7SHORT-CIRCUIT PROTECTION
●The power supply unit of this equipment adopts the electronic fuse
which do not require any replacement.
●When the electronic fuse is operated, turn OFF the power supply, and remove
the cause of overcurrent before restarting the power supply for resetting.
●The electronic fuse is not suitable to use in which the equipment is op-
erated continuously or daily. Note that operating the equipment continu-
ously may be unable to satisfy the specications.
8FUNCTIONS
●Trailing edge switching function
• This function is to accept the input when the reset switch is pressed (con-
tact “close”) and then released (contact “open”) at the manual start setting.
An unexpected start-up due to the welded reset switch can be avoided.
●Test input polarity selection function
• The function is used to change the polarity of the test input to PNP or
NPN with an internal switch.
9MAINTENANCE
●Be sure to do maintenance before use and 6 month periodic maintenance.
Refer included instruction manual of light curtain for the inspection items.
●In case replacing this device to new this device, be sure special techni-
cian to exchange it. And do daily maintenance and periodic maintenance.
10
SPECIFICATIONS
Model No.
Item SF-AC
Connectable input device
Light curtains manufactured by Panasonic Industrial Devices SUNX (PNP output type)
Applicable standard
EN 60947-5-1, EN ISO 13849-1 (Category 4,PLe)
EN ISO 13849-2, IEC 60947-5-1, ISO 13849-1 (Category 4, PLe)
ISO 13849-2, JIS B 9705-1 (Category 4)
Control category ISO 13849-1 compliance up to Category 4
Supply voltage 24V DC±10% Ripple P-P 10% or less
Fuse rating Built-in electronic fuse, Breaking current: 1.1A or more
reset by power supply stop
Power consumption Approx. 1.7W (without light curtain)
Safety output (Note 1)
NO contact × 3
Switching capacity
(13-14, 23-24, 33-34)
Max. 6A 30V DC / 6A 230V AC, resistive load
Fuse 6A (slow-blow)
Auxiliary output NC contact × 1
Switching capacity
(41-42) Max. 1A 24V DC
Fuse 1A (slow-blow)
Alarm output
NC contact × 1 (Non-safety contact, related to input “Alarm in”)
Switching capacity
(51-52) Max. 1A 24V DC, Min. 5mA 24V DC
Fuse 1A (slow-blow)
Application category AC-15, DC-13(IEC 60947-5-1)
Pick-up delay 40ms or less / 50ms or less (Auto reset / Manual reset)
Drop-out delay 10ms or less
Contact material / contacts
AgSnO, Self cleaning, positively driven
Contact resistance (Initial value)
100mΩ or less
Mechanical lifetime
10,000,000 times or more (switching frequency 180 times/min.) (Note 2)
Electrical lifetime
100,000 times or more (switching frequency 20 times/min. at
230V AC / 3A, resistive load) (Note 2)
Trailing edge function
Incorporated
Test input polarity
selection function
Incorporated (Selectable PNP or NPN test input polarity by
internal switch)
Overvoltage category
III
B10d (Note 3) 20,000,000 (load: 20%)
Environmental resistance
Protection Enclosure: IP40, Terminal: IP20
(This product must be installed into a control box having IP54 construction.)
Ambient temperature
-10 to +55°C (No dew condensation or icing allowed)
Storage: -10 to +55°C
Ambient humidity
35 to 85% RH, Storage: 35 to 95% RH
Vibration resistance
No malfunction when tested with 10 to 55Hz frequency, 0.35mm
amplitude in X, Y and Z directions for twenty times each
Pollution degree 2
Connection terminal Removable European terminal
Material Enclosure: Polycarbonate
Weight Approx. 400g
Notes: 1) Timing chart of the safety output is diagram below.
2) The lifetime of the switch of relay depends on type of the load, frequency of
switching or environment etc.
3) Mean cycle time that 10% of parts reach dangerous failure.
Light
received
Light
blocked
Light received status
Response time of Light curtain
ON
OFF
ON
OFF
Control output 1 / 2 (OSSD
1 / 2) of light curtain
Safety input of this device
10ms or less
6EXAMPLE OF CONNECTION CIRCUIT WITH
LIGHT CURTAIN
Please wire between X1-X2 when using it by the manual reset as shown in the
gure below or please wire between X1-X3 when using it by the auto reset.
●SF4B<V2> series
• Please set the test input polarity selection switch to the “PNP” side.
●SF4-AH series
• Please set the test input polarity selection switch to the “PNP” side.
●SF2-EH series
• Please set the test input polarity selection switch to the “NPN” side.
E_+V
E_0V
PE
E_F.G.
E_SY+
E_SY
-
T_IN
R_+V
R_0V
R_F.G.
R_SY+
R_SY
-
S1
S2
Emitter
Receiver
Interlock setting input (Pale purple)
+V (Brown)
Emission halt input / Reset input (Pink)
0V (Blue)
Auxiliary output (Yellow-green / Black)
Output polarity setting wire (Shield)
Synchronization + (Orange)
Synchronization
-
(Orange / Black)
External device monitor input (Yellow-green)
+V (Brown)
Control output 1 (OSSD 1) (Black)
0V (Blue)
Control output 2 (OSSD 2) (White)
Output polarity setting wire (Shield)
Synchronization + (Orange)
Synchronization
-
(Orange / Black)
SF-AC
E_+V
A_IN
E_0V
E_F.G.
E_SY+
E_SY
-
T_IN
R_+V
R_0V
R_F.G.
R_SY+
R_SY
-
S1
S2
PE
SF-AC
Emitter
Receiver
+V (Brown)
0V (Blue)
Emission halt input (Pink)
Auxiliary output (Gray)
Shield
Synchronization + (Orange)
Synchronization
-
(Orange / Black)
+V (Brown)
Control output 1 (OSSD 1) (Black)
0V (Blue)
Control output 2 (OSSD 2) (White)
Shield
Synchronization + (Orange)
Synchronization
-
(Orange / Black)
E_F.G.
E_SY+
E_SY
-
R_+V
T_IN
R_0V
R_F.G.
R_SY+
R_SY
-
S1
S2
E_+V
E_0V
PE
SF-AC
Emitter
Receiver
Interference prevention + (Gray)
Interference prevention
-
(Gray / Black)
+V (Brown)
0V (Blue)
Master / slave switching input (Purple)
Shield
Synchronization + (Orange)
Synchronization
-
(Orange / Black)
Emission halt input (Pink)
+V (Brown)
Control output 1 (OSSD 1) (Black)
0V (Blue)
Control output 2 (OSSD 2) (White)
Shield
Synchronization + (Orange)
Synchronization
-
(Orange / Black)
Interference prevention + (Gray)
Interference prevention
-
(Gray / Black)