manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Panamax
  6. •
  7. Surge Protector
  8. •
  9. Panamax M8-AV-PRO User manual

Panamax M8-AV-PRO User manual

M8-AV-PRO
AC power, telephone and coax lines can provide direct pathways for surges
and spikes to enter and damage expensive audio/video equipment.
M8-AV-PRO eliminates voltage irregularities & protects your AV system.
M8-AV-PRO
The M8-AV-PRO’s Power Cleaning and Premium
Filtration eliminate common symptoms of
contaminated power (including loss of detail,
hisses, hums and visual artifacts) and allows your
A/V equipment to perform up to its full capability.
L629-B 11/09
Panamax’s patented AVM circuitry continuously
monitors the incoming line voltage and disconnects
your equipment in the event of an over voltage or
undervoltage (brownout). Power is automatically
reconnected when voltage returns to a safe level,
eliminating service calls or system downtime
MONITORS INCOMING LINE VOLTAGE
IMPROVES PICTURE & SOUND QUALITY
1
2
www.panamax.com
Lifetime Product
Warranty*
Product Upgrade Policy*
$5,000,000 Limited
Connected Equipment
Protection Policy*
*See actual warranty documentation.
HD Flat Panel
Display Systems
(Plasma, LCD, CRT’s
and Receivers)
SPECIFICALLY DESIGNED AND
ENGINEERED TO PROTECT:
MODEL NO.
M8-AV-PRO
HOME THEATER POWER MANAGEMENT
The M8-AV-PRO is designed to provide noise isolation between the
two isolated outlet banks so that any noise created by an A/V
component in one bank cannot contaminate the power to
the equipment that is plugged into the other outlet bank.
REDUCES CROSS-CONTAMINATION BETWEEN COMPONENTS
3
Protects equipment from electrical
surges that travel over telephone
lines.
Protects equipment from electrical
surges that travel over cable,
satellite and antenna lines.
Exclusive Protect or
Disconnect™ circuitry.
Hi-Def Designed to work with
your High Definition system.
More outlets for all of your
power needs.
Cable/Sat Protection
Telephone line protection
Surge Protection
Eight Outlets
Hi Def Ready
8
Automatic Voltage Monitoring
AVM
Improves Picture & Sound. Provides
clean power by filtering out noise
common to household power.
Premium Filtration
12
V
12 Volt Trigger
Allows source equipment to activate
or deactivate outlets 5-8 on the
M8-HT-PRO.
© 2009 Panamax Inc. Panamax and the Panamax logo are registered US trademarks of Panamax.
Engineered and built to meet the latest UL
Safety requirements (UL 1449 3rd Edition)
M8-AV-PRO
L629-B 11/09
FEATURES
www.panamax.com
HOME THEATER POWER MANAGEMENT
Power ON/Protection OK LED
(green) Normally ON; indicates
that the surge protector is
functioning properly and that all
connected equipment is protected.
Ground OK LED
(green) Normally ON; indicates
that the wall outlet is properly
wired and grounded.
CATV / Satellite Connectors
2 sets of IN /OUT,
universal coaxial
connectors
8 ft. AC Power Cord
Right Angle with
45 Degree Offset Plug
8 AC Outlets
Outlets 1-4 feature (4 top outlets)
“Balanced Double L” Filtration Circuit
Outlets 5-8 (4 side outlets) for high
current equipment.
ON / OFF Power Switch and
Circuit Breaker Combination
1
2
Accepts Panamax add on data line protection modules
(modules sold separately).
SPECIFICATIONS
Design and specifications subject to
change without notice due to product
upgrades and improvements.
UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
Dimensions Weight Dimensions Weight UPC Qty. Dimensions Weight UPC
12” x 5” x 1.75” 3.5 lbs 13.25” x 9.5” x 2.5” 4 Lbs 0 50616 00874 7 6 17.25” x 8.5” x 14” 25 Lbs 50 050616 00874 2
MODEL M8-AV-PRO SINGLE UNIT CARTON MASTER CARTON
1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 or 707-283-5900 • Fax 707-283-5901
(12.5 in. L Including brackets)
Accessory Included:
3 ft. Coax Cable Mounting Brackets
In/Out Telco/LAN Connectors
Telco and LAN Connector RJ-45
Unsafe Voltage LED (red) Normally OFF;
flashes when lit, indicates that incoming
voltages are unsafe and the surge protector
has disconnected the power to
connected equipment.
AC POWER
Protect or Disconnect™ Circuitry___________________Yes
Patented Power Management Circuit*________________Yes
Auto-resetting Overvoltage Shutoff_____________ 144V ±8V
Auto-resetting Undervoltage Shutoff_____________90V ±6V
Thermal Fusing______________________________ Yes
Line Voltage_______________________120VAC, 50/60Hz
Initial Clamping Level_____________200V Peak, 141V RMS
Voltage Protection Rating (UL 1449 3rd Edition, 3,000A)_________500V
UL 991____________________________________Yes
Protection Modes_____________________L-N, L-G, N-G
Maximum Current Rating_________________15A (1800W)
Single Pulse Energy Dissipation_____________1875 Joules
Peak Impulse Current______________________ 65,000 A
DC Trigger
For high current
outlets (5-8)
DC Trigger LED
(green) ON/OFF status depends upon
whether or not a 12VDC signal is being
received from another component
when utilizing.
LAN Protection:
Compatibility____________________________10/100bT
Clamping Level_______________________________7V
Suppression Modes________Differential & Common Ground
Wires Protected_____________________Pins 1, 2, 3, & 6
Connectors___________________RJ-45 Shared with Telco
Telco Protection:
Fuseless/Auto-Resetting________________________Yes
Clamping Level_____________________________260V
Capacitance_________________________30 pf (approx.)
Suppression Modes_____________Metallic & Longitudinal
Wires Protected____________________2 wire, 1 pair (4,5)
Connectors___________________ RJ-45 Shared with LAN
EMI/RFI Noise Filtration__________53dB (100kHz – 1 MHz)
Number of Isolated Banks of Outlets__________________2
Filter Circuits_______1 Common Mode
1 Normal Mode,
1 High-Current Inductorless
Filtered Outlet Banks____________53 dB (100 KHz - 1 MHz)
High-Current Outlets____________50 dB (100 KHz - 1 MHz)
Response Time_____________________________ < 1 n
Universal Coax Protection:
HD Ready__________________________________Yes
Shielded___________________________________Yes
Clamping Level______________________________75V
Frequency Range_____________________ 5MHz - 2.GHz
Insertion Loss____________________________ <0.5dB
Connections__________________Female "F", Gold Plated
Bi-Directional______________________________ Yes

