Omicron CIBANO 500 PTM User manual

CIBANO 500 PTM
User Manual

CIBANO 500 PTM User Manual
2OMICRON
Manual Version: ENU 1007 05 09
© OMICRON electronics GmbH 2020. All rights reserved.
This manual is a publication of OMICRON electronics GmbH.
All rights including translation reserved. Reproduction of any kind, for example, photocopying,
microfilming, optical character recognition and/or storage in electronic data processing systems,
requires the explicit consent of OMICRON. Reprinting, wholly or in part, is not permitted.
The product information, specifications, and technical data embodied in this manual represent the
technical status at the time of writing and are subject to change without prior notice.
We have done our best to ensure that the information given in this manual is useful, accurate and entirely
reliable. However, OMICRON does not assume responsibility for any inaccuracies which may be
present.
The user is responsible for every application that makes use of an OMICRON product.
OMICRON translates this manual from the source language English into a number of other languages.
Any translation of this manual is done for local requirements, and in the event of a dispute between the
English and a non-English version, the English version of this manual shall govern.

OMICRON 3
Contents
Contents
About this manual 8
Safety symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1 Safety instructions 9
1.1 Operator qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.2 Safety standards and rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.2.1 Safety standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.2.2 Safety rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.2.3 Safety accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.3 Grounding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.4 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
1.5 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.5.1 Test equipment integrity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
1.5.2 CIBANO 500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.5.3 Obey the work area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
1.5.4 De-energize the switchgear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.5.5 Measurement setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.5.6 Perform tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.6 Orderly measures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.7 Disclaimer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.8 Compliance statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.9 Recycling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2 System requirements 15
3 Introduction 16
3.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2 Connections and operating controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
3.2.1 Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3.2.2 Side panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.2.3 Status lights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.2.4 Emergency Stop button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
3.3 Primary Test Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
4 Functional scheme 22
4.1 Voltage operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
4.2 Current operating mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
5 Installation 28
5.1 Connect CIBANO 500 to the computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.2 Power up CIBANO 500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.3 Install Primary Test Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.4 Start Primary Test Manager and connect to CIBANO 500. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5.4.1 Upgrade the CIBANO 500 embedded software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.4.2 Upgrade the CIBANO 500 firmware. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
5.4.3 Open the device web interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.5 Connect CIBANO 500 to the test object. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
6 Home view 33
6.1 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
6.2 Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
6.3 Send data to Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
6.4 About . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
6.5 Manage connection to the test system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44

CIBANO 500 PTM User Manual
4OMICRON
6.6 Synchronize data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6.6.1 Server settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.6.2 Managing subscriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
6.6.3 Database synchronization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
6.7 Import data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
6.8 Back up and restore data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
6.9 Status bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
7 Create new guided jobs 50
7.1 Guided test workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.2 Job overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
7.2.1 Job data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
7.2.2 Approving jobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.2.3 Assessment summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.2.4 Managing attachments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
7.3 Location view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
7.3.1 Location data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
7.3.2 Setting the geo coordinates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
7.3.3 Managing attachments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
7.4 Asset view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
7.4.1 General asset data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
7.4.2 Managing attachments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
7.4.3 Circuit breaker view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
7.5 Test view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
7.5.1 Select tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
7.5.2 Group tests. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
7.5.3 General test settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
7.5.4 Import tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
7.5.5 Perform tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
7.5.6 Process templates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
7.5.7 Offline hardware configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
8 Create new manual jobs 72
8.1 Add tests to a job . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
8.2 Process tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
9 Open jobs 76
10 Manage objects 77
10.1 Search for objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
10.2 Perform operations on objects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
10.3 Understanding the master locations and assets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
10.4 Duplicate assets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
10.5 Relocate assets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
10.6 Export and import jobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
11 Control tests 85
11.1 Test control commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
11.2 Checking the circuit breaker state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
12 Display measurement results 87
12.1 Cursor and graphical display options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
12.2 Graphical comparison . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
13 Generate test reports 93
13.1 Setting the report data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
13.2 Generating test reports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
13.2.1 Standard test reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
13.2.2 Customized Excel reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94

