150-412-182-01 December 22, 1997 Revision 01
HRU-412 List 8B PairGain Engineering - Plant Series 9
Local Powering
The HRU-412 List 8B unit is local powered. The -48 Vdc local power supply
must have a 83 mA output current capacity (4 W) to power each HRU-412
List 8B.
A Teltrend WPS-2005 Wall-Mount Power Supply, or equivalent, is capable
of powering two HRU-412 List 8B units.
Table 3. Back Panel User Options
Switch Setting Function
TLOS-LB DIS Does not allow theHRU-412 List8B toenteritslogic loopback state
whena loss of theT1XMT signalfromthe CPE causesthe HLU-319
List 4B to transmit the AIS signal toward the DSX-1.
EN Allowsthe HRU-412 List 8B to enterits logicloopback state when a
loss of the T1 XMT signal from the CPE causes the HLU-319 List 4B
List 4B to transmit the AIS signal toward the DSX-1. While in this
loopbackstate,theHRU-412List8BtransmitstheAISsignaltoward
the CPE and returns the network signal back to the network. The
HLU-319 List 4B displays TLOS in its front panel display. This
conditionremainsuntilavalidT1signalisreceivedfromthe CPEor
until the 3-in-5 in-band loopdown command is issued. Once the
TLOS initiated loopback occurs, it will not reoccur until the CPE T1
signal has been reapplied and then removed. This feature prevents
theHRU-412 List 8B from oscillating into and outofTLOSloopback
when a loopdown command is issued in the absence of a T1 signal
from the CPE. This TLOS option must never be enabled when the
HRU-412 List 8B is used with old line units that do not support this
feature. These older line units (List 6 and under) cannot loopdown
an HRU that is in a TLOS loop-up state when they receive the 3-in-5
in-band loopdown command.
RLEV 0Configures the T1 RCV level to 0 dB. This sets the T1 output signal
level from the HRU-412 List 8B toward the CI to 0 dB. Use this
setting when the HRU-412 List 8B is not functioning as a NID but is
connected to an external NID. It allows the external NID to set the
appropriate NI level.
15 ConfigurestheT1RCVlevel to-15dB.ThissetstheT1outputsignal
level from the HRU-412 List 8B toward the CI level to -15 dB. This
setting is recommended when the HRU-412 List 8B functions as a
NID.