Omron D4N-R - User manual

G-267D4N-@R
D4N-
@
R
Miniature Manual Reset Limit Switch
D4N-@R
New Series of manual-reset
Limit Switch
• Lineup includes three contact models with 2NC/1NO and
3NC contacts in addition to the 1NC/ 1NO, and 2NC version.
Version with MBB contacts meet applications for avdanced
requirements.
• M12-connector models are available, saving on labor and
simplifying maintenance.
• Standardized gold-clad contacts provide high contact reli-
ability. Can be used with both standard loads and micro-
loads.
• Free of lead, cadmium, and hexavalent chrome, reducing the
burden on the environment.
• Conforms to EN115 and EN81-1.
Be sure to read the “Safety Precautions” on page G-277.
Note: Contact your sales representative for details on models with safety standard
certification.
Model Number Structure
1. Conduit/Connector size
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (M20 2-conduit with 1/2-14NPT changing adaptor
included)
8: M20 (2-conduit)
9: M12 connector (1-conduit)
2. Built-in Switch
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
3. Head and Actuator
20:Roller lever (resin lever, resin roller)
2G:Adjustable roller lever, form lock (metal lever, resin roller)
2H:Adjustable roller lever, form lock (metal lever. rubber roller)
31:Top plunger
32:Top roller plunger
62:One-way roller arm lever (horizontal)
72:One-way roller arm lever (vertical)
123
D4N-@@@@R
F502-EN2-04.book Seite 267 Dienstag, 26. Juli 2005 5:48 17

G-268 Safety Sensors / Components
Ordering Information
List of Models
Actuator Conduit size Built-in switch mechanism
1NC/1NO
(Slow-action) 2NC
(Slow-action) 2NC/1NO
(Slow-action) 3NC
(Slow-action)
Roller lever
(resin lever, resin roller) 1-conduit Pg13.5 D4N-1A20R D4N-1B20R D4N-1C20R D4N-1D20R
G1/2 D4N-2A20R D4N-2B20R D4N-2C20R D4N-2D20R
1/2-14NPT D4N-3A20R D4N-3B20R D4N-3C20R D4N-3D20R
M20 D4N-4A20R D4N-4B20R D4N-4C20R D4N-4D20R
M12 connector D4N-9A20R D4N-9B20R --- ---
2-conduit Pg13.5 D4N-5A20R D4N-5B20R D4N-5C20R D4N-5D20R
G1/2 D4N-6A20R D4N-6B20R D4N-6C20R D4N-6D20R
1/2-14NPT
(See note 2.) D4N-7A20R D4N-7B20R D4N-7C20R D4N-7D20R
M20 D4N-8A20R D4N-8B20R D4N-8C20R D4N-8D20R
Adjustable roller lever, form lock
(metal lever, resin roller) 1-conduit Pg13.5 D4N-1A2GR D4N-1B2GR D4N-1C2GR D4N-1D2GR
G1/2 D4N-2A2GR D4N-2B2GR D4N-2C2GR D4N-2D2GR
1/2-14NPT D4N-3A2GR D4N-3B2GR D4N-3C2GR D4N-3D2GR
M20 D4N-4A2GR D4N-4B2GR D4N-4C2GR D4N-4D2GR
M12 connector D4N-9A2GR D4N-9B2GR --- ---
2-conduit Pg13.5 D4N-5A2GR D4N-5B2GR D4N-5C2GR D4N-5D2GR
G1/2 D4N-6A2GR D4N-6B2GR D4N-6C2GR D4N-6D2GR
1/2-14NPT
(See note 2.) D4N-7A2GR D4N-7B2GR D4N-7C2GR D4N-7D2GR
M20 D4N-8A2GR D4N-8B2GR D4N-8C2GR D4N-8D2GR
Adjustable roller lever, form lock
(metal lever, rubber roller) 1-conduit Pg13.5 D4N-1A2HR D4N-1B2HR D4N-1C2HR D4N-1D2HR
G1/2 D4N-2A2HR D4N-2B2HR D4N-2C2HR D4N-2D2HR
1/2-14NPT D4N-3A2HR D4N-3B2HR D4N-3C2HR D4N-3D2HR
M20 D4N-4A2HR D4N-4B2HR D4N-4C2HR D4N-4D2HR
M12 connector D4N-9A2HR D4N-9B2HR --- ---
2-conduit Pg13.5 D4N-5A2HR D4N-5B2HR D4N-5C2HR D4N-5D2HR
G1/2 D4N-6A2HR D4N-6B2HR D4N-6C2HR D4N-6D2HR
1/2-14NPT
(See note 2.) D4N-7A2HR D4N-7B2HR D4N-7C2HR D4N-7D2HR
M20 D4N-8A2HR D4N-8B2HR D4N-8C2HR D4N-8D2HR
Plunger 1-conduit Pg13.5 D4N-1A31R D4N-1B31R D4N-1C31R D4N-1D31R
G1/2 D4N-2A31R D4N-2B31R D4N-2C31R D4N-2D31R
1/2-14NPT D4N-3A31R D4N-3B31R D4N-3C31R D4N-3D31R
M20 D4N-4A31R D4N-4B31R D4N-4C31R D4N-4D31R
M12 connector D4N-9A31R D4N-9B31R --- ---
2-conduit Pg13.5 D4N-5A31R D4N-5B31R D4N-5C31R D4N-5D31R
G1/2 D4N-6A31R D4N-6B31R D4N-6C31R D4N-6D31R
1/2-14NPT
(See note 2.) D4N-7A31R D4N-7B31R D4N-7C31R D4N-7D31R
M20 D4N-8A31R D4N-8B31R D4N-8C31R D4N-8D31R
Roller plunger 1-conduit Pg13.5 D4N-1A32R D4N-1B32R D4N-1C32R D4N-1D32R
G1/2 D4N-2A32R D4N-2B32R D4N-2C32R D4N-2D32R
1/2-14NPT D4N-3A32R D4N-3B32R D4N-3C32R D4N-3D32R
M20 D4N-4A32R D4N-4B32R D4N-4C32R D4N-4D32R
M12 connector D4N-9A32R D4N-9B32R --- ---
2-conduit Pg13.5 D4N-5A32R D4N-5B32R D4N-5C32R D4N-5D32R
G1/2 D4N-6A32R D4N-6B32R D4N-6C32R D4N-6D32R
1/2-14NPT
(See note 2.) D4N-7A32R D4N-7B32R D4N-7C32R D4N-7D32R
M20 D4N-8A32R D4N-8B32R D4N-8C32R D4N-8D32R
Prefered types
F502-EN2-04.book Seite 268 Dienstag, 26. Juli 2005 5:48 17