OMICRON 5
Contents
13.2.3 Designing the Excel report templates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
13.3 Adding reports from file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
14 Circuit Breaker Testing Library 97
14.1 Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
14.2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
14.3 Updating the CBTL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
14.4 Customizing the CBTL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
14.5 Working with the CBTL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
15 Circuit breaker data 101
15.1 Operating mechanism data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
15.2 Bushing data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
15.3 Assessment limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
15.3.1 Absolute assessment limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
15.3.2 Relative assessment limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
15.4 Velocity zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
16 Spare bushing data 116
17 Off-service diagnostic methods 118
17.1 Testing medium-voltage circuit breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
17.1.1 Safety precautions in the substation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
17.1.2 Test set and software startup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
17.1.3 Test group execution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
17.1.4 Contact Resistance test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
17.1.5 Timing test with CIBANO 500 with the EtherCAT®module . . . . . . . . . . . . . . . . . . . . . . 129
17.1.6 Timing test with CIBANO 500 with the Auxiliary module . . . . . . . . . . . . . . . . . . . . . . . . 138
17.1.7 Dynamic Contact Resistance test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
17.1.8 Minimum Pickup test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
17.1.9 Motor Current test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
17.1.10 Insulation Resistance test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
17.1.11 Testing with external power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
17.1.12 Continuous power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
17.2 Testing high-voltage circuit breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
17.2.1 Safety precautions in the substation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
17.2.2 Test set and software startup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
17.2.3 Testing circuit breakers with CIBANO 500 and the CB MC2 modules. . . . . . . . . . . . . . 165
17.2.4 Test group execution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
17.2.5 Contact Resistance test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
17.2.6 Timing test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
17.2.7 Dynamic Contact Resistance test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
17.2.8 Minimum Pickup test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
17.2.9 Motor Current test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
17.2.10 Testing with external power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212
17.2.11 Continuous power supply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
17.3 Testing gas insulated switchgears with both sides grounded . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
17.3.1 Safety precautions in the substation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
17.3.2 Gas insulated switchgears . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
17.3.3 Test set and software startup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
17.3.4 Contact Resistance test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
17.3.5 Timing (CSM) test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
17.3.6 Minimum Pickup test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
17.3.7 Motor Current test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
17.4 Demagnetization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
17.5 Testing circuit breakers with CIBANO 500 and the CB TN3 modules . . . . . . . . . . . . . . . . . . . . . 252
17.5.1 Timing test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
17.5.2 Dynamic Contact Resistance test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259

CIBANO 500 PTM User Manual
6OMICRON
18 In-service diagnostic methods 267
18.1 Timing (VTM) test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
18.2 First Trip test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
19 Transducers 282
19.1 Angular transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
19.1.1 Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
19.1.2 Installation and measurement setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
19.1.3 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
19.2 Linear transducers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
19.2.1 Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
19.2.2 Installation and measurement setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
19.2.3 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
19.3 Transducer for the ABB HMB driving mechanism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
19.3.1 Installation and measurement setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
19.3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
20 Troubleshooting 295
20.1 Connecting to CIBANO 500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
20.2 Firewall configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
20.2.1 Windows firewall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
20.2.2 Third-party firewall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
20.2.3 Manual firewall configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297
20.3 CIBANO 500 does not start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
20.4 Hardware self-test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
20.5 Changing the hardware configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
20.6 Upgrading the CIBANO 500 embedded software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299
21 Technical data 301
21.1 Calibration interval of CIBANO 500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
21.2 CIBANO 500 specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301
21.3 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
21.3.1 Commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
21.3.2 EtherCAT®interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
21.3.3 Auxiliary module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
21.4 SAFETY connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
21.4.1 Using the safety accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
21.4.2 SAFETY 1 and SAFETY 2 connector pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
21.4.3 External START button connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307
21.4.4 Safety connector dongle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
21.5 Power supply specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
21.6 Environmental conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
21.7 Mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
21.8 Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311
22 Accessories 312
22.1 CB MC2 module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
22.1.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
22.1.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
22.2 CB TN3 module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
22.2.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
22.2.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
22.3 IOB1 module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
22.3.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
22.3.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
22.4 EHB1 EtherCAT®hub . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
22.4.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328

