V758P
Instruction and Installation Sheet PXM
Introduction
Follow these instructions when installing, operating, or
servicing the product.
Installation & Operating Instructions:
The Pilot Exhaust Module (PXM) is installed between an
HA (ISO size 01) valve and a manifold segment. This
valve in conjunction with PXM controls the presence of
14 pilot control pressure in a specific pressure zone in
the manifold. This valve and PXM must be mounted in
the pressure zone.
The pressure zone begins at a segment with the left
gasket pilot ports 12 & 14 blocked. The pressure zone
ends at either the right end plate of the manifold or at the
next segment with the pilot ports 12 & 14 blocked. If a
high flow end plate is the end of the pressure zone, the
12 & 14 ports must be plugged in the end plate.
Minimum operating pressure of the HA valve on the PXM
must be present in the main pressure galley (port 1) of
the manifold segment. Valves with pilots controlled in the
pressure zone must be externally piloted to the 14 pilot
port, and 2 position single solenoid valves must have a
spring return mechanism incorporated in the 12 end
return operator. Any valve in this zone configured as
internally piloted or using sandwich regulator will NOT
have their pilot pressure controlled by the PXM.
These conditions will be seen at the externally piloted
valves with solenoids energized and PXM has exhausted
zoned pilot pressure:
•5/2 Single Solenoid valves (with mechanical
spring) will shift to the 12 position.
•5/2 Double Solenoid valves will remain in the
“last energized state".
•5/3 Double Solenoid valves will shift to the
“center position”.
Lubrication
Factory pre-lubed. If lubricating in service, use Parker
F442 oil or equivalent paraffin based mineral oil with 150
to 200 SSU viscosity @100°F.
CAUTION: Do not use oils that are synthetic,
reconstituted, have an alcohol content or a detergent
additive.
Application Limits
These products are intended for use in general purpose
compressed air systems only.
Operating Pressure Range: Maximum 145 PSIG (1000 kPa)
Ambient Temperature Range: -15°C to 49°C (5°F to 120°F
Installation:
Install Pressure
Switch
1. Remove Plug (3)
and Plug Gasket (2)
from body. Separate
the Plug Gasket (2)
from Plug (3).
Item
Description
1
ISO Pilot Exhaust
Module (PXM) Base
2
Plug Gasket
3
Plug
4
Pressure Switch
V758P
Instruction and Installation Sheet PXM
2. Install Plug Gasket (2) to Pressure Switch (4).
3. Install Pressure Switch (4).
4. Using hex wrench, tighten Pressure Switch (4) –
torque 1.5 to 1.7 Nm (13 to 15 in-lb)
Step 1: Install Tie Rods
1. Install two Tie Rods (5) to
the base, torque finger tight.
2. Adjust tie rod height to
28.5/28.0 mm
(1.12/1.10 inch) as figure
shows.
3. If finger tight height exceeds
28.5 mm (1.12 inch), use
mechanical tightening as
necessary to get the proper
height.
Step 2: Install Pilot Exhaust Module
1. Lay the PXM gasket (6) on the base. Make sure the
two rubber projections are face up and the orientation of
the gasket is correct.
2. Engage both tie rods (5) into mounting holes on PXM
body, lower the PXM body.
3. Carefully engage the electrical plug into the base.
4. Continue to lower the PXM body by carefully engaging
the two rubber projections on the gasket into the
appropriate holes on the PXM body.
5. Press the PXM body by hand firmly. To confirm the
gasket is indeed attached to the PXM body, lift the PXM
body by about one half inch. Both rubber projections
should remain in the holes.
6. Lay the PXM body back on the base.
Step 3: Install Valve
1. Locate valve gasket (7) on bottom of valve body (8).
2. Install valve onto PXM.
3. Carefully engage the valve electrical plug.
4. Using hex wrench, tighten two Screws (9) –torque 1.5
to 1.7 Nm (13 to 15 in-lb)
Step 4: Leakage Check
1. Apply pressure to base and check for audible leakage
at various joints. If any are present, do not operate the
valve, repeat the assembly procedure until satisfied.
Figure 1: ISO Pilot Exhaust Module (Valve and Base shown for
reference only)
Component List
The components listed below are for identification
purposes only. Individual components are not sold
separately.
Item
Description
1
ISO Pilot Exhaust Module (PXM) Base
5
Tie Rods
6
Pilot Exhaust Module (PXM) Gasket
7
HA Valve Gasket
8
HA Valve
9
Mounting Screws
Installation & Service Instructions
V758P
PXM, General Installation
ISSUED: November 2019
Supersedes: None
Doc. #V758P, EN# 190862, Rev -

