2022.6
Hour Meter
LH2H
* The contents of this catalog are as of October 2017.
For the latest information, please visit our company website.
Panel mounting type
PC board mounting type
One-touch installation type Installation frame type
2
Hour Meter
LH2H Hour Meter
RoHS compliance
PRODUCT TYPES
PC board mounting type
Input method Measurement time range Backlight Front reset Model No.
Non-voltage input type
0 to 999999.9 h No No No LH2H-C-H-N
No 0 to 9999 h 59.9 m No No LH2H-C-HM-N
Note: There is no front panel reset button on the PC board mounting type.
Panel mounting type
Installation
type
Input method
Measurement time range (switchable)
Backlight Front reset Model No.0 to 999999.9 h
0 to 999 h 59 m 59 s
0 to 3999 d 23.9 h
0 to 9999 h 59.9 m
One-touch installation type
Non-voltage input type
Yes No No Yes LH2H-FE-DHK
No Yes No Yes LH2H-FE-HMK
Voltage input type
(4.5 to 30 V DC)
Yes No No Yes LH2H-FE-DHK-DL
No Yes No Yes LH2H-FE-HMK-DL
Yes No Yes Yes LH2H-FE-DHK-DL-B
No Yes Yes Yes LH2H-FE-HMK-DL-B
Free voltage input type
(24 to 240 V AC/DC)
Yes No No Yes LH2H-FE-DHK-FV
No Yes No Yes LH2H-FE-HMK-FV
Installation frame type
Non-voltage input type
Yes No No Yes LH2H-F-DHK
No Yes No Yes LH2H-F-HMK
Voltage input type
(4.5 to 30 V DC)
Yes No No Yes LH2H-F-DHK-DL
No Yes No Yes LH2H-F-HMK-DL
Yes No Yes Yes LH2H-F-DHK-DL-B
No Yes Yes Yes LH2H-F-HMK-DL-B
Free voltage input type
(24 to 240 V AC/DC)
Yes No No Yes LH2H-F-DHK-FV
No Yes No Yes LH2H-F-HMK-FV
Note: Please ask us about products without front reset button.
* Refer to our website for details of product.
Panel mounting type
PC board mounting type
One-touch installation type Installation frame type
Features
•7-segment LCD with 8.7 mm 0.343 in letter
height (total digits: 7)
• Select by switch between two time ranges
in a single meter.
• Battery replacement easy on environment
• Screw terminals are constructed to
protect ngers to ensure safety.
• Backlight can be switched between green
and red (for backlight type)
•IP66 compliant for resistance against
negative environmental inuences
(only when panel surface uses rubber
packing) (for installation frame type)
•Replaceable panel cover
Panel design can be changed from standard (ash gray) to
black (sold separately).
IP66
Time selectable
Large display in a small body,
achieving high viewability and
user-friendliness
LH2H Hour Meter
3
Non-voltage input type
• Never apply voltage to the non-voltage input type. This
will damage the internal elements.
•Since the current ow is very small from the start input
and reset input terminals ( and on panel mounting
type and to and to on PC board mounting
type) please use relays and switches with high contact
reliability. When inputting with an open collector of a
transistor, use a transistor for small signals in which ICBO
is 1 μA or less and always input with no voltage.
• When wiring, try to keep all the input lines to the start and
reset inputs as short as possible and avoid running them
together with high voltage and power transmission lines
or in a power conduit. Also, malfunctions might occur if
the oating capacitance of these wires exceeds 500 pF
(10 m 32.808 ft. for parallel wires of 2 mm2). In particular,
when using shielded wiring, be careful of the capacitance
between wires.
Voltage input type
• Be aware that applying more than 30 V DC to start input
terminals and , and reset input terminals and
will cause damage to the internal elements.
•For external resetting use H level (application of 4.5 to
30 V DC) between reset terminals and of the rear
terminals. In this case, connect + to terminal and – to
terminal . This is the valid polarity; therefore, the hour
