Panasonic ER-X Series User manual

INSTRUCTION MANUAL
Head part of ER-X series
ER-X□
CMJECK-ERXH No.0053-84V
Thank you very much for purchasing Panasonic products. Read this Instruction Man-
ual carefully and thoroughly for the correct and optimum use of this product. Kindly
keep this manual in a convenient place for quick reference.
WARNING
●This product produces high voltages.
●Do not use this product in places where there may be a danger of am-
mable or combustible items being present.
●To prevent electric shock and to conduct proper discharge, be sure to
ground a frame ground (F.G.) terminal of a controller.
●Do not place hands near the discharge needle. Doing so may cause elec-
tric shock.
● Since the tip of the discharge needle is sharp, take sufcient care in han-
dling the discharge needle, or injuries may result.
●The high-voltage cable between the head and the high-voltage unit must
be xed and the minimum bend radius is R30 mm or more.
In case of using at the bend radius R30 mm or less and using at moving
part may cause re and break down, etc. of the high-voltage cable.
●Clean the discharge needle regularly (about once a week). Otherwise, op-
timum charge removal performance may not be achieved, and accidents
or operating problems may occur.
● If this product is used in a conned space, ozone emitted from this prod-
uct may be detrimental. Be sure to provide ventilation.
●Do not direct ionized air toward the face. Ozone may cause irritation to
places such as the nose and throat.
1CAUTIONS
●This product has been developed / produced for industrial use only.
●Use this product with controller of ER-X series (optional) and head connec-
tion cable (optional).
●Do not use this product for purposes other than electric charge removal.
● Do not use this product in environments which are outside the specication
range, otherwise operating problems or damage may occur. In addition, the
operating life of the product may become signicantly reduced.
●This product is a precision device. Do not apply a shock to it by dropping,
for example. Accidents or operating problems may occur.
●Never disassemble, repair or modify this product. Accidents or operating
problems may occur.
● Do not throw this product in re. It may explode or toxic fumes may be gen-
erated.
●Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
●When connecting/removing the head or performing wiring or inspection
work, be sure to turn off the power rst. Not doing so may result in acci-
dents, electric shock or operating problems.
●When using as a CSA and UL compliant product, use a CLASS 2 CSA/
UL certified power supply, or a CSA/UL certified power supply that has
been evaluated as a Limited Power Source as specified in CAN/CSA-
C22.2NO.60950-1/UL60950-1.
● After connecting the cables, check that the connections are correct before
turning on the power. If the cables are connected incorrectly, operating
problems or accidents may occur.
●Do not use any cables which have any damage (such as splitting or crack-
ing), otherwise operating problems or accidents may occur.
●
Avoid using the product in places where there are high levels of steam or dust
in the air or where it might be directly exposed to water, oil or welding spatter.
●
Do not touch the discharge needle with hard objects such as tools. If the dis-
charge needle becomes broken, it will not provide sufcient charge removal
performance, and moreover operating problems or accidents may occur.
● Avoid use at an elevation higher than 2000m, and outdoor use.
●When cleaning or replacing the discharge needle, takecare not to damage
the tip of the discharge needle.
●During installation, fasten the product securely. If it is not securely fastened
or it is subjected to continuous vibration or shock, accidents or operating
problems may result.
●When disposing of this product, treat it appropriately as industrial waste.
●Use the correct combination of head, dischargeneedle unit and controller.
●ER-X001and ER-X008should be used with new types of controllers. If
connected to a previous type of contromtoller, after the power is on, the error
indicator lights up or blinks. New and old controllers can be distinguished
by their discharge frequency setting switches. New types show the numbers
20 and 50 in white-on-black.
Old type New type
2CE MARKED PRODUCT
●Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
3CSA/UL compliant product
● This product complies with CSA and UL standards, and has been certied
by TUV SUD.
4RoHS DIRECTIVE
●This equipment complies with RoHS (EU).
5DIMENSIONS (Unit: mm)
<ER-X001>
●Head part
28.5
20
12
16
6.2
4.2
18
14
24
44
70
6
8
ø13
ø12
M3 screw
Discharge
needle unit Ion air outlet
Bracket (removable)
●High-voltage unit
2-6.5 mounting holes
(48)
6
20
210
(20.5)
(ø35)
(17)
8.6
21010.5
35
(25)
(18)
38
222
165
25.4
21.5
6
ø17
High-voltage cable (Air tube is inside) ø10.5
12 core connector
ø6 air tube fitting (360°turn)
<Except ER-X001>
●Head part
40
C
D
(E)
40 A
28.5
9.4
22
18
30
28.5 B
9.4
Model No.
ER-X008 ER-X016 ER-X032 ER-X048 ER-X064
A40 120 280 440 600
B106 194 354 514 674
C138 226 386 546 706
D150 238 398 558 718
(E) 163 251 411 571 731
2-6.5
4.2
9.4
6.2
18
●High-voltage unit
9.5
31
180
160
6
28
18
5
38
(18)
35
(25)
17010.5
162
192
28.4
ø12
2-4.5 Mounting holes
2-6.5 Mounting holes High-voltage cable ø6.9
17
6
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Ofce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2016

