This product is a sensor for detecting leak of
fluids.
When this product is used with safety devices,
construct the system such that the device itself
always operates in the safety side.
ە
ە
WARNING
SPECIFICATIONS
1
Incandescent light: 1,000 lx or less at the light-receiving face
Ambient illuminance Infrared LED (non-modulated)
Emitting element Enclosure: PFA
Material 0.1mm2 3-core PFA
cabtyre cable, 3m long 0.1mm2 3-core PFA
cabtyre cable, 5m long 0.1mm2 3-core PFA
cabtyre cable, 3m long 0.1mm2 3-core PFA
cabtyre cable, 5m long
Cable
IP67(IEC)
Protection -10 to +60Υ(No dew condensation or icing allowed) (Note 3, 4), Storage: -20 to +70Υ
Ambient temperature 35 to 85% RH, Storage: 5 to 85% RH
Ambient humidity
50ms or less
Response time Red LED (lights up when leak is detected or the sensor is mounted improperly.)
Abnormality indicator Green LED (lights up when the sensor is mounted properly.)
Normal indicator
ON when normal operation, OFF when leak is detected or the sensor is mounted improperly.
Output operation Incorporated
Short-circuit protection
࣭
࣭
࣭
<NPN output type>
NPN open-collector transister
Maximum sink current: 50mA
Applied voltage: 30V DC or less (between output and 0V)
Residual voltage: 1.0V or less (at 50mA sink current)
0.4V or less (at 16mA sink current)
<PNP output type>
PNP open-collector transister
࣭
࣭
࣭
Maximum source current: 50mA
Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1.0V or less (at 50mA source current)
0.4V or less (at 16mA source current)
Output
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note1, 2)
Sensing object
12 to 24V DC s10%ࠉRipple P-P 10% or less
Supply voltage 15mA or less
Current consumption
Type
Model
No.
NPN output type
PNP output type
PFA mounting bracket type (For screw-fixing)
PVC mounting bracket type (For adhesive-fixing)
EX-F61
EX-F61-PN
3m cable length type EX-F61-C5
EX-F61-PN-C5
5m cable length type EX-F62
EX-F62-PN
3m cable length type
Item EX-F62-C5
EX-F62-PN-C5
5m cable length type
60g approx. 80g approx. 60g approx. 80g approx.
Weight PFA mounting bracket: 1 pc. PVC mounting bracket: 1pc.
Accessories
Notes: 1)
2)
3)
4)
Highly viscous liquid may not be stably detected.
The agents mentioned above are examples. Further, PVC mounting bracket may not be used
depending on type or viscosity etc. of the agent. For details, please contact us.
Liquid being detected should be also kept within the rated ambient temperature range.
The specified ambient temperature is only for fixed product.
CAUTIONS
2
ە
ە
ە
ە
ە
ە
ە
ە
ە
ە
ە
This product has been developed / produced for industrial use only.
Avoid using the product in an explosive atmosphere because this
product does not have an explosive-proof protective construction.
Make sure to carry out the wiring in the power supply off condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if
an AC power supply is directly connected, the sensor may get burnt
or damaged.
If power is supplied from a commercial switching regulator, ensure that the
frame ground (F.G.) terminal of the power supply is connected to an actual
ground.
Do not use during the initial transient time (50m sec. approx.)
after the power supply is switched on.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
Cable extension is possible up to total 50m with 0.3mm2, or more, cable.
However, in order to reduce noise, make the wiring as short as possible.
Do not run the wires together with high-voltage lines or power lines or put
them in the same race way. This can cause malfunction due to induction.
In case a surge is generated in the used power supply, connect a
surge absoeber to the supply.
ە
ە
ە
ە
ە
ە
ە
ە
ە
Be sure to use the exclusive mounting bracket when installing the
sensor to avoid human error, etc. Reliable detection cannot be
guaranteed when this mounting bracket is not used.
Make sure to use an isolation transformer for the DC power supply. If
an auto-transformer (single winding transformer) is used, this product
or the power supply may get damaged.
In case air bubbles are drawn into the sensing part, take care that it may take
some time for sensing to stabilize, or sensing may even become unstable.
When liquid remains on the sensing surface after leak detection, wipe all
liquid from the sensing surface. To avoid scratching the sensing surface
and the enclosed mounting bracket, use a soft cloth.
If there is liquid remained or scratch on the sensing surface or the
exclsive mounting bracket, normal operation cannot be performed.
Since this sensor employs non-modulated infrared LED, take sufficient care against
extraneous light. Do not expose the sensing part directly to the extraneous light.
Avoid dust, dirt, and steam. Further, do not use this product where oil or
grease splashes to the product, or in an environment containing corrosive gas,
etc.
