manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Panamax
  6. •
  7. Surge Protector
  8. •
  9. Panamax Power 360 P360-8 User manual

Panamax Power 360 P360-8 User manual

Instruction
Manual
for
the
P360-8
POWER360
Features
SAC Outlets
8 surge protected
AC
outlets.
2
Modular
Dual-Port
USB
chargers
Each
Charging Station can charge
up
to
two
devices simultaneously
(2.1A
capacity).
Protect or Disconnect
Keeps electronics safe
from
power
spikes by
disconnecting load in a catastrophic event.
SmartGuard
Protects against
brownouts
and dangerous
over-voltage conditions. Disconnects
the
power
when
the
incoming
voltage falls
below
95
Volts
or
rises above 140 Volts. Reconnects
when
the
voltage returns
to
a safe level.
Circle
of
Protection
LED
indicator
monitors
the
outlet
wiring,
voltage and
protection
status.
Coax and Telco Protection
Protects
from
surges on coax and
telephone
signal lines,
while
maintaining full
bandwidth
for
high
definition
video
and high speed
internet
cable/DSL connections.
Lifetime Warranty
Limited
lifetime
product
warranty
plus $500,000 connected
equipment
protection
policy.
'"0
II
0
~
rn
;;o, I
g
I· I
• I
t
1· t-
t. -1
J - . 1 !
I f
,,
..---------
11
1
II
Caracterfsticas
de
POWER360
8 enchufes de corriente alterna
8 enchufes de corriente alterna
protegidos
contra sobretensi6n.
2 cargadores
USB
modulares
de
dos
puertos
Cada estaci6n decarga puede cargar hasta dos
dispositivos
al
mismo
tiempo
(capacidad 2.
1A)
.
Tecnologia
de
protecci6n
Protege los
productos
electronicos
de
picos
de
energfa
al
desconectarlos en caso
de
que
se
produzcan incidentes.
Protecci6n inteligente
Protege contra cafdas de tension y condiciones
peligrosas
de
sobretension. Desconecta
Ia
corriente
cuando
Ia
tension
entrante
cae
por
debajo
de los
95
voltios o sube
por
encima de los 140 voltios.
Se
reconecta cuando
Ia
tension
vuelve
a un nivel
seguro.
Circulo
de
protecci6n
El
indicador
LED
refleja el estado del cableado
de
los enchufes, el voltaje y
Ia
proteccion.
Coaxial y Protecci6n Telco
Protege
de
sobretensiones en lfneas coaxiales y
de
serial
de
telefono,
manteniendo
un
ancho
de
banda
completo
para
video
de
alta
definicion
y
las
conexiones de cable/DSL de alta
velocidad
de
Internet.
Garantia
de
por vida
Garantfa de
producto
limitada de
por
vida, mas
polftica de protecci6n de 500 000$ para equipos
conectados.
This Package
Includes:
(1)
POWER360 Eight
Outlet
Surge Protector
(2)
Modular
USB
charging
stations
(2)
6'
micro-
USB
to
USB
cables
(to
connect
charging station
to
base unit)
(2)
Rubber
feet
for
charging
modules
(1)
User manual
Este
paquete
incluye:
(1)
Protector
de
sobretension con
ocho
enchufes
POWER360
(2)
Estacion de carga
por
USB
modular.
(2)
Cable
de
1,8 m de micro-USB a
USB.
(Para
conectar
Ia
estacion
de
carga a
Ia
unidad
base)
(2)
Pies
de
goma
para el
modulo
decarga
(1)
Manual del usuario
Ce
pack
comprend
:
(1)
Huit protections de surtension murales
POWER360
(2)
Stations modulaires dechargement
USB
(2)
Cable micro-USB vers
USB
(6
pouces)
(pour connecter
Ia
station de charge a l'unite de
base)
(2)
Les
pieds en
caoutchouc
pour
le
module
(1)
Guilded'utilisateur
POWER360
Caracteristiques
8 prisesAC
8 Protecteurs de surtensions
pour
prises
AC
2 Chargeurs modulaires adouble ports
USB
Chaque station de chargement
peut
chargerjusqu'a
deuxappareils
simultanement
(capacite de
2,1
A).
Proteger ou Deconnecter
Protege
votre
equipement
electronique
en le
deconnectant
en
cas
de hausse
de
tension lors
d'un
sinistre.
SmartGuard
Protege
contre
les baisses
de
tension
et
les
conditions