G-269D4N-@R
D4N-
@
R
Note: 1. It is recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North
American countries.
2. The 1/2-14NPT 2-conduit models include an M20-to-1/2-14NPT changing adaptor.
Specifications
Standards and EC Directives
•Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN1088
GS-ET-15
Approved Standards
Note: Approval for CSA C22.2 No. 14 is authorized by the UL mark.
CCC (China Compulsory Certification) Mark
Approved Standard Ratings
TÜV (EN60947-5-1)
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
protection device. This fuse is not built into the Switch.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Q300
One-way roller arm lever
(horizontal) 1-conduit Pg13.5 D4N-1A62R D4N-1B62R D4N-1C62R D4N-1D62R
G1/2 D4N-2A62R D4N-2B62R D4N-2C62R D4N-2D62R
1/2-14NPT D4N-3A62R D4N-3B62R D4N-3C62R D4N-3D62R
M20 D4N-4A62R D4N-4B62R D4N-4C62R D4N-4D62R
M12 connector D4N-9A62R D4N-9B62R --- ---
2-conduit Pg13.5 D4N-5A62R D4N-5B62R D4N-5C62R D4N-5D62R
G1/2 D4N-6A62R D4N-6B62R D4N-6C62R D4N-6D62R
1/2-14NPT
(See note 2.) D4N-7A62R D4N-7B62R D4N-7C62R D4N-7D62R
M20 D4N-8A62R D4N-8B62R D4N-8C62R D4N-8D62R
One-way roller arm lever (vertical) 1-conduit Pg13.5 D4N-1A72R D4N-1B72R D4N-1C72R D4N-1D72R
G1/2 D4N-2A72R D4N-2B72R D4N-2C72R D4N-2D72R
1/2-14NPT D4N-3A72R D4N-3B72R D4N-3C72R D4N-3D72R
M20 D4N-4A72R D4N-4B72R D4N-4C72R D4N-4D72R
M12 connector D4N-9A72R D4N-9B72R --- ---
2-conduit Pg13.5 D4N-5A72R D4N-5B72R D4N-5C72R D4N-5D72R
G1/2 D4N-6A72R D4N-6B72R D4N-6C72R D4N-6D72R
1/2-14NPT
(See note 2.) D4N-7A72R D4N-7B72R D4N-7C72R D4N-7D72R
M20 D4N-8A72R D4N-8B72R D4N-8C72R D4N-8D72R
Actuator Conduit size Built-in switch mechanism
1NC/1NO
(Slow-action) 2NC
(Slow-action) 2NC/1NO
(Slow-action) 3NC
(Slow-action)
Agency Standard File No.
TÜV Product
Service EN60947-5-1 (approved
direct opening) B03 11 39656 061
UL (See note.) UL508, CSA C22.2 No.14 E76675
Agency Standard File No.
CQC GB14048.5 Under application
Item Utilization
category AC-15 DC-13
Rated operating current (Ie)3 A 0.27 A
Rated operating voltage (Ue)240 V 250 V
Rated
voltage Carry current Current Volt-amperes
Make Break Make Break
120 VAC 10 A 60 A 6 A 7,200 VA 720 VA
240 VAC 30 A 3 A
Rated
voltage Carry current Current Volt-amperes
Make Break Make Break
125 VDC 2.5 A 0.55 A 0.55 A 69 VA 69 VA
250 VDC 0.27 A 0.27 A
F502-EN2-04.book Seite 269 Dienstag, 26. Juli 2005 5:48 17

G-270 Safety Sensors / Components
Characteristics
Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in rough-
ening of the contact surface and contact reliability may be lost.
3. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do
not use the D4N-@R in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Other-
wise, premature wear, Switch damage or malfunctioning may occur.
4. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
5. If the ambient temperature is greater than 35°C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the ac-
tual load beforehand.
Degree of protection (See note 3.) IP67 (EN60947-5-1)
Durability
(See note 4.) Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. for a resistive load of 3 A at 250 VAC (See note 5.)
300,000 operations min. for a resistive load of 10 A at 250 VAC
Operating speed 1 mm/s to 0.5 m/s (D4N-1A20R)
Operating frequency 30 operations/minute max.
Contact resistance 25 mΩmax.
Minimum applicable load (See note 6.) Resistive load of 1 mA at 5 VDC (N-level reference value)
Rated insulation voltage (Ui)300 V
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) Level 3 (EN60947-5-1)
Impulse withstand voltage (EN60947-5-1) Between terminals of the same polarity: 2.5 kV
Between terminals of different polarities: 4 kV
Between other terminals and uncharged metallic parts: 6 kV
Insulation resistance 100 MΩmin.
Contact gap Snap-action: 2 x 0.5 mm min
Slow-action: 2 x 2 mm min
Vibration resistance Malfunction 10 to 55 Hz, 0.75-mm single amplitude
Shock resistance Destruction 1,000 m/s2
Malfunction 300 m/s2
Conditional short-circuit current 100 A (EN60947-5-1)
Rated open thermal current (Ith)10 A (EN60947-5-1)
Ambient temperature Operating: −30°C to 70°C with no icing
Ambient humidity Operating: 95% max.
Weight Approx. 92 g (D4N-1A20R)
F502-EN2-04.book Seite 270 Dienstag, 26. Juli 2005 5:48 17