INSTRUCTION MANUAL
Area ionizerER-X series
CME-ERX No.0046-89V
Thank you for purchasing Panasonic products.
Read this Instruction Manual carefully and thoroughly for the correct and optimum use of
this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
Never use this product as device for personnel protection.
In case of using devices for personnel protection, use products which meet laws or
standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in
each region or country.
1FOR SAFETY USE
WARNING
This product produces high voltages.
Do not use this product in places where there may be a danger of flammable or
combustible items being present.
To prevent electric shock and to conduct proper discharge, be sure to ground a frame
ground (F.G.) terminal of a controller.
Do not place hands near the discharge needle. Doing so may cause electric shock.
Since the tip of the discharge needle is sharp, take sufficient care in handling the
discharge needle, or injuries may result.
the minimum bend radius is R30 mm or more.
In case of using at the bend radius R30 mm or less and using at moving part may
Clean the discharge needle regularly (about once a week). Otherwise, optimum charge
removal performance may not be achieved, and accidents or operating problems may
occur.
detrimental. Be sure to provide ventilation.
the nose and throat.
CAUTION
This product has been developed / produced for industrial use only.
Do not use this product for purposes other than electric charge removal.
Do not use this product in environments which are outside the specification range,
otherwise operating problems or damage may occur. In addition, the operating life of the
Accidents or operating problems may occur.
Never disassemble, repair or modify this product. Accidents or operating problems may
occur.
Do not run the wires together with high-voltage lines or power lines or put them in the
same raceway.
This can cause malfunction due to induction.
When connecting/removing the head or performing wiring or inspection work, be
operating problems.
After connecting the cables, check that the connections are correct before turning on the
power. If the cables are connected incorrectly, operating problems or accidents may occur.
Verify that the supply voltage variation is within the rating.
In case using switching regulator, be sure to connect F.G. terminal.
Do not use any cables which have any damage (such as splitting or cracking), otherwise
operating problems or accidents may occur.
Avoid using the product in places where there are high levels of steam or dust in the air
Do not touch the discharge needle with hard objects such as tools. If the discharge
moreover operating problems or accidents may occur.
During installation, fasten the product securely. If it is not securely fastened or it is
subjected to continuous vibration or shock, accidents or operating problems may result.
Power cable that are 0.15mm2or more and 30m or less in total length for wiring.
Also, keep the wiring as short as possible in order to prevent noise.
When disposing of this product, treat it appropriately as industrial waste.
Use the correct combination of head, discharge needle unit and controller.
2PART DESCRIPTION
Bracket
Discharge needle unit
ER-XANT1
Head
ER-X001
Head
Discharge needle unit
ER-XANT or ER-XANS
Air inlet
Head
mounting
bracket
Discharge
needle
High-voltage cable (Note)
High-voltage unit
Head connection cable
ER-XCCJ2H, ER-XCCJ5H or ER-XCCJ10H
Controller
ER-XC02
