manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Panasonic
  6. •
  7. Measuring Instrument
  8. •
  9. Panasonic LH2H preset User manual

Panasonic LH2H preset User manual

Other manuals for LH2H preset

2

Other Panasonic Measuring Instrument manuals

Panasonic BL-WV10A User manual

Panasonic

Panasonic BL-WV10A User manual

Panasonic WJHD500 - DIGITAL DISC RECORDE User manual

Panasonic

Panasonic WJHD500 - DIGITAL DISC RECORDE User manual

Panasonic TH13 Series User manual

Panasonic

Panasonic TH13 Series User manual

Panasonic LH2H preset User manual

Panasonic

Panasonic LH2H preset User manual

Panasonic ShowStopper PV-SS2710 User manual

Panasonic

Panasonic ShowStopper PV-SS2710 User manual

Panasonic KW2M-A User manual

Panasonic

Panasonic KW2M-A User manual

Panasonic AG-RT850P User manual

Panasonic

Panasonic AG-RT850P User manual

Panasonic EYFR02 User manual

Panasonic

Panasonic EYFR02 User manual

Panasonic Omnivision PV-V4600 User manual

Panasonic

Panasonic Omnivision PV-V4600 User manual

Panasonic AG-HPG20P Technical manual

Panasonic

Panasonic AG-HPG20P Technical manual

Panasonic Omnivision VHS PV-7453 User manual

Panasonic

Panasonic Omnivision VHS PV-7453 User manual

Panasonic DMR-HW220 User manual

Panasonic

Panasonic DMR-HW220 User manual

Panasonic SV-3800 User manual

Panasonic

Panasonic SV-3800 User manual

Panasonic PV-V4524S User manual

Panasonic

Panasonic PV-V4524S User manual

Panasonic FZ-VNP001U User manual

Panasonic

Panasonic FZ-VNP001U User manual

Panasonic KW2M User manual

Panasonic

Panasonic KW2M User manual

Panasonic KW9M Eco-Power Meter User manual

Panasonic

Panasonic KW9M Eco-Power Meter User manual

Panasonic KW2M-A User manual

Panasonic

Panasonic KW2M-A User manual

Panasonic KW9M Eco-Power Meter User manual

Panasonic

Panasonic KW9M Eco-Power Meter User manual

Panasonic KW9M Eco-Power Meter User manual

Panasonic

Panasonic KW9M Eco-Power Meter User manual

Panasonic RR-QR230E User manual

Panasonic

Panasonic RR-QR230E User manual

Panasonic NV-8950 User manual

Panasonic

Panasonic NV-8950 User manual

Panasonic LC2H preset User manual

Panasonic

Panasonic LC2H preset User manual

Panasonic AG6124 User manual

Panasonic

Panasonic AG6124 User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

2022.6
Hour Meter
LH2H
* The contents of this catalog are as of October 2017.
For the latest information, please visit our company website.
Panel mounting type
PC board mounting type
One-touch installation type Installation frame type
2
Hour Meter
LH2H Hour Meter
RoHS compliance
PRODUCT TYPES
PC board mounting type
Input method Measurement time range Backlight Front reset Model No.
Non-voltage input type
0 to 999999.9 h No No No LH2H-C-H-N
No 0 to 9999 h 59.9 m No No LH2H-C-HM-N
Note: There is no front panel reset button on the PC board mounting type.
Panel mounting type
Installation
type
Input method
Measurement time range (switchable)
Backlight Front reset Model No.0 to 999999.9 h
0 to 999 h 59 m 59 s
0 to 3999 d 23.9 h
0 to 9999 h 59.9 m
One-touch installation type
Non-voltage input type
Yes No No Yes LH2H-FE-DHK
No Yes No Yes LH2H-FE-HMK
Voltage input type
(4.5 to 30 V DC)
Yes No No Yes LH2H-FE-DHK-DL
No Yes No Yes LH2H-FE-HMK-DL
Yes No Yes Yes LH2H-FE-DHK-DL-B
No Yes Yes Yes LH2H-FE-HMK-DL-B
Free voltage input type
(24 to 240 V AC/DC)
Yes No No Yes LH2H-FE-DHK-FV
No Yes No Yes LH2H-FE-HMK-FV
Installation frame type
Non-voltage input type
Yes No No Yes LH2H-F-DHK
No Yes No Yes LH2H-F-HMK
Voltage input type
(4.5 to 30 V DC)
Yes No No Yes LH2H-F-DHK-DL
No Yes No Yes LH2H-F-HMK-DL
Yes No Yes Yes LH2H-F-DHK-DL-B
No Yes Yes Yes LH2H-F-HMK-DL-B
Free voltage input type
(24 to 240 V AC/DC)
Yes No No Yes LH2H-F-DHK-FV
No Yes No Yes LH2H-F-HMK-FV
Note: Please ask us about products without front reset button.
* Refer to our website for details of product.
Panel mounting type
PC board mounting type
One-touch installation type Installation frame type
Features
•7-segment LCD with 8.7 mm 0.343 in letter
height (total digits: 7)
• Select by switch between two time ranges
in a single meter.
• Battery replacement easy on environment
• Screw terminals are constructed to
protect ngers to ensure safety.
• Backlight can be switched between green
and red (for backlight type)
•IP66 compliant for resistance against
negative environmental inuences
(only when panel surface uses rubber
packing) (for installation frame type)
•Replaceable panel cover
Panel design can be changed from standard (ash gray) to
black (sold separately).
IP66
Time selectable
Large display in a small body,
achieving high viewability and
user-friendliness
LH2H Hour Meter
3
Non-voltage input type
• Never apply voltage to the non-voltage input type. This
will damage the internal elements.