D4N-
@
R
G-271D4N-@R
Structure, Names, and Functions
Structure
Contact Form
Model Contact Contact form Operating pattern Remarks
D4N-@A@R 1NC/1NO
D4N-@B@R2NC
D4N-@C@R 2NC/1NO
D4N-@D@R3NC
Size Box
Pg13.5
G1/2
1/2-14NPT
M20
M12 connector
1-conduit model
Yes
Yes
Yes
Yes
Yes
2-conduit model
Yes
Yes
Yes
Yes
---
Note: M12 connector types are not available for
Switches with three contacts.
Head
Safety-oriented Lever Setting
Cover
Built-in Switch
Conduit
Reset Head (Blue)
With roller lever models, the direction of the
switch head can be adjusted to any of the four
directions by loosening the roller lever switch
screws at the four corners of the head.
A wide variety of conduits is available.
Grooves which engage the lever are cut in the lever and
rotary shaft to prevent the lever from slipping against the
rotary shaft. The actuator locks (self-holding) when it
moves to the lock position.
The direction of the reset head can be adjusted to any of
the four directions.
The built-in switch has a direct opening mechanism that
forcibly separates the NC contact even when there is
contact deposit.
The cover, with a hinge on its lower part, can be opened
by removing the screw of the cover, which ensures ease
of maintenance and wiring.
11
33
12
34
Zb
ON
Stroke
11-12
33-34
Only NC contacts 11-12 have an
approved direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
11
31
12
32
Zb
ON
Stroke
11-12
31-32
Only NC contacts 11-12 and
31-32 have an approved
direct opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
33 34
11
21
12
22
Zb
ON
Stroke
21-22
33-34
11-12
Only NC contacts 11-12 and
21-22 have an approved
direct opening mechanism.
The terminals 11-12, 21-22, and
33-34 can be used as unlike
poles.
11
21
12
22
31 32
Zb
ON
Stroke
11-12
21-22
31-32
Only NC contacts 11-12, 21-22,
and 31-32 have an approved di-
rect opening mechanism.
The terminals 11-12, 21-22, and
31-32 can be used as unlike
poles.
F502-EN2-04.book Seite 271 Dienstag, 26. Juli 2005 5:48 17

G-272 Safety Sensors / Components
Direct Opening Mechanism
1NC/1NO Contact (Slow-action)
2NC Contact (Slow-action)
Contact spring
Return spring
Fixed contact (NC)
Fixed contact (NO)
Plunger
Movable contacts
Only the NC contact side has a direct opening
mechanism.
When metal deposition occurs, the contacts are
separated from each other by the plunger being
pushed in.
(Conforms to EN60947-5-1 Direct Opening Operation.)
Contact spring
Return spring
Fixed contact (NC)
Plunger
Movable contact
Both NC contacts have a direct opening mechanism.
When metal deposition occurs, the contacts are
separated from each other by the plunger being
pushed in.
(Conforms to EN60947-5-1 Direct Opening Operation.)
F502-EN2-04.book Seite 272 Dienstag, 26. Juli 2005 5:48 17

G-273D4N-@R
D4N-
@
R
Dimensions
Switches
Note: All units are in millimeters unless otherwise indicated.
1-conduit Models
1-conduit M12 Connectors
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies
to all dimensions.
2. Variation occurs in the simultaneity of contact opening/clos-
ing operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
3. There are a minimum of five turns of the screw thread for a
Pg13.5 conduit opening and four turns minimum for a G 1/2
conduit opening.
4. Refer to the following diagram for details on M12 connec-
tors.
Note: 1. Variation occurs in the simultaneity of contact opening/clos-
ing operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
2. The operating characteristics of these Switches were mea-
sured with the roller lever set at 32 mm.
3. These PT values are possible when the NC contacts are
open (OFF).
4. These PT values are nominal values possible when the NO
contacts are closed (ON). (1NC/1NO models only)
5. Nominal value.
6. Load and stroke values for the direct opening mechanism.
For safe use, always make sure that the minimum values or
greater are provided.
Roller Lever (Resin Lever, Resin Roller)
D4N-1@20R D4N-2@20R
D4N-3@20R D4N-4@20R
D4N-9@20R (See note 4.)17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
Resin lever
2.15±0.05R
mounting
holes
Conduit cap
(See note 3.)
20.5 ×20.5
Blue
22±0.2
31 max.
55
47±0.2
2.5
34
9±0.2 16.7
20±0.1
22±0.1
26R
14 dia.
43.5
11±0.2
47±1
40±1
(27)
21.5
30
36
14.2
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
D4N-1@2GR D4N-2@2GR
D4N-3@2GR D4N-4@2GR
D4N-9@2GR (See note 4.)
17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia.
holes
Depth: 5
0
20 to 66R
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
20.5 ×20.5
Blue
30
14.2
43.5
11±0.2
45±1
39.5±1
(31)
21.5
14 dia.
16.7
22±0.2
31 max.
55
47±0.2
2.5
34
9±0.2
20±0.1
22±0.1
25
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
D4N-1@2HR D4N-2@2HR
D4N-3@2HR D4N-4@2HR
D4N-9@2HR (See note 4.)
50 dia. ×8
rubber roller
Resin bearing
Stainless steel
lever
Two, 4+0.15 dia. holes
Depth: 5
0
20.5×20.5
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
22±0.2
31 max.
55
47±0.2
2.5
34
9±0.2
20±0.1
22±0.1
25
30
14.2
43.5
11±0.2
48.2±1
41.3±1
(29.2)
21.5
14 dia.
16.7
32 to 66R
(P:2)
D4N-9@@@R
(14)
M12 ×1
14.2
30
Model D4N-@@20R D4N-@@2GR
(See note 2.) D4N-@@2HR
LF max. 6.4N5.6N5.4N
LT max. 55°55°55°
PT 1
(See note 3.) 18 to 27°18 to 27°18 to 27°
(PT 2)
(See note 4.) (44°)(44°)(44°)
(TT)
(See note 5.) 80°80°80°
DOF min.
(See note 6.) 20 N 20 N 20 N
DOT min.
(See note 6.) 50°50°50°
F502-EN2-04.book Seite 273 Dienstag, 26. Juli 2005 5:48 17