Power cable (optional)
ER-XCC2 or ER-XCC5
High-voltage unit High-voltage cable (Note)
Air inlet
Note: The minimum bend radius of the high-voltage cable is R30 mm.
<Controller>
Discharge indicator (green) (Note)
Lights up during discharge , blink-
ing during discharge stopped.
CHECK indicator (orange)
Lights up when dirt, wear, etc. of
the discharge needle is detected.
Level meter indicator (green)
Indicates static buildup around the
head or the amount of ion generated
from the head.
Discharge control switch
ON: Discharge allowed
OFF: Discharge halt
SET UP button
Stores the settings for the
amount of ion and the check
threshold in memory.
Discharge frequency setting switch
Switches between discharge
frequency settings.
Ion balance setting switch
Sets ion balance.
Various setting switch
Refer to “ 6SETTING.”
ERROR indicator (red)
Lights up when abnormal
discharge is detected.
Note: An abbreviation of DISCHARGE.
3INSTALLATION
<Head installation>
Using 2 M4 screws or 1 M6 screw, mount the head
onto the equipment housing. In case using this prod-
uct in where there is vibration, use spring washers
etc. as a countermeasure.
Loosen the angle adjustment screw, adjust the head
angle, and then fasten the head with the tightening
The position of the head mounting bracket of the ER-X001
should be at least 20 mm from the end of the head. The
After mounting the head, set the controller according
to the procedures in “ 6SETTING” in order to
appropriately remove static electricity.
Angle adjustment
screw
M4 screw
M6 screw
Angle adjustment
screw
Screw for
M4 screw
Notes: 1) Be sure to ground the equipment housing onto which the head is mounted.
2) The distance between the head and the charge removing object should be 30 mm or more.If the static
buildup of the charge removing object is 30 kV or more, set the distance to 50 mm or more.
3) If there is metal near the head or between the head and the charge removing object, ion is absorbed,
hindering appropriate static removal. Install the head based on the above.
(surrounding metal.)
Surrounding
metal
Back-side mounting
(All frequencies)
50mm or more
Side mounting
50mm or more
Mouting ER-X001
Surrounding
metal
20mm
or more
20mm
or more
5) When installing two or more heads in face to face or parallel using different frequency, keep the distance be-
tween the heads 400mm or more.
When installing the heads face to face, install heads in distance that the heads can parform the charge
removal of a side of the object individualy.
Face-to-face installation Parallel installation
100mm
or more
100mm
or more
50mm or more 50mm
or more
<High-voltage unit installation>
Use 2 M4 screws or 2 M6 screws to fasten the
head.
The tightening torques for fastening, are as follows.
When using M4 screws: 1.2N·m
When using M6 screws: 2.5N·m
M4 screw
M6 screw
Notes: 1) Do not place any objects on top of the high-voltage unit.
2) When using multiple heads, keep the distance of at least 10 mm
between the high-voltage units.
3) When fastening the high-voltage unit using M6 screws, fasten
before connecting the head connection cable.
ER-X001 with M6 screw.
10mm or
more
<Controller installation>
Mount the controller on a 35 mm wide DIN rail or using M4 screws. For mounting
dimensions, refer to “ 15 DIMENSIONS”
When mounting on a DIN rail When mounting using M4 screws
1
2
35 mm wide DIN rail
Lock release
lever
M4 screw
Pull the lock release lever to remove this
product from the DIN rail.
The tightening torque should be 1.2 N·m or
less.

