Installation and Maintenance NA-E-100-12 SELV Axial Toilet and Bathroom Fans
4.0 Wiring Instructions
Disconnection from the supply mains must be incorporated within the fixed
wiring in accordance with the wiring regulations and shall have a minimum
contact separation of 3mm in accordance with the latest edition of the IEE
Wiring Regulations.
Only NA-E-100 12V models are suitable for shower cubicles or zones 1 & 2
(in this range).
SL = 230Vac Switched Live L = 230Vac Permanent Live N = Neutral
5.0 Operation
Overrun timer adjustment – models fitted with overrun timers only
Before making any adjustments, isolate the fan from the power supply. Remove
the front cover and the body moulding. Locate the ‘jumper’ on the relevant set
of pins to achieve the desired run-on time (see Fig. 10).
Humidity adjustment – models fitted with humidistat only
All NA-E humidistat fans automatically sense a rapid change in humidity and
adjust accordingly. The humidity control does not require manual adjustment.
Humidistat fans, when energised for the first time, will run and time out as part
of the stabilising process.
6.0 Maintenance
The fan unit does not require any maintenance. However, for optimum
performance, it is advisable to remove any accumulated dust with a low power
vacuum cleaner.
Note: Installation and maintenance of the equipment must be as directed in
the instructions provided with the unit.
7.0 Warranty
The 2 year warranty starts from the day of delivery and includes parts and labour
for the first year. The remaining year covers replacement parts only.
This warranty is void if the equipment is modified without authorisation, is
incorrectly applied, misused, disassembled, or not installed, commissioned and
maintained in accordance with the details contained in this manual and general
good practice.
The product warranty applies to the UK mainland and in accordance with Clause
14 of our Conditions of Sale. Customers purchasing from outside of the UK
should contact Nuaire International Sales office for further details.
8.0 After Sales Enquiries
For technical assistance or further product information, including spare parts and
replacement components, please contact the After Sales Department.
This product is double insulated and does not require an earth conductor.
Maximum room temperature 40°C.
Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right
is reserved to make such changes without prior notice.
PCB Details
Figure 9. DC Power Supply
Unit Serving Bathroom NA-E-100-12
Figure 6. Wiring
Unit Serving Bathroom NA-E-100PC-12 / NA-E-100HPC-12
via pullcord (Auto humidity only)
Figure 7. Wiring with Pullcord
Unit Serving Bathroom NA-E-100T-12 / NA-E-100HPC-12 via
remote switch (Optional timer operation)
Figure 8. Wiring with Remote Switch
12V DC OUT
T
+
-
MAINS POWER IN
LIVE
NEUTRAL
SWITCHED LIVE
121mm
107mm
86mm 72mm
41mm
Range Description
NA-E-100-12 SELV Standard
NA-E-100PC-12 SELV Pull cord override
NA-E-100H-12 SELV Humidistat and optional overrun time
NA-E-100HPC-12 SELV Humidistat and optional overrun time and pull
cord override
NA-E-100T-12 SELV Overrun timer
Figure 10. PCB