Omron BP742CANN User manual

FRANÇAIS
ENGLISH
INSTRUCTION MANUAL
®
5 series
Blood Pressure Monitor
Model BP742CANN

2
TABLE OF CONTENTS
Before using the monitor
INTRODUCTION..........................................................................................3
IMPORTANT SAFETY INFORMATION........................................................4
Operating Instructions
1. KNOW YOUR DEVICE ............................................................................8
1.1 Display symbols.......................................................................10
1.2 Before Taking a Measurement.................................................12
2. PREPARATION ......................................................................................13
2.1 Battery Installation ...................................................................13
2.2 Setting the Date and Time.......................................................14
3. USING THE DEVICE .............................................................................15
3.1 Applying the Arm Cuff..............................................................15
3.2 How to Sit Correctly.................................................................17
3.3 Taking a Measurement ............................................................18
3.4 Using the Memory Function.....................................................22
Care and Maintenance
4. ERROR MESSAGES AND TROUBLESHOOTING ...............................26
4.1 Error Messages .......................................................................26
4.2 Troubleshooting.......................................................................29
5. MAINTENANCE AND STORAGE ..........................................................30
5.1 Maintenance ............................................................................30
5.2 Storage ....................................................................................31
5.3 Optional Medical Accessories .................................................32
6. SPECIFICATIONS..................................................................................34
7. FCC STATEMENT..................................................................................36
8. LIMITED WARRANTY............................................................................37
9. GUIDANCE AND MANUFACTURER’S DECLARATION .......................39

3
INTRODUCTION
Thank you for purchasing the OMRON®BP742CANN Blood Pressure Monitor.
Your new blood pressure monitor uses the oscillometric method of blood pressure
measurement. This means the monitor detects your blood movement through your
brachial artery and converts the movements into a digital reading. An oscillometric
monitor does not need a stethoscope so the monitor is simple to use.
Intended Use
This device is a digital monitor intended for use in measuring blood pressure and
pulse rate in adult patient population. The device detects the appearance of
irregular heartbeats during measurement and gives a warning signal with the
measurement result.
Please read this instruction manual thoroughly before using the device.
Please keep for future reference. For specific information about your own blood
pressure, CONSULT YOUR PHYSICIAN.

4
IMPORTANT SAFETY INFORMATION
Warning: Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
(General Usage)
DO NOT adjust medication based on measurement results from this blood
pressure monitor. Take medication as prescribed by your physician. Only a
physician is qualified to diagnose and treat High Blood Pressure.
This device is not intended to be a diagnostic device.
Consult your physician before using the device for any of the following
conditions: common arrhythmias such as atrial or ventricular premature beats or
atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, age, pregnancy,
pre-eclampsia, renal diseases.
Note that PATIENT motion, trembling, shivering may affect the measurement
reading.
Do not use the device on the injured arm or the arm under medical treatment.
Do not apply the arm cuff on the arm while being on an intravenous drip or blood
transfusion.
Consult your physician before using the device on the arm with an arterio-venous
(A-V) shunt.
Do not use the device with other medical electrical (ME) equipment
simultaneously.
Do not use the device in the area the HF surgical equipment, MRI, or CT scanner
exists, or in the oxygen rich environment.
The air tube or the AC adapter cable may cause accidental strangulation in
infants.
Contained small parts that may cause a choking hazard if swallowed by infants.
(AC Adapter (optional) Usage)
Do not use the AC adapter if the device or the power cord is damaged. Turn off
the power and unplug the power cord immediately.
Plug the AC adapter into the appropriate voltage outlet. Do not use in a
multi-outlet plug.
Never plug in or unplug the power cord from the electric outlet with wet hands.

5
IMPORTANT SAFETY INFORMATION
Caution: Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury to the user or patient or
damage to the equipment or other property.
(General Usage)
Always consult your physician. Self-diagnosis of measurement results and self-
treatment are dangerous.
Consult your physician before using the device for any of the following
conditions:
•If you have had a mastectomy.
•People with severe blood flow problems or blood disorders as cuff inflation can
cause bruising.
Do not take measurements more than necessary. It may cause bruising due to
blood flow interference.
Remove the arm cuff if it does not start deflating during the measurement.
Do not use this device on infants or persons who cannot express their intentions.
Do not use the device for any purpose other than measuring blood pressure.
Use only the approved arm cuff for this device. Use of other arm cuffs may result
in incorrect measurement results.
Do not use a mobile phone or other devices that emit electromagnetic fields,
near the device. This may result in incorrect operation of the device.
Do not disassemble the monitor or arm cuff. This may cause an inaccurate
reading.
Do not use in a location with moisture, or a location where water may splash on
the device. This may damage the device.
Do not use the device in a moving vehicle (car, airplane).
Read “If your systolic pressure is more than 210 mmHg” of this instruction
manual, if your systolic pressure is known to be more than 210 mmHg. Inflating
to a higher pressure than necessary may result in bruising where the arm cuff is
applied.