4WIRING
Power connector Pin arrangement
12345
678910
(Front view)
Housing: 5569-10A
Terminal
No. Terminal name Color code
1 0V Blue
2 COM(
-
)
㸫
3 Discharge control input Pink
4 COM(OUT) Violet
5 F.G. terminal Green/Yellow
6 24V Brown
7 COM(+)
㸫
8 COM(IN) White
9 Alarm output Orange
10 Error output Black
Note: Wire colors are colors of power supply cable of option.
When connecting the output to negative common
24V DC
s10%
1㸫
㸩
8
8
(Be sure to ground.)
(Brown)+V
COM(+)
(Violet) COM(OUT)
(Orange) Alarm output
(Black) Error output
(Pink) Discharge control input
(Blue)0V
COM(
-
)
(Green/Yellow)F.G.
Main circuit
Load
Load
(White) COM(IN)
When connecting the output to positive common
8
24V DC
s10%
2
㸫
㸩
Main circuit
Load
Load
(Brown)+V
COM(+)
(Violet) COM(OUT)
(Orange) Alarm output
(Black) Error output
(Pink) Discharge control input
(Blue)0V
COM(
-
)
(Green/Yellow)F.G. (Be sure to ground.)
(White) COM(IN)
*1 *2
Non-voltage contact or
PNP transistor/open collector
or
Contact “closed” or transistor ON: Discharge halt
Contact “open” or transistor OFF: Starting discharge
Non-voltage contact or
NPN transistor/open collector
or
Contact “closed” or transistor ON: Discharge halt
Contact “open” or transistor OFF: Starting discharge
Notes 1) In order to prevent electric shock and perform proper discharge , be sure to ground the F.G. terminal.
In addition, the head of ER-X001 and the F.G. terminal of a controller are common.
2) To stop discharge, turn ON the discharge control input for 20 ms or longer. To start discharge, turn OFF (open)
the discharge control input. Discharge will start in 20 ms.
5PIPING
Air supplied to this product will reduce contamination of the discharge needle and
improve the charge removal speed.
be ø6 mm.
Make sure that clean air (air containing no water, no oil and no dust) should be
supplied.
Since the pressure will drop when the air piping from the main pressure supply
it is not in short supply. For the pneumatic components, select those that can
㸺Except ER-X001㸼
Piping in the head
Air inlet
ø6 mm tube
Head section
(11.4mm)
㸺ER-X001㸼
Piping in the High-voltage unit
ȭ6mm air tube
High-voltage unit
Air inlet
(11.6mm)
Note: After inserting the tube into the joint of this product, always make sure that the tube is all the way in and securely
inserted.
6SETTING
The amount of ion generation is set to enable appropriate charge removal.
Start the setting after 30 minuets of the discharge starting.
How to set the amount of ion generation
1. Turn the discharge control switch ON and the discharge
control input “open” to start discharge.
Make sure that the discharge indicator (green) lights up.
Discharge control switch
2. Depending on the installation distance, set the frequency using the discharge
frequency setting switch.
Guideline when air is not supplied
For head 1 For head 2
Discharge frequency
setting switch
Discharge would be stopped at “Test A”
and “Test E” of Head 2.
Installation distance
Discharge
frequency setting
switch
Frequency
30Њ50mm 100
70
50Њ200mm 50
30
200Њ500mm 20
10
500Њ1,000mm 5
1
When air is supplied,
setting) first to see if it removes static electricity. Since using air, discharge
distance from the object can be longer.
If the amount of static build up on the charge removing object is large,
Set the frequency lower or make the installation distance shorter.
In case the voltage resistance of the object is low,
Set the frequency higher or make the installation distance longer.
Note: Depending on the head, different frequencies are accepted. If it is set to a wrong frequency, the discharge stops
and the discharge indicator blinks. For accepted frequencies, refer to "12 SPECIFICATIONS"
