13. GENERAL SPECIFICATIONS
Table 13.1
Item Description
Input
signals
Flow input
Signal name Pulse
generator Power to generator Speed of
response
2-wire, 12VDC 3-wire
contact-closure pulse −13.5VDC
Allowable
current
40mA app.
Shortcircuit
protection
circuit
provided
50Hz
2-wire, 12VDC 3-wire
voltage pulse −13.5VDC
2kHz
24VDC 2-wire
current pulse (4/20mADC) PA15, 25 24.0VDC
2-wire, 12VDC 3-wire
open collector pulse −13.5VDC
32VDC 3-wire
open collector pulse PA11 32.0VDC
Temperature input Resist. thermometer Pt 100Ωat 0°C, 3-wire Rated current 2mA
Analog 4 to 20mADC or 1 to 5VDC
Pressure input 4 to 20mADC or 1 to 5VDC
Output
signals
Pulse output
Uncorrected total flow Static relay Capacity: 230VAC/340VDC 0.2A
Pulse width: 1ms/50ms
Corrected total flow
Output sync with flow
input signal Open collector pulse
Alarm output Static relay Capacity: 230VAC/340VDC 0.2A
Analog output Corrected instant
flowrate
4 to 20mADC (Max. load resistance 500Ω)
or 1 to 5VDC (Output impedance 250Ω)
Conversion accuracy: ±0.1% of F.S.
Display type Display: ST display (128×128 dots), backlighted (※1), (※2)
Information displayed: Data, units, error message simultaneously
Menu
items
Uncorrected total flow Same as output pulse unit (m3, etc.) Display capacity: 8 digits
Corrected total flow Same as output pulse unit (m3(nor), etc.)
Uncorr. instant flowrate
m3/h, etc.
Corr. instant flowrate m3/h (nor), etc.
Temperature To the 2nd decimal place (when °C is selected.)
Pressure To the 4th decimal place (when MPa is selected.)
Correction factor To the 4th decimal place
Meter error corr. factor To the 5th decimal place
3αcorrection factor To the 4th decimal place
T/P correction factor To the 4th decimal place
Quadratic corr. factor To the 4th decimal place
Error alarm Number of errors + error messages
Com-
puting
range
Temperature Pt100Ωat 0℃
Range: −50 to +350°C
Std. Span: 70℃
4 to 20mADC or 1 to 5VDC Std. Span:200℃
Pressure 0 to 3MPa Standard span: 1/2Pmax. to Pmax., 1/5Pmax. to Pmax. (※3)
Com-
puting
accu-
racy
Corrected total flow 1/2Pmax. to Pmax. ±0.2% of R.D.
1/5Pmax. to Pmax. ±0.5% of R.D.
Temperature Pt 100Ωat 0℃ ±0.3% of span
4 to 20mADC or 1 to 5VDC ±0.1% of span
Pressure ±0.1% of SPAN
Clock IC battery backup Lithium battery (Battery life: 10 years approx.)
Communication (when com.
interface is provided.)
Interface: RS485 Multipoint (Up to 16 units can be connected.)
Dedicated protocol Baud rate: 4800 bps standard 9600 bps max.
Transmission cable
Use 3-conductor shielded cable to the resistance thermometer bulb.
Loop resist. 5Ωmax. Example: 300 meters max. with 3-conductor 1.25mm2cable;
500 meters with 2.0mm2cable
Power source 85 to 264VAC, 50/60Hz or 20 to 30VDC
Power consumption 20W max.
Ambient temperature −10 to +50°C
Mounting Panel mount
Finish Munsell N1.5
Weight 2.5 kilograms, approx.
NOTES (※1): ST display stands for Super Twisted Nematic display.
(※2): Backlight life (luminance declined to one half its original luminance): 2500 hours, approx.
(※3): Pmax. to be a value corresponding to 20mA (or 5V) in pressure input.