G-274 Safety Sensors / Components
1-conduit Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Variation occurs in the simultaneity of contact opening/closing operations of 2NC and 3NC contacts. Check contact operation.
3. There are a minimum of five turns of the screw thread for a Pg13.5 conduit opening and four turns minimum for a G 1/2 conduit opening.
4. Refer to page 273 for details on M12 connectors.
Note: 1. Variation occurs in the simultaneity of contact opening/clos-
ing operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
2. These PT values are possible when the NC contacts are
open (OFF).
3. These PT values are nominal values possible when the NO
contacts are closed (ON). (1NC/1NO models only)
4. Nominal value.
5. Load and stroke values for the direct opening mechanism.
For safe use, always make sure that the minimum values or
greater are provided.
Plunger
D4N-1@31R D4N-2@31R
D4N-3@31R D4N-4@31R
D4N-9@31R (See note 4.)
Two, 4
+0.15
dia.
holes
Depth: 5
0
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
20.5 ×20.5
6 dia. 11
±0.2
22
±0.2
31 max.
55
47
±0.2
2.5
OP (27)
9
±0.2
16.7
20
±0.1
22
±0.1
14 dia.
21.5
30
36
14.2
Roller Plunger
D4N-1@32R D4N-2@32R
D4N-3@32R D4N-4@32R
D4N-9@32R (See note 4.)
9.5 dia. ×5
resin roller
Two, 4
+0.15
dia.
holes
Depth: 5
0
20.5 ×20.5
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
22±0.2
31 max.
55
47±0.2
2.5
OP 41
9±0.2 16.7
20±0.1
22±0.1
14 dia.
11±0.2
21.5
30
36
14.2
Two, 4
+0.15
dia.
holes
Depth: 5
0
One-way Roller Arm Lever
(Horizontal)
D4N-1@62R D4N-2@62R
D4N-3@62R D4N-4@62R
D4N-9@62R (See note 4.)
12 dia. ×5
resin roller
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
11
±0.2
21.5
30
36
14.2
10.2
14.8
22
±0.2
31 max.
55
47
±0.2
2.5
OP
9
±0.2
16.7
20
±0.1
22
±0.1
14 dia.
11
±0.2
35.5
±0.2
20R
39.3
13.5
Operating
direction
Two, 4
+0.15 dia.
holes
Depth: 5
0
One-way Roller Arm Lever
(Vertical)
D4N-1@72R D4N-2@72R
D4N-3@72R D4N-4@72R
D4N-9@7R2 (See note 4.)
Operating
direction
12 dia. ×5
resin roller
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
11
± 0.2
21.5
30
36
14.2
10.2
22
±0.2
31 max.
55
47
±0.2
35.5
±0.2
2.5
9
±0.2
14.7
20
±0.1
22
±0.1
14 dia.
11
±0.2
R19
16.7
12
OP
Model D4N-
@@31R D4N-
@@32R D4N-
@@62R D4N-
@@72R
LF max. 10.8 N 10.8N 7.5 N 7.9 N
LT max. 4.5 mm 4.5 mm 7 mm 7 mm
PT 1
(See note 2.) 2 mm 2 mm 4 mm 4 mm
(PT 2)
(See note 3.) (2.9 mm) (2.9 mm) (5.2 mm) (4.3 mm)
OP 34 ±0.5 mm 44.4
±0.8 mm 53 ±0.8 mm 27 ±0.8 mm
(TT)
(See note 4.) (6 mm) (6 mm) (9 mm) (9 mm)
DOF min.
(See note 5.) 20 N 20 N 20 N 20 N
DOT min.
(See note 5.) 3.2 mm 3.2 mm 5.8 mm 4.8 mm
F502-EN2-04.book Seite 274 Dienstag, 26. Juli 2005 5:48 17

G-275D4N-@R
D4N-
@
R
2-conduits Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Variation occurs in the simultaneity of contact opening/closing operations of 2NC and 3NC contacts. Check contact operation.
3. There are a minimum of five turns of the screw thread for a Pg13.5 conduit opening and four turns minimum for a G 1/2 conduit opening.
Note: 1. Variation occurs in the simultaneity of contact opening/clos-
ing operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
2. These PT values are possible when the NC contacts are
open (OFF).
3. These PT values are nominal values possible when the NO
contacts are closed (ON). (1NC/1NO models only)
4. Nominal value.
5. Load and stroke values for the direct opening mechanism.
For safe use, always make sure that the minimum values or
greater are provided.
Roller Lever (Resin Lever, Resin Roller)
D4N-5@20R D4N-6@20R
D4N-7@20R D4N-8@20R
17.5 dia. ×6.8
resin roller
Two, 4+0.15 dia. holes
Depth: 5
0
Cap
20.5 ×20.5
Resin lever
2.15±0.05R
mounting
holes
Conduit cap
(See note 3.)
Blue
43.5
20.5
11±0.2
47±1
40±1
(27)
21.5
30
36
14.2
16.7
14 dia.
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
2.5
5.4
9±0.2
26R
34
20±0.1
40±0.1
42±0.1
22±0.1
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
D4N-5@2GR D4N-6@2GR
D4N-7@2GR D4N-8@2GR
17.5 dia. ×6.8
resin roller
Two, 4
+0.15
dia. holes
Depth: 5
0
Cap
20 to 66R
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
20.5 ×20.5
Blue
30
14.2
43.5
11±0.2
45±1
39.5±1
(31)
14 dia.
16.7
20.5
21.5
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
2.5
5.4
9±0.2
34
20
±
0.1
40
±
0.1
42
±
0.1
22
±
0.1
25
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
D4N-5@2HR D4N-6@2HR
D4N-7@2HR D4N-8@2HR
50 dia. ×8
rubber roller
Resin bearing
Stainless
steel lever
Two, 4+0.15 dia. holes
Depth: 5
0
20.5 ×20.5
Cap
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
30
14.2
43.5
11
±0.2
48.2
±1
41.3
±1
(29.2)
14 dia.
16.7
20.5
21.5
25
42
±0.2
(3)
56 max.
47
39
±0.2
25 dia.
2.5
5.4
9
±0.2
34
20
±0.1
40
±0.1
42
±0.1
22
±0.1
32 to 66R
(P:2)
Model D4N-@@20R D4N-@@2GR D4N-@@2HR
LF max. 6.4 N 5.6 N 5.4 N
LT max. 55°55°55°
PT 1
(See note 2.) 18°to 27°18°to 27°18°to 27°
(PT 2)
(See note 3.) (44°)(44°)(44°)
(TT)
(See note 4.) 80°80°80°
DOF min.
(See note 5.) 20 N 20 N 20 N
DOT min.
(See note 5.) 50°50°50°
F502-EN2-04.book Seite 275 Dienstag, 26. Juli 2005 5:48 17

