SLIMAIRE / NA X
12V & 230V, Continuous 2 Speed Slimline Axial Fans
Installation Manual
EMC Directive
2014/30/EU
LVD Directive
2014/35/EU
IPX4
1.0 SAFETY INFORMATION
• The provision of the electrical supply and the connection of the unit to the mains must be
carried out by a qualified electrician.
• Isolate from power supply before removing any covers. During installation / maintenance ensure
all covers are fitted before switching on the mains supply.
• All-pole disconnection from the mains as shown in the wiring diagram must be incorporated
within the fixed wiring and shall have a minimum contact separation of 3mm in accordance with
latest edition of the wiring regulations.
• Ducting must be securely fixed with screws to the spigot to prevent access to live parts. Duct
runs terminating close to the fan must be adequately protected by suitable guards.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
• Precautions must be taken to avoid the back-flow of gases into the room from the open flue of
gas or other fuel-burning appliances.
• This appliance should not be used by children or persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge, unless they have been given supervision
or instruction concerning the safe use of the appliance by a person responsible for their safety.
Children shall not play with the appliance. Cleaning and user maintenance shall not be carried
out by children.
1.1 Hazard Symbols
GENERAL WARNING
Signifies a general warning regarding hazard specified by supplementary information.
ELECTRIC SHOCK
This unit must be completely electrically isolated before any panels are removed. Check
mains supply and control connections.
ROTATING PARTS
This unit contains fast moving rotational parts which may start automatically. It is the
sole responsibility of the installer to adequately guard these components.
REFER TO INSTRUCTION MANUAL
Read and understand the installation and maintenance manual before installing,
operating or maintaining this product.
2
20. 03. 20. Document Number 671421Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA |nuaire.co.uk
SLIMAIRE / NA XPC
Installation Manual
1.2 Important Information
This manual contains important information on the safe and
appropriate assembly, transport, commissioning, operation,
maintenance, disassembly and simple troubleshooting of the product.
While the product has been manufactured according to the accepted
rules of current technology, there is still a danger of personal injury or
damage to equipment if the following general safety instructions and
the warnings contained in these instructions are not complied with.
•Read these instructions completely and thoroughly before
working with the product.
•Keep these instructions in a location where they are accessible
to all users at all times.
•Always include the operating instructions when you pass the
product on to third parties.
1.3 Personal Protective Equipment
The following minimum Personal Protective Equipment (PPE) is
recommended when interacting with Nuaire product:
•Protective Steel Toed Shoes - when handling heavy objects.
•Full Finger Gloves (Marigold PU800 or equivalent) - when
handling sheet metal components.
•Semi Fingerless Gloves (Marigold PU3000 3DO or equivalent)
- when conducting light work on the unit requiring tactile
dexterity.
•Safety Glasses - when conducting any cleaning/cutting operation
or exchanging filters.
•Reusable Half Mask Respirators - when replacing filters which
have been in contact with normal room or environmental air.
Nuaire would always recommend a site specific risk assessment by a
competent person to determine if any additional PPE is required.
2.0 INTRODUCTION
These IPX4-Splashproof fans have been specifically designed to
ventilate small rooms such as toilets, bathrooms, cloakrooms and
kitchens etc. and can be installed on wall, ceiling or panel.
The units extract directly to outside or through a short length of
