SPECIFICATIONS
OTHER PRECAUTIONS
™Be carefull not to install the sensor at the follwing locations,
as it may otherwise malfunction.
¡¡Where a lot of dust, vapor, or the like is present.
¡¡Where corrosive gas is produced.
¡¡Where water, oil or the like flies directly onto the sensor.
¡¡Where strong vibration or shock is caused to the sensor.
™Do not use organic solvent, such as thinner, to remove
contaminants from the body case, lid, and lens which are all
of prastics. Using a dry rag, just wipe clean.
™When a swiching regulator is to be used with a power supply,
be sure to ground the Frame Ground Terminal.
™Do not use the sensor in a transient state at power on.(about
100ms)
™Do not run sensor cable near a high-voltage lines, or power
lines or put them together in the same raceway. This warning
should be strictly observed to prevent malfuncdtions caused
by inductive interference.
HOW TO USE
¡Connection
™Install the cables to match the connection terminal No. as
shown below.
™Use either lead-in opening A or B according to the
installation method involved.
™Install a vlinding bolt at the lead-in opening not to be used.
¡¡The figure below shows how the cables are installed when
lead-in opening A is used.
¡※1 Cable packing is selected separately either for cable or
blinding bolt according to cable diameter.
Large : φ8〜φ10 Small :φ6〜φ8
¡※2 Washer is to be used exclusively to the cable bolt.
™Dimensions of applicable solderless terminals
¡Use solderless terminals with insulating tube.
™Use 6 to 10 mm diameter cables circular in section to
maintain waterightness.
™Wrong wiring may be a cause of burned or damaged sensor.
Pay due attention to wiring.
™Be careful not to inslall the cable near power lines, for
otherwise the sensor may mulfunction.
™Using the mounting accessories supplid, the sensor can be
installed on either floor or wall.
DIMENSIONS
Manufactured and sold by :
OPTEX FA CO.,LTD.
600-8815 Kyoto, Shimogyo, Awata Chudoji 93, Japan
TEL. +81−(0)75−325−2920
FAX.
+81−(0)75−325−2921
Website : http//www.optex-fa.com
0550211
3.2 8
14
AC/DCtype DCtype
ThroughBeam RetroReflection
DiffusedReflection DiffusedReflection
RetroReflection
DiffusedReflection
(withPolarizingfilter)
(LongRangetype)
ThroughBeam
(withPolarizingfilter) DiffusedReflection
(LongRangetype)
withouttimer
withtimer
withouttimer
withtimer
withouttimer
withtimer
withouttimer
withtimer
Terminal
VT-4000 VT-4000T VR-1000 VR-1000T VD-130 VD-130T VD-300 VD-300T
VT-3000N VR-800N VD-100N VD-250N
Type
VT-3000P VR-800P VD-100P VD-250P
M12
−−−−−−−−VT-3000CN VR-800CN VD-100CN VD-250CN
connector
VT-3000CP VR-800CP VD-100CP VD-250CP
Detectingdistance
40m 10m 1.3m 3m 30m 8m 1m 2.5m
SupplyVoltage DC12〜240V±10% AC24〜240V±10% 50/60Hz DC10〜30V±10%
Power/CurrentConsumption
8.5VA 5VA 35mAmax.
DetectingObject
φ30mm φ50mm □20cm □40cm φ30mm φ50mm □20cm □40cm
ResponseTime 20msmax. 1.5msmax. 5msmax.
Hysterisis − 20% max. − 20% max.
LightSource RedLED IRLED RedLED IRLED
SensitivityAdjustment
1rotationvolume(240°)
Indicator Outputindicator(Orange)PowerIndicatorforEmitter(Red)
Timerfunction −
ON/OFFDelay
−
ON/OFFDelay
−
ON/OFFDelay
−
ON/OFFDelay
−
0.1〜10sec 0.1〜10sec 0.1〜10sec 0.1〜10sec
OperatingMode LightON LightON/darkONselectablebyvolume
ControlOutput Relayoutput1cAC240V3Amax./DC30V3Amax.(Resistiveload) NPN/PNPOpencollectorDC30V100mAmax.
Connection Terminalbase(Diameterofapplicablecable:φ6〜φ10mm)
Terminalbase(Diameterofapplicablecable:φ6〜φ10mm)/M12Connector
AmbientTemperature
−25〜+55℃(Nofreezing)
AmbientHumidity
35〜85%/RH
EnvironmentalIlluminance
SunLight:10,000luxmax. Halogenlight:3,000luxmax.
InsulationResistor
20MΩ/DC500V
WithstandVoltage
AC2700V 1minute −
VibrationResistance
10〜55Hzamplitude1.5mm X.Y.Z.each2hours
ShockResistance
50G(500m/s) X.Y.Z.each2hours
Protectioncategory
IEC144IP67
Material Case/Cover:ABS(glassfiberIncluded) Lens:PMMA
NAME OF PARTS
™AC/DCtype
™DCtype
※Test Input function for through-beam
typeisequippedtoemitter.
NOCOM.
TestInput
Output
INPUT AND OUTPUT CIRCUIT
DIAGRAMS
™AC/DCtype
™DCtype
When the No.3terminal is connected to 0V
(NPNtype)or 10〜30VDC(PNPtype), an
interruptedstatusiselectrically invented by
stoppageofemission.Thisfunctioncanbe
usedastheoperationalcheckofthesensor
by electric interrupted state without
detectableobject.
TIMER CHART TEST INPUT FUNCTION
ACCESORIES
™Standard reflection mirror Type V-61
(for Retro-reflection model)
Output ON
Output OFF
NPNtype
PNPtype
Throughbeamemitter
ConnectorpinNo.
Photoelectric Sensor
V SERIES
・VT-4000□・VT-3000□□
・VR-1000□・VR-800□□
・VD-130□・VD-100□□
・VD-300□・VD-250□□
AC/DC Type
DCAC/ Type
AC/DC Type DC Type
INSTRUCTION
MANUAL
¡Confirm if the item meets your needs.
¡Before the use, you should first thoroughly read
¡this manual and operate correctly as mentioned.
¡You should keep this manual at hand for proper use.
Must not use this item as safety equipment
for the purpose of human body protection
¡Specifications and equipment are subject to change
¡without any obligations on the part of manufacture.
¡For more information, questions and comments
¡regarding products, please contact us below.
0550210/光電Vシリーズ08.10.2017:38ページ1