OMICRON 7
Contents
22.4.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329
22.5 Current sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
22.5.1 Designated use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
22.5.2 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
23 Software license information 332
23.1 Manage OMICRON licenses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
23.2 Upload a license file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
23.3 Read the open source licensing information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
Support 333

CIBANO 500 PTM User Manual
8OMICRON
About this manual
This User Manual provides information on how to use the CIBANO 500 test system safely, properly and
efficiently. The CIBANO 500 PTM User Manual contains important safety instructions for working with
CIBANO 500 and gets you familiar with operating CIBANO 500. Following the instructions in this User
Manual will help you to prevent danger, repair costs, and avoid possible down time due to incorrect
operation.
The CIBANO 500 PTM User Manual always has to be available on the site where CIBANO 500 is used.
The users of CIBANO 500 must read this manual before operating CIBANO 500 and observe the safety,
installation, and operation instructions therein.
Reading the CIBANO 500 PTM User Manual alone does not release you from the duty to comply with
all national and international safety regulations relevant to working on high-voltage equipment.
Safety symbols used
In this manual, the following symbols indicate safety instructions for avoiding hazards.
DANGER
Death or severe injury will occur if the appropriate safety instructions are not observed.
WARNING
Death or severe injury can occur if the appropriate safety instructions are not observed.
CAUTION
Minor or moderate injury may occur if the appropriate safety instructions are not observed.
NOTICE
Equipment damage or loss of data possible

OMICRON 9
Safety instructions
1 Safety instructions
1.1 Operator qualifications
Working on high-voltage assets can be extremely dangerous. Only authorized personnel who are
qualified, skilled and regularly trained in electrical engineering are allowed to operate CIBANO 500 and
its accessories. Before starting to work, clearly establish the responsibilities.
Personnel receiving training, instructions, directions, or education on CIBANO 500 must be under
constant supervision of an experienced operator while working with the equipment. The supervising
operator must be familiar with the equipment and the regulations on site. The operator is responsible for
the safety requirements during the whole test.
Maintenance and repair of CIBANO 500 and its accessories is only permitted by qualified experts at
OMICRON service centers except for hardware update options delivered with the relevant
Supplementary Sheet.
1.2 Safety standards and rules
1.2.1 Safety standards
Testing with CIBANO 500 must comply with the internal safety instructions and additional safety-relevant
documents.
In addition, observe the following safety standards, if applicable:
• EN 50191 (VDE 0104) "Erection and Operation of Electrical Test Equipment"
• EN 50110-1 (VDE 0105 Part 100) "Operation of Electrical Installations"
• IEEE 510 "IEEE Recommended Practices for Safety in High-Voltage and High-Power Testing"
Moreover, observe all applicable regulations for accident prevention in the country and at the site of
operation.
Before operating CIBANO 500 and its accessories, read the safety instructions in this User Manual
carefully.
Do not turn on CIBANO 500 and do not operate CIBANO 500 without understanding the safety
information in this manual. If you do not understand some safety instructions, contact OMICRON before
proceeding.
Maintenance and repair of CIBANO 500 and its accessories is only permitted by qualified experts at
OMICRON service centers (see "Support" on page 333).
1.2.2 Safety rules
Always observe the five safety rules:
►Disconnect completely.
►Secure against re-connection.
►Verify that the installation is dead.
►Carry out grounding and short-circuiting.
►Provide protection against adjacent live parts.