G-276 Safety Sensors / Components
2-conduits Models
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. Variation occurs in the simultaneity of contact opening/closing operations of 2NC and 3NC contacts. Check contact operation.
3. There are a minimum of five turns of the screw thread for a Pg13.5 conduit opening and four turns minimum for a G 1/2 conduit opening.
Note: 1. Variation occurs in the simultaneity of contact opening/clos-
ing operations of 2NC, 2NC/1NO, and 3NC contacts. Check
contact operation.
2. These PT values are possible when the NC contacts are
open (OFF).
3. These PT values are nominal values possible when the NO
contacts are closed (ON). (1NC/1NO models only)
4. Nominal value.
5. Load and stroke values for the direct opening mechanism.
For safe use, always make sure that the minimum values or
greater are provided.
Plunger
D4N-5@31R
D4N-6@31R
D4N-7@31R
D4N-8@31R
Two, 4
+0.15
dia. holes
Depth: 5
0
Cap
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
11±0.2
21.5
30
36
14.2
20.5
16.7
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
2.5
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
20.5 ×20.5
6 dia.
5.4
OP
14 dia.
(27)
Roller Plunger
D4N-5@32R D4N-6@32R
D4N-7@32R D4N-8@32R
9.5 dia. ×5
resin roller
Two, 4
+0.15
dia. holes
Depth: 5
0
Cap
20.5 ×20.5
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
11±0.2
21.5
30
36
14.2
20.5
5.4
OP 41
14 dia.
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
2.5
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
16.7
Two, 4+0.15 dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Horizontal)
D4N-5@62R D4N-6@62R
D4N-7@62R D4N-8@62R
12 dia. x 5
resin roller
2.15±0.05R
mounting holes
Cap
Operating direction
Conduit cap
(See note 3.)
Blue
11±0.2
21.5
30
36
14.2
10.2
20.5
14.8
5.4
OP 14 dia.
11±0.2
35.5±0.2
20R
39.3
13.5
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
2.5
Two, 4
+0.15
dia. holes
Depth: 5
0
One-way Roller Arm Lever
(Vertical)
D4N-5@72R D4N-6@72R
D4N-7@72R D4N-8@72R
Operating
direction
12 dia. ×5
resin roller
Cap
2.15±0.05R
mounting holes
Conduit cap
(See note 3.)
Blue
11±0.2
21.5
30
36
14.2
10.2
20.5
35.5±0.2
14.7
14 dia.
11±0.2
19R
16.7
12
OP
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
2.5
5.4
9±0.2
20±0.1
40±0.1
42±0.1
22±0.1
Model D4N-@@31R D4N-@@32R D4N-@@62R D4N-@@72R
LF max. 10.8 N 10.8N 7.5 N 7.9 N
LT max. 4.5 mm 4.5 mm 7 mm 7 mm
PT 1 max.
(See note 2.) 2 mm 2 mm 4 mm 4 mm
(PT 2)
(See note 3.) (2.9 mm) (2.9 mm) (5.2 mm) (4.3 mm)
OP 34 ±0.5 mm 44.4 ±0.8 mm 53 ±0.8 mm 27 ±0.8 mm
(TT)
(See note 4.) (6 mm) (6 mm) (9 mm) (9 mm)
DOF min.
(See note 5.) 20 N 20 N 20 N 20 N
DOT min.
(See note 5.) 3.2 mm 3.2 mm 5.8 mm 4.8 mm
F502-EN2-04.book Seite 276 Dienstag, 26. Juli 2005 5:48 17

G-277D4N-@R
D4N-
@
R
Levers
Refer to the following diagrams for the angles and positions of the dogs.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Safety Precautions
Refer to OMRON SAFETY COMPONENTS SERIES (Y106) for
common precautions for Switches and Safety Limit Switches.
Do not use metal connectors or metal conduits with this Switch.
Doing so may occasionally result in electric shock.
Precautions for Safe Use
•Do not drop the
Switch
. Doing so may result in the
Switch
not
performing to its full capacity.
•Do not attempt to disassemble or modify the
Switch
. Doing so may
cause the
Switch
to malfunction.
•Do not use the
Switch
where explosive gas, flammable gas, or any
other hazardous gas may be present.
•Install the Switch in a location away from close body contact. Not
doing so may result in malfunction.
•
Do not use the Switch submerged in oil or water, or in locations
continuously subject to splashes of oil or water. Doing so may result
in oil or water entering the Switch interior. (The IP67 degree of
protection specification for the Switch refers to water penetration
while the Switch is submersed in water for a specified period of
time.)
•Protect the head from foreign material. Subjecting the head to
foreign material may result in premature wear or damage to the
Switch. Although the switch body is protected from penetration by
dust or water, the head is not protected from penetration by minute
particles or water.
•Turn the power OFF before wiring. Doing so may result in electric
shock.
•Install the cover after wiring. Not doing so may result in electric
shock.
•Connect a fuse to the Switch in series to protect the Switch from
short-circuit damage. Use a fuse with a breaking current 1.5 to 2
times larger than the rated current. To conform to EN ratings, use
an IEC60269-compliant 10-A fuse type gI or gG.
•Do not switch circuits for two or more standard loads (250 VAC,
3 A) at the same time. Doing so may adversely affect insulation
performance.
•The durability of the Switch is greatly affected by operating
conditions. Evaluate the Switch under actual working conditions,
before permanent installation and use within a number of switching
operations that will not adversely affect the Switch’s performance.
•Be sure to indicate in the machine manufacturer’s instruction
manual that the user must not attempt to repair or maintain the
Switch and must contact the machine manufacturer for any repairs
or maintenance.
Roller Lever
(D4N-@@20R)
Adjustable Roller Lever, Form Lock
(with Metal Lever, Resin Roller)
(D4N-@@2GR)
Adjustable Roller Lever, Form Lock
(with Metal Lever, Rubber Roller)
(D4N-@@2HR)
40±2
56+1
0
20 min.
Dog
10 min.
Dog
5 min.
40±2
30°
30°
71+1
0
51+1
0
40 min.
Dog
15 min.
10 min.
42±2
30°
86+1
0
71+1
0
45 min.
25 min.
10 min.
50
R65 R20
R65 R31
30°
Sealed Plunger
(D4N-@@31R)
Roller Plunger
(D4N-@@32R)
12.5
0
−2.5
Dog
31 min.
Dog
41
+1
0
30°
12.5
0
−2.5
Dog
20 min.
10 min. 41 min.
2.5
Dog
One-way Roller Arm Lever
(Horizontal)
(D4N-@@62R)
One-way Roller Arm Lever
(Vertical)
(D4N-@@72R)
30 max.
Dog
20 min.
47
+1
0
5 min.
10 min.
30°
12.5
0
−2.5
30°
20 min.
22
+1
0
5 min.
10 min.
12.5
0
−2.5
Dog
CAUTION
F502-EN2-04.book Seite 277 Dienstag, 26. Juli 2005 5:48 17

