x VGA (FullHD),
1 x BNC, spot: 1 x BNC interchangeably to main output
IP Streams Hybrid mode: 16 x AHD + 8 x IP
IP mode: 8 x AHD + 16 x IP
Supported IP resolution max. 2592 x 1944
Audio
Audio Input/Output 8 x RCA (Line-in) / 1 x HDMI, 1 x RCA
Recording
Compression H.264, H.265, H.265+
AHD Recording Speed
480 fps (1280 x 720 - HD)
480 fps (960 x 1080 - 1080p Lite)
240 fps (1920 x 1080 - FullHD)
240 fps (2560 x 1440 - 4Mpx Lite)
160 fps (2650 x 1944 - 5Mpx Lite)
IP Recording Speed Hybrid mode: 240fps
IP mode: 480fps
IP stream size hybrid mode: 32 Mb/s in total from all IP cameras
IP mode: 64 Mb/s in total from all IP cameras
Recording Mode continuous, triggered by: REC/PANIC button, alarm input, motion detection, image
analysis
Schedule individual settings for: each camera, each day of the week, configuration with an
accuracy of: 1 min, possibility of combining individual recording modes
Prealarm/postalarm up to 5 s/up to 10 min
Playback
Playback Speed 480 fps
Recorded Data Search by date/time, events, image analysis events, motion in a defined area, tags
Backup
Backup Methods USB port (HDD or Flash memory), network
Backup File Format AVI, RPAS (player included)
Storage
Internal storage up to: 2 x HDD 3.5” SATA
Total Internal Capacity 20 TB
External storage 1 x eSATA
Total External Capacity 10 TB
Alarm
Alarm Input/Output 16/4 relay type
Camera Alarm Input/
Output supports camera’s alarm input/output
Motion Detection 18 x 22 grid, individual settings of sensitivity
System Reaction to
Alarm Events buzzer, e-mail, alarm output activation, recording activation, PTZ, Full Screen

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
6
NHDR-6116A-H2-II
Intelligent Image Analysis
Supported functions for
analog cameras Line cross, Zone entrance, Smart Motion Detection
Supported functions for IP
cameras
Object detection, Exception, Scene change, Video blurred, Video color cast, Line cross, Zone
entrance
Network
Network Interface 1 x Ethernet - RJ-45 interface, 10/100/1000 Mbit/s
Network Protocols Support HTTP, TCP/IP, IPv4/v6, HTTPS, FTP, DHCP, DNS, DDNS, NTP, RTSP, UPnP, SNMP,
IEEE 802.1X, PPPoE, SMTP, P2P, POS, HTML5
PC/MAC Software NMS, NOVUS MANAGEMENT SYSTEM AC, Internet Explorer, Firefox, Chrome, Opera, N
Control 6000, Edge/Safari, N Control 6000
Mobile applications SuperLive Plus (iPhone, Android)
Max. Number of
Connections with DVR
up to 10 (live monitoring: 10, playback: 10, configuration: 10) , live monitoring up to 28
mainstreams, 96 substreams, playback up to 16 streams
Bandwidth 96 Mb/s in total to all client workstations
PTZ
PTZ Ports 1 x RS-485
PTZ Protocols Pelco-D, Pelco-P
PTZ Functions pan/tilt/zoom, preset commands, patterns
COAX
COAX Functions menu, zoom, focus, PTZ
Auxiliary Interfaces
USB Ports 1 x USB 3.0, 1 x USB 2.0
Operating system
Operating System Linux
OSD Languages: Polish, English, Russian and others
Control IR remote controller, PC mouse (in-set included), network
System Diagnostic automatic control of: HDDs, camera connection loss
Security password protection, IP filtering, MAC filtering
Installation parameters
Dimensions (mm) 380 (W) x 45 (H) x 268 (D)
RACK Mount 19" 1U
Weight 2 kg (without HDDs)
Power Supply 12 VDC (100 ~ 240 VAC/12 VDC PSU in-set included)
Power Consumption 30 W (with HDDs)
Operating Temperature -10°C ~ 50°C
1.3. Package contents
Unpack the device carefully. After unpacking, please ensure that package contains the following items:
• Digital Video Recorder
• Power supply 100~240 VAC/12 VDC
• USB Mouse
• IR remote controller
• Quick start guide
• Screws for screwing the hard disk
If any of the elements has been damaged during transport, pack all the elements back into the original
packaging and contact your supplier.
FOREWORD INFORMATION

