Omron D4N Series User manual

Safety Limit Switch
D4N
Upgraded Safety Limit Switches Based
on the Popular D4D, Providing a Full
Lineup Conforming to International
Standards
■Lineup includes three contact models with 2NC/1NO and 3NC
contact forms in addition to the previous contact forms 1NC/
1NO, and 2NC. Models with MBB contacts are also available.
■M12-connector models are available, saving on labor and
simplifying replacement.
■
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
■Conforms to EN115, EN81-1, and EN81-2 (slow-action models
only).
■Lineup includes both slow-action and snap-action models with
Zb contacts.
■Certified standards: UL, EN (TÜV), and CCC
Model Number Structure
Model Number Legend
1. Conduit size
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (2-conduit)
8: M20 (2-conduit)
9: M12 connector (1-conduit)
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Top Plunger
32: Top Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE:Fork lever lock (right operation)
LE: Fork lever lock (left operation)
Note: Contact your sales representative for details on models
with safety standard certification.
Be sure to read the “Safety Precautions” on page 18
and the “Precautions for All Safety Limit Switches” .
1 2 3
D4N-@@@@
http://www.ia.omron.com/ 1
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Ordering Information
List of Models
Switches with Two Contacts (with Direct Opening Mechanism)
Note:
It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North American countries.
Actuator Conduit size
Built-in switch mechanism
1NC/1NO
(Snap-action)
2NC
(Snap-action)
1NC/1NO
(Slow-action)
2NC
(Slow-action)
Model Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening
Roller lever (resin
lever, resin roller)
1-conduit
Pg13.5 D4N-1120 D4N-1220 D4N-1A20 D4N-1B20
G1/2 D4N-2120 D4N-2220 D4N-2A20 D4N-2B20
1/2-14NPT D4N-3120 D4N-3220 D4N-3A20 D4N-3B20
M20 D4N-4120 D4N-4220 D4N-4A20 D4N-4B20
M12 connector D4N-9120 D4N-9220 D4N-9A20 D4N-9B20
2-conduit
Pg13.5 D4N-5120 D4N-5220 D4N-5A20 D4N-5B20
G1/2 D4N-6120 D4N-6220 D4N-6A20 D4N-6B20
M20 D4N-8120 D4N-8220 D4N-8A20 D4N-8B20
Roller lever (metal
lever, resin roller)
1-conduit
Pg13.5 D4N-1122 D4N-1222 D4N-1A22 D4N-1B22
G1/2 D4N-2122 D4N-2222 D4N-2A22 D4N-2B22
1/2-14NPT D4N-3122 D4N-3222 D4N-3A22 D4N-3B22
M20 D4N-4122 D4N-4222 D4N-4A22 D4N-4B22
M12 connector D4N-9122 D4N-9222 D4N-9A22 D4N-9B22
2-conduit
Pg13.5 D4N-5122 D4N-5222 D4N-5A22 D4N-5B22
G1/2 D4N-6122 D4N-6222 D4N-6A22 D4N-6B22
M20 D4N-8122 D4N-8222 D4N-8A22 D4N-8B22
Roller lever (metal
lever, metal roller)
1-conduit
Pg13.5 D4N-1125 D4N-1225 D4N-1A25 D4N-1B25
G1/2 D4N-2125 D4N-2225 D4N-2A25 D4N-2B25
1/2-14NPT D4N-3125 D4N-3225 D4N-3A25 D4N-3B25
M20 D4N-4125 D4N-4225 D4N-4A25 D4N-4B25
M12 connector D4N-9125 D4N-9225 D4N-9A25 D4N-9B25
Roller lever (metal
lever, bearing roller)
1-conduit
Pg13.5 D4N-1126 D4N-1226 D4N-1A26 D4N-1B26
G1/2 D4N-2126 D4N-2226 D4N-2A26 D4N-2B26
1/2-14NPT D4N-3126 D4N-3226 D4N-3A26 D4N-3B26
M20 D4N-4126 D4N-4226 D4N-4A26 D4N-4B26
M12 connector D4N-9126 D4N-9226 D4N-9A26 D4N-9B26
Plunger
1-conduit
Pg13.5 D4N-1131 D4N-1231 D4N-1A31 D4N-1B31
G1/2 D4N-2131 D4N-2231 D4N-2A31 D4N-2B31
1/2-14NPT D4N-3131 D4N-3231 D4N-3A31 D4N-3B31
M20 D4N-4131 D4N-4231 D4N-4A31 D4N-4B31
M12 connector D4N-9131 D4N-9231 D4N-9A31 D4N-9B31
2-conduit
Pg13.5 D4N-5131 D4N-5231 D4N-5A31 D4N-5B31
G1/2 D4N-6131 D4N-6231 D4N-6A31 D4N-6B31
M20 D4N-8131 D4N-8231 D4N-8A31 D4N-8B31
Roller plunger
1-conduit
Pg13.5 D4N-1132 D4N-1232 D4N-1A32 D4N-1B32
G1/2 D4N-2132 D4N-2232 D4N-2A32 D4N-2B32
1/2-14NPT D4N-3132 D4N-3232 D4N-3A32 D4N-3B32
M20 D4N-4132 D4N-4232 D4N-4A32 D4N-4B32
M12 connector D4N-9132 D4N-9232 D4N-9A32 D4N-9B32
2-conduit
Pg13.5 D4N-5132 D4N-5232 D4N-5A32 D4N-5B32
G1/2 D4N-6132 D4N-6232 D4N-6A32 D4N-6B32
M20 D4N-8132 D4N-8232 D4N-8A32 D4N-8B32
One-way roller arm
lever (horizontal)
1-conduit
Pg13.5 D4N-1162 D4N-1262 D4N-1A62 D4N-1B62
G1/2 D4N-2162 D4N-2262 D4N-2A62 D4N-2B62
1/2-14NPT D4N-3162 D4N-3262 D4N-3A62 D4N-3B62
M20 D4N-4162 D4N-4262 D4N-4A62 D4N-4B62
M12 connector D4N-9162 D4N-9262 D4N-9A62 D4N-9B62
2-conduit
Pg13.5 D4N-5162 D4N-5262 D4N-5A62 D4N-5B62
G1/2 D4N-6162 D4N-6262 D4N-6A62 D4N-6B62
M20 D4N-8162 D4N-8262 D4N-8A62 D4N-8B62
One-way roller arm
lever (vertical)
1-conduit
Pg13.5 D4N-1172 D4N-1272 D4N-1A72 D4N-1B72
G1/2 D4N-2172 D4N-2272 D4N-2A72 D4N-2B72
1/2-14NPT D4N-3172 D4N-3272 D4N-3A72 D4N-3B72
M20 D4N-4172 D4N-4272 D4N-4A72 D4N-4B72
M12 connector D4N-9172 D4N-9272 D4N-9A72 D4N-9B72
2-conduit
Pg13.5 D4N-5172 D4N-5272 D4N-5A72 D4N-5B72
G1/2 D4N-6172 D4N-6272 D4N-6A72 D4N-6B72
M20 D4N-8172 D4N-8272 D4N-8A72 D4N-8B72
Adjustable roller
lever, form lock
(metal lever, resin
roller) 1-conduit
Pg13.5 D4N-112G D4N-122G D4N-1A2G D4N-1B2G
G1/2 D4N-212G D4N-222G D4N-2A2G D4N-2B2G
1/2-14NPT D4N-312G D4N-322G D4N-3A2G D4N-3B2G
M20 D4N-412G D4N-422G D4N-4A2G D4N-4B2G
M12 connector D4N-912G D4N-922G D4N-9A2G D4N-9B2G
2-conduit G1/2 D4N-612G D4N-622G D4N-6A2G D4N-6B2G
M20 D4N-812G D4N-822G D4N-8A2G D4N-8B2G
Adjustable roller
lever, form lock
(metal lever, rubber
roller) 1-conduit
Pg13.5 D4N-112H D4N-122H D4N-1A2H D4N-1B2H
G1/2 D4N-212H D4N-222H D4N-2A2H D4N-2B2H
1/2-14NPT D4N-312H D4N-322H D4N-3A2H D4N-3B2H
M20 D4N-412H D4N-422H D4N-4A2H D4N-4B2H
M12 connector D4N-912H D4N-922H D4N-9A2H D4N-9B2H
2-conduit G1/2 D4N-612H D4N-622H D4N-6A2H D4N-6B2H
M20 D4N-812H D4N-822H D4N-8A2H D4N-8B2H
http://www.ia.omron.com/ 2
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Switches with Three Contacts and MBB Contacts (with Direct Opening Mechanism)
Note:
It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North American countries.