3. After mounting the head, adjust ion balance using the ion balance setting switch.
Turn to “
-
” to shift ion balance to the “
-
“ side.
Turn to “+” to shift ion balance to the “+” side.
Ion balance setting switch
For head 1 For head 2
Note:
Generally, ion reaching the charge removing object is affected by installation environment (nearby metals,
temperature, humidity, etc.). Although this product has been adjusted for ion balance at the factory, the preadjusted
ion balance may differ, depending on the customer’s installation environment. For more appropriate static removal,
please adjust ion balance according to your installation environment.
4. Press the SET UP button to lock in the setting. After the
setting is completed, level meter indicators change from
blinking to lighting up.
SET UP button
Notes: 1) Conduct the maintenance before setting.
2) Before the setting up, be sure that the check indicator is turned OFF. In case the check the indicator lights up
or blinks, the set up is not started. For detail , reffere to
9TROUBLE SHOOTING.”
control function works at OFF in despite of setting of ion balance control switch. After press down the set up
㸦
detecting function of ion generation depression
㸧
amount based on your enviroment.
4)
It takes 30 seconds to 1 minute to complete a setup procedure. Do not change the ambient environment at the
time. In case ambient environment is changed, the set up is not conducted and level meter indicator may blink.
5) In case the discharge frequency setting switch or the ion balance control switch is changed or installed envi-
ronment is changed, conduct the setup again.
6) The set up is conducted to two heads. Do not wire head that you do not use.
7) Setting the ion balance setting switch shown right, level meter indicators blink. And pushing down the SET
UP button for 3 seconds in this setting, the setting will be the factory setting.
Various setting switch
Various setting
switch Name Function
Check level
changeover switch
Switches between ion generation levels to output an alarm.
ON: Lights up the CHECK indicator and outputs an alarm, when ion
generation is reduced to a level that affects static removal.
OFF: Set this if you wish to be alerted soon after ion generation is reduced.
Ion balance
control switch
Switches between automatic ion balance control function settings.
ON: Enables automatic ion balance control function.
Senses the amount of ion generation and automatically controls it
to match the setting of the ion balance setting switch.
OFF: Disables automatic ion balance control function.
Ion continues to generate at the discharge ratio setting of the ion
balance setting switch.
Indicator change-
over switch
Switches between indications of the level meter indicator (green).
ON: Indicates the static buildup state of immediate
head. It shifts to the “+” or “-” side depending on the
amount of buildup.
positively charged.
OFF:
Indicates the amount of ion the head generates. Plus
ion generated is indicated on the “+” side and minus
ion on the “
-
” side.
minus ions are generated.
2 heads control
switch
Sets ion generation timing for two heads. If the two heads have different
discharge frequency, this setting will be invalid, and ion will be generated
at the frequency timing of each head.
ON:
When head 1 is generating plus ion, head 2 also generates plus ion.
(synchronous mode)
OFF: When head 1 is generating plus ion, head 2 generates minus ion.
(inversion mode)
Not used.
Notes: 1) All factory default settings are ON.
2) Checking function (detecting function of ion generation depression) is based on amount of ion generation
which was set in the set up.