de
surtension dangereuses. Deconnecte
!'alimentation
lorsque
Ia
tension d'entree
tom
be
en dessous
de
95
Volts ou s'eleve au-dessus
de
140
Volts, puis
Ia
reconnecte lorsque
Ia
tension retrouve
un
niveau stable
et
sur.
Cercle
de
protection
L'indicateur
LED
surveille l'etat
du
cablage
de
sortie,
de
Ia
tension
et
de
Ia
protection.
Protection Coaxiale
et
telephonique
Protege les Iignes
telephoniques
et
les cables
coaxiaux
contre
les
~urtensions
tout
en
maintenant
Ia
totalite
de
Ia
bande
passante de connexions
internet
cable/ADSL
pour
vous assurer
une
vitesse
exceptionnelle
et
des videos en
haute
definition.
Garantie avie
Garantie limiteeavie
du
produit
en
complement
d'une
politique
de
protection
d'equipement
connecte de $500,000.
Properly Connecting Your
PANAMAX
POWER360
To
completely
protect
your
equipment
from
surges,
every
wire
leading
into
or
out
of
the
equipment
you
want
to
protect
must
be
connected
to
the
appropriate
Panamax
surge
protector.
Damaging
lightning
and
power
surges
can
enter
your
system
through
any
AC
power
or
signal-line
(phone
line,
grounding
wires,
coax
cables,
modem
cables,
LAN
cables,
etc.)
connected
to
your
electronic
equipment.
The
Panamax
Connected
Equipment
Protection
Policy
is
void
if
any
wire
leading
into
or
out
of
the
equipment
is
not
properly
connected
to
the
appropriate
Panamax
surge
protector.
The
surge
protector
must
also
be
plugged
into
a
properly
wired
and
grounded
outlet.
Please
see
the
warranty
for
details
or
contact
the
Panamax
Tech
Support
Department
with
questions.
Important
Safety Points
Panamax
POWER360
and
the
connected
equipment
must
be
indoors,
in
a
dry
location
and
in
the
same
building.
Although
your
Panamax
POWER360
is
very
durable,
its
internal
components
are
not
isolated
from
the
environment.
Do
not
install
any
Panamax
product
near
heat
emitting
appliances
such
as
a
radiator
or
heat
register.
Do
not
install
this
product
where
excessive
moisture
is
present;
for
example
near
a
bathtub,
sink,
pool,
basement
floor,
fish
tank,
etc.
It
is
not
uncommon
for
a
building
to
be
improperly
grounded.
In
order
to
protect
your
equipment,
Panamax
products
must
be
plugged
into
a
properly
wired
and
grounded
3-wire
outlet.
Additionally,
building
wiring
and
grounding
must
conform
to
applicable
NEC
(USA)
or
CEC
(Canada)
codes
for
the
Panamax
protection
policy
to
be
valid.
Circle
of
Protection
The
CIRCLE
OF
PROTECTION
provides
peace
of
mind
that
your
connected
equipment
is
safe.
When
all
lights
are
blue,
you
can
rest
assured
that
your
electronics
are
protected.
1.
PROTECTED
BLUE
indicates
that
the
POWER360
is
functioning
properly
and
that
all
connected
equipment
is
protected.
OFF
indicates
that
the
power
is
disconnected
from
the
outlets.
If
this
light
is
OFF
and
the
VOLTAGE
light
is
illuminated
BLUE,
then
the
PROTECT
OR
DISCONNECT
feature
in
your
POWER360
has
protected
your
equipment
from
a
catastrophic
surge
event
and
disconnected
power.
Unplug
all
electronics
from
your
POWER360
and
contact
Panamax
Tech
Support
for
assistance.
2.WIRING
BLUE
indicates
that
the
wall
outlet
is
properly
wired
and
grounded.
RED
indicates
an
open
ground
(no
ground
wire)
or
reverse
wiring
(polarity)
condition
is
detected.
Unplug
all
electronics
from
your
POWER360
and
contact
Panamax
Tech
Support
for
assistance.
3.VOLTAGE
BLUE
indicates
that
incoming
voltage
is
within
a
safe
range.
RED
indicates
an
over-voltage
or
brownout
condition
and
that
POWER360
has
disconnected
power
to
connected
equipment
to
keep
it
safe.
POWER360
will
automatically
reset
when
voltage
is
back
