CAUTION: PLEASE FOLLOW THIS INSTRUCTION MANUAL CAREFULLY TO
PREVENT ANY INJURIES OR COMPLICATIONS THAT MAY ARISE.
Before installing or maintaining the luminary, make sure all power is
WARNING:
.TURNED OFF
Verify that supply voltage is correct by comparing it with the label information on all
fixtures.
Make all connections in accordance with the NEC requirements, and make sure all
luminaries are properly secured to prevent any wire complications. This luminary is
to always be installed with the lens facing down and it is not to exceed the
maximum ambient temperature rating noted on the specification sheet.
FPTA Series Post Top Light Installation Guide
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2019 PacLights All Rights Reserved Note: Instructions are subject to change at any time without notice
FPTA35, FPTA55, FPTA75Includes:
02-00042-191212
Page 1 of 2
Connect the ACL and the ACN from the FPTA Fixture to the conduit with the AC Power Supply cords. Follow the Wiring Diagram provided.
AC Power Supply
ROUND [ ]
NEUTRAL [WHITE]
[BLACK]
INPUT
GRAY (-)
DIM
FPTA FIXTURE
VIOLET (+)
Tunable CCT (Correlated Color Temperature)
Turn over the FPTA Fixture showing the Fin side. Remove the flush rubber inserts
(4) from the Cover Panel. Remove the Screws (4) from the Cover Panel. Lift the
cover from the FPTA Fixture. The Fixture is now open to adjust (if needed) the
Tunable CCT setting. The process is the same for all FPTA Fixtures.
1
The FPTA Fixture removed from the box is in a vertical configuration. The FPTA Fixture will be in the horizontal position.
2The Tunable FPTA CCT Switch provides the user with
the three options available for the FPTA Luminaire.
4000K 5000K
3000K
4000K5000K
3000K
3After setting the CCT SWITCH to the desired Kelvin temperature place the
Cover Seal properly back on the FPTA Fixture rim. Then, carefully place the Cover
on the FPTA Fixture. Install the Screws (4) and then the Inserts.
INSERTS
SCREWS FPTA
COVER
FPTA Initial Set-Up
Remove the Screws (2) and
Brackets (2) from each side.
Rotate the FPTA Fixture to the
horizontal position fin side up.
The Brackets can be discarded.
1
SHORT-CAP
INSERTS
SCREWS
COVER
SEAL
FPTA CCT
SWITCH
FPTA
DRIVER
FPTA
COVER
FPTA
FIXTURE
Place the Screws (4) included to
secure the Fixture in the horizontal
position.
2
SCREW
BRACKET
3Set the Short-Cap on the NEMA
Receptacle correctly. Install the
Short-Cap provided by pressing down
and twisting CW.
Note: If Photocell Sensor is
provided see the following page for
instructions. SCREW
The Tunable CCT Switch is a device that allows the user to choose a desired color
temperature 3000K, 4000K, or 5000K. The default factory setting is 4000K.
Note: If the Color temperature is acceptable and the Tunable CCT does not need to
be adjusted, the following steps can be skipped.
COVER
SEAL
INSIDE BACK-
BOX
3
7
1
2
3
4
5
6
4
3
FPTA Series Post Top Light Installation Guide
02-00042-191212
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2019 PacLights All Rights Reserved Note: Instructions are subject to change at any time without notice
Page 2 of 2
The default settings can be changed by adjusting the DIP Switches on the Motion
Sensor. Please refer to the table on this page and also directly on the Motion Sensor.
Turn over the FPTA Fixture showing the Fin side. Remove the flush rubber inserts
(4) from the Cover Panel. Remove the Screws (4) from the Cover Panel. Lift the
cover from the FPTA Fixture. The Fixture is now open to adjust (if needed) the
Motion Sensor setting. The process is the same for all FPTA Fixtures.
Optional Microwave Motion Sensor
1
2
The Integrated Microwave Motion Sensor is a programmable motion detector.
The default factory settings are as follows: Detection Area=100%, Hold Time=5 sec,
Stand-By Period=0 sec, Stand-By Dimming Level=50%, and Daylight (Photo)
Sensor=Disable.
Note: If the Microwave Motion Sensor is not included or adjustment is not needed,
the following steps can be skipped.
INSERTS
SCREWS
COVER
SEAL
FPTA FIXTURE
FPTA
COVER
MOTION
SENSOR
DIP
SWITCHES
Microwave Motion Sensor Dip Pin Setting
Detection Area
Detection area having motion and not enough ambient light will activate the sensor.
The sensor can be set at 100%, 75%, 50%, or 25%.
Hold Time
Hold Time refers to the time period the fixture remains at 100% illumination after
motion is detected. Hold Time can range from 5s to 20 minutes. The fixture will
remain at full illumination until ‘Hold Time’ ends, then reducing to Stand-By dimming
level.
Stand-By Period
The Stand-By period begins when the ‘Hold Time’ ends. The fixture remains at a
Stand-By Dimming Level before it completely switches off while motion is not present.
When set to “+∞” mode, the low led light is held until motion is detected.
Daylight (Photo) Sensor
The Daylight Sensor, measured in LUX can be set to allow the fixture to illuminate
below a surrounding minimum ambient brightness threshold. The sensor can be set
from 5 to 150 LUX. When set to Disable mode, the Daylight Sensor will switch ‘ON’
the fixture when motion is detected regardless of ambient light.
Stand-By Dimming Level
Stand-By Dimming Level is when ‘Hold Time’ has ended, there is no movement in the
area and the light output is reduced. The Stand-By Dimming Level can be set at 50%,
30%, 20%, or 10%.
By selecting the combination on the DIP switches, sensor data can be precisely
set for each specific application as seen below.
PHOTOCELL
SENSOR
Turn over the FPTA Fixture showing the Fin side. All FPTA Fixtures come with
a NEMA Three-Prong Twist Lock receptacle with Short-Cap to be installed. Remove
the Short-Cap by twisting CCW and lifting.
Optional Photocell Sensor
The Photocell Sensor has a Dusk to Dawn functionality. The Photocell Sensor can be easily field installed on all FPTA fixtures as shown below.
Note: If the Photocell Sensor is not included the following steps can be skipped. If the Photocell Sensor is included prior to field installation,
Step 1 can be skipped.
1
SHORT-CAP
Place the Photocell Sensor on the NEMA receptacle. Push down and twist CW.
The process is the same for all FPTA Fixtures.
2
PHOTOCELL
SENSOR
SHORT-CAP
NEMA
RECEPTACLE
NEMA THREE-PRONG
TWIST LOCK PLUG
INSIDE BACK-
BOX
3
7
1
2
3
4
5
6
4
3