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
7
WARNING!
ONVIF protocol support was verified with IP cameras based on ONVIF ver. 2.2 and compatible
with the "PROFILE S".
Implementation of the ONVIF protocol by different manufacturers may vary by some functions,
which can make them work improperly or not in accordance with expectation. AAT SYSTEMY
BEZPIECZEŃSTWA SP. Z O.O. company is not responsible for incompatibility problems re-
sulting from cameras of other brands than NOVUS, which are using ONVIF protocol. If you
are using ONVIF protocol cameras other than NOVUS brand it is recommended to test each
time whether required functions work correctly.
2. STARTING THE DEVICE
2.1 Electrical connection and other back panel elements.
1. VIDEO IN: BNC Video inputs for connecting video signal from cameras
2. AUDIO IN: Audio mono inputs to connect microphones
3. CVBS: CVBS Video output
4. HDMI: Main monitor connector, use the HDMI cable to connect monitor
5. VGA: VGA monitor connection
6. LAN: RJ-45 connector port to connect to the local network and internet
7. USB: USB port for external Flash memory and other USB devices
8. RS485: RS-485 bus connector for PTZ cameras
9. DC 12V: Recorder power supply connection socket
10. AUDIO OUT: Audio output for connecting a local speaker with an amplifier
11. CONNECTORS: Alarm input / output connector block
12. E-SATA: Sockets for connecting E-SATA devices
2.2 HDD mounting
The NHDR-6116A-H2-II recorders allow mounting two internal disks.
4
2
7
8
6
1
3
11
5
9
10
12
STARTING THE DEVICE

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
8
STARTING THE DEVICE
NOTE!
In order to find information regarding the compatible models of HDDs and their maximum
capacities, please contact Novus distributor or check the information presented at
www.novuscctv.com. AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O. company is not
responsible for any problems from using not recommended hard drives.
The list of compatible HDDs contains all the HDDs that can be used with a given NHDR
including HDDs designed for office use - so called desktop disks. However, due to the fact that
reliability of the recording process and data safety are paramount factors of any CCTV system,
we strongly advise to use HDDs designed for continuous (24/7) operation.
You need to format disks if they were used in a different device. All data saved on HDD prior to
format will be lost.
In the recorder, unscrew the three screws at the back of the recorder housing.
After removing the housing, mount the disk using assembly screws (4 pcs.) for each mounted disk.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
9
STARTING THE DEVICE
After screwing the disks, connect the power and signal cables to the disks.
After connecting the hard disk drive, mount the cover, start the NHDR to check the correct connections
and format the hard disk.
NOTE:
If the disk has been used in another device, it must be formatted. The formatting process results
in the loss of data saved on the disk.
2.3. Connecting the power supply.
To start please connect provided power cord in the rear power port of the NHDR. Initialization lasts
approximately 60 seconds. During this time executing any device functions and pressing any buttons is
prohibited. To shut down the device please use the menu.
NOTE:
Make connection when the power is not applied.
Do not place the power cord under the carpet or rug. The power cord is usually earth-grounded.
However, even if it's not earth-grounded, never modify it on your own for earth-grounding.
Make sure that power adapter is placed near of NHDR and secured from accidental
disconnection.
If the device was brought from a location with lower temperature, please wait until it reaches the
temperature of location it is currently in. Turning the device on immediately after bringing it
from a location with lower ambient temperature is forbidden, as the condensing water vapour
may cause short-circuits and damage the device as a result.
Before starting the device familiarize yourself with the description and the role of particular
inputs, outputs and adjusting elements that the device is equipped with.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
10
STARTING THE DEVICE
2.4. Connecting monitor
The recorders have HDMI, VGA and BNC connectors.
Following resolutions are supported for HDMI and VGA outputs: 1280x1024, 1920x1080.
NOTE :
Emergency switching of the screen resolution is possible after pressing the right mouse button
after more than 5 seconds until you hear a sound signal from the recorder.
2.5. Connecting camera and Network
AHD cameras should be connected by coaxial cable to BNC connectors of the recorder.
The maximum cable length between the recorder and camera depends on the quality of the cable and
the mode used.
The recorder requires the use of a switch to connect IP cameras. The permissible cable distance from
the switch to each network device is 100m. Cameras, Internet and other devices should be connected
as shown below. We recommend configuring the cameras before connecting to the recorder as
described in the camera user's manual. Please remember that the cameras should be addressed with a
unique IP address supported by the recorder. Connecting cameras and network devices to the recorder
Before configuring the connection of cameras in the recorder, we recommend using a PC to configure
the cameras in accordance with the camera instructions.
NETWORK
SWITCH
INTERNET PC
NHDR-6116A-H2-II
IP CAMERAS
AHD CAMERAS