ducting.
3.0 MECHANICAL INSTALLATION
Installation must be completed by competent persons, in accordance
with good industry practice and should conform to all governing and
statutory bodies i.e. IEE, CIBSE, etc.
This product should not be used in an ambient temperature higher than
40°C (104°F) and should not be exposed to atmospheric agents (rain,
sun, snow, etc.). The product or any part of it should not be placed in
water or other liquids.
Unit Codes Operation Type Weight
(Kg)
NA100XPC /
SLIMAIREX100PC
4” Axial continuous low duty with
boost facility via pull cord / remote
switch operation.
1.5
NA100XPC-12 /
SLIMAIRE100XPC-12
12V version of 4” Axial continuous
low duty with boost facility via pull
cord / remote switch operation.
0.5
NA150XPC /
SLIMAIREX150PC
6” Axial continuous low duty with
boost facility via pull cord / remote
switch operation.
1.5
3.1 Component Key
1. Front Fixing Screw
2. Front Grille
3. Front Cover
4. Motor Fan Assembly
786mm dia.
6
5
4
3
21
1 Unit Components
5. Wall Fixing Screws
6. Wall Plug
7. Cable Clamp Screws
8. Cable Clamp
9. Cable Grommet
3.2 Surface Mounting
Remove the fan from the box, taking care to dispose of the packing
material properly. Check the location of existing wiring for ease of
connection. For optimum performance site the fan a minimum of 2.3m
above ground level.
In the wall or ceiling, cut a hole as follows:
•SLIMAIRE / NA 100X fans - 100mm Ø (taking care to allow any
necessary space for ducting).
•SLIMAIRE / NA 150X fans - 150mm Ø - for through wall
installation.
•SLIMAIRE / NA 150X fans - 156mm Ø - for installation using a wall
liner or telescopic ducting.
For any other wall or ceiling installation check sizes before cutting the
hole. It is the installer's responsibility to use the appropriate core
cutter to obtain the correct hole diameter.
Dismantle the fan:
•Remove the front cover (3) by unscrewing front fixing screw (1).
•Using the motor fan assembly (4) of the fan as a template, mark
the hole drilling positions to fix the fan to the wall or ceiling N.B
use the holes already knocked out in the top right and bottom left
corners of the back of the motor fan assembly.
•Drill the 6mm dia holes.
•Using the wall plugs and long screws provided, fix the motor fan
assembly (4) to the wall/ceiling.
Before fixing the fan to the wall, decide whether to have the cable
entering the fan through the knocked-out hole on the top of the
motor fan assembly (4) or whether through the back of the motor fan
assembly (4). In the first case the included cable clamp will need to be
used. In the second option the cable entry hole will need to be knocked
out.
Connect to electricity supply via a double pole switch of a suitable size,
with contact openings of at least 3mm.
Fix back the front cover (3) of the fan.
For window installation (with optional window kit) see instructions on
page 2.
3
20. 03. 20. Document Number 671421Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA |nuaire.co.uk
SLIMAIRE / NA XPC
Installation Manual
IMPORTANT
Isolation - Before commencing work make sure that the
unit is electrically isolated from the mains and switched live
supply.
L
N
L
N
Double Pole Isolator
230V
~
50Hz
L
N
L
N
T
Triple Pole Isolator
230V
~
50Hz
Fan Unit
N L
12V
N L
230V
N
L
Transformer
Double Pole Isolator
N
L
230V
~
50Hz
L
N
T
Fan unit
L N
12V
N L
230V
N
L
Transformer
Triple Pole Isolator
230V
~
50Hz
2
3
4
5
Wiring - SLIMAIRE/NA 100XPC/150XPC
Wiring - SLIMAIRE/NA 100XPC/150XPC
Wiring - SLIMAIRE/NA 100XPC-12
Wiring - SLIMAIRE/NA 100XPC-12
4.0 ELECTRICAL INSTALLATION
4.1 Electrical Information
Unit Codes m³/hr Pa W dBA @ 3m
NA / SLIMAIRE 100X 95 27 11 40
NA / SLIMAIRE 150X 280 320 26 49
It is recommended that the installation be carried out by a qualified
electrician. All electrical connections must comply with current IEE
wiring regulations. The fan is a fixed appliance, and the electrical supply
must therefore be by a fixed wired and fused (3 amp) spur incorporating