Actuator Conduit size
Built-in switch mechanism
2NC/1NO
(Slow-action)
3NC
(Slow-action)
1NC/1NO MBB
(Slow-action)
2NC/1NO MBB
(Slow-action)
Model Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening
Roller lever (resin
lever, resin roller)
1-conduit
Pg13.5 D4N-1C20 D4N-1D20 D4N-1E20 D4N-1F20
G1/2 D4N-2C20 D4N-2D20 D4N-2E20 D4N-2F20
1/2-14NPT D4N-3C20 D4N-3D20 D4N-3E20 D4N-3F20
M20 D4N-4C20 D4N-4D20 D4N-4E20 D4N-4F20
M12 connector --- --- D4N-9E20 ---
2-conduit
Pg13.5 D4N-5C20 D4N-5D20 D4N-5E20 D4N-5F20
G1/2 D4N-6C20 D4N-6D20 D4N-6E20 D4N-6F20
M20 D4N-8C20 D4N-8D20 D4N-8E20 D4N-8F20
Roller lever (metal
lever, resin roller)
1-conduit
Pg13.5 D4N-1C22 D4N-1D22 D4N-1E22 D4N-1F22
G1/2 D4N-2C22 D4N-2D22 D4N-2E22 D4N-2F22
1/2-14NPT D4N-3C22 D4N-3D22 D4N-3E22 D4N-3F22
M20 D4N-4C22 D4N-4D22 D4N-4E22 D4N-4F22
M12 connector --- --- D4N-9E22 ---
2-conduit
Pg13.5 D4N-5C22 D4N-5D22 D4N-5E22 D4N-5F22
G1/2 D4N-6C22 D4N-6D22 D4N-6E22 D4N-6F22
M20 D4N-8C22 D4N-8D22 D4N-8E22 D4N-8F22
Roller lever (metal
lever, metal roller)
1-conduit
Pg13.5 D4N-1C25 D4N-1D25 D4N-1E25 D4N-1F25
G1/2 D4N-2C25 D4N-2D25 D4N-2E25 D4N-2F25
1/2-14NPT D4N-3C25 D4N-3D25 D4N-3E25 D4N-3F25
M20 D4N-4C25 D4N-4D25 D4N-4E25 D4N-4F25
M12 connector --- --- D4N-9E25 ---
Roller lever (metal
lever, bearing roller)
1-conduit
Pg13.5 D4N-1C26 D4N-1D26 D4N-1E26 D4N-1F26
G1/2 D4N-2C26 D4N-2D26 D4N-2E26 D4N-2F26
1/2-14NPT D4N-3C26 D4N-3D26 D4N-3E26 D4N-3F26
M20 D4N-4C26 D4N-4D26 D4N-4E26 D4N-4F26
M12 connector --- --- D4N-9E26 ---
Plunger
1-conduit
Pg13.5 D4N-1C31 D4N-1D31 D4N-1E31 D4N-1F31
G1/2 D4N-2C31 D4N-2D31 D4N-2E31 D4N-2F31
1/2-14NPT D4N-3C31 D4N-3D31 D4N-3E31 D4N-3F31
M20 D4N-4C31 D4N-4D31 D4N-4E31 D4N-4F31
M12 connector --- --- D4N-9E31 ---
2-conduit
Pg13.5 D4N-5C31 D4N-5D31 D4N-5E31 D4N-5F31
G1/2 D4N-6C31 D4N-6D31 D4N-6E31 D4N-6F31
M20 D4N-8C31 D4N-8D31 D4N-8E31 D4N-8F31
Roller plunger
1-conduit
Pg13.5 D4N-1C32 D4N-1D32 D4N-1E32 D4N-1F32
G1/2 D4N-2C32 D4N-2D32 D4N-2E32 D4N-2F32
1/2-14NPT D4N-3C32 D4N-3D32 D4N-3E32 D4N-3F32
M20 D4N-4C32 D4N-4D32 D4N-4E32 D4N-4F32
M12 connector --- --- D4N-9E32 ---
2-conduit
Pg13.5 D4N-5C32 D4N-5D32 D4N-5E32 D4N-5F32
G1/2 D4N-6C32 D4N-6D32 D4N-6E32 D4N-6F32
M20 D4N-8C32 D4N-8D32 D4N-8E32 D4N-8F32
One-way roller arm
lever (horizontal)
1-conduit
Pg13.5 D4N-1C62 D4N-1D62 D4N-1E62 D4N-1F62
G1/2 D4N-2C62 D4N-2D62 D4N-2E62 D4N-2F62
1/2-14NPT D4N-3C62 D4N-3D62 D4N-3E62 D4N-3F62
M20 D4N-4C62 D4N-4D62 D4N-4E62 D4N-4F62
M12 connector --- --- D4N-9E62 ---
2-conduit
Pg13.5 D4N-5C62 D4N-5D62 D4N-5E62 D4N-5F62
G1/2 D4N-6C62 D4N-6D62 D4N-6E62 D4N-6F62
M20 D4N-8C62 D4N-8D62 D4N-8E62 D4N-8F62
One-way roller arm
lever (vertical)
1-conduit
Pg13.5 D4N-1C72 D4N-1D72 D4N-1E72 D4N-1F72
G1/2 D4N-2C72 D4N-2D72 D4N-2E72 D4N-2F72
1/2-14NPT D4N-3C72 D4N-3D72 D4N-3E72 D4N-3F72
M20 D4N-4C72 D4N-4D72 D4N-4E72 D4N-4F72
M12 connector --- --- D4N-9E72 ---
2-conduit
Pg13.5 D4N-5C72 D4N-5D72 D4N-5E72 D4N-5F72
G1/2 D4N-6C72 D4N-6D72 D4N-6E72 D4N-6F72
M20 D4N-8C72 D4N-8D72 D4N-8E72 D4N-8F72
Adjustable roller
lever, form lock
(metal lever, resin
roller) 1-conduit
Pg13.5 D4N-1C2G D4N-1D2G D4N-1E2G D4N-1F2G
G1/2 D4N-2C2G D4N-2D2G D4N-2E2G D4N-2F2G
1/2-14NPT D4N-3C2G D4N-3D2G D4N-3E2G D4N-3F2G
M20 D4N-4C2G D4N-4D2G D4N-4E2G D4N-4F2G
M12 connector --- --- D4N-9E2G ---
2-conduit G1/2 D4N-6C2G D4N-6D2G D4N-6E2G D4N-6F2G
M20 D4N-8C2G D4N-8D2G D4N-8E2G D4N-8F2G
Adjustable roller
lever, form lock
(metal lever, rubber
roller) 1-conduit
Pg13.5 D4N-1C2H D4N-1D2H D4N-1E2H D4N-1F2H
G1/2 D4N-2C2H D4N-2D2H D4N-2E2H D4N-2F2H
1/2-14NPT D4N-3C2H D4N-3D2H D4N-3E2H D4N-3F2H
M20 D4N-4C2H D4N-4D2H D4N-4E2H D4N-4F2H
M12 connector --- --- D4N-9E2H ---
2-conduit G1/2 D4N-6C2H D4N-6D2H D4N-6E2H D4N-6F2H
M20 D4N-8C2H D4N-8D2H D4N-8E2H D4N-8F2H
http://www.ia.omron.com/ 3
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
General-purpose Switches with Two Contacts
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. Mechanically speaking, these models are basic limit switches.
General-purpose Switches with Three Contacts and MBB Contacts
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. Mechanically speaking, these models are basic limit switches.
