DO NOT DISCARD - GIVE THIS MANUAL TO THE OWNER AFTER INSTALLATION.
DO NOT DISCARD THIS MANUAL AFTER INSTALLATION. THIS MANUAL CONTAINS IMPORTANT
OPERATION, MAINTENANCE AND PRECAUTIONARY INFORMATION. PLEASE PRESENT THIS MANUAL
TO USER/OPERATOR/OWNER AFTER INSTALLATION.
IT IS STRONGLY ENCOURAGED THAT YOU READ THIS MANUAL BEFORE INSTALLING SYSTEM TO
ENSURE THE BEST POSSIBLE INSTALLATION.
INSTALLATION MUST CONFORM TO ALL LOCAL AND STATE PLUMBING CODES AND REGULATIONS.
CONNECT SYSTEM TO COLD WATER SUPPLY ONLY. WATER TEMP. CAN NOT EXCEED 100°F/38°C.
SYSTEM MUST BE INSTALLED IN A VERTICAL AND UPRIGHT POSITION.
SCALEX2®SYSTEMS MUST NOT BE USED IN CONJUNCTION WITH POLYPHOSPHATE OR ANY OTHER
SCALE INHIBITOR.
DO NOT INSTALL FILTERS DOWNLINE FROM THE SCALEX2®SYSTEM. SCALEX2®MUST BE THE LAST
FILTER SYSTEM BEFORE THE EQUIPMENT.
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY
WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM.
FAILURE TO CHANGE CARTRIDGES PER RECOMMENDED INTERVALS WITH OPTIPURE REPLACE-
MENT CARTRIDGES MAY LEAD TO SYSTEM FAILURE AND PROPERTY DAMAGE.
Introduction
Your new OptiPure ScaleX2®FoodService Filtration System will condition the tap water, providing optimum water
characteristics for specied applications. Results include reduced equipment-maintenance requirements, longer
equipment life and improved quality and consistency of your products. Proper system installation and routine lter
changes ensure years of trouble-free operation and performance.
The OptiPure System is built with the nest and most advanced materials. Each system is quality inspected and
pressure-tested prior to shipment. With proper installation and routine maintenance, you should have years of
trouble-free operation.
Please refer to this manual when performing routine lter changes. The instructions make periodic maintenance quick
and easy, and ensure that you should receive maximum benet from your system.
Installation, Operation & Maintenance Manual
Reduce Scale
For ScaleX2
®
Models: SX2-11, SX2-12, SX2-12B
Operating Specications
Maximum Pressure: 125 psi/8.6 bar Maximum Temperature: 100°F/38°C
Minimum Temperature: 35°F/2°C
Installation Precautions
• Do NOT install system on line pressure above 125 psi.
• Do NOT install the system backwards with the feed water line connected to the outlet.
• Do NOT use liquid pipe compounds for tting connections. USE two to three wraps of teon tape.
• Do NOT solder plumbing connections attached to lter housing or inlet valve. Inlet valve and lter housing will
be damaged by high temperature.
•
Do NOT allow system to freeze. Turn off water supply to housing and drain housing if temperature falls below 32°F.
• Do NOT install system in direct sunlight or where system is exposed to harsh chemicals, or where it may be
subjected to being struck by moving equipment, carts, mops or any other item that may cause damage.
• ALLOW a minimum of 3” under the housing to allow for lter replacement.
• IF water hammer is evident, install water hammer arrestors before OptiPure unit.
• Do NOT overtighten tting connections into inlet valve our housing outlet.
• Always back-up valves and ttings with a wrench when installing a tting to avoid turning the valve.
• Do NOT install the unit behind equipment where it may be difcult to access the system for lter replacement.