within
a
safe
range.
If
condition
persists,
it
is
advisable
to
contact
an
electrician
or
your
power
company
to
determine
the
cause
of
the
abnormal
voltage
issue.
Installation
NOTE
to
TV
ANTENNA,
SATELLITE
DISH
and
CATV
INSTALLERS:
Articles
810.21
and
820.40
of
the
NEC
provide
specific
guidelines
for
proper
grounding,
and
in
particular,
specify
that
the
cable
ground
shall
be
connected
to
the
grounding
system
of
the
building,
as
close
to
the
point
of
cable
entry
as
practical.
Installing
(AC
Power):
1.
Turn
OFF
the
power
to
all
equipment
that
will
be
plugged
into
the
unit.
2.
Make
sure
that
the
ON/OFF
switch
is
in
the
OFF
position.
Plug
the
unit
into
the
wall
outlet
and
then
turn
it
ON.
3.
Verify
that
the
"Wiring"
LED
is
BLUE,
indicating
that
the
wall
outlet
is
properly
wired.
4.
Plug
the
equipment
to
be
protected
into
the
POWER360
unit
and,
one
at
a
time,
turn
each
piece
of
connected
equipment
ON
and
check
for
correct
operation.
S.
Turn
OFF
the
unit
and
all
connected
equipment
before
connecting
any
signal
lines.
Installing
(Telephone Lines):
(Note:
Telephone
patch
cables
not
included)
IMPORTANT:
Note
the
position
of
the
IN
and
OUT
jacks
on
the
POWER360
unit.
IN
is
for
the
line
connection
that
comes
from
the
wall
or
floor
jack.
OUT
is
for
the
line
connection
to
your
connected
equipment.
The
protection
circuit
will
only
function
if
connected
properly.
Reversed
connections
will
pass
the
signal
to
the
connected
equipment
but
will
also
prevent
the
protection·
circuitry
from
working
and
will
invalidate
the
Panamax
Connected
Equipment
Protection
Policy.
1.
Make
sure
the
POWER360
and
all
connected
equipment
is
turned
OFF.
2.
Take
the
incoming
telephone
line
and
plug
it
into
the
appropriate
IN
jack
on
the
protector.
The
line
should
now
be
connected
between
the
wall
and
the
POWER360
unit.
3.
Plug
a
telephone
line
(not
included)
into
the
OUT
jack
and
then
plug
the
other
end
into
the
equipment
to
be
protected.
4.
Turn
On
the
protector
and
the
connected
equipment.
Verify
that
each
piece
of
connected
equipment
is
receiving
power
and
signal.
Installing
(Coaxial Lines):
(Coaxial
patch
cables
not
included)
Note
the
position
ofthe
IN
and
OUT
jacks
on
the
POWER360
unit.
IN
is
for
the
line
connection
that
comes
from
the
wall
or
floor
jack.
OUT
is
for
the
line
connection
to
your
connected
equipment.
The
POWER360
coaxial
protection
circuits
achieve
optimum
signal
quality
from
Panamax's
coaxial
protectors
that
have
the
smallest
signal
loss
on
the
market
-less
than
O.SdB
of
attenuation
from
OMHz
to
2.2GHz.
Our
coaxial
protection
has
been
specifically
designed
to
virtually
eliminate
signal
loss
to
ensure
HD
video
and
high
speed
internet
performance
is
not
compromised.
The
clamping
level
·of
75
volts
will
meetthe
demands
of
both
cable
and
satellite
voltage
while
minimizing
exposure
to
spikes
and
surges.
NOTE:
The
CATV/Sat/Antenna
protection
circuit
in
these
models
is
bi-directional
and
has
been
designed
to
work
with
cable
TV
systems
that
send
pay-per-view
ordering
information
to
the
cable
company
over
the
coaxial
line.
Make
sure
that
your
equipment
is
connected
to
the
proper
jacks.
When
used
with
diplexers,
this
protection
circuit
must
be
placed
between
the
diplexer
and
the
Satellite
receiver;
it
will
not
protect
the
diplexer.
1.
Make
sure
the
Panamax
protector
and
all
connected
equipment
is
turned
OFF.
2.
Connect
the
coaxial
cable
from
the
CATV
system,
antenna,
or
Satellite
dish
to
the
appropriate
LINE
connector
on
the
POWER360.
3.
Connect
a
coaxial
cable
from
the
EQUIP
jack
on
the
protector