7Charging function
By setting the discharge frequency setting switch for head 1 to
"+ Charge" or "- Charge", head 1 can beused as charger.
In the + charging mode, the upper 3 lamps of the level meter
indicator light, while in the - charging mode, the lower 3 lamps
light.
Notes: 1) Immediately after changing the discharging frequency setting switch, discharging stops and the level
meter indicator lamps go out. To enable the charging function, turn charging OFF and then ON again.
2) Head 2 performs normal removal of static electricity.
3) The charging function cannot be used in the ER-X001. (The discharging stops.)
8OUTPUT FUNCTIONS
<Alarm output>
Normally OFF
The alarm output switches from OFF to ON at the occurrence of a reduction in ion
setup data, etc.
During an alarm, discharge (charge removal) continues.
<Error output>
Normally ON (Turning ON after 3 seconds of power suppling)
The error output switches from ON to OFF at the occurrence of abnormal
discharge, output short circuit, etc.
During an error, discharge (charge removal) stops.
The error will not be cleared until its cause is eliminated and the power or
discharge control switch is turned on again.
Note: Refer to “ 9TROUBLE SHOOTING” for actions to be taken at the occurrence of an alarm and error.
<Forced output functions>
With this product, alarm output and error output can be forcedly-outputed by
setting the discharge frequency setting switch for head 2 to "Test A"or "Test E",
respectively.
Discharge frequency
setting switch
for head 2
Output Description
Alarm output
Set the discharge frequency setting switch for head 2 to "Test A".
CHECK indicator turns up, and alarm output will be forced to switch
from OFF to ON, generating an output.
Error output
Set the discharge frequency setting switch for head 2 to "Test E".
ERROR indicator turns up, and error output will be forced to switch
from ON to OFF, generating an output.
Note: During the enforced output, discharging of head 2 will be stopped.
9TROUBLE SHOOTING
Always be sure to turn off the power before checking the discharge part.
Output Indicator Cause Remedy
-
Discharge
indicator
(Green)
Discharge stopped.
Check whether the discharge control switch is ON, the
discharge control input is not shorted or discharge frequency
setting switch is not at "Test A" or "Test E".
Alarm ON
CHECK
indicator
(orange)
lights up
The discharge needle
unit is not in place.
to the main body.
Discharge needle is dirty Clean the discharge needle and its surroundings.
Refer to “ 11 MAINTENANCE” for details.
Discharge needle is
worn
If the CHECK indicator (orange) does not turn off even after
cleaning, replace the discharge needle unit, as it may be worn.
F.G. is not connected Check whether the F.G. terminal is connected.
CHECK
indicator
(orange)
nearby metals
Referring to “ 3INSTALLATION” place the head away from
nearby metals. Higher discharge frequency may help reduce
ERROR
indicator
Communication error
between head and
controller
Turn on the power again. If this error occurs as a result of
power shutoff during setup, press the SET UP button again to
complete setup.
Error OFF
ERROR
indicator
(red) lights
up
Abnormal discharge to
nearby metals.
Check whether the head is installed in appropriate
environment. Also, check whether any metal may come close
to the discharge needle.
Abnormal discharge
from the charge
removing object.
A large amount of static buildup on the charge removing object
may cause abnormal discharge. Increase the installation
distance and the speed of charge removal with air.
Foreign objects attached
to the discharge needle.
Foreign objects may cause abnormal discharge. Clean the
discharge needle and its surroundings before use.
Dew condensation
around the discharge
needle.
If the temperature environment changes rapidly, abnormal
discharge may result due to dew condensation. Clean the
