manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. optrel
  6. •
  7. Respiratory Product
  8. •
  9. optrel P.Air Clear User manual

optrel P.Air Clear User manual

This manual suits for next models

1

Other optrel Respiratory Product manuals

optrel e3000X User manual

optrel

optrel e3000X User manual

optrel e1100 User manual

optrel

optrel e1100 User manual

optrel 4900.040 User manual

optrel

optrel 4900.040 User manual

optrel SWISS AIR User manual

optrel

optrel SWISS AIR User manual

optrel P.AIR User manual

optrel

optrel P.AIR User manual

Popular Respiratory Product manuals by other brands

Dräger PSS Series Instructions for use

Dräger

Dräger PSS Series Instructions for use

ResMed MIRAGE SWIFT II 60891/1 user guide

ResMed

ResMed MIRAGE SWIFT II 60891/1 user guide

Omron COMP A-I-R NE-C801 instruction manual

Omron

Omron COMP A-I-R NE-C801 instruction manual

Ombra 63506 Instructions for use

Ombra

Ombra 63506 Instructions for use

Lotus M-9520A quick start guide

Lotus

Lotus M-9520A quick start guide

CERES nosko nebulizer kit manual

CERES

CERES nosko nebulizer kit manual

Dr.Frei NE-SM1 user manual

Dr.Frei

Dr.Frei NE-SM1 user manual

North 5400 series instruction manual

North

North 5400 series instruction manual

John Bunn Neb-u-Lite LX2 user manual

John Bunn

John Bunn Neb-u-Lite LX2 user manual

Philips Respironics EE Leak 1 AF541 Instructions for use

Philips

Philips Respironics EE Leak 1 AF541 Instructions for use

Sperian Panther Hip-Pac P9684 Series Operation manual

Sperian

Sperian Panther Hip-Pac P9684 Series Operation manual

Dräger X-plore 6570 quick start guide

Dräger

Dräger X-plore 6570 quick start guide

3M 8000 Series quick start guide

3M

3M 8000 Series quick start guide

Respironics SideStream HS860 Instructions for use

Respironics

Respironics SideStream HS860 Instructions for use

Sundstrom SR 500 Instructions for use

Sundstrom

Sundstrom SR 500 Instructions for use

Ambu SPUR II Instructions for use

Ambu

Ambu SPUR II Instructions for use

BLS 8000 Instructions for the use

BLS

BLS 8000 Instructions for the use

Dräger saver PP Series Instructions for use

Dräger

Dräger saver PP Series Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

p.air clearp.air clear
user manualuser manual
IMPORTANT
Please keep this User Instruction for your reference. This respirator
reduces the exposures to airborne particles. All wearer must read and
understand this User Instruction provided as a part of the product
packaging. Follow all local regulations. A written respiratory protection
program must be implemented in accordance of the requirements of
OSHA 1910.134, including training, fit testing and medical evaluation.
Keep this User Instruction for future reference. Please note: This
respirator is intended for single use and cannot be reused.
Use For
•
Particles such as those from grinding, sanding, sweeping,
sawing, bagging, or processing minerals, coal, iron ore, flour,
metal, wood, pollen and other solid particles.
• Liquid or non-oil based droplets from sprays that do not also
emit oil aerosols or vapors.
•
Solid particulates and liquid mists in concentrations not
exceeding 10x PEL/OEL. Follow all applicable local regulations.
For additional and latest information visit the webpage www.optrel.
com. Always follow the User Instruction and use in indicated manner.
Do Not Use For
DO NOT use for gases, vapors, oil containing aerosols, absestos,
arsenic, cadmium, lead, 4,4-methylene dianiline (MDA) or abrasive
blasting. DO NOT use for particulate concentrations exceeding 10x
the occupational exposure limit or applicable government regulations,
whichever is lower. DO NOT use in a manner not specified in the
instructions for use. This respirator does not supply oxygen.
Biological Particles
The respirator reduces inhalation exposures to airborne biological
particles (e.g. M.Tuberculosis) but cannot offer absolute protection from
infections, illness or disease. OSHA and other government agencies
have not established safe exposure limits for these contaminants.
Use Instructions
1. The respirator is intended for single use and cannot be reused.
2. Store the respirator away from contaminated areas.
3. Inspect respirator before use to ensure that it is in good operationg
condition. Examine all the respirator parts for signs of damage including
the two headbands, attachment points and nose clip. The respirator
must be disposed immediately if parts are damaged or missing.
The filtering facepiece must be inspected prior use: Make sure the
breathing zone is free from any damage. Immediately replace respirator
if damaged.
4. Failure to follow all instructions and limitations on the use of this
respirator and/or failure to wear this respirator during all times of exposure
canreducerespiratoreffectivenessandmayresultinsicknessordeath.
5. In the U.S., before occupational use of this respirator, a written
respiratory protection program must be implemented meeting all the
requirements of OSHA 29 CFR 1910.134, such as training, fit testing,
medical evaulation, and applicable OSHA substances specific