Other PacLights Lighting Equipment manuals

PacLights FFHS/3 Series User manual

PacLights

PacLights FFHS/3 Series User manual

PacLights FPNN Series User manual

PacLights

PacLights FPNN Series User manual

PacLights FCPC Series User manual

PacLights

PacLights FCPC Series User manual

PacLights FALC Series User manual

PacLights

PacLights FALC Series User manual

PacLights FSLN Series User manual

PacLights

PacLights FSLN Series User manual

PacLights FSTA/2 Series User manual

PacLights

PacLights FSTA/2 Series User manual

PacLights FFHL Series User manual

PacLights

PacLights FFHL Series User manual

PacLights FPTA/2 - 055/075 User manual

PacLights

PacLights FPTA/2 - 055/075 User manual

Popular Lighting Equipment manuals by other brands

BEARWARE 303586 manual

BEARWARE

BEARWARE 303586 manual

Clevertronics Argonaut PLUS Installation & maintenance

Clevertronics

Clevertronics Argonaut PLUS Installation & maintenance

Lightolier Calculite ProSpec PA3P3075 specification

Lightolier

Lightolier Calculite ProSpec PA3P3075 specification

EuroLite RGB FLOOD-1500 DMX MK2 user manual

EuroLite

EuroLite RGB FLOOD-1500 DMX MK2 user manual

ArchWork ARCPOD8 user manual

ArchWork

ArchWork ARCPOD8 user manual

DÖRR ML-2020 LED instruction manual

DÖRR

DÖRR ML-2020 LED instruction manual

Lightdiction KB2D quick start guide

Lightdiction

Lightdiction KB2D quick start guide

Eaton FlexiTech AT L Series manual

Eaton

Eaton FlexiTech AT L Series manual

Philips 56433-31-16 user manual

Philips

Philips 56433-31-16 user manual

EuroLite OMNILUX PAR-38 230V E-27 70 instructions

EuroLite

EuroLite OMNILUX PAR-38 230V E-27 70 instructions

NORLUX Anka 6700-04-1 installation manual

NORLUX

NORLUX Anka 6700-04-1 installation manual

Godox RING72 user manual

Godox

Godox RING72 user manual

Dilux AP6528 user manual

Dilux

Dilux AP6528 user manual

lap APW1008 Installation

lap

lap APW1008 Installation

JONATHAN Y JYL4007A instructions

JONATHAN Y

JONATHAN Y JYL4007A instructions

THORLABS CHROLIS Operation manual

THORLABS

THORLABS CHROLIS Operation manual

Hama 00176635 quick start guide

Hama

Hama 00176635 quick start guide

Evolights IQ 200 S user manual

Evolights

Evolights IQ 200 S user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.