to
appropriate
input
jack
on
your
TV,
cable
modem
or
Satellite
receiver.
USB
Charging
Station:
Your
POWER360
includes
two
modular
dual-port
charging
stations.
The
unique,
patent-pending
design
ofthese
charging
stations
allows
them
to
be
removed
from
the
base
unit
and
placed
on
a
nearby
desk
or
table
top
for
easy
access.
The
charging
station
must
be
tethered
to,
or
plugged
directly
into,
your
base
unit
to
charge.
A
6'
tether
cable
is
included
for
each
charging
station.
If
you
require
a
longer
cable,
various
lengths
of
standard
USB-to-Micro
USB
cables
are
commonly
available.
Rubber
feet
are
included
for
your
charging
stations.
Applied
on
the
bottom
and
towards
the
front
of
your
charging
station,
they
will
help
keep
your
charging
stations
in
place.
Each
charging
station
can
handle
up
to
2.1A
capacity,
typically
enough
for
2
mobile
devices
or
1
tablet.
The
USB
charging
ports
are
surge-protected.
Wall
Mounting:
Your
POWER360
may
be
affixed
to
a
wall
or
other
flat
surface.
1.
Determine
the
mounting
location.
Hold
the
POWER360
unit
up
against
the
location
and
mark
drilling
positions
using
the
mounting
guides
on
the
sides
of
the
unit.
Note:
You
are
marking
the
center
point
where
you
would
like
the
unit
to
be
mounted.
2.
Drive
a
#6
screw
into
each
drilling
position.leave
approximately
1/8"
of
space
between
the
back
of
the
screw
head
and
the
wall.
3.
Position
the
POWER360
over
the
two
screws
and
slide
down
to
lock
into
place.
4.
Using
the
above
procedure
allows
easy
removal
of
the
unit
by
sliding
up
to
disengage
the
unit
from
the
screws.
Troubleshooting
The
CIRCLE
OF
PROTECTION
is
not
lit,
there
is
no
AC
power
to
my
equipment,
or
my
equipment
doesn't
turn
on.
-Make
sure
POWER360
is
plugged
into
a
working
AC
outlet.
-Verify
the
"VOLTAGE"
indicator
on
the
CIRCLE
OF
PROTECTION
is
Blue.
If
Red,
the
incoming
line
voltage
is
either
too
high
or
too
low
and
has
been
disconnected
from
your
connected
equipment.
-Make
sure
the
switch/circuit
breaker
is
in
the
ON
position.
-
If
you
still
have
no
power,
POWER360
may
be
damaged.
Contact
Panamax
Tech
Support.
My
mobile
device
is
not
charging.
-
Some
devices
may
be
incompatible
with
this
USB
charging
port.
Although
the
device
may
report
that
it
is
not
charging,
it
is
most
likely
to
be
charging
at
a
lower
(0.5
Amp)
current.
-
When
charging
two
devices
it
is
possible
that
that
USB
charging
circuitry
may
be
overloaded.
Disconnect
one
of
the
devices.
-
Make
sure
the
tether
cable
is
connected
between
the
charging
station
and
base
unit,
or
the
charging
station
is
completely
plugged
into
the
base
unit.
There
is
no
audio
or
video
from
my
cable
box
and/or
my
cable
modem
Is
not
connecting.
-Check
the
coaxial
connections,
making
sure
they
are
correctly
and
securely
installed.
-Try
a
different
coaxial
cable.
-
Bypass
the
coaxial
connectors.
If
your
picture
returns,
the
protector
is
damaged.
Contact
Panamax
(website
or
Tech
Support
Department)
for
replacement.
-
If
you
still
have
no
picture,
a
problem
with
your
cable
provider's
signal
may
exist.
(Note:
Coaxial
patch
cables
not
included)
My
telephone,
DSL
modem
or
fax
machine
has
AC
power
but
still
does
not
work.
-Check
to
see
if
your
connected
equipment
is
receiving
a
dial
tone.
-Try
a
different
telephone
cable,
or
try
the
equipment
with
a
different
telephone
jack.
-
Bypass
the
telephone
connectors.
If
your
dial
tone
returns,
the
protector
is
damaged.
Contact
Panamax
(website
or
Tech
Support
Department)
for
replacement.
-
If
you
still
have
no
dial
tone,
a
problem
with
the
phone
company's
lines
may
exist.