discharge needle and its surroundings, and use it under a
stable environment.
Air is dirty.
Water or oil content in the air attached to the discharge needle
may cause abnormal discharge. When air is used, use clean
dry air only.
Incorrect head onnection Use the correct combination of head and controller.
Head not connected. Check whether the head is connected to the controller.
Damage If the error does not clear after turning on the power again and
taking the above actions, contact us.
-
Level meters
Setup is not completed. Press the SET UP button to lock in the setting.
-
Level meters
(green) light
up in order
Performing setup It takes 30 seconds to 1 minute to complete the setup.
-
Level meters
(green)
Check that the position of the ion balance setting switch is in
6SETTING” for details.
-
All indicator
momentarily
Output short circuit. Check whether the output is shorted or whether the output
load is too high.
is not connected properly. Be sure that the F.G. terminal is connected properly at
the end.
10
RoHS Directive
This product is in compliance with the RoHS Directive (EU).
11
MAINTENANCE
Be sure to turn off the power and air before performing maintenance work.
Take care not to damage the tip of the discharge needle.
Clean the discharge needle and its surroundings, where dirt or dust accumulates
after long use.
Clean it regularly, about once a week. Otherwise optimum charge removal
performance may not be achieved, and accidents or operating problems may occur.
The discharge needle is a consumable part. If charge removal performance does
not return to normal after the discharge needle has been cleaned, then the needle
unit should be replaced.
When replacing the discharge needle unit because of natural wear and use, replace
all units at the same time.
How to clean the discharge part
1. Always make sure that the discharge control switch or the power is OFF.
2. Remove any dirt from the discharge needle and its surroundings using a brush,
cotton swab, etc. moistened with alcohol.
㸺Except ER-X001㸼
Brush
Air outlet
Surrounding area
Discharge
needle
㸺ER-X001㸼
Air outlet
Surrounding area
Discharge
needle
Swab
In case of supplying air, there is possibility that around discharge needle or entire
discharge unit get dirty by oil or moisture included in the supplying air. Before
replacing the discharge unit, check the blot around discharge needle and clean the
entire unit and check the dischargebility is recovered. (the discharge needle unit
can be cleaned up easily with commercial super sonic washer.)
How to replace discharge needle unit
㸺Except ER-X001㸼
1. Slide the lock release lever of the discharge needle unit in the arrow 1 direction
shown in the illustration below.
2. Pull out the discharge needle unit toward the arrow 2 direction.
1
2
1
3
4
4
3. Insert the discharge needle unit (sold separately) in the arrow direction.
4. Slide the lock release lever of the discharge needle unit in the arrow 4 direction to
lock in the discharge needle unit.
Notes: 1) Do not touch the interior of the main body when the discharge needle unit is removed. Doing so will cause
accidents or operating problems.
2) An O-ring is used at the base of the discharge needle. When replacing the discharge needle unit, make sure
that the O-ring is in place.
O-ring
㸺ER-X001㸼
1. Turn the discharge needle unit counterclockwise (CCW) and pull out.
2. Insert the discharge needle unit (sold separately) vertically into the main body,
and turn clockwise (CW) all the way to the back.
1
2
Notes: 1) Do not use this product if the discharge needle unit is not inserted all the way to the back. It may cause an
accident or failure.
2) If the discharge needle unit is inserted at a slant and turned forcibly, the screw threads may strip and the unit
may not be inserted all the way to the back.
Good
Not Good