a double or triple pole switch with contact openings of at least 3mm.
Use twin conductor cable of at least 1mm3 in section (Figure 9).
The fan is double insulated and does not require earthing. The fan
complies with current electrical safety regulations (IE64, CENELEC
384), including EEC Directive EMC2004/108/CE concerning the
suppression of radio interference and electromagnetic compatibility,
and LVD2006/95/CE.
The fan must not be used as a switch for water heaters, stoves etc.
The printed circuit board in these fans has been protected to make it
compatible with the majority of fluorescent fittings available on the
market today. However, it is impossible to be aware of all new products
introduced. We suggest, therefore, that you contact your supplier to
establish the compatibility of any fluorescent fittings you intend to use.
4.2 Wiring diagrams
4.2.1 SLIMAIRE/NA 100XPC/150XPC with Integral Cord
4.2.2 SLIMAIRE/NA 100XPC/150XPC
4.2.3 SLIMAIRE/NA 100XPC-12 with Integral Cord
4.2.4 SLIMAIRE/NA 100HT/100PIR/150HT/150PIR with
Humidistat and Integral Sensor Only
4
20. 03. 20. Document Number 671421Nuaire | Western Industrial Estate | Caerphilly | CF83 1NA |nuaire.co.uk
SLIMAIRE / NA XPC
Installation Manual
5.0 MAINTENANCE
It is important that maintenance checks are recorded and that the
schedule is always adhered to, in all cases, the previous report should
be referred to.
5.1 Annually
•Thoroughly inspect the unit and its components for corrosion,
acting immediately to treat/restore any damaged areas.
The front cover can be removed and cleaned with water and a mild
detergent using a soft cloth and the motor fan assembly can be
cleaned with a dry brush or dry cloth. Ensure the unit does not
come into contact with any kind of liquid or solvent.
•All electrical terminals within the unit should be tightened.
6.0 WARRANTY
The 1 year warranty starts from the day of delivery.
This warranty is void if the equipment is modified without
authorisation, is incorrectly applied, misused, disassembled, or not
installed, commissioned and maintained in accordance with the details
contained in this manual and general good practice.
The product warranty applies to the UK mainland and in accordance
with Clause 14 of our Conditions of Sale. Customers purchasing from
outside of the UK should contact Nuaire International Sales office for
further details.
Failure to maintain the unit as recommended will invalidate the
warranty.
7.0 END-OF-LIFE AND RECYCLING
Where possible Nuaire use components which can be largely recycled
when the product reaches its end-of-life:
•Fans, motors, controls, actuators, cabling and other electrical
components can be segregated into WEEE recycling streams.
•Sheet metal parts, aluminium extrusion, heating/cooling coils and
other metallic items can be segregated and fully recycled.
•EPP, plastic ducting, nylon corner pieces, plastic heat exchangers,
packaging material and other plastic components can be
segregated into mixed plastic and widely recycled.
•Cardboard packaging, wood, used filters and other paper
components can be largely recycled or fully processed in energy
from waste centres.
•Remaining Items can be further segregated and processed in
accordance with the zero waste hierarchy. Please call After Sales
Support for further information on items not listed above.
IMPORTANT
Ensure that Nuaire product is made safe from any electrical
/ water / refrigerant supplies before dismantling commences.
This work should only be undertaken by a qualified person in
accordance with local authority regulations and guidelines,
taking into account all site based risks.
8.0 AFTER SALES
For technical assistance or further product information, please contact
the After Sales Department.
Telephone 02920 858 400
aftersales@nuaire.co.uk
Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment
and the right is reserved to make such changes without prior notice.