The
Panamax
circuit
breaker
disconnects
AC
power
from
the
connected
equipment.
-
You
have
exceeded
the
ampere
rating
for
your
surge
protector.
As
a
temporary
fix,
disconnect
one
or
more
pieces
of
equipment.
Ask
your
Panamax
dealer
about
additional
Panamax
protectors
that
may
be
required.
PANAMAX
TECH
SUPPORT:
1-800-472-5555
www.panamax.com/POWER360
Warranty and Connected Equipment Policy Information
CAUTION!
All
Panamax
Warranties
and
Connected
Equipment
Policies
are
valid
only
in
the
United
States
and
Canada.
CAUTION!
Audio/Video,
computer
and/or
telephone
system
installations
can
be
very
complex
systems,
consisting
of
many
interconnected
components.
Due
to
the
nature
of
electricity
and
surges,
a
single
protector
may
not
be
able
to
completely
protect
complex
installations
.
In
those
cases,
a
systematic
approach
using
multiple
protectors
must
be
employed.
Systematic
protection
requires
professional
design.
AC
power,
satellite
cables,
CATV
cables,
telephone/network
lines,
signal
lines
or
any
other
electrical
conductors,
entering
the
system
that
do
not
pass
through
this
surge
protector
may
invalidate
the
Panamax
Connected
Equipment
Protection
Policy.
For
additional
information
on
how
to
protect
your
system,
please
contact
Panamax
before
connecting
your
equipment
to
the
surge
protector.
CAUTION!
WARRANTY
LIMITATION
FOR
INTERNET
PURCHASERS
Panamax
products
purchased
through
the
Internet
do
not
carry
a
valid
Product
Warranty
or
Connected
Equipment
Protection
Policy
unless
purchased
from
an
Authorized
Pan
a
max
Internet
Dealer
and
the
original
factory
serial
numbers
are
intact
(they
must
not
have
been
removed,
defaced
or
replaced
in
any
way).
Purchasing
from
an
Authorized
Panamax
Internet
Dealer
insures
that
the
P.roduct
was
intended
for
consumer
use,
has
passed
all
quality
inspections
and
is
safe.
Buying
through
auction
sites
or
unauthorized
dealers
may
result
in
the
purchase
of
salvaged,
failed
and/or
products
not
intended
for
use
in
the
US.
In
addition,
Authorized
Panamax
Internet
dealers
have
demonstrated
sufficient
expertise
to
insure
warranty
compliant
installations.
For
a
list
of
Authorized
Panamax
Internet
Dealers
go
to
www.panamax.com.lf
you
have
any
questions
regarding
these
requirements,
please
contact
Panamax
Tech
Support.
Product
Upgrade
Program
If
your
Panamax
power
conditioner
sacrifices
itself
while
protecting
your
connected
equipment,
you
have
an
option
to
upgrade
to
the
latest
technology
.
Please
go
to
our
web
site
www.panamax.com
or
contact
Panamax
Tech
Support
at
800-472-5555
for
details.
Panamax
Surge
Protector
Lifetime
Limited
Product
Warranty
Panamax
warrants
to
the
purchaser
of
any
standard
Panamax
surge
protector
that
the
surge
protector
shall
be
free
of
defects
in
design,
material,
or
workmanship,
and
Panamax
will
repair
or
replace
any
defective
unit.
For
product
replacement
see
"NOTIFICATION"
(3)
.
Panamax
Surge
Protector
Limited
Connected
Equipment
Protection
Policy
It
is
the
policy
of
Panamax
that
it
will,
at
its
election,
either
replace,
pay
to
replace
at
fair
market
value,
or
pay
to
repair,
up
to
the
dollar
amount
specified
below,
equipment
that
is
damaged
by
an
AC
power,
cable,
telephone,
or
lightning
surge
while
connected
to
a
properly
installed
Panamax
power
conditioner.
To
be
eligible
for
compensation,
repair
and
or
replacement,
the
power
conditioner
must
shows
signs
of
surge
damage
or
that
it
is
operating
outside
of
design
specifications,
relative
to
its
surge
protection
ca
·
pability,
and
under
all
of
the
circumstances
failed
to
protect
