4324C-V1636 MULTIBEACON CHARGER
2
1.0 BATTERY CHARGER SPECIFICATIONS
Dimensions of enclosure: 6.3"l x 3.6"w x 2.5"h
Input: fused 0.5 amp (2 each)
Input voltage: selectable, 100, 120, 220 VAC +10% 50/60 Hz
Input current: 32mA AC @ No Load
Output current: switch selectable 150mA or 300mA
Output: Short circuit protection (current limited)
Input connector: i.e.c. Type enclosure mounted
Output connector: Two screw terminals mounted on case
Temperature rating: -10° to 55° c
2.0 OPERATION AND MAINTENANCE
2.1 The Model 4324C-V1636 is a desk top NiCad battery charger. It is designed to work
at 110/120/220 volts AC 50/60Hz This is manually selected (see Figure 1).
This charger is compatible with both the 4370 series Multibeacons.
The 4324C-V1636 is switch selectable to provide either 150mA or 300mA for either
one or two NiCad battery packs. The 4324C-V1636 will fully charge one Model 4370
or Model 4376 in 14-16 hours at the 150mA settings and or two Model 4370 or
Model 4376 beacons in 14-16 hours at the 350mA setting. It will also fully charge
one 4377 or 4378 telemetry beacon in 14-16 hours at the 300mA setting.
The 4324C-V1636 has internal short circuit protection, however, it is not
recommended to maintain a short for any extended period of time.
2.2 CONFIGURING THE CHARGER FOR SINGLE INTERNAL BATTERY PACK
MULTIBEACONS (SEE TABLE 1)
2.2.1 Select the proper AC input voltage, 100/120/220VAC, reference Figure 1 for details.
2.2.2 If charging one beacon select the 150mA position on the current selection switch
(see Figure 1).