meter will not work if reversed.
• When wiring, try to keep all the input lines to the start and
reset inputs as short as possible and avoid running them
together with high voltage and power transmission lines
or in a power conduit. Also, malfunctions might occur if
the oating capacitance of these wires exceeds 500 pF
(10 m 32.808 ft. for parallel wires of 2 mm2).
Backlight luminance
To prevent varying luminance among backlights when using
multiple backlight types, please use the same backlight
power supply.
Terminal connection
Tighten the terminal screws with a torque of 0.8 N·m or
less.
Free voltage input type
How to reset multiple panel mounting type counters all
at once (input is the same for count)
• Use start input terminals and for free voltage input
and reset input terminals and for non-voltage input.
•Be aware that the application of voltage that exceeds the
voltage range of the H level to the start input terminal,
and the application of voltage to the reset input terminal,
can cause damage to the internal elements.
•Since the current ow is very small from reset input
terminal , please use relays and switches with high
contact reliability.
• When inputting a reset with an open collector of a
transistor, use a transistor for small signals in which ICBO
is 1 μA or less and always input with no voltage.
•To reset externally, short reset input terminals and
on the rear.
• Input uses a high impedance circuit; therefore, erroneous
operation may occur if the inuence of induction voltage
is present. If you plan to use wiring for the input signal
that is 10 m 32.808 ft. or longer (wire capacitance 120
pF/m at normal temperature), we recommend the use of
a CR lter or the connection of a bleeder resistor.
PC board mounting type
For both panel mounting and PC board mounting types
Non-voltage input type
Voltage input type
•For external power supply use manganese dioxide or
lithium batteries (CR type: 3 V).
•Always reset after external power is applied and conrm
that the display reads “0”.
• Make the wiring from the battery to the hour meter unit as
short as absolutely possible. Also, be careful of polarity.
• Calculate battery life with the following formula.
t = A/I
t: battery life [h]
I: LH2H current consumption [mA]
A: battery capacity until minimum
operation voltage is reached [mAh]
• Hand solder to the lead terminal. Do not dip solder. With
the tip of the soldering iron at 300
°C
572 °F perform
soldering within 3 seconds (for 30 to 60 W soldering iron).
Notes: 1) Use the following as a guide for choosing transistors used for
input (Tr).
Leakage current < 1 μA
2) Use as small a diode (D) as possible in the forward voltage so
that the voltage between terminals 3 and 4 during reset input
meets the standard value (0.5 V). (At IF = 20 μA, forward
voltage: Max. 0.1 V)
Note: Make sure that H (reset ON) level is at least 4.5 V.
3or
DTr
4 3 4 3 4
D D
3or
+V +V
R
Tr
4 3 4 3 4 3 4
22
52
RedGreen
5
626
24 V DC 24 V DC
CAUTIONS FOR USE
Disclaimer
Theapplicationsdescribedinthecatalogareallintendedforexamplesonly.Thepurchaseofourproductsdescribedinthecatalogshallnotbe
regardedasgrantingofalicensetouseourproductsinthedescribedapplications.WedoNOTwarrantthatwehaveobtainedsome
intellectualproperties,suchaspatentrights,withrespecttosuchapplications,orthatthedescribedapplicationsmaynotinfringeany
intellectualpropertyrights,suchaspatentrights,ofathirdparty.
PrintedinJapan
IndustrialDeviceBusinessDivision
7-1-1,Morofuku,Daito-shi,Osaka574-0044,Japan
industrial.panasonic.com/ac/e/
ⓒ PanasonicIndustryCo.,Ltd. Specificationsaresubjecttochangewithoutnotice. 2022.6
PanasonicIndustryCo.,Ltd.