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
11
STARTING THE DEVICE
2.6. Connecting external devices
• Connecting audio ports
Audio output signal normally are above 200mV 1kΩ. You can connect to it the audio amplifier with the
external speakers.
• Connecting USB devices
The NHDR-6116A-H2-II recorders have 1 USB 3.0 port on the rear panel and 1 USB 2.0 port on front
panel. The ports allow to connect a USB memory, mouse and other compatible USB devices.
• Connecting alarms ports
Alarm in - connectors to connect alarm inputs.
Alarm outputs - connectors to connect alarm outputs.
GND - ground connector block (used to connect alarm inputs).
Example of connecting alarm output no. 1, follow the
drawing.
Example of sensor connection to alarm input 1.
Alarm inAlarm out
GND
Alarm in1 COM ALARM
Power
source
NO1 COM1 ALARM
Power
source

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
12
2.7. Security recommendations for network architecture and configuration
NOTE!
Below are shown security recommendations for network architecture and configuration
of CCTV systems that are connected to the Internet to reduce the risk
of unauthorized interference with the system by a third party.
1. Absolutely change the default passwords and user names (if the device gives this possibility)
of all applied network devices (recorders, cameras, routers, network switches,
etc.) to the severely complexity password. Use lowercase and uppercase letters, numbers, and special
characters if there is such possibility.
2. Depending on the available functionality in the order to restrict access to the used network devices
at the administrator account level, it is recommended to configure the users accounts accordingly.
3. Do not use DMZ function (Demilitarized zone) in your router. Using that function you open
the access to recorder system from the Internet on all ports, which gives possibility for
an unauthorized interference with the system.
Instead of DMZ use port forwarding redirect only the ports which are necessary for the performance
of the connection (detailed information about ports of communication in different models of recorders,
cameras, etc. can be found in the operating instructions).
4. Use routers with firewall function and make sure it is enabled and properly configured.
5. It is recommended to change the default network communication port numbers of used devices
if there is such possibility.
6. If used network devices has aUPnP feature and it is not used, turn it off.
7. If used network devices has aP2P feature and it is not used, turn it off.
8. If used network devices support HTTPS protocol for connection, it is recommended to use it.
9. If used network devices support IP filtering for authorized connections function, it is recommended
to use it.
10. If used recorder has two network interfaces it is recommended to use both of them to physically
separate network for cameras and network for Internet connection. The only device in the system,
accessible from Internet is recorder - there is no physically access directly to any camera.
STARTING THE DEVICE

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
13
NHDR OPERATING
3. NHDR OPERATING
3.1. Front panel description
1. LED Diodes of recorder operation signaling.
- REC - recording started
- NET - network activity
- PWR - power supplay activity
2. USB USB 2.0 port for connecting a mouse with a USB connector or Flash
memory for copying recordings.
3.2. Controlling via USB mouse
It is possible to control all NHDR functions using mouse with a USB interface. Double clicking on any
camera in split mode (e.g. 2x2, 3x3) switches it to full screen mode. Another double click returns to the
previous display mode.
A single click on a camera shows the channel menu. Moving the cursor down the screen displays the
menu bar. During configuration, the left mouse button select individual items. Some indicated
parameters can be changed by the mouse wheel. The right button allows to leave the menu.
3.3. First launch
To start the unit connect the DC adapter and wait for initialization. It lasts for approximately 60
seconds. During this time executing any device functions and pressing any buttons is prohibited.
After first launch NHDR displays window which allows to choose the language and location.
1
2

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
14
NHDR OPERATING
In the next step, read and accept the Privacy Statement. Check the checkbox at the bottom
of the window and press OK.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
15
NHDR OPERATING
The next wizard window allows to set time parameters such as TIME ZONE, SYSTEM TIME, DATE
FORMAT, TIME FORMAT, DST, SYNCHRONOUS, NTP SERVER and VIDEO FORMAT. After
making your selection, click the NEXT button.
Change the password in the password change wizard. The password must be at least 8 characters long.
It should contain a number, and upper and lower case letters. Enter them on the screen keyboard
available after clicking in the NEW PASSWORD and CONFIRM PASSWORD fields.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
16
NHDR OPERATING
To display the entered password, check the DISPLAY PASSWORD box. Selecting LOG IN
AUTOMATICALLY checkbox will automatically log the user into the system after starting the
recorder.
By selecting the ENABLE field in the PATTERN LOCK row, it is possible to activate the setting
of enabling access for the user by means of a graphic pattern instead of entering the password. To start
the graphic symbol settings, click the EDIT button. Then, holding down the left mouse button, move
the cursor between the displayed circles twice to mark the pattern that will be used to unlock
the device.
After clicking on the NEXT button, a window is displayed that allows you to set a set of questions
and answers that can unlock access to the recorder.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
17
NHDR OPERATING
To add a question, click on the QUESTION field to enter the question using the keyboard. Then click
on the ANSWER field to enter the answer to the question. Clicking on the ADD button adds a set of
questions and answers. Clicking the NEXT button takes you to the window in which information about
the disk connected to the recorder is displayed.
If the STATUS field displays information about the inaccessibility of the disk, format the disk
by clicking on the FORMAT button. A window appears asking to confirm that you want to format
the disk.
NOTE: Formatting causes the loss of information stored on the hard drive.
Pressing the OK button confirms the intention to format the disk.
The status of the disk should be "READ AND WRITE" after successful formatting.