This manual suits for next models

9

Other NuAire Fan manuals

NuAire NA-E-100 Series Instruction Manual

NuAire

NuAire NA-E-100 Series Instruction Manual

NuAire MRXBOX95AB-WM2 Instruction Manual

NuAire

NuAire MRXBOX95AB-WM2 Instruction Manual

NuAire MRXBOX-ECO3-AE User manual

NuAire

NuAire MRXBOX-ECO3-AE User manual

NuAire AX User manual

NuAire

NuAire AX User manual

NuAire MRXBOXAB-ECO3B-1ZSW User manual

NuAire

NuAire MRXBOXAB-ECO3B-1ZSW User manual

NuAire MRXBOX95B-350 WC Instruction Manual

NuAire

NuAire MRXBOX95B-350 WC Instruction Manual

NuAire FLAT2000 L User manual

NuAire

NuAire FLAT2000 L User manual

NuAire MRXBOX-SIL4 Instruction Manual

NuAire

NuAire MRXBOX-SIL4 Instruction Manual

NuAire QUIETWIN QTR Instruction Manual

NuAire

NuAire QUIETWIN QTR Instruction Manual

NuAire GENIE-MX Instruction Manual

NuAire

NuAire GENIE-MX Instruction Manual

NuAire AXUS SVT Series Instruction Manual

NuAire

NuAire AXUS SVT Series Instruction Manual

NuAire XBOXER Instruction Manual

NuAire

NuAire XBOXER Instruction Manual

NuAire AVT Series Instruction Manual

NuAire

NuAire AVT Series Instruction Manual

NuAire DE Seies User manual

NuAire

NuAire DE Seies User manual

NuAire AX User manual

NuAire

NuAire AX User manual

NuAire MRXBOXAB-ECO2-1ZSW User manual

NuAire

NuAire MRXBOXAB-ECO2-1ZSW User manual

NuAire Ecosmart MRXBOX95B-LP1 Instruction Manual

NuAire

NuAire Ecosmart MRXBOX95B-LP1 Instruction Manual

NuAire xboxer xbc+ User manual

NuAire

NuAire xboxer xbc+ User manual

NuAire iSense User manual

NuAire

NuAire iSense User manual

NuAire MRXBOXAB-ECO4-AESC User manual

NuAire

NuAire MRXBOXAB-ECO4-AESC User manual

NuAire Genie-DC Series Instruction Manual

NuAire

NuAire Genie-DC Series Instruction Manual

NuAire NALT-L Series Instruction Manual

NuAire

NuAire NALT-L Series Instruction Manual

NuAire MRXBOXAB-ECO3-1ZSW User manual

NuAire

NuAire MRXBOXAB-ECO3-1ZSW User manual

NuAire OPUSDC-SA-60 Instruction Manual

NuAire

NuAire OPUSDC-SA-60 Instruction Manual

Popular Fan manuals by other brands

Evolar EVO-CF50BW installation instructions

Evolar

Evolar EVO-CF50BW installation instructions

Fujitsu ARU9RLF Disassembly instructions

Fujitsu

Fujitsu ARU9RLF Disassembly instructions

Vent-Axia Centrif Duo Installation and wiring instructions

Vent-Axia

Vent-Axia Centrif Duo Installation and wiring instructions

AERMEC gll10r installation manual

AERMEC

AERMEC gll10r installation manual

Harbor Breeze CALERA CLRO52-II manual

Harbor Breeze

Harbor Breeze CALERA CLRO52-II manual

Zephir ZFS9107B instruction manual

Zephir

Zephir ZFS9107B instruction manual

Progress Lighting AirPro P2594 installation manual

Progress Lighting

Progress Lighting AirPro P2594 installation manual

flowair ELIS T-W-100 Technical documentation operation manual

flowair

flowair ELIS T-W-100 Technical documentation operation manual

xtemp UXP 8011-HC090 operating instructions

xtemp

xtemp UXP 8011-HC090 operating instructions

Hunter Alexander 51939 installation manual

Hunter

Hunter Alexander 51939 installation manual

Continental Electric CE27616 user manual

Continental Electric

Continental Electric CE27616 user manual

Monte Carlo Fan Company 5CO52 Series owner's manual

Monte Carlo Fan Company

Monte Carlo Fan Company 5CO52 Series owner's manual

Vortice C ATEX Instruction booklet

Vortice

Vortice C ATEX Instruction booklet

Carrier FZ4A installation instructions

Carrier

Carrier FZ4A installation instructions

Exodraft RS009-4-1 owner's manual

Exodraft

Exodraft RS009-4-1 owner's manual

Titon TP577 Fitting instructions

Titon

Titon TP577 Fitting instructions

Johnson Controls ZQ Series installation manual

Johnson Controls

Johnson Controls ZQ Series installation manual

S&P PCD110X manual

S&P

S&P PCD110X manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.