Other Parker Industrial Equipment manuals

Parker Airtek Smart Cycle Plus SCP1200 User manual

Parker

Parker Airtek Smart Cycle Plus SCP1200 User manual

Parker LP28 Series User manual

Parker

Parker LP28 Series User manual

Parker VM24 Series User manual

Parker

Parker VM24 Series User manual

Parker AC20 Series User manual

Parker

Parker AC20 Series User manual

Parker MX45S Series User manual

Parker

Parker MX45S Series User manual

Parker mPR Series Owner's manual

Parker

Parker mPR Series Owner's manual

Parker ETH080 User manual

Parker

Parker ETH080 User manual

Parker IQAN-LC5-C0 Series User manual

Parker

Parker IQAN-LC5-C0 Series User manual

Parker Finite JDK5000V Installation guide

Parker

Parker Finite JDK5000V Installation guide

Parker AC20 Series User manual

Parker

Parker AC20 Series User manual

Parker LX80L User manual

Parker

Parker LX80L User manual

Parker 252 Series User manual

Parker

Parker 252 Series User manual

Parker ETH User manual

Parker

Parker ETH User manual

Parker ASV2000 Series User manual

Parker

Parker ASV2000 Series User manual

Parker PCO2 User manual

Parker

Parker PCO2 User manual

Parker PGP300 Series User manual

Parker

Parker PGP300 Series User manual

Parker KarryFlare User manual

Parker

Parker KarryFlare User manual

Parker KarryFlare User manual

Parker

Parker KarryFlare User manual

Parker Gemini GV6K Series Manual

Parker

Parker Gemini GV6K Series Manual

Parker ES2000 Series User manual

Parker

Parker ES2000 Series User manual

Parker Zander AKM 1 User manual

Parker

Parker Zander AKM 1 User manual

Parker 732 Series User manual

Parker

Parker 732 Series User manual

Parker D-Pak Manual

Parker

Parker D-Pak Manual

Parker SPD 2 User manual

Parker

Parker SPD 2 User manual

Popular Industrial Equipment manuals by other brands

ABB A165-L32 Operation manual

ABB

ABB A165-L32 Operation manual

Bosch Rexroth ABZSS operating instructions

Bosch

Bosch Rexroth ABZSS operating instructions

ABB HT564962 Operation manual

ABB

ABB HT564962 Operation manual

Exatron 923 user manual

Exatron

Exatron 923 user manual

TLV QS10 Series instruction manual

TLV

TLV QS10 Series instruction manual

Mark 7 Evolution user manual

Mark 7

Mark 7 Evolution user manual

Festo YJKP-NGS Operating	 instruction

Festo

Festo YJKP-NGS Operating instruction

Siemens SITRANS SCM IQ Compact operating instructions

Siemens

Siemens SITRANS SCM IQ Compact operating instructions

Genesis GXT 115 reference guide

Genesis

Genesis GXT 115 reference guide

Fröling T4e operating instructions

Fröling

Fröling T4e operating instructions

BIRD TERMALINE 8860 Series Operation manual

BIRD

BIRD TERMALINE 8860 Series Operation manual

riverhawk IM-255 instruction manual

riverhawk

riverhawk IM-255 instruction manual

SixCase SmartCase SC1230 manual

SixCase

SixCase SmartCase SC1230 manual

IFM Electronic AL1300 operating instructions

IFM Electronic

IFM Electronic AL1300 operating instructions

Voltaire 15W/F Installation, operation and maintenance manual

Voltaire

Voltaire 15W/F Installation, operation and maintenance manual

ABB HT604877 Operation manual

ABB

ABB HT604877 Operation manual

ABB SACE Tmax XT manual

ABB

ABB SACE Tmax XT manual

SCHUNK SLD Assembly and operating manual

SCHUNK

SCHUNK SLD Assembly and operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.