standars. Follow all applicable local regulations.
6. Leave a contaminated area immediately and contact supervisor if
dizziness, irritation, or other distress occurs.
7. Conduct a seal check before each use as specified in the Fitting
Instructions section. If you cannot achieve a proper seal, do not
use the respirator.
8. Change the respirator when it is saturated with humidity, particulates
or breathing becomes difficult; or every 4 hours after continuous use,
only change in a safe environment.
9. Dispose the used product in accordance with all applicable
regulations.
Use Limitations
1. This respirator does not supply oxygen. Do not use it in
atmospheres containing less than 19.5% oxygen.
2. Do not use respirator when concentrations of contaminants are
immediately dangerous to life and health, are unknown or when
concentrations exceed 10x the permissible exposure limit (PEL) or
according to specific OSHA standards or applicable government
regulations, whichever is lower.
3. Do not alter, wash, abuse or misuse the respirator.
4. The respirator is intended for single use and cannot be reused.
5. Do not use with beards or other facial hair or other conditions
that prevent a good seal between the face and the sealing surface
of the respirator.
6. Respirators can help protect your lungs against certain airborne
contaminants. They will not prevent entry through other routes
such as the skin, which will require additional personal protective
equipment (PPE).
7. This respirator is designed for occupational/professional use by
properly trained adults. This respirator is not designed to be used
by children.
1
2
3
4
5
Use clean hands when handling a respirator.
1. Remove packaging and open the respirator and take hold of the head straps.
2. Hold the respirator over your nose, mouth and chin, lightly secure on the face with
one hand on the outside, and with your free hand pull the two retaining straps over
your head. Do not touch the respirator on the inside.
3. Pull the lower retaining strap under your ears and pull the upper retaining strap
over the back of your head.
4. Press the nose clip onto your face with both index fingers.
Spectacle wearers: remove the spectacle to adjust the nose clip!
Pinching the nose clip using one hand may result in improper fit and less
effective respirator performance. Use two hands.
5. Perform a User Seal Check prior to each wearing. To check the respirator-
to-face seal, place both hands completely over the respirator and exhale
sharply. Be careful not to disturb the position of the respirator. If air leaks
around nose, readjust the nosepiece as described in step 4.
If you CANNOT achieve a proper seal, DO NOT enter the contaminated
area. Report to your supervisor.
Fitting - and Removal Instructions
Removal Instructions:
Spectacle wearers: remove glasses before removing the respirator.
Hold the retaining straps with both hands, pull over your head and remove the respirator from
your face. Remove the respirator without touching the respirator components. Wash and
clean your hands after removing the respirator. Dispose of used product in accordance with
applicable regulations.
Single use only! Do not reuse!
Storage Conditions and Shelf Life (Details see last page)
Before use, store respirators in the original packaging away from
contaminated areas, dust, sunlight, extreme temperatures, excessive
moisture and damaging chemicals.
When stored in accordance with temperature and humidity conditions
specified below, the product may be used until the "use by" date
specified on packaging. Always inspect product and conduct a user
seal check before use as specified in the User Instructions. If you
cannot achieve a proper seal, do not use the respirator.
Time Use Limitation
If respirator becomes damaged, soiled or breathing becomes difficult
(e.g. saturated with breathing air humidity), leave the contaminated
area immediately and replace the respirator.
The respirator is intended for single use and cannot be reused.
Acceptable Fit Test Protocols
Fit Test Protocol*
Qualitative Protocols Saccharin Acceptable with this product!
Bitrex TM Acceptable with this product!
Quantitative Protocols* Acceptable with this product!
*Refer to OSHA 1910.134.
9610.224 UI Rev A9610.224 UI Rev A
9610.224.019610.224.01
declaration of conformity
https://www.optrel.com/service/downloads/
optrel tec ag
Industriestrasse 2
CH-9630 Wattwil
Phone: +41 (0)71 987 42 00
Fax: +41 (0)71 987 42 99
[email protected]
www.optrel.com
Specifications (We reserve the right to make technical changes)
Material Composition Straps:Latex free elastic
Nose clip: Metal
Nose foam: Polyurethan
Window: Polypropylen
Filter: Polypropylen
Weight Approximate 0.25 oz.
Country of Origin Made in Switzerland
Standards NIOSH (see below)
End of Shelf Life
Use respirators before the "used by" date specified on the
packaging
(date format MM/YYYY)
Storage temperature Range
+23°F (-5°C) to +77°F (+25°C)
Storage Maximum Relative Humidity
<80% RH (not exceeding 80%) <80% HR
+25°C
+77°F
-5°C
+23°F
optrel inc.
5 Division St #35
US-East Greenwich, RI 02818
Phone: +1 401-398-7240
Fax: +1 401-398-2740