Other manuals for LH2H preset

2

Other Panasonic Measuring Instrument manuals

Panasonic LP-400 Series Use and maintenance manual

Panasonic

Panasonic LP-400 Series Use and maintenance manual

Panasonic KW8M User manual

Panasonic

Panasonic KW8M User manual

Panasonic K-NL316G User manual

Panasonic

Panasonic K-NL316G User manual

Panasonic DMR-UBT1GL-K User manual

Panasonic

Panasonic DMR-UBT1GL-K User manual

Panasonic KW2M-A User manual

Panasonic

Panasonic KW2M-A User manual

Panasonic WJHD500 - DIGITAL DISC RECORDE User manual

Panasonic

Panasonic WJHD500 - DIGITAL DISC RECORDE User manual

Panasonic KW2M User manual

Panasonic

Panasonic KW2M User manual

Panasonic WJ-NX100/2E User manual

Panasonic

Panasonic WJ-NX100/2E User manual

Panasonic NA1-11 User manual

Panasonic

Panasonic NA1-11 User manual

Panasonic LC2H preset User manual

Panasonic

Panasonic LC2H preset User manual

Panasonic KW9M Eco-Power Meter User manual

Panasonic

Panasonic KW9M Eco-Power Meter User manual

Panasonic AJ-PG50EJ User manual

Panasonic

Panasonic AJ-PG50EJ User manual

Panasonic NV-8950 User manual

Panasonic

Panasonic NV-8950 User manual

Panasonic FM-252-4(-P) User manual

Panasonic

Panasonic FM-252-4(-P) User manual

Panasonic LH2H-FE-DHK User manual

Panasonic

Panasonic LH2H-FE-DHK User manual

Panasonic AG-HPG20P Technical manual

Panasonic

Panasonic AG-HPG20P Technical manual

Panasonic KW1M-H User manual

Panasonic

Panasonic KW1M-H User manual

Panasonic LP-V10U-C User manual

Panasonic

Panasonic LP-V10U-C User manual

Panasonic LH2H preset User manual

Panasonic

Panasonic LH2H preset User manual

Panasonic FZ-VNP001U User manual

Panasonic

Panasonic FZ-VNP001U User manual

Panasonic LH2H preset User manual

Panasonic

Panasonic LH2H preset User manual

Panasonic PV-V4524S User manual

Panasonic

Panasonic PV-V4524S User manual

Panasonic WJ-NV300K/GJ User manual

Panasonic

Panasonic WJ-NV300K/GJ User manual

Panasonic KW2M-A User manual

Panasonic

Panasonic KW2M-A User manual

Popular Measuring Instrument manuals by other brands

GANN HYDROMETTE BL H 41 Operation instructions

GANN

GANN HYDROMETTE BL H 41 Operation instructions

Wabtec Mors Smitt Nieaf-Smitt EazyPhase manual

Wabtec

Wabtec Mors Smitt Nieaf-Smitt EazyPhase manual

WIKA cpd8000-g user manual

WIKA

WIKA cpd8000-g user manual

Tektronix P6209 instruction manual

Tektronix

Tektronix P6209 instruction manual

Burkert 8201 operating instructions

Burkert

Burkert 8201 operating instructions

Emerson Rosemount 751 quick start guide

Emerson

Emerson Rosemount 751 quick start guide

Gasmet Alnab CMM Installation instructions and operating manual

Gasmet

Gasmet Alnab CMM Installation instructions and operating manual

Dräger JM-105 User quick reference guide

Dräger

Dräger JM-105 User quick reference guide

Buchi NIR-Online PA2 Operation manual

Buchi

Buchi NIR-Online PA2 Operation manual

Tektronix 1L10 instruction manual

Tektronix

Tektronix 1L10 instruction manual

Hioki 3506-10 instruction manual

Hioki

Hioki 3506-10 instruction manual

Cargo Data Boomerang 2 use instructions

Cargo Data

Cargo Data Boomerang 2 use instructions

AEMC instruments Chauvin Arnoux 6412 Service/Calibration Manual

AEMC instruments

AEMC instruments Chauvin Arnoux 6412 Service/Calibration Manual

Bosch GLM 80 Professional Operating and safety instructions

Bosch

Bosch GLM 80 Professional Operating and safety instructions

LOVATO ELECTRIC EXP10 40 instruction manual

LOVATO ELECTRIC

LOVATO ELECTRIC EXP10 40 instruction manual

Sierra InnovaSonic 203 instruction manual

Sierra

Sierra InnovaSonic 203 instruction manual

GF 4630 manual

GF

GF 4630 manual

Endress+Hauser Levelflex FMP51 operating instructions

Endress+Hauser

Endress+Hauser Levelflex FMP51 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.