your
connected
equipment.
$500,000
CONNECTED
EQUIPMENT
POLICY
THE
CONNECTED
EQUIPMENT
POLICY
IS
SUBJECT
TO
THE
FOLLOWING
CONDITIONS
AND
LIMITATIONS
1.
ORIGINAL
OWNERSHIP
REQUIREMENT:
Panamax's
connected
equipment
policy
extends
to
the
original
purchaser
of
the
Panamax
product
only
and
is
non-transferable.
Original
purchase
receipts
must
accompany
any
product
return
or
claim
for
connected
equipment
damage.
2.
PROPER
INSTALLATION:
Panamax
AC
protectors
must
be
directly
plugged
into
a
properly
grounded
3-wire
AC
outlet.
Extension
cords*,
non-grounded
two
prong
adapters,
or
other
non
-
Panamax
surge
products
must
not
be
used
.
Building
wiring
and
other
connections
to
protected
equipment
must
conform
to
applicable
codes
(NEC
or
CEC}
.
No
other
ground
wires
or
ground
connections
may
be
used.
All
wires
(including,
e.g
.,
AC
power
lines,
telephone
lines,
signal/data
lines,
coaxial
cable,
antenna
lead-ins)
leading
into
the
protected
equipment
must
first
pass
through
a
single
Panamax
protector
designed
for
the
particular
application.
The
protector
and
the
equipment
to
be
protected
must
be
indoors
in
a
dry
location,
and
in
the
same
building
.
Pan
a
max
installation
instructions
and
diagrams
must
be
followed
3.
NOTIFICATION:
You
must
notify
Panamax
within
ten
days
of
any
event
precipitating
request
for
product
replacement
or
payment
for
connected
equipment
damage.
A
return
authorization
(RA)
number
must
first
be
obtained
from
the
Panamax
Tech
Support
Department
at
www.panamax.com**
before
returning
the
protector
Panamax
.
At
this
time,
you
must
notify
Panamax
if
you
believe
you
have
a
claim
for
damaged
connected
equipment.
Once
you
obtain
an
RA
number,
please
mark
the
number
on
the
bottom
of
the
unit
and
pack
it
in
a
shipping
carton/
box
with
enough
packing
material
to
protect
it
during
transit.
The
RA
number
must
also
be
clearly
marked
on
the
outside
of
the
carton.
Ship
the
unit
Panamax.
Please
note
that
you
are
responsible
for
any
and
all
charges
related
to
shipping
the
unit
to
Panamax.
If
connected
equipment
damage
was
indicated
on
your
RA
request,
Panamax
will
mail
you
claim
kit
to
be
completed
and
returned
within
30
days
.A
connection
diagram
of
your
system
will
be
required
as
part
of
the
claim
kit.
Be
sure
to
note
its
configuration
before
disconnecting
your
equipment.
4.
DETERMINATION
OF
FAILURE:
Panamax
will
evaluate
the
protector
for
surge
damage
.
The
Panamax
protector
must
show
signs
of
surge
damage
or
must
be
performing
outside
(>
10%)
of
design
specifications
relative
to
its
surge
protection
capability.
Opening
the
enclosure,
tampering
with,
or
modifying
the
unit
in
any
way
shall
be
grounds
for
an
automatic
denial
your
request
for
payment.
Panamax
,
after
evaluating
all
information
provided,
will
determine
whether
or
not
your
request
is
eligible
for
payment.
If
the
surge
protector
shows
no
signs
of
AC
power
or
signal
line
surge
damage
and
is
working
within
design
specifications,
Panamax
will
return
the
unit
to
you
with
a
letter
explaining
the
test
results
and
notifying
you
of
the
rejection
your
claim
.
Exceptions
:
If
a
dealer
or
installer
replaces
the
protector
for
the
customer,
replacement
will
be
returned
to
the
dealer
installer;
or
if
the
protector
is
a
pre-1996
model,
it
will
be
replaced;
or,
for
a
Canadian
customer,
the
protector
will
be
replaced.
Panamax
reserves
the
right
to
inspect
the
damaged
connected
equipment,
parts,
or
circuit
boards.
Please
note
that
you
are
responsible
for
any
and
all
charges
related
to
shipping
the
damaged
equipment
to
Panamax.