In case this sensor is used where electrostatic charge is present, use a
metal leak pan, which should be connected to an actual ground.
In case of using this product 50℃or more, be sure to fix this product with
a dedicated mounting bracket.
I/O CIRCUIT DIAGRAMS
4
ŪNPN output type
(Brown) +V
(Black) Output
(Blue) 0V
Load
㸩
㸫
12 to 24V DC
s10%
Internal circuit Users' circuit
50mA max.
Sensor circuit
Color code
ŪPNP output type
㸩
㸫
(Black) Output
(Blue) 0V Load
12 to 24V DC
s10%
Internal circuit Users' circuit
50mA max.
(Brown) +V
Color code
Sensor circuit
ەEX-F61š(Sensor with PFA mounting bracket)
ەEX-F62š(Sensor with PVC mounting bracket)
DIMENSIONS (Unit: mm)5
Fixing surface
314
19.25
Abnormality indicator
(red)
Normal indicator
(green)
21.5
26
27
PVC mounting bracket
314
19.25
Abnormality indicator
(red)
Normal indicator
(green)
2-ȭ4.2 4.5
17
PFA mounting bracket
Stainless steel bush
18
27
26
EX-F62š
ە
ە
Please note that if the excess adhesive from the bottom
surface of the exclusive mounting bracket is remained, the
sensing capability may be affected.
Use adhesive for polyvinyl chloride(PVC).
MOUNTING
3
How to fit the sensor body to the exclusive mounting bracket
ە
Align the projections in the sensor body with the notches of
the exclusive mounting bracket and slide till a click is felt.
Projection
Notches
How to remove the sensor body from the exclusive mounting bracket
ە
Pinch the projections of the sensor body and pull the body
upwards.
Never pull the cable, since it may cause a cable break.
Projection
EX-F61š
ەInsert the M4 stud-bolt
(length 10mm or more)
welded on the user's
facilities into the mounting
hole of the PFA mounting
bracket and screw with an
M4 nut (please arrange
separately). The tightening
torque should be 0.98N㺃m or
less.
M4 nut
M4 stud-bolt
(straight type)
1
INTENDED PRODUCTS FOR CE MARKING
6
ە
ە
The models listed under ' SPECIFICATIONS'
come with CE Marking.
As for all other models, please contact our office.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
Amplifier Built-in Leak Detection Sensor
EX-F60 Series
INSTRUCTION
MANUAL
http://panasonic.net/id/pidsx/global
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
PRINTED IN JAPAN
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com
MJEC-EXF60 No.0045-90V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly
for the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
This product is a sensor for detecting leak of
fluids.
When this product is used with safety devices,
construct the system such that the device itself
always operates in the safety side.
ە
ە
WARNING
SPECIFICATIONS
1
Incandescent light: 1,000 lx or less at the light-receiving face
Ambient illuminance Infrared LED (non-modulated)
Emitting element Enclosure: PFA
Material 0.1mm2 3-core PFA
cabtyre cable, 3m long 0.1mm2 3-core PFA
cabtyre cable, 5m long 0.1mm2 3-core PFA
cabtyre cable, 3m long 0.1mm2 3-core PFA
cabtyre cable, 5m long
Cable
IP67(IEC)
Protection -10 to +60Υ(No dew condensation or icing allowed) (Note 3, 4), Storage: -20 to +70Υ
Ambient temperature 35 to 85% RH, Storage: 5 to 85% RH
Ambient humidity
50ms or less
Response time Red LED (lights up when leak is detected or the sensor is mounted improperly.)
Abnormality indicator Green LED (lights up when the sensor is mounted properly.)
Normal indicator
ON when normal operation, OFF when leak is detected or the sensor is mounted improperly.
Output operation Incorporated
Short-circuit protection
࣭
࣭
࣭
<NPN output type>
NPN open-collector transister
Maximum sink current: 50mA
Applied voltage: 30V DC or less (between output and 0V)
Residual voltage: 1.0V or less (at 50mA sink current)
0.4V or less (at 16mA sink current)
<PNP output type>
PNP open-collector transister
࣭
࣭
࣭
Maximum source current: 50mA
Applied voltage: 30V DC or less (between output and +V)
Residual voltage: 1.0V or less (at 50mA source current)
0.4V or less (at 16mA source current)
Output
Agent, such as Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. (Note1, 2)
Sensing object
12 to 24V DC s10%ࠉRipple P-P 10% or less
Supply voltage 15mA or less
Current consumption
Type
Model
No.
NPN output type
PNP output type
PFA mounting bracket type (For screw-fixing)
PVC mounting bracket type (For adhesive-fixing)
EX-F61
EX-F61-PN
3m cable length type EX-F61-C5
EX-F61-PN-C5
5m cable length type EX-F62
EX-F62-PN
3m cable length type
Item EX-F62-C5
EX-F62-PN-C5
5m cable length type
60g approx. 80g approx. 60g approx. 80g approx.
Weight PFA mounting bracket: 1 pc. PVC mounting bracket: 1pc.
Accessories
Notes: 1)
2)
3)
4)
Highly viscous liquid may not be stably detected.
The agents mentioned above are examples. Further, PVC mounting bracket may not be used
depending on type or viscosity etc. of the agent. For details, please contact us.