Actuator Conduit size
Built-in switch mechanism
1NC/1NO
(Snap-action)
2NC
(Snap-action)
1NC/1NO
(Slow-action)
2NC
(Slow-action)
Model Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening
Fork lever lock
(right operation) 1-conduit
G1/2
---
---
---
---
D4N-2ARE
---
D4N-2BRE
---
1/2-14NPT D4N-3ARE D4N-3BRE
M20 D4N-4ARE D4N-4BRE
2-conduit G1/2 --- --- D4N-6ARE --- D4N-6BRE ---
M20 D4N-8ARE D4N-8BRE
Fork lever lock (left
operation) 1-conduit
G1/2
--- ---
D4N-2ALE
---
D4N-2BLE
---
1/2-14NPT D4N-3ALE D4N-3BLE
M20 D4N-4ALE D4N-4BLE
2-conduit G1/2 --- --- D4N-6ALE --- D4N-6BLE ---
M20 D4N-8ALE D4N-8BLE
Cat whisker
1-conduit
G1/2 D4N-2180
---
D4N-2280
---
---
---
D4N-2B80
---
1/2-14NPT D4N-3180 D4N-3280 D4N-3B80
M20 D4N-4180 D4N-4280 D4N-4B80
2-conduit G1/2 D4N-6180 --- D4N-6280 --- --- D4N-6B80 ---
M20 D4N-8180 D4N-8280 D4N-8B80
Plastic rod
1-conduit
G1/2 D4N-2187
---
D4N-2287
--- ---
D4N-2B87
---
1/2-14NPT D4N-3187 D4N-3287 D4N-3B87
M20 D4N-4187 D4N-4287 D4N-4B87
2-conduit G1/2 D4N-6187 --- D4N-6287 --- --- D4N-6B87 ---
M20 D4N-8187 D4N-8287 D4N-8B87
Actuator Conduit size
Built-in switch mechanism
2NC/1NO
(Slow-action)
3NC
(Slow-action)
1NC/1NO MBB
(Slow-action)
2NC/1NO MBB
(Slow-action)
Model Direct
opening Model Direct
opening Model Direct
opening Model Direct
opening
Fork lever lock
(right operation) 1-conduit
G1/2 D4N-2CRE
---
D4N-2DRE
---
D4N-2ERE
---
D4N-2FRE
---
1/2-14NPT D4N-3CRE D4N-3DRE D4N-3ERE D4N-3FRE
M20 D4N-4CRE D4N-4DRE D4N-4ERE D4N-4FRE
2-conduit G1/2 D4N-6CRE --- D4N-6DRE --- D4N-6ERE --- D4N-6FRE ---
M20 D4N-8CRE D4N-8DRE D4N-8ERE D4N-8FRE
Fork lever lock
(left operation) 1-conduit
G1/2 D4N-2CLE
---
D4N-2DLE
---
D4N-2ELE
---
D4N-2FLE
---
1/2-14NPT D4N-3CLE D4N-3DLE D4N-3ELE D4N-3FLE
M20 D4N-4CLE D4N-4DLE D4N-4ELE D4N-4FLE
2-conduit G1/2 D4N-6CLE --- D4N-6DLE --- D4N-6ELE --- D4N-6FLE ---
M20 D4N-8CLE D4N-8DLE D4N-8ELE D4N-8FLE
Cat whisker
1-conduit
G1/2
---
---
D4N-2D80
---
---
---
---
---
1/2-14NPT D4N-3D80
M20 D4N-4D80
2-conduit G1/2 --- D4N-6D80 --- --- ---
M20 D4N-8D80
Plastic rod
1-conduit
G1/2
---
D4N-2D87
--- --- ---
1/2-14NPT D4N-3D87
M20 D4N-4D87
2-conduit G1/2 --- D4N-6D87 --- --- ---
M20 D4N-8D87
http://www.ia.omron.com/ 4
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Specifications
Standards and EC Directives
Conforms to the following EC Directives:
xMachinery Directive
xLow Voltage Directive
xEN50047
xEN60204-1
xEN1088
xGS-ET-15
Certified Standards
*1.Consult your OMRON representative for details.
*2.Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*3.Ask your OMRON representative for information on certified
models.
Certified Standard Ratings
TÜV (EN60947-5-1), CCC (GB14048.5)
Note: Use a 10 A fuse type gI or gG that conforms to IEC269 as a
short-circuit protection device. This fuse is not built into the
Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Q300
Certification
body Standard File No.
TÜV Product
Service
EN60947-5-1
(certified direct opening) *1
UL *2 UL508, CSA C22.2 No.14 E76675
CQC (CCC) *3 GB14048.5
2004010305105973
Item Utilization
category AC-15 DC-13
Rated operating current (Ie)3 A 0.27 A
Rated operating voltage (Ue)240 V 250 V
Rated
voltage Carry current Current (A)
Volt-amperes (VA)
Make Break Make Break
120 VAC 10 A 60 6 7,200 720
240 VAC 30 3
Rated
voltage Carry current Current (A)
Volt-amperes (VA)
Make Break Make Break
125 VDC 2.5 A 0.55 0.55 69 69
250 VDC 0.27 0.27
http://www.ia.omron.com/ 5
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Characteristics
Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity.
Doing so may result in roughening of the contact surface and contact reliability may be lost.
*1.The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for
the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4N
in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise, accelerated wear, Switch
damage or malfunctioning may occur.
*2.The durability is for an ambient temperature of 5 to 35qC and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
*3.Do not pass the 3 A, 250 VAC load through more than 2 circuits.
*4.This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load
beforehand.
*5.The mechanical durability of fork lever lock models is 10,000,000 operations min.
Degree of protection *1 IP67 (EN60947-5-1)
Durability *2
Mechanical 15,000,000 operations min. *5
Electrical 500,000 operations min. (3 A resistive load at 250 VAC) *3
300,000 operations min. (10 A resistive load at 250 VAC)
Operating speed 1 to 500 mm/s (D4N-1120)
Operating frequency 30 operations/minute max.
Contact resistance 25 m:max.
Minimum applicable load *4 1 mA resistive load at 5 VDC (N-level reference value)
Rated insulation voltage (Ui)300 V
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse withstand
voltage
(EN60947-5-1)
Between terminals of
same polarity 2.5 kV
Between terminals of
different polarity 4 kV
Between each terminal
and non-current carrying
metallic parts 6 kV
Insulation resistance 100 M:min.
Contact gap Snap-action: 2 u0.5 mm min.
Slow-action: 2 u2 mm min.
Vibration resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude
Shock resistance Destruction 1,000 m/s2min.
Malfunction 300 m/s2min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional free air thermal current (Ith)10 A (EN60947-5-1)
Ambient operating temperature 30to 70qC (with no icing)
Ambient operating humidity 95% max.
Weight Approx. 82 g (D4N-1120)
Approx. 99 g (D4N-5120)
http://www.ia.omron.com/ 6
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Structure and Nomenclature
Structure
Direct Opening Mechanism
1NC/1NO Contact (Slow-action) 2NC Contact (Slow-action)
Pg13.5
G1/2
1/2-14NPT
M20
M12 connector
Note: M12 connector types are not available for
Switches with three contacts.
Head
The direction of the switch head can be varied to any of
the four directions. (Roller plunger models can be
mounted in either of two directions at a 90° angle.)
Conduit Opening
A wide variety of conduits is available.
Built-in Switch
The built-in switch has a direct opening mechanism
that forcibly separates the NC contact even when
there is contact deposit.
Safety-oriented Lever Setting
(Form-lock construction)
Grooves which engage the lever are cut in the lever and
rotary shaft to prevent the lever from slipping against the
rotary shaft.
There are resin-lever and metal-lever types.
Cover
The cover, with a hinge on its lower part, can
be opened by removing the screw of the
cover, which ensures ease of maintenance
and wiring.
Size Box 1-conduit 2-conduit
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
---
Contact spring
Return spring
Fixed contact (NC)
Fixed contact (NO)
Plunger
Movable contact
Conforms to EN60947-5-1 Direct Opening Operation
(Only the NC contact side has a direct opening
mechanism.)
When contact welding occurs, the contacts are
separated from each other by the plunger being
pushed in.
Contact spring
Fixed contact (NC)
Plunger
Movable contact
Return spring
Conforms to EN60947-5-1 Direct Opening Operation
(Both NC contacts have a direct opening
mechanism.)
http://www.ia.omron.com/ 7
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Contact Form
Note: Terminals are numbered according to EN50013 and the contact forms are according to IEC947-5-1.
* MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open
contact (NO) closes.
Model Contact Contact form Operating pattern Remarks
D4N-@1@1NC/1NO
(Snap-action)
D4N-@2@2NC (Snap-action)
D4N-@A@1NC/1NO
(Slow-action)
D4N-@B@2NC (Slow-action)
D4N-@C@2NC/1NO
(Slow-action)
D4N-@D@3NC (Slow-action)
D4N-@E@1NC/1NO MBB *
(Slow-action)
D4N-@F@2NC/1NO MBB *
(Slow-action)
14
32
13
31
Zb
ON
Stroke
13-14
31-32
Only NC contacts 31-32 have a
certified direct opening
mechanism.
The terminals 13-14 and 31-32
can be used as unlike poles.
11
31
12
32
Zb
ON
Stroke
11-12
31-32
Only NC contacts 11-12 and
31-32 have a certified direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
11
33
12
34
Zb
ON
Stroke
11-12
33-34
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
11
31
12
32
Zb
ON
Stroke
11-12
31-32
Only NC contacts 11-12 and
31-32 have a certified direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
33 34
11
21
12
22
Zb
ON
Stroke
21-22
33-34
11-12
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
33-34 can be used as unlike
poles.
11
21
12
22
31 32
Zb
ON
Stroke
11-12
21-22
31-32
Only NC contacts 11-12, 21-22,
and 31-32 have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
31-32 can be used as unlike
poles.
11
33
12
34
Zb
ON
Stroke
11-12
33-34
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
33 34
11
21
12
22
Zb
ON
Stroke
11-12
21-22
33-34
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22 and
33-34 can be used as unlike poles.
http://www.ia.omron.com/ 8
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Dimensions and Operating Characteristics (Unit: mm)
Switches
1-conduit Models
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
* Refer to page 12 for details on M12 connectors.
Roller Lever (Resin Lever, Resin Roller)
D4N-1@20 D4N-2@20
D4N-3@20 D4N-4@20
D4N-9@20 * 17.5 dia. ×6.8
resin roller
Two, 4 +0.15 dia. holes
Depth: 5
0
30
27.5
11±0.2
47±1
40±1
(27)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
18
20±0.1
22±0.1
14.2
Resin lever
2.15±0.05R
mounting holes
Conduit cap
20.5 ×20.5
Roller Lever (Metal Lever, Resin Roller)
D4N-1@22 D4N-2@22
D4N-3@22 D4N-4@22
D4N-9@22 * 17.5 dia. ×6.8
resin roller
Two, 4 +0.15 dia. holes
Depth: 5
0
30
27.5
11±0.2
45±1
39.5±1
(31)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
18
20±0.1
22±0.1
14.2
Metal lever
2.15±0.05R
mounting holes
Conduit cap
20.5 ×20.5
Roller Lever (Metal Lever, Metal Roller)
D4N-1@25 D4N-2@25
D4N-3@25 D4N-4@25
D4N-9@25 * 17.5 dia. ×7
sintered stainless
steel roller
Two, 4 +0.15 dia. holes
Depth: 5
0
30
27.5
11±0.2
45±1
39.5±1
(31)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
18
20±0.1
22±0.1
14.2
Metal lever 20.5 ×20.5
2.15±0.05R
mounting holes
Conduit cap
Roller Lever (Metal Lever, Bearing Roller)
D4N-1@26 D4N-2@26
D4N-3@26 D4N-4@26
D4N-9@26 * 17 dia. ×6
Bearing roller
Two, 4 +0.15 dia. holes
Depth: 5
0
Metal lever 20.5 ×20.5
2.15±0.05R
mounting holes
Conduit cap 30
27.5
11±0.2
43.6±1
39±1
(31.5)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
18
20±0.1
22±0.1
14.2
Snap-action (1NC/1NO) (2NC), Slow-action (2NC)
(3NC)
Note: Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact
operation.
*1.Only for snap-action models.
*2.Reference value.
*3.For safe use, always make sure that the minimum values or greater
are provided.
Model
Operating characteristics
D4N-@120
D4N-@220
D4N-
@
B20
D4N-
@
D20
D4N-@122
D4N-@222
D4N-
@
B22
D4N-
@
D22
D4N-@125
D4N-@225
D4N-
@
B25
D4N-
@
D25
D4N-@126
D4N-@226
D4N-
@
B26
D4N-
@
D26
Operating force OF max. 5.0 N
Release force RF min. 0.5 N
Pretravel PT 18qto 27q
Overtravel OT min. 40q
Movement differential MD max.
*1
14q
Operating position OP ---
Total travel TT *2 (80q)
Direct opening travel DOT min.
*3
50q
Direct opening force DOF min.
*3
20 N
Slow-action (1NC/1NO) (2NC/1NO)
*1. These PT values are possible when the NC contacts are open (OFF).
*2. These PT values are possible when the NO contacts are closed (ON).
*3.Only for MBB models.
*4.Reference values for MBB models only.
*5.Reference values.
*6.For safe use, always make sure that the minimum values or greater
are provided.
Model
Operating characteristics
D4N-
@
A20
D4N-
@
C20
D4N-
@
E20
D4N-@F20
D4N-
@
A22
D4N-
@
C22
D4N-
@
E22
D4N-@F22
D4N-
@
A25
D4N-
@
C25
D4N-
@
E25
D4N-@F25
D4N-
@
A26
D4N-
@
C26
D4N-
@
E26
D4N-@F26
Operating force OF max. 5.0 N
Release force RF min. 0.5 N
PT *1 18qto 27q
PT (2nd)
*2
(44q)
PT *3 27.5qto 36.5q
PT (2nd)
*4
(18q)
Overtravel OT min. 40q
Operating position OP ---
Total travel TT *5 (80q)
Direct opening travel DOT min.
*6
50q
Direct opening force DOF min.
*6
20 N
http://www.ia.omron.com/ 9
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
1-conduit Models
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
* Refer to page 12 for details on M12 connectors.
Plunger
D4N-1@31 D4N-2@31
D4N-3@31 D4N-4@31
D4N-9@31 *
Two, 3±0.05 dia.
holes
6-dia. resin
plunger
Two, 4+0.15 dia. holes
Depth: 5
0
30
(31.5)
21.5
25
±0.1
11
±0.2
22
±0.2
31 max.
55 47
±0.2
2.5
9
±0.2
OP
20
±0.1
22
±0.1
14.2
12 dia.
2.15±0.05R
mounting holes
Conduit cap
Roller Plunger
D4N-1@32 D4N-2@32
D4N-3@32 D4N-4@32
D4N-9@32 *
9.5 dia. ×5
resin roller
Two, 4
+0.15
dia. holes
Depth: 5
0
30
25.2
11±0.2
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
OP
20±0.1
22±0.1
14.2
(31.5)
21.5
20.5 ×20.5
2.15±0.05R
mounting holes
Conduit cap
Two, 4
+0.15 dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Horizontal)
D4N-1@62 D4N-2@62
D4N-3@62 D4N-4@62
D4N-9@62 *
Operating direction
12.5 dia. ×5
resin roller
30
14.8
23.3
13.5
19.5±0.2
11±0.2
11±0.2
20R 10.2
22±0.2
31 max.
47±0.2
2.5
9±0.2
OP
20±0.1
22±0.1
14.2
55
(31.5)
21.5
2.15±0.05R
mounting holes
Conduit cap
Two, 4+0.15
dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Vertical)
D4N-1@72 D4N-2@72
D4N-3@72 D4N-4@72
D4N-9@72 *
Operating
direction
12 dia. ×5
resin roller
30
OP
14.7
19R
19.5±0.2
11±0.2
11±0.2 12
10.2
22±0.2
31 max.
47±0.2
2.5
9±0.2
20±0.1
22±0.1
14.2
(31.5)
55
21.5
2.15±0.05R
mounting holes
Conduit cap
http://www.ia.omron.com/ 10
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Slow-action (1NC/1NO) (2NC/1NO)
Model
Operating characteristics
D4N-@131
D4N-@231
D4N-@B31
D4N-@D31
D4N-@132
D4N-@232
D4N-@B32
D4N-@D32
D4N-@162
D4N-@262
D4N-@B62
D4N-@D62
D4N-@172
D4N-@272
D4N-@B72
D4N-@D72
Operating force OF max. 6.5 N 6.5 N 5.0 N 5.0 N Note: Variation occurs in the simultaneity
of contact opening/closing
operations of 2NC, 2NC/1NO, and
3NC contacts. Check contact
operation.