CIBANO 500 PTM User Manual
10 OMICRON
1.2.3 Safety accessories
OMICRON offers a range of accessories for added safety during the operation of our test systems. For
further information and specifications, refer to the corresponding Supplementary Sheet or contact
OMICRON Support.
1.3 Grounding
Operating the device without PE and ground connection is life-threatening and not permitted.
►Only operate CIBANO 500 with a mains power supply connected to protective earth (PE).
►Make sure that both the PE connection of the power supply and the ground connector of CIBANO 500
have a solid and low-impedance connection to the grounding system on site.
This also applies to all other test devices and accessories in the test setup.
►Make sure that the grounding clamp has a good electrical contact to the grounding system on site
and avoid connecting it to corroded or painted surfaces.
►Make sure that the grounding terminal connections of all grounded devices in use remain intact
during the whole measurement procedure, and are not accidentally disconnected.
►Only use ground and supply cables provided by OMICRON.
1.4 Power supply
Operating CIBANO 500 without PE and ground connection is life-threatening and not permitted.
►Only operate CIBANO 500 with a mains power supply connected to protective earth (PE).
Power supply from grounded grids (TN/TT)
Before a measurement is started, CIBANO 500 automatically verifies the PE connection in grounded
grids (TN/TT).
►If this check fails, check the power cord and power supply.
If the error message persists, there is no intact connection to protective earth (PE).
This is life-threatening. In this case measurements are not permitted and cannot be performed.
Connect the CIBANO 500 grounding terminal to the grounding system on site.

OMICRON 11
Safety instructions
Power supply from isolated grids (IT)
An IT grid is a grid structure where none of the active conductors are galvanically connected to ground.
In an IT grid, only the PE is connected to ground.
In IT grids the check fails – even if there is a PE connection. This can be the case when CIBANO 500 is
powered by a generator. Since every operation mandates a PE connection, you need to manually verify
this.
If CIBANO 500 is supplied by a generator, the equipotential ground or PE of the generator has to be
grounded properly.
►If this is not possible, measurements are not permitted and cannot be performed.
Additional information
Instead of supplying CIBANO 500 from phase-neutral (L1-N, A-N), it may also be supplied from phase-
phase (for example, L1-L2; A-B).
►Make sure that the voltage does not exceed 240V AC.
►Make sure that the power supply is fuse-protected (16 A automatic circuit breaker).
►Do not use an extension cable on a cable reel to prevent an overheating of the cord; run out the
extension cord.
►Keep extension cables as short as possible to prevent power loss.
1.5 Operation
When operating the CIBANO 500 test system and its accessories, observe the following safety
instructions.
1.5.1 Test equipment integrity
►Do not modify, extend, or adapt CIBANO 500 and its accessories.
►Use only the CIBANO 500 original accessories and cables and only use the OMICRON accessories
together with OMICRON devices as described in this manual.
►Operate CIBANO 500 and its accessories only under ambient conditions specified in "Technical data"
in the CIBANO 500 User Manual.
1.5.2 CIBANO 500
►Use only adequately rated power cords.
►Supply CIBANO 500 only from a power outlet with protective earth (PE).
►To run CIBANO 500 at the maximum power level, we recommend mains overcurrent protection with
a 16 A automatic circuit breaker.
►Position the measurement setup so that you can easily disconnect CIBANO 500 from mains.
►Do not use extension cables on a cable reel to prevent overheating of the cord. Instead, run out the
extension cord.
►Do not operate CIBANO 500 without a solid connection to ground of at least 6 mm2cross-section.
Ground CIBANO 500 as close as possible to the operator.

CIBANO 500 PTM User Manual
12 OMICRON
►The voltage/current indicator on the side panel of CIBANO 500 (see 3.2.2 "Side panel" on page 18)
indicates dangerous voltage on one of the CIBANO 500 sockets, either from an internal source or
from an external one, for example, from the station battery.
►After booting CIBANO 500 either the red or the green status light on the front panel should be on. If
after booting both status lights are on or off, CIBANO 500 might be defective. In this case, do not use
CIBANO 500 and contact your regional OMICRON service center.
►Do not operate CIBANO 500 and its accessories in the presence of explosives, dangerous gases or
vapors.
►Use CIBANO 500 and its accessories only in a technically sound condition.
►Make sure the use of CIBANO 500 is in accordance with the regulations on site and the designated
use described in this document.
►Comply with the workflows described in this document. Avoid interruptions or distractions that could
affect safety.
►If CIBANO 500 or its accessories do not seem to function properly, stop using them and contact your
regional OMICRON service center.
1.5.3 Obey the work area
Figure 1-1: Example of the separation of the work and high-voltage test areas
►Always stay in the work area during test.
►Prior operation make sure that the test equipment is not mounted within the motion path of the circuit
breaker. If needed, perform an operation prior mounting of test equipment (for example, motion
sensors).
►For defining the appropriate high-voltage test area, consider any potential falling equipment (for
example, the CB MC2 modules or clamps) as well as wrong connected motion equipment.
►Position the test equipment on dry and solid surface.
0…300 V DC,
0…240 V AC
outputs
Work area
EHB1
CB MC2
IOB1
Test object
High-voltage
test area
Distance:
min. 1.5 m/5 ft
Height:
min. 1 m/3.3 ft
CB TN3
CIBANO 500
CB MC2CB MC2