Liquid being detected should be also kept within the rated ambient temperature range.
The specified ambient temperature is only for fixed product.
CAUTIONS
2
ە
ە
ە
ە
ە
ە
ە
ە
ە
ە
ە
This product has been developed / produced for industrial use only.
Avoid using the product in an explosive atmosphere because this
product does not have an explosive-proof protective construction.
Make sure to carry out the wiring in the power supply off condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if
an AC power supply is directly connected, the sensor may get burnt
or damaged.
If power is supplied from a commercial switching regulator, ensure that the
frame ground (F.G.) terminal of the power supply is connected to an actual
ground.
Do not use during the initial transient time (50m sec. approx.)
after the power supply is switched on.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the frame
ground (F.G.) terminal of the equipment to an actual ground.
Cable extension is possible up to total 50m with 0.3mm2, or more, cable.
However, in order to reduce noise, make the wiring as short as possible.
Do not run the wires together with high-voltage lines or power lines or put
them in the same race way. This can cause malfunction due to induction.
In case a surge is generated in the used power supply, connect a
surge absoeber to the supply.
ە
ە
ە
ە
ە
ە
ە
ە
ە
Be sure to use the exclusive mounting bracket when installing the
sensor to avoid human error, etc. Reliable detection cannot be
guaranteed when this mounting bracket is not used.
Make sure to use an isolation transformer for the DC power supply. If
an auto-transformer (single winding transformer) is used, this product
or the power supply may get damaged.
In case air bubbles are drawn into the sensing part, take care that it may take
some time for sensing to stabilize, or sensing may even become unstable.
When liquid remains on the sensing surface after leak detection, wipe all
liquid from the sensing surface. To avoid scratching the sensing surface
and the enclosed mounting bracket, use a soft cloth.
If there is liquid remained or scratch on the sensing surface or the
exclsive mounting bracket, normal operation cannot be performed.
Since this sensor employs non-modulated infrared LED, take sufficient care against
extraneous light. Do not expose the sensing part directly to the extraneous light.
Avoid dust, dirt, and steam. Further, do not use this product where oil or
grease splashes to the product, or in an environment containing corrosive gas,
etc.
In case this sensor is used where electrostatic charge is present, use a
metal leak pan, which should be connected to an actual ground.
In case of using this product 50℃or more, be sure to fix this product with
a dedicated mounting bracket.
I/O CIRCUIT DIAGRAMS
4
ŪNPN output type
(Brown) +V
(Black) Output
(Blue) 0V
Load
㸩
㸫
12 to 24V DC
s10%
Internal circuit Users' circuit
50mA max.
Sensor circuit
Color code
ŪPNP output type
㸩
㸫
(Black) Output
(Blue) 0V Load
12 to 24V DC
s10%
Internal circuit Users' circuit
50mA max.
(Brown) +V
Color code
Sensor circuit
ەEX-F61š(Sensor with PFA mounting bracket)
ەEX-F62š(Sensor with PVC mounting bracket)
DIMENSIONS (Unit: mm)5
Fixing surface
314
19.25
Abnormality indicator
(red)
Normal indicator
(green)
21.5
26
27
PVC mounting bracket
314
19.25
Abnormality indicator
(red)
Normal indicator
(green)
2-ȭ4.2 4.5
17
PFA mounting bracket
Stainless steel bush
18
27
26
EX-F62š
ە
ە
Please note that if the excess adhesive from the bottom
surface of the exclusive mounting bracket is remained, the
sensing capability may be affected.
Use adhesive for polyvinyl chloride(PVC).
MOUNTING
3
How to fit the sensor body to the exclusive mounting bracket
ە
Align the projections in the sensor body with the notches of
the exclusive mounting bracket and slide till a click is felt.
Projection
Notches
How to remove the sensor body from the exclusive mounting bracket
ە
Pinch the projections of the sensor body and pull the body
upwards.
Never pull the cable, since it may cause a cable break.
Projection
EX-F61š
ەInsert the M4 stud-bolt
(length 10mm or more)
welded on the user's
facilities into the mounting
hole of the PFA mounting
bracket and screw with an
M4 nut (please arrange
separately). The tightening
torque should be 0.98N㺃m or
less.
M4 nut
M4 stud-bolt
(straight type)
1
INTENDED PRODUCTS FOR CE MARKING
6
ە
ە
The models listed under ' SPECIFICATIONS'
come with CE Marking.
As for all other models, please contact our office.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
Amplifier Built-in Leak Detection Sensor
EX-F60 Series
INSTRUCTION
MANUAL
http://panasonic.net/id/pidsx/global
© Panasonic Industrial Devices SUNX Co., Ltd. 2014
PRINTED IN JAPAN
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
Ramco National
800-280-6933 | [email protected]
www.panasonicsensors.com