*1.Only for snap-action models.
*2.Reference value.
*3.For safe use, always make sure that
the minimum values or greater are
provided.
Release force RF min. 1.5 N 1.5 N 0.8 N 0.8 N
Pretravel PT max. 2 mm 2 mm 4 mm 4 mm
Overtravel OT min. 4 mm 4 mm 5 mm 5 mm
Movement differential MD max. *1 1 mm 1 mm 1.5 mm 1.5 mm
Operating position OP
18.2
r
0.5 mm 28.6
r
0.8 mm
37 r0.8 mm 27 r0.8 mm
Total travel TT *2 (6 mm) (6 mm) (9 mm) (9 mm)
Direct opening travel DOT min. *3 3.2 mm 3.2 mm 5.8 mm 4.8 mm
Direct opening force DOF min. *3 20 N 20 N 20 N 20 N
Model
Operating characteristics
D4N-@A31
D4N-@C31
D4N-@E31
D4N-@F31
D4N-@A32
D4N-@C32
D4N-@E32
D4N-@F32
D4N-@A62
D4N-@C62
D4N-@E62
D4N-@F62
D4N-@A72
D4N-@C72
D4N-@E72
D4N-@F72
Operating force OF max. 6.5 N 6.5 N 5.0 N 5.0 N
*1.These PT values are possible when
the NC contacts are open (OFF).
*2.These PT values are possible when
the NO contacts are closed (ON).
*3.Only for MBB models.
*4.Reference values for MBB models.
*5.Only for MBB models.
*6.Reference value.
*7.For safe use, always make sure that
the minimum values or greater are
provided.
Release force RF min. 1.5 N 1.5 N 0.8 N 0.8 N
Pretravel PT max. *1 2 mm 2 mm 4 mm 4 mm
PT (2nd) *2 (2.9 mm) (2.9 mm) (5.2 mm) (4.3 mm)
PT max. *3 2.8 mm 2.8 mm 4 mm 4 mm
PT (2nd) *4 (1 mm) (1 mm) (1.5 mm) (1.5 mm)
Overtravel OT min. 4 mm 4 mm 5 mm 5 mm
Operating position OP
18.2
r
0.5 mm 28.6
r
0.8 mm
37 r0.8 mm 27 r0.8 mm
OP *5
17.4
r
0.5 mm
28 r0.8 mm 36 r0.8 mm
26.1
r
0.8 mm
Total travel TT *6 (6 mm) (6 mm) (9 mm) (9 mm)
Direct opening travel DOT min. *7 3.2 mm 3.2 mm 5.8 mm 4.8 mm
Direct opening force DOF min. *7 20 N 20 N 20 N 20 N
http://www.ia.omron.com/ 11
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
1-conduit Models
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
* Refer to following diagrams for details on M12 connectors.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Slow-action (1NC/1NO) (2NC/1NO)
Model
Operating characteristics
D4N-@12H
D4N-@22H
D4N-@B2H
D4N-@D2H
D4N-@12G
D4N-@22G
D4N-@B2G
D4N-@D2G
*1
Operating force OF max. 4.5 N
Note: Variation occurs in the simultaneity of contact
opening/closing operations of 2NC, 2NC/1NO, and
3NC contacts. Check contact operation.
*1.The operating characteristics of these Switches were
measured with the roller lever set at 32 mm.
*2.Only for snap-action models.
*3.Reference value.
*4.For safe use, always make sure that the minimum values
or greater are provided.
Release force RF min. 0.4 N
Pretravel PT 18qto 27q
Overtravel OT min. 40q
Movement differential MD max. *2 14q
Operating position OP ---
Total travel TT *3 (80q)
Direct opening travel DOT min. *4 50q
Direct opening force DOF min. *4 20 N
Model
Operating characteristics
D4N-@A2H
D4N-@C2H
D4N-@E2H
D4N-@F2H
D4N-@A2G
D4N-@C2G
D4N-@E2G
D4N-@F2G
*1
Operating force OF max. 4.5 N
*1.The operating characteristics of these Switches were
measured with the roller lever set at 32 mm.
*2.This PT value is possible when the NC contacts are open
(OFF).
*3.This PT value is possible when the NO contacts are
closed (ON).
*4.Only for MBB models.
*5.Reference value for MBB models only.
*6.Reference value.
*7.For safe use, always make sure that the minimum values
or greater are provided.
Release force RF min. 0.4 N
Pretravel PT *2 18qto 27q
PT (2nd) *3 (44q)
PT *4 27.5qto 36.5q
PT (2nd) *5 (18q)
Overtravel OT min. 40q
Operating position OP ---
Total travel TT *6 (80q)
Direct opening travel DOT min. 50q
Direct opening force DOF min. *7 20 N
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
D4N-1@2G D4N-2@2G
D4N-3@2G D4N-4@2G
D4N-9@2G * 17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
2.15±0.05R
mounting holes
Conduit cap
20.5 ×20.5
30
27.5
11
±0.2
21.5
22
±0.2
31 max.
55 47
±0.2
2.5
9
±0.2
20 to 66R
18
20
±0.1
22
±0.1
14.2
45
±1
39.5
±1
(31)
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
D4N-1@2H D4N-2@2H
D4N-3@2H D4N-4@2H
D4N-9@2H * 50 dia. ×8
rubber roller
Bearing
Stainless steel
lever
Two, 4+0.15 dia. holes
Depth: 5
0
20.5 ×20.5
30
27.5
11±0.2
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
18
20±0.1
22±0.1
14.2
48.2±1
41.3±1
(29.2)
32 to 66R
2.15±0.05R
mounting holes
Conduit cap
1-conduit M12 Connector
D4N-9@@@
(14)
M12 ×1
14.2
30
http://www.ia.omron.com/ 12
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
1-conduit Models
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
* The usable range for stainless steel wires and resin rods is 35 mm max. from the end with a total travel of 70 mm max.
Slow-action (1NC/1NO) (2NC/1NO) (2NC) (3NC)
Note: Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
20.5 ×20.5
Two, 4+0.15 dia. holes
Depth: 5
0
Fork Lever Lock
(Right Operation)
D4N-1@RE D4N-2@RE
D4N-3@RE D4N-4@RE
2.15±0.05R
mounting
holes
30
27.5
11±0.2
47 max.
39.3±1
(27.2)
21.5
22±0.2
31 max.
55 47±0.2
2.5
9±0.2
26R
90°
18
20±0.1
22±0.1
14.2
Two, 17.5 dia.
×8 rubber
rollers
Conduit cap
Two, 4+0.15
dia. holes
Depth: 5
0
Fork Lever Lock
(Left Operation)
D4N-1@LE D4N-2@LE
D4N-3@LE D4N-4@LE
2.15±0.05R
mounting holes
Two, 17.5 dia. ×
8 rubber rollers
30
27.5
11±
0.2
39.3±
1
(27.2)
21.5
22±
0.2
31 max.
55
47±
0.2
2.5
9±
0.2
26R 90°
18
20±
0.1
22±
0.1
14.2
47 max.
20.5 ×20.5
Conduit cap
Two, 4
+0.15
dia. holes
Depth: 5
0
Cat Whisker
D4N-1@80 D4N-2@80
D4N-3@80 D4N-4@80
1.2-dia.
stainless
steel wire *
2.15±0.05R
mounting holes
30
(31.5)
11±
0.2
21.5
22±
0.2
31 max.
55 47±
0.2
2.5
9±
0.2
(50.1)
PT
143.1
20±
0.1
22±
0.1
14.2
20.5 ×20.5
Sealing cap
16.6 dia.
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
Plastic Rod
D4N-1@87 D4N-2@87
D4N-3@87 D4N-4@87
2.15±0.05R
mounting holes
30
(31.5)
11±0.2
22±0.2
31 max.
55
115
38
42
12±0.2
47±0.2
2.5
PT
20±0.1
22±0.1
14.2
21.5
9±0.2
Resin rod *
20.5 ×
20.5
Sealing cap 16.6 dia.