G-278 Safety Sensors / Components
•If the Switch is to be used in an emergency stop circuit or in a
safety circuit for preventing accidents resulting in injuries or deaths,
use a model that has an NC contact equipped with a direct opening
mechanism and make sure that the Switch operates in the direct
opening mode. Furthermore, secure the Switch with screws or
equivalent parts that are tightened in a single direction so that the
Switch cannot be easily removed. Then provide a protection cover
for the Switch and post a warning label near the Switch.
•Make sure that the actuator is pushed into the lock position. Not
doing so may result in the actuator becoming unlocked, causing an
accident.
•Always reset the Switch manually. Not doing so may result in
damage to the reset function.
•When the Switch locks due to a fault in the system, be sure to reset
the Switch manually before resupplying power after confirming the
safety of the system.
•Check the Switches before use and inspect regularly, replacing
them when necessary. If a Switch is kept pressed for an extended
period of time, the components may deteriorate quickly, and the
Switch may not release.
•When using the Switch as a safety component, be sure to check
the system design for both operational and circuit safety.
Precautions for Correct Use
Environment
•The Switch is intended for indoor use only.
•Do not use the Switch outdoors. Doing so may cause the Switch to
malfunction.
•Do not use the Switch where hazardous gases (e.g., H2S, SO2,
NH3, HNO3, CI2) are present or in locations subject to high
temperature and humidity. Doing so may result in damage to the
Switch caused by contact failure or corrosion.
•Do not use the Switch under any of the following conditions.
•Locations subject to extreme temperature changes.
•Locations where high humidity or condensation may occur.
•Locations subject to excessive vibration.
•Locations where metal dust, processing waste, oil, or chemicals
may penetrate through the protective door.
•Locations subject to detergents, thinner, or other solvents.
Mounting Method
Mounting Screw Tightening Torque
Tighten each of the screws to the specified torque. Loose screws
may result in malfunction of the Switch within a short time.
Switch Mounting
•Mount the Switch using M4 screws and washers and tighten the
screws to the specified torque.
•For safety, use screws that cannot be easily removed, or use an
equivalent measure to ensure that the Switch is secure.
•Secure the Switch with two M4 bolts and washers. Provide studs
with a diameter of 4 0.05/0.15 and a height of 4.8 mm max. at two
places, inserting into the holes at the bottom of the Switch as
shown below so that the Switch is firmly fixed at four points.
Switch Mounting Holes
One-conduit Type
Two-conduit Type
Changing the Head Direction
By removing the four screws of the head, the mounting direction of
the head can be changed. The head can be mounted in four direc-
tions. Be sure that no foreign material will enter the head during a
change in direction.
Wiring
•When connecting to the terminals via insulating tube and M3.5
crimp terminals, arrange the crimp terminals as shown below so
that they do not rise up onto the case or the cover. Applicable lead
wire size: AWG20 to AWG18 (0.5 to 0.75 mm2).
Use lead wires of an appropriate length, as shown below. Not doing
so may result in excess length causing the cover to rise and not fit
properly.
One-conduit Type (3 Poles)
Two-conduit Type (3 Poles)
1 Terminal screw 0.6 to 0.8 N·m
2 Cover clamping screw 0.5 to 0.7 N·m
3 Head clamping screw 0.5 to 0.6 N·m
4 Lever clamping screw 1.6 to 1.8 N·m
5 Body clamping screw 0.5 to 0.7 N·m
6 Conduit mounting connection,
M12 adaptor 1.8 to 2.2 N·m (except 1/2-
14NPT)
1.4 to 1.8 N·m (1/2-14NPT)
7 Cap screw 1.3 to 1.7 N·m
7
6
3
4
5
1
2
22±0.1
47±0.1
20±0.1
22±0.1
2.5±0.1 Two, M4
−0.15
4−0.05 dia.
height, 4.8 max.
Mounting hole
Mounting surface
Mounting pin
insertion hole
−0.15
4−0.05 dia.
height, 4.8 max.
42±0.1
39±0.1
20±0.1
22±0.1
40±0.1
42±0.1
2.5±0.1
5.35±0.1
Two, M4
−0.15
4
−0.05
dia.
hei
g
ht, 4.8 max.
2221
3433
1211
A
A
C
E
B
DF
C
E
B
D
F28 mm
Tolerance ±2 mm
33 mm
42 mm
2221
3433
1211
A
C
E
B
D
F
ACE
BDF
28 mm
Tolerance ±2 mm
Left hand
42 mm
ACE
BDF
28 mm
Tolerance ±2 mm
Right hand
42 mm
F502-EN2-04.book Seite 278 Dienstag, 26. Juli 2005 5:48 17