OMICRON 13
Safety instructions
1.5.4 De-energize the switchgear
►Identify your test object and make sure that you are using the corresponding wiring diagram.
►Disable any charging mechanism (for example, the motor).
►Ensure that the control circuit of the circuit breaker is de-energized (for example, the spring is
discharged).
►Make sure that the circuit breaker cannot be tripped or closed remotely and locally (for example, use
manual controls or distance orders).
►If you have to make connections to the auxiliary circuit (for example, to the trip or close coils):
►Switch off or disconnect the test object from the station supply.
►Apply the five safety rules.
►Use terminal adapters to connect the test leads.
►Only if required for testing, turn the supply back on.
1.5.5 Measurement setup
►Only use test leads and tools which provide full protection against direct contact.
►Make sure that grounding is applied as described in 1.3 "Grounding" on page 10.
►Connect the test leads of communication cables first to the grounded device before unreeling.
►Keep the unreeled cables close to the ground.
►Always insert connectors completely and use the interlock mechanism.
►Press the Emergency Stop button on the CIBANO 500 front panel while connecting the test leads
to the test object.
►Always insert connectors completely and use the interlock mechanism.
►Do not insert objects (for example, screwdrivers) into any input/output socket.
1.5.6 Perform tests
►Stay in the work area during test.
►Make sure that nobody is within the high-voltage test area.
►Warn people prior any operation to make them aware of any possible disturbances.
1.6 Orderly measures
The CIBANO 500 PTM User Manual or alternatively the e-book has always to be available on the site
where CIBANO 500 is operated.
The users of CIBANO 500 must read this manual before operating CIBANO 500 and observe the safety,
installation, and operation instructions therein.
CIBANO 500 and its accessories may only be used in accordance with the user documentation
(including but not limited to User Manuals, Reference Manuals, Getting Started manuals and
manufacturer manuals). The manufacturer and the distributor are not liable for damage resulting from
improper usage.

CIBANO 500 PTM User Manual
14 OMICRON
Opening CIBANO 500 or its accessories without authorization invalidates all warranty claims. Any kind
of maintenance, calibration or repair on the device itself may only be carried out by persons authorized
by OMICRON.
1.7 Disclaimer
If the equipment is used in a manner not described in the user documentation, the protection provided
by the equipment may be impaired.
1.8 Compliance statement
Declaration of conformity (EU)
The equipment adheres to the guidelines of the council of the European Community for meeting the
requirements of the member states regarding the electromagnetic compatibility (EMC) directive, the low
voltage directive (LVD) and the RoHS directive.
FCC compliance (USA)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Declaration of compliance (Canada)
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
1.9 Recycling
This test set (including all accessories) is not intended for household use. At
the end of its service life, do not dispose of the test set with household waste!
For customers in EU countries (incl. European Economic Area)
OMICRON test sets are subject to the EU Waste Electrical and Electronic
Equipment Directive 2012/19/EU (WEEE directive). As part of our legal obligations
under this legislation, OMICRON offers to take back the test set and ensure that it is
disposed of by authorized recycling agents.
For customers outside the European Economic Area
Please contact the authorities in charge for the relevant environmental regulations in
your country and dispose the OMICRON test set only in accordance with your local
legal requirements.