This manual suits for next models

8

Other Panasonic Accessories manuals

Panasonic MA3J745E User manual

Panasonic

Panasonic MA3J745E User manual

Panasonic WV-PB5504A User manual

Panasonic

Panasonic WV-PB5504A User manual

Panasonic MIR-H163-PA User manual

Panasonic

Panasonic MIR-H163-PA User manual

Panasonic MA22D28 User manual

Panasonic

Panasonic MA22D28 User manual

Panasonic AMGU4241 User manual

Panasonic

Panasonic AMGU4241 User manual

Panasonic ST4 Series User manual

Panasonic

Panasonic ST4 Series User manual

Panasonic MA3S132DG User manual

Panasonic

Panasonic MA3S132DG User manual

Panasonic MA3X789 (MA789) User manual

Panasonic

Panasonic MA3X789 (MA789) User manual

Panasonic Light Emitting Diodes LNJ0F1C5FRA1 User manual

Panasonic

Panasonic Light Emitting Diodes LNJ0F1C5FRA1 User manual

Panasonic HL-D3 Series User manual

Panasonic

Panasonic HL-D3 Series User manual

Panasonic HFQ EE26 User manual

Panasonic

Panasonic HFQ EE26 User manual

Panasonic KX-HNS104FX User manual

Panasonic

Panasonic KX-HNS104FX User manual

Panasonic HL-C203F-MK User manual

Panasonic

Panasonic HL-C203F-MK User manual

Panasonic SP Series Guide

Panasonic

Panasonic SP Series Guide

Panasonic WX-LA20 User manual

Panasonic

Panasonic WX-LA20 User manual

Panasonic KX-HNS103 User manual

Panasonic

Panasonic KX-HNS103 User manual

Panasonic MA24F70 User manual

Panasonic

Panasonic MA24F70 User manual

Panasonic PM-25 Series User manual

Panasonic

Panasonic PM-25 Series User manual

Panasonic HL-C21C Series User manual

Panasonic

Panasonic HL-C21C Series User manual

Panasonic EX-FC1 User manual

Panasonic

Panasonic EX-FC1 User manual

Panasonic LM10 User manual

Panasonic

Panasonic LM10 User manual

Panasonic MA4X726 (MA726) User manual

Panasonic

Panasonic MA4X726 (MA726) User manual

Panasonic MA3SE01 User manual

Panasonic

Panasonic MA3SE01 User manual

Panasonic SL-CH22 User manual

Panasonic

Panasonic SL-CH22 User manual

Popular Accessories manuals by other brands

Hudora 65138 INSTRUCTIONS ON ASSEMBLY AND USE

Hudora

Hudora 65138 INSTRUCTIONS ON ASSEMBLY AND USE

PCB Piezotronics 117B66 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 117B66 Installation and operating manual

Joolz Geo lower raincover instruction manual

Joolz

Joolz Geo lower raincover instruction manual

Leviton OSW12-M installation instructions

Leviton

Leviton OSW12-M installation instructions

BEMKO SES60WH instructions

BEMKO

BEMKO SES60WH instructions

Banner iVu Plus TG Series instruction manual

Banner

Banner iVu Plus TG Series instruction manual

IME ITalks MCS 1608 V2 installation manual

IME

IME ITalks MCS 1608 V2 installation manual

Vision ZD2106IN-7 Installation & operation manual

Vision

Vision ZD2106IN-7 Installation & operation manual

Antelope Orion owner's manual

Antelope

Antelope Orion owner's manual

Supmeter BST106-N59 Operation manual

Supmeter

Supmeter BST106-N59 Operation manual

Baumer URDK 09G8914 quick start guide

Baumer

Baumer URDK 09G8914 quick start guide

PCB Piezotronics 2508-02A Installation and operating manual

PCB Piezotronics

PCB Piezotronics 2508-02A Installation and operating manual

Homelite PS05189 instruction sheet

Homelite

Homelite PS05189 instruction sheet

ETC Echoflex Elaho installation guide

ETC

ETC Echoflex Elaho installation guide

LEGRAND 6 547 40 quick start guide

LEGRAND

LEGRAND 6 547 40 quick start guide

Elk ELK-319DR manual

Elk

Elk ELK-319DR manual

SSC-LUXon BAWI Assembly & operating instructions

SSC-LUXon

SSC-LUXon BAWI Assembly & operating instructions

Movisens EcgMove 4 Operating and safety instructions

Movisens

Movisens EcgMove 4 Operating and safety instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.