● Installationmustconformtoalllocalplumbingcodesandregulations.
● DoNOTusewithwaterthatismicrobiologicallyunsafeorofunknownqualitywithoutadequatedisinfection
beforeorafterthesystem.
● Connectsystemtocoldwatersupplyonly!Watertemperaturemustnotexceed100°F/38°C.
● DoNOTsolderplumbingconnectionsattachedtothelterhousingorinletvalve.Hightemperaturewill
damagethesecomponents.
● DoNOTover-tightenttingconnectionsintoinletvalveorhousingoutlet.Alwaysback-upvalvesand
ttingswithawrenchtoavoidturningthevalve.
● Allowaminimumof3”underthehousingtoallowforsumpremovalandlterreplacement.
● DoNOTmountthesystemnearaheatsourceorabovetheelectricalwiringoranydeviceorareathat
wouldbeadverselyaffectedbywater.
● DoNOTmountthesystembehindequipment.Theunitmustbeeasilyaccessibleforlterreplacement.
● FailuretochangecartridgesperrecommendedintervalswithOptiPurereplacementcartridgesmayleadto
systemfailureandpropertydamage.
Introduction
YournewOptiPureQT-SeriesFoodServiceFiltrationSystemwillcleanseandconditionthetapwaterproviding
optimumwatercharacteristicsfortheirspeciedapplications.Theresultisreducedequipmentmaintenancerequire-
ments,longerequipmentlifeandimprovedquality&consistencyofyourproducts.TheOptiPureSystemisbuiltwith
thenest,mostadvancedmaterialsandeachsystemisqualityinspectedandpressuretestedpriortoshipment.
Propersysteminstallationandroutinelterchangeswillensureyearsoftrouble-freeoperationandperformance.
Pleaserefertothismanualwhenperformingroutinelterchanges.Theinstructionsmakeperiodicmainte-
nancequickandeasy,andensureyouwillreceivemaximumbenetfromyoursystem.
System/OperatingSpecications&Dimensions
MaximumPressure:125psi/8.6barMaximumTemperature:100°F/38°C,Min.:35°F/2°C
Inlet/OutletConnections:3/8”fnpt
Capacity:Changefiltersatgallonratingoratleastevery6months,orwhenpressuregaugeneedleentersthered
zoneontheoutletgaugewhilewaterisflowingthroughthefiltersystemundernormaloperatingconditions.
DONOTDISCARD-GIVETHISMANUALTOTHEOWNERAFTERINSTALLATION
ModelQT1+CR,QTI1+CR
ChlorineReductionCapacity:
20,000gals./75,708L
ChloramineReductionCapacity:
6,000gals./22,712L
SedimentReduction:
0.5Micron
ServiceFlowRate:
(ChlorineRedn)2.5gpm/9.5lpm
(ChloramineRedn)0.5gpm/1.9lpm
Installation, Operation & Maintenance Manual
For QT Series Model:
QT1+CR
-to Reduce Particulate, Chlorine, Chloramine, Taste & Odor
For QTI Series Model:
QTI1+CR
-to Reduce Particulate, Chlorine, Chloramine, Taste, Odor & Scale