OMICRON 15
System requirements
2 System requirements
Table 2-1: Primary Test Manager system requirements
Characteristic Requirement (*recommended)
Operating system Windows 10 64-bit*
Windows 8.1 64-bit*,
Windows 8 64-bit*,
Windows 7 SP1 64-bit* and 32-bit
CPU Multicore system with 2 GHz or faster*,
single-core system with 2 GHz or faster
RAM min. 4 GB (8GB*)
Hard disk min. 5 GB of available space
Storage device DVD-ROM drive
Graphics adapter Super VGA (1280×768) or higher-resolution video adapter and monitor1
1. We recommend graphics adapter supporting Microsoft DirectX 9.0 or later.
Interface Ethernet NIC2,
USB 2.03
2. For testing with TESTRANO 600, CPC 100 and CIBANO 500. NIC = Network Interface Card.TESTRANO 600, CPC 100 and
CIBANO 500 can be connected with RJ-45 connectors either directly to the computer or to the local network, for example, by
using an Ethernet hub.
3. For testing with FRANEO 800
Installed software4
4. Installed software required for the optional Microsoft Office interface functions
Microsoft Office 2016*, Office 2013, Office 2010, Office 2007

CIBANO 500 PTM User Manual
16 OMICRON
3 Introduction
3.1 Designated use
CIBANO 500, in conjunction with its accessories or as stand-alone unit, is a test system for
commissioning and maintenance of circuit breakers. The following tests can be performed using
CIBANO 500 according to IEC and ANSI standards:
• Main contact resistance measurement (µΩmeter)
• Minimum pick-up voltage measurement of trip and close coils
• Motor current and voltage
• Main and resistive contact timing measurement
• Sending trip and close commands to perform different operations:
– Open (O)
–Close(C)
–Reclose(OC)
– Trip-free (CO)
– Autoreclose (O-CO)
–CO-CO
–O-CO-CO
• Main contact dynamic resistance measurement enabling users to perform the operations listed earlier
in this section
• Along with timing and dynamic resistance measurements, the following measurements can be
included:
– Trip and close coil current and voltage
– Test of under voltage trip function
– Main contact travel
CIBANO 500 operates only when connected to an external computer through an Ethernet connection.
By using the Primary Test Manager software, you can define, parametrize, and execute various, partly
automated tests.
3.2 Connections and operating controls
CIBANO 500 is available with two interface modules:
•EtherCAT
®1 module providing 4×EtherCAT®interfaces
• Auxiliary module providing 1×EtherCAT®, 3×AUX interfaces
The following figures describe the connections and operating controls of CIBANO 500.
1. EtherCAT®is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.

OMICRON 17
Introduction
3.2.1 Front panel
Figure 3-1: Front view of CIBANO 500
WARNING
Death or severe injury caused by high voltage or current possible
►Do not cover the status lights (for example, with a computer) since the status lights indicate
possible hazards.
►Always observe the status lights while working with CIBANO 500.
Emergency Stop button
Press the button to immediately shut
off all current and voltage outputs.
See 3.2.4 "Emergency Stop button"
on page 20
Start/Stop button
Press the button to enable the
CIBANO 500 outputs and start a
measurement.
Press the button once more to stop
the measurement.
Status lights indicating possible hazardous
voltage and/or current levels at the
CIBANO 500 outputs
See Table 3-1: "Status lights" on page 20.

CIBANO 500 PTM User Manual
18 OMICRON
3.2.2 Side panel
Figure 3-2: Side view of CIBANO 500 with the EtherCAT®module
Voltage/current indicator
See Table 3-1: "Status lights"
on page 20.
V IN (CAT III / 300 V)
Analog voltage input/
external supply input
Mains power socket
one-phase,
100 V…240 V AC,
50/60Hz
NETWORK
RJ-45 socket for connecting
CIBANO 500 to the computer
B - OUTPUT / INPUT (CAT III / 300 V)
Configurable output/input (B)
Output: AC or DC voltage or current
Input: analog
Resetable mains
overcurrent
protection
SAFETY
For connecting the safety
connection dongles or the
3-Position Remote Safety Switch
Power switch
LEDs indicating the
EtherCAT®
communication state
EXT. BOOSTER
Do not connect.
No functionality
implemented.
EXTERNAL MODULES
4×EtherCAT®interface
RJ-45 sockets for
connecting external
EtherCAT®slaves to
CIBANO 500
Equipotential
ground terminal
SERIAL
Do not connect.
No functionality
implemented.
A - OUTPUT / INPUT (CAT III / 300 V)
Configurable output/input (A)
Output: AC or DC voltage or current
Input: analog or binary