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
18
NHDR OPERATING
3.4. Startup configuration
After the first start of the NHDR, the setup wizard window is displayed (if the function has not been
disabled before). In order to properly configure the recorder, follow these steps with the procedure:
Note:
For suggested values for IP camera setting please refer to the “Cameras Capability Table”
available on the www.novuscctv.com website. If you set wrong values some problems may
appear: the NHDR cannot search the IP camera, the stream cannot be connected, the image is
not fluent, the image quality is bad and so on.
Before starting work with the network recorder, you must perform the initial configuration of the
device. Click on the SETUP WIZARD button to run the wizard

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
19
I. NETWORK SETTINGS:
By default, the recorder has the IP address and DNS settings download from the DHCP server enabled.
If the address retrieval fails, the recorder is available at 192.168.1.100 with the subnet mask of
255.255.255.0. The displayed menu allows to change the settings after uncheck the OBTAIN AN IP
ADDRESS FROM AUTOMATICALLY checkbox and the OBTAIN DNS AUTOMATICALLY field.
The following network recorder settings are available, such as: IP (default 192.168.1.100) Subnet mask
(default setting is 255.255.255.0). If the NHDR needs to be connected to the Internet (for remote
access, sending emails, etc.), the IP addresses for Gateway and for Primary and Secondary DNS. You
can change the default HTTP and HTTPS ports intended for displaying the device's web panel as well
as RTSP ports and server data port.
Parameter changes must be confirmed with the NEXT button
NHDR OPERATING

NHDR-6116A-H2-II Quick start guide version 1.1
All rights reserved © AAT SYSTEMY BEZPIECZEŃSTWA SP. Z O.O.
20
II. ADD CAMERA:
Next window allows to configure the IP camera and add them to the recorder. Upper window displays
cameras found by the NHDR in local network. Before adding cameras to the system, make sure that
they have a unique IP address. Cameras with IP addresses that have already been added to the NHDR
will not be displayed in the search part.
To change the addressable cameras, click on the icon in the column EDIT (This function works
only with NOVUS IP 6000 camera series).
Enter the address in the IP ADDRESS field and set the masks in the SUBNET MASK, then press the
OK button to save the settings.
Press the button to add the camera to the system
In the lower window there is a list of available channels. It is possible to change the name of the
channel after clicking in the EDIT field.
NOTE:
The process of adding NOVUS IP 6000 series cameras with software 5.1.x and higher in which
the activation process has not been carried out cannot be correctly carried out in the start-up
wizard. (v1.4.0 NHDR software). You can check the camera firmware version in the VERSION
column.
NHDR OPERATING
Table of contents
Languages:
Other Novus Measuring Instrument manuals

Novus
Novus NVR-4532-H4/F-II User manual

Novus
Novus NVR-4108-H1 User manual

Novus
Novus N1500G User manual

Novus
Novus NVR-7308P8-H2 User manual

Novus
Novus N1540-485 User manual

Novus
Novus N1540 User manual

Novus
Novus NHDR-4 AHD Series User manual

Novus
Novus NHDR-4104-H1 User manual

Novus
Novus NVR-4204P4-H1/F User manual

Novus
Novus NHDR-4304-H1 User manual

Novus
Novus LogBox BLE User manual

Novus
Novus NVR-6332-H8/FR-II User manual

Novus
Novus NP400 User manual

Novus
Novus NVR-6316A-H1-II User manual

Novus
Novus N CONTROL 4000 User manual

Novus
Novus NHDR-6004-H1-II User manual

Novus
Novus N1040i User manual

Novus
Novus N1500FT User manual

Novus
Novus NVR-6232-H2 User manual

Novus
Novus WL420 User manual