Table on Shifting Frequency Zone
Temperature, X (°C) Zone Frequency No. Shifting:
(Intake Air - Internal Setting) Cooling Mode / Soft Dry Mode Heating Mode
X-2.5 0Shift to Freq. MIN Shift to Freq. MAX
-2.5 X-1.5 1Shift to Freq. MIN Shift to Freq. MAX
-1.5 X-1.0 2-2 Freq. No. +2 Freq. No.
-1.0 X-0.5 3-1 Freq. No. +1 Freq. No.
-0.5 X+1.0 4Same Freq. No. Same Freq. No.
+0.5 X+1.0 5+1 Freq. No. -1 Freq. No.
+1.0 X+1.5 6+2 Freq. No. -2 Freq. No.
+1.5 X+2.5 7Shift to Freq. MAX Shift to Freq. MIN
X+2.5 8Shift to Freq. MAX Shift to Freq. MIN
Besides, the range of operation frequency will change according to the setting environment as listed below:
Condition: Freq. no. for E9CKP Freq. no. for E12CKP/E15CKP Remarks
MIN MAX MIN MAX
Cooling Mode 115 116 (a)
- if remote controller set 28°C & fan speed =
Hi
715 716 (a), (c)
- if remote controller set 28°C & fan speed =
Me-, Me, Me+, Auto
515 616 (a), (c)
- if remote controller set 28°C & fan speed =
Lo
415 516 (a), (c)
- if Powerful Mode ON 715 716 (a), (c)
Soft Dry Mode 4 7 4 8
Heating Mode 130 130 (b)
- if remote controller set 18°C & fan speed =
Hi
10 30 10 30 (b), (d)
- if remote control set 18°C & fan speed =
Me-, Me, Me+, Auto
930 930 (b), (d)
- if remote controller set 18°C & fan speed =
Lo
830 830 (b), (d)
- if Powerful Mode ON 10 30 10 30 (b), (d)
Remark:
(a) If frequency decreases from MAX, the following frequency performed will be depending to outdoor temperature, as given in below table
(for 30 seconds only) and then continues as normal rule.
Outdoor Temperature, X (°C) Frequency No.
X30 13
X30 7
(b) (If frequency increases from Freq. No. 17, the following frequency performed is as below (for 30 seconds only) and then continue as
normal rule.
Outdoor Temperature, X (°C) Frequency No.
X10 10
XX10 13
X 4 17
(c) When temperature different (intake - setting) < -1.0 °C or Thermo-Off activated and only valid for 120 seconds; not applicable during Soft
Dry Mode, and Anti-freezing control.
(d) When temperature different (intake - setting) > +1.5 °C or Thermo-Off activated and only valid for 130 seconds.
16
CS-E15CKP CU-E15CKP5