OMICRON 19
Introduction
Figure 3-3: Side view of CIBANO 500 with the Auxiliary module
Voltage/current indicator
See Table 3-1: "Status lights"
on page 20.
V IN (CAT III / 300 V)
Analog voltage input/
external supply input
Mains power socket
one-phase,
100 V…240 V AC,
50/60Hz
NETWORK
RJ-45 socket for connecting
CIBANO 500 to the computer
B - OUTPUT / INPUT (CAT III / 300 V)
Configurable output/input (B)
Output: AC or DC voltage or current
Input: analog
Resetable mains
overcurrent
protection
SAFETY
For connecting the safety
connection dongles or the
3-Position Remote Safety Switch
Power switch
EXT. BOOSTER
Do not connect.
No functionality
implemented.
EXTERNAL MODULES
1×EtherCAT®interface
RJ-45 socket for
connecting external
EtherCAT®slave to
CIBANO 500
Equipotential
ground terminal
LEDs indicating the
EtherCAT®
communication state
C-INPUT
(CAT III / 300 V)
3×voltage inputs for
auxiliary contacts
A - OUTPUT / INPUT (CAT III / 300 V)
Configurable output/input (A)
Output: AC or DC voltage or current
Input: analog or binary
SERIAL
Do not connect.
No functionality
implemented.

CIBANO 500 PTM User Manual
20 OMICRON
3.2.3 Status lights
CIBANO 500 provides the following status lights to indicate operating condition.
3.2.4 Emergency Stop button
Pressing the Emergency Stop button immediately shuts off all CIBANO 500 outputs and stops the
running measurement. After pressing the Emergency Stop button, Primary Test Manager does not
allow starting a measurement.
To restart the measurement after the reason for the emergency stop has been resolved, release the
Emergency Stop button by carefully turning it, click the Start button in Primary Test Manager, and then
press the Start/Stop button.
For information about the CIBANO 500 accessories, see "Accessories" in the CIBANO 500 PTM User
Manual.
Table 3-1: Status lights
Status
light
Description CIBANO 500 state Operating condition
Green light on the front
panel is on.
CIBANO 500 is up and
running in the stand-by
mode.
No voltage/current output from
CIBANO 500. Obey the
voltage/current indicator on the side
panel for external hazardous voltage
levels.
Blue ring on the
Start/Stop button is on.
A test is prepared and
ready to start.
Blue ring on the
Start/Stop button is
flashing.
A test is starting.
Possibly there are
hazardous voltage
and/or current levels at
the CIBANO 500
outputs.
Dangerous operating
condition
Red light on the front
panel is flashing.
A test is running.
Possibly there are
hazardous voltage
and/or current levels at
the CIBANO 500
outputs.
Dangerous operating
condition
Voltage/current
indicator on the side
panel is flashing.
There are hazardous
voltage levels (> 42 V)
at the CIBANO 500
inputs/outputs
independent of the
measurement state.
Dangerous operating
condition
Other manuals for CIBANO 500 PTM
1
Table of contents
Other Omicron Test Equipment manuals

Omicron
Omicron CPC 100 User manual

Omicron
Omicron CPC 100 User manual

Omicron
Omicron CMC 310 User manual

Omicron
Omicron CP CR500 User manual

Omicron
Omicron CPC 100 User manual

Omicron
Omicron MPD 800 User manual

Omicron
Omicron CP TD1 User manual

Omicron
Omicron CPC 100 User manual

Omicron
Omicron CIBANO 500 PTM User manual

Omicron
Omicron HGT1 User manual