2
nuaire.co.uk 029 2085 8400 15. 05. 18. Leaflet Number 671779
Installation and Maintenance NA-E-150 Axial Utility and Kitchen Fans
4.0 Wiring Instructions
Disconnection from the supply mains must be incorporated within the fixed
wiring in accordance with the wiring regulations and shall have a minimum
contact separation of 3mm in accordance with the latest edition of the IEE
Wiring Regulations.
SL = 230Vac 50Hz 1ph Switched Live
L = 230Vac 50Hz 1ph Permanent Live
N = Neutral 5.0 Operation
Overrun timer adjustment – models fitted with overrun timers only
Before making any adjustments, isolate the fan from the power supply. Remove
the front cover and the body moulding. The time control 'pot' can adjust the
desired run-on time between 1 - 20 minutes (see Fig. 9).
6.0 Maintenance
The fan unit does not require any maintenance. However, for optimum
performance, it is advisable to remove any accumulated dust with a low power
vacuum cleaner.
Note: Installation and maintenance of the equipment must be as directed in
the instructions provided with the unit.
7.0 Warranty
The 2 year warranty starts from the day of delivery and includes parts and labour
for the first year. The remaining year covers replacement parts only.
This warranty is void if the equipment is modified without authorisation, is
incorrectly applied, misused, disassembled, or not installed, commissioned and
maintained in accordance with the details contained in this manual and general
good practice.
The product warranty applies to the UK mainland and in accordance with Clause
14 of our Conditions of Sale. Customers purchasing from outside of the UK
should contact Nuaire International Sales office for further details.
8.0 After Sales Enquiries
For technical assistance or further product information, including spare parts and
replacement components, please contact the After Sales Department.
This product is double insulated and does not require an earth conductor.
Maximum room temperature 40°C.
Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right
is reserved to make such changes without prior notice.
Unit Serving Bathroom NA-E-150
Figure 6. Wiring
Range Description
NA-E-150 Standard
NA-E-150T Overrun timer
NA-E-150PC Pull cord override
NA-E-150H Humidistat and optional overrun time
Telephone: 02920 858 400
AfterSales@nuaire.co.uk
Unit Serving Bathroom NA-E-150PC
Figure 7. Wiring
Unit Serving Bathroom NA-E-150T / NA-E-150H via remote
switch (Optional timer operation)
Figure 8. Wiring
PCB Details
Figure 9. NA-E-150 Figure 10. NA-E-150T
IMPORTANT
To aid compliance with Building regulations for kitchen extract, it is
recommended that the unit’s outer front fascia be removed.
However, if the unit is installed adjacent to the hob, and for all other
applications, the front fascia may remain in place.