Panamax
also
reserves
the
right
to
inspect
the
customer
's
facility
.
Damaged
equipment
deemed
uneconomical
to
repair
must
remain
available
for
inspection
by
Panamax
until
the
claim
is
finalized
.
S.
REQUEST
PAYMENTS:
Once
Panamax
has
determined
that
you
are
entitled
to
compensation,
Panamax
will,
at
its
election,
either
pay
you
the
present
fair
market
value
of
the
damaged
equipment,
or
pay
for
the
cost
of
the
repair,
or
send
you
replacement
equipment,
or
pay
the
equivalence
of
replacement
equipment.
6.
OTHER
INSURANCE/WARRANTIES:
This
coverage
is
secondary
to
any
existing
manufacturer's
warranty
,
implied
or
expressed,
or
any
insurance
and/or
service
contract
that
may
cover
the
loss
.
7.
EXCLUSIONS:
THE
PANAMAX
CONNECTED
EQUIPMENT
PROTECTION
POLICY
DOES
NOT
APPLYTO:
Service
charges,
installation
costs,
reinstallation
costs
;
setup
cost;
diagnostic
charges;
periodic
checkups;
routine
maintenance;
loss
of
use
of
the
product;
costs
or
expenses
arising
out
of
reprogramm
i
ng
or
loss
of
programming
and/or
data;
shipping
charges
or
fees;
service
calls;
loss
or
damage
occasioned
by
fire,
theft,
flood,
wind,
accident
,
abuse
or
misuse,
and
products
subject
to
manufacturer's
recall
or
similar
event.
8.
DISPUTE
RESOLUTION:
Any
controversy
or
claim
arising
out
ofor
relating
to
Panamax
's
Connected
Equipment
Protection
Policy,
or
the
alleged
breach
thereof,
shall
be
settled
by
arbitration
administered
by
the
American
Arbitration
Association
under
its
Commercial
Arbitration
Rules
.
You
may
file
for
arbitration
at
a
ny
AAA
location
in
the
United
States
upon
the
payment
of
the
applicable
filing
fee.
The
arbitration
will
be
conducted
before
a
single
arbitrator
,
and
will
be
limited
solely
to
the
dispute
or
controversy
between
you
and
Panamax.
The
arbitration
shall
be
held
in
any
mutually
agreed
upon
location
in
person,
by
telephone,
or
online.
Any
decision
rendered
in
such
arbitration
proceedings
will
be
final
and
binding
on
each
of
the
parties,
and
judgment
may
be
entered
thereon
in
a
court
of
competent
jurisdiction.
The
arbitrator
shall
not
award
either
party
special,
exemplary,
consequential,
punitive,
incidental
or
indirect
damages,
or
attorney
's
fees.
The
parties
will
share
the
costs
of
arbitration
(including
the
arbitrator's
fees,
if
any)
in
the
proportion
that
the
final
award
bears
to
the
amount
of
the
initial
claim.
9.GENERAL:
If
you
have
any
questions
regarding
the
product
warranty
or
the
connected
equipment
protection
policy,
please
contact
the
Panamax
Tech
Support
Department
at
www.panamax.com.
The
limited
Product
Warranty
and
Connected
Equipment
Policy
herein
supersede
all
previous
warranties
and/or
Connected
Equipment
repair/replacement
policies.
THE
LIMITED
PRODUCT
WARRANTY
IS
THE
ONLY
WARRANTY
PROVIDED
WITH
THIS
PANAMAX
PRODUCT
AND
ANY
OTHER
IMPLIED
OR
EXPRESSED
WARRANTIES
ARE
NON
-
EXISTENT;
This
warranty
may
not
be
modified
except
in
writing,
signed
by
an
officer
of
the
Pan
a
max
Corporation
.
*The
use
of
a
Panamax
extension
cord
or
equivalent
(Ul
orCSA
listed,
minimum
14AWG,
3-
wiregrounded)
will
not
invalidate
the
warranty.
**
Forms
are
available
on
the
Panamax
web
site
for
requesting
RAs
and
opening
a
claim
for
connected
equipment
damage.
POWER
60
TM
Circle
of
Protection
PANAMAX
TECH
SUPPORT:
1-
800-472-5555
www.panamax;com/POWER360
CABlEADO
CABlAGE
02014
(Ott
Brands,
LLC.
All
rights
reserved.
Panamax•
and
POWER360'"
are
ft9lslmd
trademarts
of
Core
Btands
,
LlC.
Designed
and
Engin
e
ered
in
the
USA.
Minufactured
to
Panamax
quaiUy
spe<lfications
In
China
.
TENSION