G-279D4N-@R
D4N-
@
R
•Do not push crimp terminals into gaps in the case interior. Doing so
may cause damage or deformation of the case.
•Use crimp terminals not more than 0.5 mm in thickness. Otherwise,
they will interfere with other components inside the case. The crimp
terminals shown below are not more than 0.5 mm thick.
J.S.T is a Japanese manufacturer.
Contact Arrangement
•The following diagrams show the contact arrangements used for
screw terminal types and connector types.
Screw Terminal Type
Connector Type
•Applicable socket: XS2F (OMRON).
•Refer to the G010 Connector Catalog for details on socket pin num-
bers and lead wire colors.
Socket Tightening (Connector Type)
•Turn the socket connector screws by hand and tighten until no
space remains between the socket and the plug.
•Make sure that the socket connector is tightened securely. Other-
wise, the rated degree of protection (IP67) may not be maintained
and vibration may loosen the socket connector.
Conduit Opening
•Connect a recommended connector to the opening of the conduit
and tighten the connector to the specified torque. The case may be
damaged if an excessive tightening torque is applied.
•When using 1/2-14NPT, wind sealing tape around the joint between
the connector and conduit opening so that the enclosure will con-
form to IP67.
•Use a cable with a suitable diameter for the connector.
•Attach and tighten a conduit cap to the unused conduit opening
when wiring. Tighten the conduit cap to the specified torque. The
conduit cap is provided with the Switch (2-conduit types).
Recommended Connectors
Use connectors with screws not exceeding 9 mm, otherwise the
screws will protrude into the case interior, interfering with other
components in the case. The connectors listed in the following table
have connectors with thread sections not exceeding 9 mm. Use the
recommended connectors to ensure conformance to IP67.
Use LAPP connectors together with seal packing (JPK-16, GP-13.5,
GPM20, or GPM12), and tighten to the specified tightening torque.
Seal packing is sold separately.
LAPP is a German manufacturer. Ohm Denki is a Japanese
manufacturer.
Before using an M12 type, attaching the provided changing adaptor
to the Switch and then connect the recommended connector.
Before using a 2-conduit 1/2-14NPT type, attach the provided
changing adaptor to the Switch and then connect the recommended
connector.
Storage
Do not store the Switch in locations where hazardous gases (e.g.,
H2S, SO2, NH3, HNO3, Cl2) or dust is present, or in locations subject
to high temperatures and humidity.
Others
•Do not allow the load current to exceed the rated value.
•Confirm that the seal rubber has no defects before use.
If the seal rubber is displaced or raised, or has foreign particles
adhered to it, the sealing capability of the seal rubber will be
adversely affected.
•Use the correct cover mounting screws only, or the sealing
capability of the seal rubber will deteriorate.
•Inspect the Switch regularly.
•With rubber roller lever models, the rubber roller may turn white
over time, but this will not affect the quality of operation.
•Use the following recommended countermeasures to prevent
telegraphing when using adjustable or long levers.
1. Make the rear edge of the dog smooth with an angle of 15°to 30°
or make it in the shape of a quadratic curve.
2. Design the circuit so that no error signal will be generated.
3. Use or set a Switch that is operated in one direction only.
Manufacture Type Wire size
J.S.T. FV0.5-3.7 (F type)
V0.5-3.7 (straight type)
AWG20 (0.5 mm2)
L
l F
B
L
l F
B
D dia.
Correct Incorrect
Terminal scre
w
Crimp terminal
t: 0.5 mm
dz dia.: 3.7 mm
D dia.: 2.9 mm
B: 6.6 mm
L: 19 mm
F: 7.7 mm
I: 8.0 mm
dz dia.
D4N-@D@@R (3NC)
11
21
12
22
31 32
D4N-@B@@R (2NC)
11
31
12
32
D4N-@C@@R (2NC/1NO)
D4N-@A@@R (1NC/1NO)
33 34
11
21
12
22
11
33
12
34
1
3
2 4
D4N-9B@@R (2NC)
(1) 11
(3) 31
12 (2)
32 (4)
D4N-9A@@R (1NC/1NO)
(1) 11
(3) 33
Pin No. (Terminal No.) 12 (2)
34 (4)
Size Manufacturer Model Applicable cable
diameter
G1/2 LAPP ST-PF1/2
5380-1002 6.0 to 12.0 mm
Ohm Denki OA-W1609 7.0 to 9.0 mm
OA-W1611 9.0 to 11.0 mm
Pg13.5 LAPP S-13.5
5301-5030 6.0 to 12.0 mm
M20 LAPP ST-M20 ×1.5
5311-1020 7.0 to 13.0 mm
1/2-14NPT LAPP ST-NPT1/2
5301-6030 6.0 to 12.0 mm
M12 LAPP ST-M12 ×1.5
5301-1000 3.5 to 7.0 mm
F502-EN2-04.book Seite 279 Dienstag, 26. Juli 2005 5:48 17

