2
© 2014 - 2024 Parktron Technology Ltd.
Table of Content
1. Cabinet installation (Entry/Exit Terminal): ....................................................................4
1.1. Shipping package:..................................................................................................4
1.2. Foundation island preparation:..............................................................................5
1.2.1. Suggested dimensions: ..............................................................................5
1.2.2. Power, network cable, control signal & intercom wires: .............................6
1.2.3. Anchor bolts: .............................................................................................6
1.3. Detection loop wire installation:............................................................................8
1.3.1. Suggested loop wire specification: .............................................................8
1.3.2. Loop position and wiring guide: .................................................................8
1.3.3. Ground slot cutting for loop wire installation:............................................9
1.3.4. Loop wire installation instruction:............................................................11
2. Cable & wire connection: ............................................................................................12
2.1. Connect loop wires to loop detectors: .................................................................12
2.1.1. Where are loop detectors? ......................................................................12
2.1.2. Loop wire connection to loop detector: ...................................................12
2.1.3. Loop detector configuration & testing: ....................................................13
2.2. Connect barrier gate to terminal: ........................................................................14
2.2.1. Terminal I/O control board wiring contact points reference: ....................14
2.2.2. Barrier gate wiring diagram (for Parktron barrier AGT210):......................16
2.2.3. For other types of barrier:........................................................................18
2.3. DC power outputs of terminal device & signal inputs: .........................................21
2.3.1. Wiring contacts for fixed functions: .........................................................21
2.3.2. Wiring contacts for software programmable functions: ...........................22
2.4. Intercom wiring reference: ..................................................................................23
2.4.1. Wiring diagram example:.........................................................................23
2.4.2. Parktron intercom sub unit: .....................................................................23
2.4.3. Master unit requirement: ........................................................................24
2.5. Network cable connection:..................................................................................24
2.5.1. Connector location: .................................................................................24
2.6. Input power cable connection: ............................................................................ 25
2.6.1. Terminal input power requirement: .........................................................25
2.6.2. Input power connection location: ............................................................25
3. Power on & configuration: ..........................................................................................26
3.1. Factory default IP addresses: ............................................................................... 26
3.2. Preparation for configuration (How to connect terminal with Putty.exe): ............ 26