Other Panamax Surge Protector manuals

Panamax MIP-15LT User manual

Panamax

Panamax MIP-15LT User manual

Panamax SP8-AV User manual

Panamax

Panamax SP8-AV User manual

Panamax MFP-400 User manual

Panamax

Panamax MFP-400 User manual

Panamax MD2-RCA User manual

Panamax

Panamax MD2-RCA User manual

Panamax PM8-HT User manual

Panamax

Panamax PM8-HT User manual

Panamax MIW-SURGE User manual

Panamax

Panamax MIW-SURGE User manual

Panamax MIW-VGA User manual

Panamax

Panamax MIW-VGA User manual

Panamax MX5102 User manual

Panamax

Panamax MX5102 User manual

Panamax M8-HT User manual

Panamax

Panamax M8-HT User manual

Panamax M4310 User manual

Panamax

Panamax M4310 User manual

Panamax M8-AV-PRO User manual

Panamax

Panamax M8-AV-PRO User manual

Panamax MFP-400 User manual

Panamax

Panamax MFP-400 User manual

Panamax MAX 5300-PM User manual

Panamax

Panamax MAX 5300-PM User manual

Panamax MAX 5510 ACRegenerator User manual

Panamax

Panamax MAX 5510 ACRegenerator User manual

Panamax MOD-UTP5e User manual

Panamax

Panamax MOD-UTP5e User manual

Panamax MIW-SURGE User manual

Panamax

Panamax MIW-SURGE User manual

Panamax MR4300 User manual

Panamax

Panamax MR4300 User manual

Panamax M8-AV User manual

Panamax

Panamax M8-AV User manual

Panamax MX5102 User manual

Panamax

Panamax MX5102 User manual

Panamax PF Power Max-In-Wall MIW-SURGE-1G User manual

Panamax

Panamax PF Power Max-In-Wall MIW-SURGE-1G User manual

Panamax MOD-AT2 User manual

Panamax

Panamax MOD-AT2 User manual

Panamax M8C-PRO User manual

Panamax

Panamax M8C-PRO User manual

Panamax PM8-EX User manual

Panamax

Panamax PM8-EX User manual

Panamax In-Wall Home Theater Power Management User manual

Panamax

Panamax In-Wall Home Theater Power Management User manual

Popular Surge Protector manuals by other brands

AMAZON COMMERCIAL B082Q22W9L manual

AMAZON COMMERCIAL

AMAZON COMMERCIAL B082Q22W9L manual

QVS Power Protection PP145C Specifications

QVS

QVS Power Protection PP145C Specifications

MTL ZoneDefender PRO Series Installation & user manual

MTL

MTL ZoneDefender PRO Series Installation & user manual

Black Box SP077A manual

Black Box

Black Box SP077A manual

Tripp Lite TLP808TELTV Specifications

Tripp Lite

Tripp Lite TLP808TELTV Specifications

Tripp Lite VR1208R owner's manual

Tripp Lite

Tripp Lite VR1208R owner's manual

Abus ITAC10210 user manual

Abus

Abus ITAC10210 user manual

Tripp Lite TRAVELCUBE Specifications

Tripp Lite

Tripp Lite TRAVELCUBE Specifications

Rocket Fish RF-HTS110 Guide d'installation rapide

Rocket Fish

Rocket Fish RF-HTS110 Guide d'installation rapide

Tripp Lite LC 1200 owner's manual

Tripp Lite

Tripp Lite LC 1200 owner's manual

Tripp Lite TLP51F Specifications

Tripp Lite

Tripp Lite TLP51F Specifications

Tripp Lite tmc-6 Specifications

Tripp Lite

Tripp Lite tmc-6 Specifications

FRO­NIUS SPD Installation instruction

FRO­NIUS

FRO­NIUS SPD Installation instruction

Tripp Lite DataShield 93-0163 installation guide

Tripp Lite

Tripp Lite DataShield 93-0163 installation guide

Rocket Fish RF-PCS12ES Quick setup guide

Rocket Fish

Rocket Fish RF-PCS12ES Quick setup guide

Tripp Lite TLP82F Specifications

Tripp Lite

Tripp Lite TLP82F Specifications

Tripp Lite SUPER5DEU Specification sheet

Tripp Lite

Tripp Lite SUPER5DEU Specification sheet

Omnimount OESP10 instruction manual

Omnimount

Omnimount OESP10 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.