G-280 Safety Sensors / Components
Production Termination
Following the release of the D4N-R, production of the D4D-R will be
terminated.
Date of Production Termination
Production of the D4D-R Series will be terminated in March 2006.
Product Replacement
1. Dimensions
The D4D-R and D4N-R use the same mounting method, and
mounting hole. The multi-contact structure and the extra 4 mm in
length, however, are different.
2. Terminal Numbers
For the 2-contact model, the terminals 21, 22, 23, and 24 on the
D4D-R are 31, 32, 33, and 34 on the D4N-R.
3. Recommended Terminals
If the recommended terminals are not used, the Switch may not
be compatible. Make sure that the Switch is compatible with the
terminals.
Comparison of the D4D-R and Substitute Products
Dimensions (Unit: mm)
Model D4N-R
Switch color Very similar
Dimensions Very similar
Wiring/connection Significantly different
Mounting method Completely compatible
Ratings/performance Very similar
Operating characteristics Very similar
Operating method Completely compatible
Discontinued Models (1-conduit Plunger-type D4D-R) Replacement Products (1-conduit Plunger-type D4N-R)
Discontinued Models (2-conduit Plunger Type D4D-R) Replacement Products (2-conduit Plunger Type D4N-R)
20.5 ×20.5
6 dia.
14 dia.
2.15±0.05R
mounting holes
31 max. 0
Two, 4 +0.15 dia. holes
depth: 5
(See note.)
OP
6 dia. 11±
0.2
22±0.2
31 max.
55
47±0.2
2.5
OP (27)
9±
0.2
16.7
20±0.1
22±0.1
14 dia.
21.5
30
36
14.2
20.5 ×20.5
2.15±0.05R
mounting holes
0
Two, 4 +0.15 dia. holes
depth: 5
Conduit cap
(See note.)
20.5 ×20.5
2.15±0.05R
mounting holes
56 max.
6 dia.
14 dia.
25 dia.
Cap
0
Two, 4 +0.15 dia. holes
depth: 5
(See note.)
OP
11±
0.2
21.5
30
36
14.2
20.5
16.7
42±0.2 (3)
56 max.
47
39±0.2
25 dia.
2.5
9±
0.2
20±0.1
40±0.1
42±0.1
22±0.1
6 dia.
5.4
OP
14 dia.
(27)
20.5 ×20.5
2.15±0.05R
mounting holes
Cap
0
Two, 4 +0.15 dia. holes
depth: 5
Conduit cap
(See note.)
F502-EN2-04.book Seite 280 Dienstag, 26. Juli 2005 5:48 17

G-281D4N-@R
D4N-
@
R
List of Recommended Substitute Products
: The actuator on the D4D-R is a non-safety type. The D4N-R is recommended for safety applications (form lock type). Be sure to mount it
correctly. Using M screws is recommended to comply with European standards. Therefore, the M20 conduit model is recommended for use in new
designs.
Safety Limit Switch
D4D-R product to be
discontinued Recommended
substitute product D4D-R product to be
discontinued Recommended
substitute product
D4D-1520R D4N-1A20R D4D-1A20R D4N-1B20R
D4D-2520R D4N-2A20R D4D-2A20R D4N-2B20R
D4D-3520R D4N-3A20R D4D-3A20R D4N-3B20R
D4D-5520R D4N-5A20R D4D-5A20R D4N-5B20R
D4D-6520R D4N-6A20R D4D-6A20R D4N-6B20R
D4D-1531R D4N-1A31R D4D-1A31R D4N-1B31R
D4D-2531R D4N-2A31R D4D-2A31R D4N-2B31R
D4D-3531R D4N-3A31R D4D-3A31R D4N-3B31R
D4D-5531R D4N-5A31R D4D-5A31R D4N-5B31R
D4D-6531R D4N-6A31R D4D-6A31R D4N-6B31R
D4D-1532R D4N-1A32R D4D-1A32R D4N-1B32R
D4D-2532R D4N-2A32R D4D-2A32R D4N-2B32R
D4D-3532R D4N-3A32R D4D-3A32R D4N-3B32R
D4D-5532R D4N-5A32R D4D-5A32R D4N-5B32R
D4D-6532R D4N-6A32R D4D-6A32R D4N-6B32R
D4D-1562R D4N-1A62R D4D-1A62R D4N-1B62R
D4D-2562R D4N-2A62R D4D-2A62R D4N-2B62R
D4D-3562R D4N-3A62R D4D-3A62R D4N-3B62R
D4D-5562R D4N-5A62R D4D-5A62R D4N-5B62R
D4D-6562R D4N-6A62R D4D-6A62R D4N-6B62R
D4D-1572R D4N-1A72R D4D-1A72R D4N-1B72R
D4D-2572R D4N-2A72R D4D-2A72R D4N-2B72R
D4D-3572R D4N-3A72R D4D-3A72R D4N-3B72R
D4D-5572R D4N-5A72R D4D-5A72R D4N-5B72R
D4D-6572R D4N-6A72R D4D-6A72R D4N-6B72R
D4D-152HR D4N-1A2HR D4D-1A2HR D4N-1B2HR
D4D-252HR D4N-2A2HR D4D-2A2HR D4N-2B2HR
D4D-352HR D4N-3A2HR D4D-3A2HR D4N-3B2HR
D4D-1521R D4N-1A2GR D4D-1A21R D4N-1B2GR
D4D-2521R D4N-2A2GR D4D-2A21R D4N-2B2GR
D4D-3521R D4N-3A2GR D4D-3A21R D4N-3B2GR
D4D-5521R D4N-5A2GR D4D-5A21R D4N-5B2GR
D4D-6521R D4N-6A2GR D4D-6A21R D4N-6B2GR
D4D-1527R D4N-1A2HR D4D-1A27R D4N-1B2HR
D4D-2527R D4N-2A2HR D4D-2A27R D4N-2B2HR
D4D-3527R D4N-3A2HR D4D-3A27R D4N-3B2HR
D4D-5527R D4N-5A2HR D4D-5A27R D4N-5B2HR
D4D-6527R D4N-6A2HR D4D-6A27R D4N-6B2HR
F502-EN2-04.book Seite 281 Dienstag, 26. Juli 2005 5:48 17

G-282 Safety Sensors / Components
Warranty and Application Considerations
Read and Understand this Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or
other period if specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE
MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of
products in the customer's application or use of the products.
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will
be used.
Know and observe all prohibitions of use applicable to this product.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR
SYSTEM.
Disclaimers
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with
your OMRON representative at any time to confirm actual specifications of purchased product.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C132-E2-01-X
F502-EN2-04.book Seite 282 Dienstag, 26. Juli 2005 5:48 17
This manual suits for next models
124
Table of contents
Other Omron Switch manuals

Omron
Omron D40A-G9SX-NS - User manual

Omron
Omron H5F - User manual

Omron
Omron D4NL-1AFA-B User manual

Omron
Omron C2UW-L Series User manual

Omron
Omron Z User manual

Omron
Omron A22K User manual

Omron
Omron D4SL-N N Series User manual

Omron
Omron D4DH User manual

Omron
Omron A22LK Series User manual

Omron
Omron A165S - User manual