Conduit cap
Model
Operating characteristics D4N-@@RE D4N-@@LE
Force necessary to reverse
the direction of the lever:
max. 6.4 N 6.4 N
Movement until the lever
reverses 55r10q55r10q
Movement until switch
operation (NC) (6.5q
(MBB: 10q)
(6.5q
(MBB: 10q)
Movement until switch
operation (NO) (18.5q
(MBB: 5q)
(18.5q
(MBB: 5q)
Model
Operating characteristics D4N-@@80 D4N-@@87
Operating force OF max. 1.5 N 1.5 N
Pretravel PT max. 15q15q
http://www.ia.omron.com/ 13
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
2-conduit Models
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
Roller Lever (Resin Lever, Resin Roller)
D4N-5@20
D4N-6@20
D4N-8@20
17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
27.5
20.5
20.5 ×20.5
11±0.2
47±1
40±1
(27)
21.5
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
2.5
5.4
9±0.2
26R
18
20±0.1
40±0.1
42
±0.1
22±0.1
14.2
Resin lever
2.15±0.05R
mounting
holes
Conduit
cap
Roller Lever (Metal Lever, Resin Roller)
D4N-5@22
D4N-6@22
D4N-8@22 17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
27.5
20.5
11±0.2
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
18
20±0.1
40±0.1
42±0.1
22±0.1
14.2
26R
45±1
39.5±1
(31)
39±0.2
Metal lever 20.5 ×20.5
2.15±0.05R
mounting
holes
Conduit cap
Plunger
D4N-5@31
D4N-6@31
D4N-8@31
Two, 3±0.05
dia. holes
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
20.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
OP
20±0.1
40±0.1
42±0.1
22±0.1
14.2
(31.5)
21.5
11±0.2
25±0.1
12 dia.
39±0.2
6-dia. resin plunger
2.15±0.05R
mounting
holes
Conduit cap
Roller Plunger
D4N-5@32
D4N-6@32
D4N-8@32
9.5 dia. ×5
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
20.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
OP 25.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
11±0.2
(31.5)
21.5
39±0.2
20.5 ×20.5
2.15±0.05R
mounting
holes
Conduit cap
Snap-action (1NC/1NO) (2NC), Slow-action (2NC)
(3NC)
Note: Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
*1.Only for snap-action models.
*2.Reference value.
*3.For safe use, always make sure that the minimum values or greater
are provided.
Model
Operating characteristics
D4N-
@
120
D4N-
@
220
D4N-
@
B20
D4N-
@
D20
D4N-
@
122
D4N-
@
222
D4N-
@
B22
D4N-
@
D22
D4N-@131
D4N-@231
D4N-@B31
D4N-@D31
D4N-
@
132
D4N-
@
232
D4N-
@
B32
D4N-
@
D32
Operating force
OF max.
5 N 5 N 6.5 N 6.5 N
Release force RF min. 0.5 N 0.5 N 1.5 N 1.5 N
Pretravel PT 18qto 27q18qto 27q2 mm 2 mm
Overtravel OT min. 40q40q4 mm 4 mm
Movement differential
MDmax.
*1
14q14q1 mm 1 mm
Operating position OP --- --- 18
r0.5 mm
28.2
r0.8 mm
Total travel TT *2 (80q)(80q) (6 mm) (6 mm)
Direct opening travel
DOTmin.
*3
50q50q3.2 mm 3.2 mm
Direct opening force
DOFmin.
*3
20 N 20 N 20 N 20 N
Slow-action (1NC/1NO) (2NC/1NO)
*1.This PT value is possible when the NC contacts are open (OFF).
*2.This PT value is possible when the NO contacts are closed (ON).
*3.Only for MBB models.
*4.Reference value for MBB models.
*5.Only for MBB models.
*6.Reference value.
*7.For safe use, always make sure that the minimum values or
greater are provided.
Model
Operating characteristics
D4N-
@
A20
D4N-
@
C20
D4N-
@
E20
D4N-@F20
D4N-
@
A22
D4N-
@
C22
D4N-
@
E22
D4N-@F22
D4N-
@
A31
D4N-
@
C31
D4N-
@
E31
D4N-@F31
D4N-
@
A32
D4N-
@
C32
D4N-
@
E32
D4N-@F32
Operating force OF max. 5 N 5 N 6.5 N 6.5 N
Release force RF min. 0.5 N 0.5 N 1.5 N 1.5 N
Pretravel PT *1 18qto 27q18qto 27q2 mm 2 mm
PT (2nd)
*2
(44q)(44q) (2.9 mm) (2.9 mm)
PT *3 27.5qto
36.5q
27.5qto
36.5q2.8 mm 2.8 mm
PT (2nd)
*4
(18q)(18q) (1 mm) (1 mm)
Overtravel OT min. 40q40q4 mm 4 mm
Operating position
OP --- --- 18
r0.5 mm
28.2
r0.8 mm
OP *5 --- --- 17.4
r0.5 mm
28
r0.8 mm
Total travel TT *6 (80q)(80q) (6 mm) (6 mm)
Direct opening travel
DOT min.
*7
50q50q3.2 mm 3.2 mm
Direct opening force
DOF min.
*7
20 N 20 N 20 N 20 N
http://www.ia.omron.com/ 14
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
2-conduit Models
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
v
Two, 4+0.15 dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Horizontal)
D4N-5@62
D4N-6@62
D4N-8@62
12 dia. x 5
resin roller
2.15±0.05R
mounting holes
30
Cap
20.5
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
11±0.2
10.2
(31.5)
14.8
Operating direction
23.3
13.5
11±0.2
19.5±0.2
20R
OP
21.5
39±0.2
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Vertical)
D4N-5@72
D4N-6@72
D4N-8@72
Operating
direction
12 dia. ×5
resin roller
30
Cap
20.5
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
OP
14.7
19R
19.5±0.2
11±0.2 12 11±0.2
10.2
(31.5)
21.5
39±0.2
2.15±0.05R
mounting
holes
Conduit cap
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
D4N-6@2G
D4N-8@2G 17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
30
Cap
27.5
20.5
11±0.2
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
18
20±0.1
40±0.1
42±0.1
22±0.1
14.2
45±1
39.5±1
(31)
39±0.2
20 to 66RResin lever
2.15±0.05R
mounting holes
Conduit cap
20.5 ×20.5
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
D4N-6@2H
D4N-8@2H 50 dia. ×8
rubber roller
Bearing
Stainless
steel lever
Two, 4+0.15 dia. holes
Depth: 5
0
20.5 ×20.5
30
Cap
27.5
20.5
11±0.2
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
18
20±0.1
40±0.1
42±0.1
22±0.1
14.2
48.2±1
41.3±1
(29.2)
39±0.2
32 to 66R
2.15±0.05R
mounting holes
Conduit cap
Snap-action (1NC/1NO) (2NC), Slow-action (2NC)
(3NC)
Note: Variation occurs in the simultaneity of contact opening/closing operations
of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation.
*1. The operating characteristics of these Switches were measured with the roller
lever set at 30 mm.
*2. The operating characteristics of these Switches were measured with the roller
lever set at 31 mm.
*3. Only for snap-action models.
*4. Reference value.
*5. For safe use, always make sure that the minimum values or greater are
provided.
Model
Operating characteristics
D4N-@162
D4N-@262
D4N-
@
B62
D4N-
@
D62
D4N-@172
D4N-@272
D4N-
@
B72
D4N-
@
D72
D4N-@12G
D4N-@22G
D4N-@B2G
D4N-@D2G
*1
D4N-@12H
D4N-@22H
D4N-@B2H
D4N-@D2H
*2
Operating force
OF max. 5.0N5.0N4.5N 4.5N
Release force RF min. 0.8 N 0.8 N 0.4 N 0.4 N
Pretravel PT max. 4 mm 4 mm 18qto 27q18qto 27q
Overtravel
OT min.