6
IMPORTANT SAFETY INFORMATION
(AC Adapter (optional) Usage)
Fully insert the power plug into the outlet.
When disconnecting the power plug from the outlet, do not pull the power cord.
Be sure to pull from the power plug safely.
When handling the power cord, take care not to do the following:
Wipe the dust off from the power plug.
Unplug monitor when not in use.
Disconnect the power plug before cleaning.
Use only an OMRON AC adapter designed for this device. Use of unsupported
adapters may damage and/or may be hazardous to the device.
(Battery Usage)
Do not insert the batteries with their polarities incorrectly aligned.
Use only 4 “AA” alkaline or manganese batteries with this device. Do not use
other types of batteries. Do not use new and used batteries together.
Remove the batteries if the device will not be used for three months or more.
Do not damage. Do not break it.
Do not tamper with it. Do not forcibly bend or pull.
Do not twist. Do not bundle during use.
Do not pinch. Do not place under heavy objects.

7
IMPORTANT SAFETY INFORMATION
General Precautions
• Do not forcibly crease the arm cuff or the air tube excessively.
• Do not press the air tube while taking a measurement.
• To unplug the air plug, pull on the air plug at the connection with the monitor, not
the tube itself.
• Do not drop the monitor or subject device to strong shocks or vibrations.
• Do not inflate the arm cuff when it is not wrapped around your arm.
• Do not use the device outside the specified environment. It may cause an
inaccurate reading.
• Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawful disposal may cause environmental pollution.

8
1. KNOW YOUR DEVICE
Contents:
Monitor, arm cuff, battery set, instruction manual, quick start guide
Monitor:
Arm cuff:
A. Display
B. Up/Down buttons
C. USER ID selection switch
D. Date/Time setting button
E. START/STOP button
F. Memory button
G. Battery compartment
H. Air jack
I. AC adapter jack
(for optional AC adapter)
G
H
I
D
A
F
E
B
C
D
D
J
L
K
J. Arm cuff
(Arm circumference 9” - 17” (22 - 42 cm))
K. Air plug
L. Air tube

9
1. KNOW YOUR DEVICE
Display:
M. USER ID symbol
N. Systolic blood pressure
O. Diastolic blood pressure
P. Low battery symbol
Q. Heartbeat symbol
(Flashes during measurement.)
R. Memory symbol
S. Average value symbol
T. Date/Time display
U. Movement error symbol
V. Irregular heartbeat symbol
W. Blood pressure level indicator
X. Deflation symbol
Y. Pulse display / Memory number
N
O
P
R
M
S
T
Q
U
V
W
X
Y

10
1. KNOW YOUR DEVICE
1.1 Display symbols
Irregular Heartbeat Symbol ( )
When the monitor detects an irregular rhythm
two or more times during the measurement,
the irregular heartbeat symbol will appear on
the display with the measurement values.
An irregular heartbeat rhythm is defined as a
rhythm that is 25% less or 25% more than the
average rhythm detected while the monitor is
measuring the systolic and diastolic blood
pressure.
If the irregular heartbeat symbol displays with your measurement results, we
recommend you consult your physician. Follow the directions of your physician.
Movement Error Symbol ( )
The movement error symbol is displayed if you move your body during the
measurement. Please remove the arm cuff, and wait 2 - 3 minutes.
Take another measurement, remain still during measurement.
Average Value Symbol ( )
The average value symbol is displayed when you press and hold the memory
button for more than 3 seconds. The most recent average value appears on the
display screen.
Irregular Heartbeat
Normal Heartbeat
Pulse
Blood pressure
Blood pressure
Short Long
Pulse

11
1. KNOW YOUR DEVICE
Blood Pressure Level Indicator
2013 ESH/ESC Guidelines for the management of arterial hypertension
Definitions of hypertension by office and home blood pressure levels
These are from statistical values for blood pressure.
Office Home
Systolic Blood Pressure ≥140 mmHg ≥135 mmHg
Diastolic Blood Pressure ≥90 mmHg ≥85 mmHg

12
1. KNOW YOUR DEVICE
1.2 Before Taking a Measurement
To help ensure an accurate reading, follow these directions:
1. Avoid bathing, drinking alcohol or caffeine, smoking, exercising and eating for 30
minutes before taking a measurement. Rest for at least 15 minutes before taking the
measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the
arm cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A
single measurement does not provide an accurate indication of your true blood
pressure. You need to take and record several readings over a period of time. Try to
measure your blood pressure at the same time each day for consistency.

