●Before the use, you should first thoroughly read
this manual and operate correctly as mentioned.
● You should keep this manual at hand for proper use.
Iuput/Output Circuit Design
NPN
PNP
Pin configuration ① 10〜30V DC
② Bank Color mode
③ 0VL.ON Output is active when matched
④ Control output D.ON Output is active when un-matched
Mark mode
L.ON Output is active for high reflection
D.ON Output is active for low reflection
When 2 point teach, the 1st selected color will be ON.
Press both Up and Down button simultaneously for more than 2 sec.
( Same procedure for unlock.)
* For connector type only
● Specifications and equipment are subject to change
without any obligations on the part of manufacture.
● For more information, questions and comments
regarding products, please contact us below.
For safety use Manufactured and sold by :
○ Warm-up period (approx. 100 msec) must be secured.
○ Should avoid to use sensor outside or at the place where receiver is
influenced by environmental illuminance directly.
○ Gaps in indicated values and detection features are possible due to dispersion.
○ Use of controls or adjustments or performance of procedures
other than the specified herein may result in hazardous radiation exposure.
0535402
Operation mode Light ON / Dark ON selectable
Teaching Mark mode:2 point teach/Auto teach Color mode:1 point teach
8 bank
IEC IP67 / Housing : heat-resistant ABS(antibacterial) Front cover : PMMA Button : TEEE
Weight cable type: about 75g / connector type: about 20g
Scanning range
Protection category/ material
7 segment, 3 digits LED Green:Bank No. Red:Function, Status
Control output NPN/PNP Open collector 100mA max./ DC30V
●Confirm if the item meets your needs.
Bank
Response time Mark mode: 0.25/0.5/1.2ms selectable Color mode: 0.8/1.6/4ms selectable
R (634nm) / G (517nm) / B (469nm)
Timer Off delay / On delay / One shot delay (10msec increment :0-1,000msec, 1sec increment for 1-10sec)
Light source Mark mode:1 color (selected by teaching) Color mode:RGB automatic selection
Type Cable type M8 Connector type
DM-18T (N,P) DM-18TC (N,P)
INSTRUCTION MANUAL
18mm ± 2mm
Digital indicator Output indicator(Orange LED) , Stable indicator (Green LED)
Indicator
Supply voltage DC10 〜 30V including 10% ripple (P-P)
Current consumption 40mA max.
D SERIES
Unit: mm
laser emitter indication
output indicator
digital display panel
Up button
Teach / Enter
Press teach button
Press + button
during more than 2 s.
or
Press - button
during more than 2 s.
Yes
No
Low (Resolution : High)
Middle (Resolution : Middle)
High (Resolution : Low)
ON delay 10ms
OFF delay 990ms
Without timer
Every
D.ON
L.ON
Bank Bank '0'
(ch)
Bank '7'
Response time, L.ON/D.ON, Color/Mark mode can be set for each Bank. RUN mode
RUN mode
T
T
Status Indicator
Function
select mode Indicate selectable function.
RUN mode Indicate matching level
compare to teaching
color. Indicate remission
Thresh level
adjust mode
Indicate thresh lebel.
After teaching, thresh
Indicate thresh level.
After teaching, thresh
Color mode Mark mode
Cable type
Bank No. Green Pink Yellow
0 0 0 0
1 0 0 1
2 0 1 0
3 0 1 1
4 1 0 0
5 1 0 1
6 1 1 0
7 1 1 1
Connector type
Bank No. No. 2 pin
0 0
1 1
Connector type can select only 1 and 2
by remoto selection.
(Function select by button is 8 banks.)
NPN
PNP
NPN
PNP
0
1
Open or connect to +V
Open or connect to 0V
Connect to 0V
Connect to +V
Refer to 「FUNCTION」
Color mode Mark mode
2 point teaching Auto teaching
Set Keep pushing teaching
the first object (color) button
Through the object once
Release teaching button
Set
the second object(color)
OK NG
RUN mode
Select 'Bank'
Select mode (Color or Mark)
Set the object (color)
Push teaching button Push teaching button
Push teaching button
Press Up or Down button
Display start blinking
Adjust thresh lebel by Up or Down button
Press teach button, then back
to RUN status
If without pressing teach button
buck to RUN status automatically after 10 s.
!Must not use this item as safety equipment
for the purpose of human body protection.
indicates amount
of incoming light.
If without pressing Teach button, it goes back to
RUN automatically after 10 sec.
Turn the connector as Black Arrow
indicates, otherwise you will damage the
connector. The damage will be unrepairable.
607-8085 Kyoto, Yamashina,Takehanadonomaecho 46-1, JAPAN
Tel : +81-(0)75-594-8123
Fax : +81-(0)75-594-8124
Website : http//www.optex-fa.com
foreside
Down button backside