5 mm 5 mm 40q40q
Movement differential
MD max. *3
1.5 mm 1.5 mm 14q14q
Operating position
OP
37
r
0.8 mm 27
r
0.8 mm
--- ---
Total travel TT *4 (9 mm) (9 mm) (70q)(70q)
Direct opening travel
DOT min. *5
5.8 mm 4.8 mm 50q50q
Direct opening force
DOF min. *5
20 N 20 N 20 N 20 N
Slow-action (1NC/1NO) (2NC/1NO)
*1. The operating characteristics of these Switches were measured with the roller
lever set at 30 mm.
*2. The operating characteristics of these Switches were measured with the roller
lever set at 31 mm.
*3. This PT value is possible when the NC contacts are open (OFF).
*4. This PT value is possible when the NO contacts are closed (ON).
*5. Only for MBB models.
*6. Reference value for MBB models only.
*7. Only for MBB models.
*8. Reference value.
*9. For safe use, always make sure that the minimum values or greater are provided.
Model
Operating characteristics
D4N-
@
A62
D4N-
@
C62
D4N-
@
E62
D4N-@F62
D4N-
@
A72
D4N-
@
C72
D4N-
@
E72
D4N-@F72
D4N-@A2G
D4N-@C2G
D4N-@E2G
D4N-@F2G
*1
D4N-@A2H
D4N-@C2H
D4N-@E2H
D4N-@F2H
*2
Operating force OF max.
5.0 N 5.0 N 4.5 N 4.5 N
Release force RF min. 0.8 N 0.8 N 0.4 N 0.4 N
Pretravel PT max.
*3 4 mm 4 mm 18qto 27q18qto 27q
PT (2nd)
*4
(5.2 mm) (4.3 mm) (44q)(44q)
PT max.
*5 4 mm 4 mm
27.5
q
to 36.5
q
27.5
q
to 36.5
q
PT (2nd)
*6
(1.5 mm) (1.5 mm) (18q)(18q)
Overtravel OT min. 5 mm 5 mm 40q40q
Operating position
OP
37
r
0.8 mm 27
r
0.8 mm
--- ---
OP *7
36
r
0.8 mm
26.1
r0.8 mm --- ---
Total travel TT *8 (9 mm) (9 mm) (70q)(70q)
Direct opening travel
DOT min. *9
5.8 mm 4.8 mm 50q50q
Direct opening force
DOF min. *9
20 N 20 N 20 N 20 N
http://www.ia.omron.com/ 15
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
2-conduit Models
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
* The usable range for stainless steel wires and resin rods is 35 mm max. from the end with a total travel of 70 mm max.
Slow-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC)
Note: Variation occurs in the simultaneity of contact opening/closing
operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
Snap-action (1NC/1NO), Slow-action (2NC) (3NC)
Two, 4+0.15 dia. holes
Depth: 5
0
Fork Lever Lock
(Right Operation)
D4N-5@RE D4N-6@RE
D4N-7@RE D4N-8@RE
2.15±0.05R
mounting holes
30
Cap
27.5
20.5
11±0.2
21.5
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
18
20±0.1
40±0.1
42±0.1
22±0.1
14.2
39.3±1
(27.2)
26R
90°
47 max.
39±0.2
Two, 17.5 dia. ×
8 rubber rollers
Conduit cap
20.5 ×20.5
Two, 4+0.15 dia. holes
Depth: 5
0
Fork Lever Lock
(Left Operation)
D4N-5@LE D4N-6@LE
D4N-7@LE D4N-8@LE
2.15±0.05R
mounting holes
Cap
Two, 17.5 dia. ×
8 rubber rollers
20.5 ×20.5
30
27.5
20.5
11
±0.2
21.5
14.2
39.3
±1
(27.2)
42
±0.2
(3)
56 max.
47
25 dia.
2.5
5.4
9
±0.2
18
20
±0.1
40
±0.1
42
±0.1
22
±0.1
90°
26R
47 max.
39
±0.2
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
Cat Whisker
D4N-5@80 D4N-6@80
D4N-7@80 D4N-8@80
1.2-dia.
stainless
steel wire *
2.15±0.05R
mounting holes
30
Cap
20.5
11±0.2
16.6 dia.
42±0.2 (3)
56 max.
47
25 dia.
2.5
20.5 ×20.5
5.4
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
(50.1)
PT
143.1 21.5
(31.5)
39±0.2
Sealing cap
Conduit cap
Two, 4+0.15 dia. holes
Depth: 5
0
Plastic Rod
D4N-5@87 D4N-6@87
D4N-7@87 D4N-8@87
2.15±0.05R
mounting
holes
30
Cap
20.5
11±0.2
16.6 dia.
42±0.2 (3)
56 max.
47
25 dia.
2.5
5.4
9±0.2
12±0.2
20±0.1
40±0.1
42±0.1
22±0.1
14.2
115
38
42
PT
(31.5)
21.5
39±0.2
Resin rod *
Sealing cap
Conduit cap
Model
Operating characteristics D4N-@@RE D4N-@@LE
Force necessary to reverse the
direction of the lever: max. 6.4 N 6.4 N
Movement until the lever
reverses 55r10q55r10q
Movement until switch operation
(NC)
(6.5q)(6.5q)
(MBB: 10q)
Movement until switch operation
(NO)
(18.5q)(18.5q)
(MBB: 5q)
Model
Operating characteristics D4N-@@80 D4N-@@87
Operating force OF max. 1.5 N 1.5 N
Pretravel PT max. 15q15q
http://www.ia.omron.com/ 16
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Levers
Refer to the following for the angles and positions of the watchdogs (source: EN50047.)
Note: Unless otherwise specified, a tolerance of r0.4 mm applies to all dimensions.
Roller Lever
(D4N-@@20)
40
±2
15
±3
40
+1
0
55
50 max.
30°
20 min.
Dog
10 min.
Dog
5 min.
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
(D4N-@@2G) (Reference Values)
40±2
45
29±7
5±2
30°
30°
55+1
0
35+1
0
65R 20R
90
40 min.
Dog
15 min.
10 min.
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
(D4N-@@2H) (Reference Values)
42±2
110
75
30±7
11±3
30°
70+1
0
55+1
0
65R 31R
45 min.
25 min.
10 min.
Sealed Plunger
(D4N-@@31)
12.5
0
−2.5
18
±0.5
Dog
15 min. 21 min.
Dog
Operating position
Roller Plunger
(D4N-@@32)
25+1
0
35
28±1
10±1.5
2.5
30°
12.5 0
−2.5
Dog
20 min.
10 min.
Operating position
25 min. 31 min.
One-way Roller Arm Lever
(Horizontal)
(D4N-@@62)
30 max.
Dog
20 min.
31
+1
0
10
±2
40
5 min.
10 min.
30°
12.5
0
−2.5
One-way Roller Arm Lever
(Vertical) (Reference Values)
(D4N-@@72)
30°
20 min.
31
41
±2
22
+1
0
5 min.
10 min.
12.5
0
−2.5
Dog
Fork Lever Lock
(Right Operation)
(D4N-@@RE)
60
36
55°to 60°
5 to 9R
Dog setting range
40
28
Mounting
surface
Fork Lever Lock
(Left Operation)
(D4N-@@LE)
60
36
55°to 60°
5 to 9R
Dog setting range
40
28
Mounting
surface
http://www.ia.omron.com/ 17
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Safety Precautions
Refer to the “Precautions for All Switches” and “Precautions for All Safety Limit Switches”.
!CAUTION
xDo not use the Switch submerged in oil or water, or in locations
continuously subject to splashes of oil or water. Doing so may
result in oil or water entering the Switch interior. (The IP67 degree
of protection specification for the Switch refers to water penetration
while the Switch is submersed in water for a specified period of
time.)
xAlways attach the cover after completing wiring and before using
the Switch. Also, do not turn ON the Switch with the cover open.
Doing so may result in electric shock.
xDo not switch circuits for two or more standard loads (250 VAC,
3 A) at the same time. Doing so may adversely affect insulation
performance.
The Switch contacts can be used with either standard loads or
microloads. Once the contacts have been used to switch a load,
however, they cannot be used to switch smaller loads. The contact
surfaces will become rough once they have been used and contact
reliability for smaller loads may be reduced.
Mounting Method
Appropriate Tightening Torque
Tighten each of the screws to the specified torque. Loose screws may
result in malfunction of the Switch within a short time.