14
CE MARKED PRODUCT
This product is CE marked product.
Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
15
DIMENSIONS (Unit: mm)
<Head part> Please refer to the instruction manual of the head part for the form dimensions of ER-X001.
Head
40
C
D
E
40 A
28.5
9.4
22
18
30
28.5 B
9.4
ᆺᘧྡ ER-X008 ER-X016 ER-X032 ER-X048 ER-X064
A 40 120 280 440 600
B 106 194 354 514 674
C 138 226 386 546 706
D 150 238 398 558 718
E163 251 411 571 731
4.2
9.4
6.2
18
2-6.5
High-voltage unit
9.5
31
180
160
6
17
28
18
5
38
18
35
25
17010.5
162
192
28.4
ø12
2-4.5 Mounting holes
2-6.5 Mounting holes
High-voltage cable ø6.9
<Controller>
(23.2)
9.2
Head connection
connector
S12B-PUDSS-1
[Manufactured by
For head 1
For head 2
2-5.0
Mounting
holes
(16) (16)
18
9.3
44
5.2
76 7
39
7
97 6.5
53
10
60 4
16.5
35 mm wide DIN rail
140
0
103.5
35.4 27.3
9.1
14
14
9.1
8.8
8.8
ø6
<Head connection cable> <Power cable>
14.4
22.2
19.6
ø5.3
12
SPECIFICATIONS
Type Head
Model No. ER-X001 ER-X008 ER-X016 ER-X032 ER-X048 ER-X064
Effective charge removal
width 50mm 80mm 160mm 320mm 480mm 640mm
Charge removal time
0.3 second or
less (Note 1)
0.5 second or
less (Note 2)
1 second or less (Note 3)
Ion balance ±30V or less (Note 2) (Note 3) (Note 4)
Discharge method Pulse AC method (Note 5)
Discharge output voltage
0.01ppm or less (Note 2) (Note 3)
0.5MPa
Air (dried clean air) (Note 6)
Ambient temperature
0
to +
50°C (ER-X0010
to +
40°C) (with no dew condensation), For storage: -10 to +65°C
Ambient humidity 35 to 65%RH. For storage: 35 to 85%RH
Vibration resistance
(ER-X001
)
, 0.75mm amplitude for 2
hours in each of XYZ directions (when the power is off)
Shock resistance
Resistance 100 m/s2
Enclosure grounding method Floating
Material
Main unit enclosure: PPS, Stainless steal (SUS).
Head mounting bracket: Stainless steal (SUS).
Discharge needle: PFA, PC, PPS, Tungsten (Note 7).
High-voltage cable length 1.2m 0.5m Note 8㸧
Weight .
370g
330g
410g
530g
650g
780g
Notes: 1)
In condition of discharge distance
50mm
3)
In condition of discharge distance
100mm
than ±10°C ambient temperature change, set the ion balance after 30 minutes of the discharge starting,
switching on the ion balance control function.
5) For ER-X001 are accepted. For ER-X008 and high-voltage cables
7) Silicon needles are also available. Please contact us for details.
8) High-voltage cables are also available in 1m and 2m lengths. Please contact us for details.
Type Controller
Model No. ER-XC02
Number of charge removal
heads connected
Supply voltage 24V DC±10%
Current consumption 450mA or less when connecting 1 heads.
800mA or less when connecting 2 heads.
Indictor Displays status of Head 1 and 2
DSC (Discharge)
CHECK
ERROR
Level meter
Output
ALARM, ERROR
COM (COM OUT)
PhotoMOS relay output
Applied voltage: 30VDC or less (between output-output common)
Residual voltage: 1.5V or less (at load current of 100mA)
Output operation
ALARM: ON when dirt or wear of the discharge needle is detected;
OFF when operation is normal.
ERROR: OFF when abnormal discharge is detected;
ON when operation is normal.
Short-circuit operation Equipped (automatic reset type)
Intput
Discharge control input (DSC OFF)
COM㸦COM IN
Photo coupler input
࣭Input current: 4.5mA or less
࣭Input voltage: 30VDC or less (between input-input common)
࣭
Input operation Discharge allowed: Open. Discharge halt: 24V or 0V shorted.
Ambient temperature 0 to +50°C (with no dew condensation). For storage: -10 to +65°C
Ambient humidity 35 to 65%RH. For storage: 35 to 85%RH
Voltage resistance AC 1000V, 1 minute, completely charged part/between enclosures
AC 500V, 1 minute, charged part/between F.G.
Insulation resistance
Vibration resistance
(when power is off)
Shock resistance Resistance 100 m/s2
(when the power is off)
Enclosure grounding method Floating
Material Enclosure: ABS
Weight
Accessories
Power supply / I/O connector: 1 set
Type Head connection cable
Model No. ER-XCCJ2H ER-XCCJ5H ER-XCCJ10H
Length 2m 5m 10m
Cable Cabtyre cable with connectors at both ends
Weight
13
OPTIONS (sold separately)
Spare discharge needle unit
For ER-X016 to䢢X064
ER-XANT, ER-XANSNote
For ER-X008
ER-XANT2
For ER-X001
ER-XANT1
AC adapter ER-XAPS-EX For ER-X016 to X064
Discharge part protective cover
ER-XACVR
Power cables ER-XCC22m
ER-XCC55m
Note: ER-XANT of the spare discharge needle unit is a tungsten needle, and ER-XANS is a silicon needle. Use it com-
bined correctly with the head.
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2014
Other manuals for ER-X Series
2
This manual suits for next models
6
Table of contents
Other Panasonic Air Ionizer manuals

Panasonic
Panasonic ER-X Series User manual

Panasonic
Panasonic ER-VW User manual

Panasonic
Panasonic ER-VW User manual

Panasonic
Panasonic ER-Q User manual

Panasonic
Panasonic TK-AS700 User manual

Panasonic
Panasonic F-GPT01R User manual

Panasonic
Panasonic TK-AS700-EX User manual

Panasonic
Panasonic nanoe F-GMG01A User manual

Panasonic
Panasonic TK-AS66-ZEX User manual

Panasonic
Panasonic Nanoe EH-SA43 User manual