Other Panamax Surge Protector manuals

Panamax PM8-EX User manual

Panamax

Panamax PM8-EX User manual

Panamax M8-AV User manual

Panamax

Panamax M8-AV User manual

Panamax MAX 4310 User manual

Panamax

Panamax MAX 4310 User manual

Panamax PM8-AV User manual

Panamax

Panamax PM8-AV User manual

Panamax M2SUB User manual

Panamax

Panamax M2SUB User manual

Panamax MOD-AT2 User manual

Panamax

Panamax MOD-AT2 User manual

Panamax M4320-PRO User manual

Panamax

Panamax M4320-PRO User manual

Panamax M8-AV-PRO User manual

Panamax

Panamax M8-AV-PRO User manual

Panamax PF Power Max-In-Wall MIW-SURGE-1G User manual

Panamax

Panamax PF Power Max-In-Wall MIW-SURGE-1G User manual

Panamax MIP-15LT User manual

Panamax

Panamax MIP-15LT User manual

Panamax MAX(R) 4300-PM User manual

Panamax

Panamax MAX(R) 4300-PM User manual

Panamax MIW-XT User manual

Panamax

Panamax MIW-XT User manual

Panamax MAX 5100-PM User manual

Panamax

Panamax MAX 5100-PM User manual

Panamax MFP-300 User manual

Panamax

Panamax MFP-300 User manual

Panamax MFP500-EX User manual

Panamax

Panamax MFP500-EX User manual

Panamax PFPower MIW-SURGE-1G User manual

Panamax

Panamax PFPower MIW-SURGE-1G User manual

Panamax MFP-300 User manual

Panamax

Panamax MFP-300 User manual

Panamax M4315-PRO User manual

Panamax

Panamax M4315-PRO User manual

Panamax MIW-XT User manual

Panamax

Panamax MIW-XT User manual

Panamax M8-HT-PRO User manual

Panamax

Panamax M8-HT-PRO User manual

Panamax MAX 5410 User manual

Panamax

Panamax MAX 5410 User manual

Panamax MAX 4400 User manual

Panamax

Panamax MAX 4400 User manual

Panamax ML4200 User manual

Panamax

Panamax ML4200 User manual

Panamax PFPower MIW-SURGE-1G User manual

Panamax

Panamax PFPower MIW-SURGE-1G User manual

Popular Surge Protector manuals by other brands

Siemens 3EL2 operating instructions

Siemens

Siemens 3EL2 operating instructions

P3 International Kill A Watt PS operating manual

P3 International

P3 International Kill A Watt PS operating manual

Philips SPP1182WC Specifications

Philips

Philips SPP1182WC Specifications

Ilsco SSI SpecPRO CRM 22 Series manual

Ilsco

Ilsco SSI SpecPRO CRM 22 Series manual

Intermatic AG2083C3 installation instructions

Intermatic

Intermatic AG2083C3 installation instructions

Ditek D200-2403D Install instructions

Ditek

Ditek D200-2403D Install instructions

Tripp Lite tmc-6 Specifications

Tripp Lite

Tripp Lite tmc-6 Specifications

QVS PP135 Specification sheet

QVS

QVS PP135 Specification sheet

CyberPower P6WSUC user manual

CyberPower

CyberPower P6WSUC user manual

Emerson Liebert TYPE SS Specification sheet

Emerson

Emerson Liebert TYPE SS Specification sheet

Uniteck UNISPLIT 160.12 instruction manual

Uniteck

Uniteck UNISPLIT 160.12 instruction manual

Ametek Surgex SX1200 Series installation instructions

Ametek

Ametek Surgex SX1200 Series installation instructions

Gembird SIS-TUV user manual

Gembird

Gembird SIS-TUV user manual

CyberPower HT1006U user manual

CyberPower

CyberPower HT1006U user manual

Emos LGEU-1 instruction manual

Emos

Emos LGEU-1 instruction manual

Embertec EmberCeptor PC user manual

Embertec

Embertec EmberCeptor PC user manual

Emerson 500 Series Installation, operation and maintenance manual

Emerson

Emerson 500 Series Installation, operation and maintenance manual

M-system MD7LC instruction manual

M-system

M-system MD7LC instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.