•Since the current ow is very small from the start input
and reset input terminals ( and on panel mounting
type and to and to on PC board mounting
type) please use relays and switches with high contact
reliability. When inputting with an open collector of a
transistor, use a transistor for small signals in which ICBO
is 1 μA or less and always input with no voltage.
• When wiring, try to keep all the input lines to the start and
reset inputs as short as possible and avoid running them
together with high voltage and power transmission lines
or in a power conduit. Also, malfunctions might occur if
the oating capacitance of these wires exceeds 500 pF
(10 m 32.808 ft. for parallel wires of 2 mm2). In particular,
when using shielded wiring, be careful of the capacitance
between wires.
Voltage input type
• Be aware that applying more than 30 V DC to start input
terminals and , and reset input terminals and
will cause damage to the internal elements.
•For external resetting use H level (application of 4.5 to
30 V DC) between reset terminals and of the rear
terminals. In this case, connect + to terminal and – to
terminal . This is the valid polarity; therefore, the hour
meter will not work if reversed.
• When wiring, try to keep all the input lines to the start and
reset inputs as short as possible and avoid running them
together with high voltage and power transmission lines
or in a power conduit. Also, malfunctions might occur if
the oating capacitance of these wires exceeds 500 pF
(10 m 32.808 ft. for parallel wires of 2 mm2).
Backlight luminance
To prevent varying luminance among backlights when using
multiple backlight types, please use the same backlight
power supply.
Terminal connection
Tighten the terminal screws with a torque of 0.8 N·m or
less.
Free voltage input type
How to reset multiple panel mounting type counters all
at once (input is the same for count)
• Use start input terminals and for free voltage input
and reset input terminals and for non-voltage input.
•Be aware that the application of voltage that exceeds the
voltage range of the H level to the start input terminal,
and the application of voltage to the reset input terminal,
can cause damage to the internal elements.
•Since the current ow is very small from reset input
terminal , please use relays and switches with high
contact reliability.
• When inputting a reset with an open collector of a
transistor, use a transistor for small signals in which ICBO
is 1 μA or less and always input with no voltage.
•To reset externally, short reset input terminals and
on the rear.
• Input uses a high impedance circuit; therefore, erroneous
operation may occur if the inuence of induction voltage
is present. If you plan to use wiring for the input signal
that is 10 m 32.808 ft. or longer (wire capacitance 120
pF/m at normal temperature), we recommend the use of
a CR lter or the connection of a bleeder resistor.
PC board mounting type
For both panel mounting and PC board mounting types
Non-voltage input type
Voltage input type
•For external power supply use manganese dioxide or
lithium batteries (CR type: 3 V).
•Always reset after external power is applied and conrm
that the display reads “0”.
• Make the wiring from the battery to the hour meter unit as
short as absolutely possible. Also, be careful of polarity.
• Calculate battery life with the following formula.
t = A/I
t: battery life [h]
I: LH2H current consumption [mA]
A: battery capacity until minimum
operation voltage is reached [mAh]
• Hand solder to the lead terminal. Do not dip solder. With
the tip of the soldering iron at 300
°C
572 °F perform
soldering within 3 seconds (for 30 to 60 W soldering iron).
Notes: 1) Use the following as a guide for choosing transistors used for
input (Tr).
Leakage current < 1 μA
2) Use as small a diode (D) as possible in the forward voltage so
that the voltage between terminals 3 and 4 during reset input
meets the standard value (0.5 V). (At IF = 20 μA, forward
voltage: Max. 0.1 V)
Note: Make sure that H (reset ON) level is at least 4.5 V.
3or
DTr
4 3 4 3 4
D D
3or
+V +V
R
Tr
4 3 4 3 4 3 4
22
52
RedGreen
5
626
24 V DC 24 V DC
CAUTIONS FOR USE
Disclaimer
Theapplicationsdescribedinthecatalogareallintendedforexamplesonly.Thepurchaseofourproductsdescribedinthecatalogshallnotbe
regardedasgrantingofalicensetouseourproductsinthedescribedapplications.WedoNOTwarrantthatwehaveobtainedsome
intellectualproperties,suchaspatentrights,withrespecttosuchapplications,orthatthedescribedapplicationsmaynotinfringeany
intellectualpropertyrights,suchaspatentrights,ofathirdparty.
PrintedinJapan
IndustrialDeviceBusinessDivision
7-1-1,Morofuku,Daito-shi,Osaka574-0044,Japan
industrial.panasonic.com/ac/e/
ⓒ PanasonicIndustryCo.,Ltd. Specificationsaresubjecttochangewithoutnotice. 2022.6