Switch Mounting
xMount the Switch using M4 screws and washers and tighten the
screws to the specified torque.
xFor safety, use screws that cannot be easily removed, or use an
equivalent measure to ensure that the Switch is secure.
xAs shown below, two studs with a maximum height of 4.8 mm and
a diameter of 4 mm can be provided, the studs inserted into the
holes on the bottom of the Switch, and the Switch secured at four
locations to increase the mounting strength.
Switch Mounting Holes
xMake sure that the dog contacts the actuator at a right angle.
Applying a load to the switch actuator (roller) on a slant may result
in deformation or damage of the actuator or rotary shaft.
Electric shock may occasionally occur.
Do not use metal connectors or metal conduits.
Precautions for Safe Use
Precautions for Correct Use
1Terminal screw 0.6 to 0.8 N·m
2Cover mounting screw 0.5 to 0.7 N·m
3Head mounting screw 0.5 to 0.6 N·m
4Lever mounting screw 1.6 to 1.8 N·m
5Body mounting screw 0.5 to 0.7 N·m
6Connector, M12 adaptor 1.8 to 2.2 N·m (except 1/2-14NPT)
1.4 to 1.8 N·m (for 1/2-14NPT)
7Cap screw 1.3 to 1.7 N·m
7
6
3
4
5
1
2
One-conduit Type Two-conduit Type
0.05
0.15
2.5
±0.1
22
±0.1
47
±0.1
20
±0.1
22
±0.1
Two, M4
−0.15
4−0.05 dia.
Height: 4.8 max.
42
±0.1
39
±0.1
20
±0.1
22
±0.1
40
±0.1
42
±0.1
2.5
±0.1
5.35
±0.1
Two, M4
−0.15
4−0.05 dia.
Height: 4.8 max.
Dog
Dog
CorrectIncorrect
http://www.ia.omron.com/ 18
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Wiring
Wiring
xWhen connecting to the terminals via insulating tube and M3.5
crimp terminals, arrange the crimp terminals as shown below so
that they do not rise up onto the case or the cover.
Applicable lead wire size: AWG20 to AWG18 (0.5 to 0.75 mm2).
Use lead wires of an appropriate length, as shown below. Not
doing so may result in excess length causing the cover to rise and
not fit properly.
One-conduit Type (3 Poles)
Two-conduit Type (3 Poles)
xDo not push crimp terminals into gaps in the case interior. Doing so
may cause damage or deformation of the case.
xUse crimp terminals not more than 0.5 mm in thickness. Otherwise,
they will interfere with other components inside the case.
[Reference] The crimp terminals shown below are not more than
0.5 mm thick.
Contact Arrangement
xThe contact arrangements are shown below.
Screw Terminal Type
Connector Type
xApplicable socket: XS2F (OMRON).
xRefer to the Connector Catalog for details on socket pin numbers
and lead wire colors.
Socket Tightening (Connector Type)
xTurn the socket connector screws by hand and tighten until no
space remains between the socket and the plug.
xMake sure that the socket connector is tightened securely.
Otherwise, the rated degree of protection (IP67) may not be
maintained and vibration may loosen the socket connector.
Conduit Opening
xConnect a recommended connector to the opening of the conduit
and tighten the connector to the specified torque. The case may be
damaged if an excessive tightening torque is applied.
xWhen using 1/2-14NPT, wind sealing tape around the joint
between the connector and conduit opening so that the enclosure
will conform to IP67.
xUse a cable with a suitable diameter for the connector.
xAttach and tighten a conduit cap to the unused conduit opening
when wiring. Tighten the conduit cap to the specified torque. The
conduit cap is provided with the Switch (2-conduit types).
Changing the Lever
The lever mounting screws can be used to set the lever position to
any position in a 360qangle at 7.5qincrements. Grooves are incised
on the lever and rotary shaft that engage to prevent the lever from
slipping against the rotary shaft. The screws on adjustable roller lever
models can also loosened to change the length of the lever.
Remove the screws from the front of the lever before mounting the
lever in reverse (front/back), and set the level so that operation will be
completed before exceeding a range of 180qon the horizontal.
Manufacturer Type
J.S.T. Mfg. Co. FN0.5-3.7 (F Type)
N0.5-3.7 (Straight Type)
2221
3433
12
11
A
A
C
E
B
DF
C
E
B
D
F28 mm
Tolerance ±2 mm
33 mm
42 mm
2221
3433
12
11
A
C
E
B
D
F
ACE
BDF
28 mm
Tolerance ±2 mm
Left hand
42 mm
ACE
BDF
28 mm
Tolerance ±2 mm
Right hand
42 mm
L
l F
B
D dia.
dz dia.
Correct Incorrect
Terminal screw
Crimp terminal
t: 0.5 mm
dz dia.: 3.7 mm
D dia.: 2.9 mm
B: 6.6 mm
L: 19 mm
F: 7.7 mm
I: 8.0 mm
14
32
13
31
D4N-@D@@ (3NC)
11
21
12
22
31 32
D4N-@B@@ (2NC)
D4N-@2@@ (2NC (SNAP))
11
31
12
32
D4N-@C@@ (2NC/1NO)
D4N-@F@@ (2NC/1NO (MBB))
D4N-@A@@ (1NC/1NO)
D4N-@E@@ (1NC/1NO (MBB))
33 34
11
21
12
22
11
33
12
34
D4N-@1@@ (1NC/1NO (SNAP))
14 (4)
32 (2)
(3) 13
(1) 31
1
3
24
Pin No. (Terminal No.)
D4N-9B@@ (2NC)
D4N-92@@ (2NC (SNAP))
D4N-9A@@ (1NC/1NO)
D4N-9E@@ (1NC/1NO (MBB))
(1) 11
(3) 31
12 (2)
32 (4)
(1) 11
(3) 33
12 (2)
34 (4)
D4N-91@@ (1NC/1NO (SNAP))
http://www.ia.omron.com/ 19
(c)Copyright OMRON Corporation 2007 All Rights Reserved.

D4N
Recommended Connectors
Use connectors with screws not exceeding 9 mm, otherwise the
screws will protrude into the case interior, interfering with other
components in the case.
The connectors listed in the following table have connectors with
thread sections not exceeding 9 mm.
Use the recommended connectors to ensure conformance to IP67.
Use LAPP connectors together with seal packing (JPK-16, GP-13.5,
or GPM20), and tighten to the specified tightening torque. Seal
packing is sold separately.
xLAPP is a German manufacturer.
xBefore using a 2-conduit 1/2-14NPT type, attach the provided
changing adaptor to the Switch and then connect the
recommended connector.
Others
xWhen attaching a cover, be sure that the seal rubber is in place and
that there is no foreign material present. If the cover is attached
with the seal rubber out of place or if foreign material is stuck to the
rubber, a proper seal will not be obtained.
xDo not use any screws to connect the cover other than the
specified ones. The seal characteristics may be reduced.
xMake sure that foreign particles do not enter the head when
removing the screws from the four corners to change the head
position in any of the four directions.
xUse the following recommended countermeasures to prevent
telegraphing when using adjustable or long levers.
1. Make the rear edge of the dog smooth with an angle of 15qto
30qor make it in the shape of a quadratic curve.
2. Design the circuit so that no error signal will be generated.
Size Manufacturer Model Applicable cable
diameter
G1/2 LAPP ST-PF1/2
5380-1002 6.0 to 12.0 mm
Pg13.5 LAPP ST-13.5
5301-5030 6.0 to 12.0 mm
M20 LAPP ST-M20 u1.5
5311-1020 7.0 to 13.0 mm
1/2-14NPT LAPP ST-NPT1/2
5301-6030 6.0 to 12.0 mm
http://www.ia.omron.com/ 20
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Other manuals for D4N Series
2
This manual suits for next models
646
Table of contents
Other Omron Switch manuals

Omron
Omron VX Series User manual

Omron
Omron A165K - User manual

Omron
Omron D4MC-5000 User manual

Omron
Omron Sti TL8012-S User manual

Omron
Omron D4F User manual

Omron
Omron D40A-G9SX-NS - User manual

Omron
Omron E3L-2 4 Series User manual

Omron
Omron D40Z User manual

Omron
Omron D4NL-1AFA-B User manual

Omron
Omron H2F - User manual