F3SG-SR/PG
19
Electrical
Input voltage
TEST
Light emission stops when connected to 24 V DC
ON voltage: Vs-3 V to Vs (short circuit current: approx. 5.0 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 6.0 mA) *
Light emission stops when connected to 0 V
ON voltage: 0 to 3 V (short circuit current: approx. 6.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 5.0 mA) *
OPERATING
RANGE SELECT
INPUT
Long: 12 V to Vs (short circuit current: approx. 4.2 mA) * or open
Short: 0 to 3 V (short circuit current: approx. 4.2 mA)
RESET/EDM
PNP ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) *
NPN ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *
MUTE A/B,
RE-RESET, PSDI
PNP ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) *
NPN ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *
*The Vs indicates a supply voltage value in your environment.
Overvoltage category (IEC 60664-1) II
Indicators Refer to page 32
Protective circuit Output short-circuit protection
Insulation resistance 20 M or higher (500 VDC megger)
Dielectric strength 1,000 VAC, 50/60 Hz (1 min)
Functional
Mutual interference prevention Optical synchronization by Scan Code: in up to 2 sets
Wired synchronization: in up to 3 sets
Cascade connection Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Test function Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-related functions
Interlock
External Device Monitoring (EDM)
Pre-Reset
PSDI
Fixed Blanking/Floating Blanking
Reduced Resolution
Muting/Override
Mutual Interference Prevention
PNP/NPN Selection
Response Time Adjustment
Environmental
Ambient
temperature
Operating -30 to 55 °C (non-icing)
Storage -30 to 70 °C
Ambient
humidity
Operating 35% to 85% (non-condensing)
Storage 35% to 95%
Ambient illuminance Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of protection (IEC 60529) IEC 60529: IP65 and IP67, JIS C 0920 Annex 1: IP67G
Vibration resistance (IEC 61496-1) 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock resistance (IEC 61496-1) 100 m/s2, 1000 shocks for all 3 axes
Pollution degree (IEC 60664-1) 3
Connections
Root cable
Type of
connection
To sensors: dedicated connector, To external: M12 connector type (5-pin emitter and 8-pin receiver) or
open-ended type
IP67 and IP67G (JIS C 0920 Annex 1) * rated when mated.
*The F3SG-SR meets the degree of protection when the root cable is correctly connected with the F3SG-
SR. The degree of protection is not satisfied with the part where cable wires are uncovered.
Number of wires Emitter: 5, Receiver: 8
Cable length Refer to page 7
Cable diameter 6 mm
Minimum bending
radius R5 mm
Cascading cable
Type of
connection
To sensors: dedicated connector, To cascading sensors: M12 connector type (5-pin emitter and 8-pin
receiver) or dedicated connector
IP67 and IP67G (JIS C 0920 Annex 1) * rated when mated.
*The F3SG-SR meets the degree of protection when the cascading cable is correctly connected with the
F3SG-SR and the root cable.
Number of wires Emitter: 5, Receiver: 8
Cable length Refer to page 9
Cable diameter 6 mm
Minimum bending
radius R5 mm
Model
F3SG-
SRA
-
14
F3SG-
SRB
-
14
F3SG-
SRA
-
25
F3SG-
SRB
-
25
F3SG-
SRA
-
45
F3SG-
SRB
-
45
F3SG-
SRA
-
85
F3SG-
SRB
-
85