13
2. PREPARATION
2.1 Battery Installation
1. Remove the battery cover.
2. Insert 4 “AA” batteries as indicated
in the battery compartment.
3. Replace the battery cover.
Notes:
• When the low battery symbol ( ) appears on the display, turn the monitor
off, then replace all batteries at the same time. Long life alkaline batteries are
recommended.
• The measurement values continue to be stored in memory even after the
batteries are replaced.
• The supplied batteries may have a shorter life.
• Dispose of the device, components and optional accessories according to
applicable local regulations. Unlawful disposal may cause environmental
pollution.

14
2. PREPARATION
2.2 Setting the Date and Time
Set the monitor to the correct date and time before taking a measurement for the
first time.
1. Press the button.
2. Push or to change the year.
Push button to confirm the year and then the month flashes. Repeat the
same steps to change the month, day, hour, and minute.
3. Press the START/STOP button to turn the monitor off.
Notes:
• If the batteries have been replaced, the date and time setting will need to be
reset.
• If the date and time are not set, “-:--” appears during or after measurement.
Minute
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Change Confirm
Year
Month
Day
Hour
: Forward
: Back

15
3. USING THE DEVICE
3.1 Applying the Arm Cuff
Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm.
Do not place the arm cuff over thick clothes.
1. Insert the air plug into the air jack
securely.
2. Wrap the arm cuff firmly in place
around your left upper arm.
The bottom edge of the arm cuff should
be 1/2 inch (1 to 2 cm) above the elbow.
Air tube is on the inside of your arm and
aligned with your middle finger.
1/2 inch
(1 - 2 cm)

16
3. USING THE DEVICE
3. Secure closed with the
fabric fastener.
Notes:
•When you take a measurement on the right
arm, the air tube will be at the side of your
elbow. Be careful not to rest your arm on the air
tube.
•The blood pressure can differ between the right arm and the left arm, and the
measured blood pressure values can be different. OMRON recommends to
always use the same arm for measurement. If the values between both arms
differ substantially, please check with your physician which arm to use for your
measurements.

17
3. USING THE DEVICE
3.2 How to Sit Correctly
To take a measurement, you need to be
relaxed and comfortably seated, under
comfortable room temperature. Avoid
bathing, drinking alcohol or caffeine,
smoking, exercising or eating 30 minutes
before taking a measurement.
• Sit on a chair with your feet flat on the floor.
• Sit upright with your back straight.
• Sit with your back and arm being supported.
• The arm cuff should be placed on your arm at
the same level as your heart.

18
3. USING THE DEVICE
3.3 Taking a Measurement
Notes:
• To stop the measurement, press the START/STOP button once to deflate the arm
cuff.
• Remain still and quiet while taking a measurement.
The monitor is designed to take measurements and store the measurement values
in the memory for 2 people using USER ID 1 and USER ID 2.
1. Select your User ID (1 or 2).

19
3. USING THE DEVICE
2. Press the START/STOP button.
The arm cuff will start to inflate automatically.
START INFLATE DEFLATE COMPLETE
If your systolic pressure is more than 210 mmHg
After the arm cuff starts to inflate, press and hold the START/STOP
button until the monitor inflates 30 to 40 mmHg higher than your
expected systolic pressure.
Notes:
• The monitor will not inflate above 299 mmHg.
Inflating to a higher pressure than necessary may result in bruising
where the arm cuff is applied.

20
3. USING THE DEVICE
3. Remove the arm cuff.
4. Press the START/STOP button to turn the monitor off.
The monitor automatically stores the measurement result in its memory.
It will automatically turn off after 2 minutes.
Note: Wait 2-3 minutes before taking another measurement. Waiting between
measurements allows the arteries to return to the condition prior to taking
a measurement.
Table of contents
Other Omron Blood Pressure Monitor manuals

Omron
Omron M6 Comfort User manual

Omron
Omron i-Q142 User manual

Omron
Omron JPN616T User manual

Omron
Omron EVOLV BP7000 User manual

Omron
Omron 5 Series User manual

Omron
Omron R2 User manual

Omron
Omron M7 Intelli IT User manual

Omron
Omron M7 Intelli IT User manual

Omron
Omron BP710 User manual

Omron
Omron JPN750 User manual

Omron
Omron HEM-431CAN User manual

Omron
Omron HEM-6052 User manual

Omron
Omron IntelliSense HEM-712C User manual

Omron
Omron R3 Intellisense User manual

Omron
Omron H-CR17 User manual

Omron
Omron IntelliSense IW2 User manual

Omron
Omron HEM-6111 User manual

Omron
Omron M2 Compact User manual

Omron
Omron M3 Comfort User manual

Omron
Omron BP7350 User manual