DSC MAXSYS RF4164-433 User manual

WARNING: This manual contains information on limitations regarding product
use and function and information on the limitations as to liability of the
manufacturer. The entire manual should be carefully read.
®
RF4164-433 v4.0 • Installation Manual
This RF4164-433 V4.0 receiver version is currently
supported by all PC4020 DLS-3 downloading files.
firealarmresources.com

•The Wireless Device Fail Time (Section [001307]) in the panel is set to 3:00 hours by
default. For a North American 433MHz system, the recommended setting for Device
Fail Time is 24:00 hours. (08:00 hours minimum).
• The Wireless Device Fail Time (Section [001307]) in the panel is set to 3:00 hours by
default. For a 433MHz European system, the recommended setting for the Device Fail
Time is 02:30 hours to meet regulations.
• RF Jam Detect (Section [000200]) in the panel is disabled by default.
This option
needs to be turned ON for UL/ULC/CE installations.
Important Programming Notes
IMPORTANT: This equipment shall be installed by Service Persons only (service person is defined as a person
having the appropriate technical training and experience necessary to be aware of hazards to which that person
may be exposed in performing a task and of measures to minimize the risks to that person or other persons). It
shall be installed and used within an environment that provides the pollution degree max 2, over voltages
category II, in non-hazardous, indoor locations only .
This manual shall be used in conjunction with the Control Panel Installation Manual.
FCC COMPLIANCE STATEMENT
CAUTION: CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY DIGITAL SECURITY CONTROLS
COULD VOID YOUR AUTHORITY TO USE THIS EQUIPMENT.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict
accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It
has been type tested and found to comply with the limits for Class B device in accordance with the specifications
in Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such
interference in any residential installation. However, there is no guarantee that interference will not occur in
a particular installation. If this equipment does cause interference to television or radio reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
•Re-orient the receiving antenna
•Relocate the alarm control with respect to the receiver
•Move the alarm control away from the receiver
•Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional
suggestions. The user may find the following booklet prepared by the FCC helpful: “How to Identify and Resolve
Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office,
Washington, D.C. 20402, Stock # 004-000-00345-4.
The complete R&TTE Declaration of Conformity can be found at
http://www.dsc.com/listings_index.aspx.
firealarmresources.com

Table of Contents
Introduction 1
1.1 Before You Begin............................................................................... 1
1.2 How to Use This Manual .................................................................. 1
1.3 RF4164-433 Specifications ............................................................... 2
1.4 Wireless Devices ............................................................................... 2
Getting Started 3
2.1 Unpack the RF4164-433 Receiver ..................................................... 3
2.2 Find a Mounting Location for the RF4164-433 ................................ 3
2.3 Connecting the RF4164-433 ............................................................. 3
2.4 Enroll the RF4164-433 ...................................................................... 3
Enroll & Program Wireless Devices 4
3.1 A Note about Electronic Serial Numbers (ESN) ............................... 5
3.2 Enrolling Wireless Detectors ............................................................ 5
3.3 Enrolling and Programming Wireless Keys ..................................... 6
Testing & Mounting Devices 8
4.1 Test the Placement of the Wireless Detectors .................................. 8
4.2 Test Wireless Key Reception .............................................................. 9
4.3 Mount the RF4164-433 Receiver and Wireless Devices .................... 9
Deleting & Replacing Devices 10
5.1 Replacing Devices .......................................................................... 10
5.2 Deleting Devices ............................................................................. 10
5.3 Deleting Device Serial Numbers .................................................... 11
5.4 Deleting a RF4164-433 Module ...................................................... 11
Additional Programming Notes 12
6.1 Device Fail Time ............................................................................. 12
6.2 Trouble Conditions ......................................................................... 12
Troubleshooting 14
Programming Worksheets 15
INDUSTRYCANADASTATEMENT
This class B digital apparatus meets all requirements of the Canadian interference-causing
equipment regulations. Cet appareil mumérique de la Classe B respecte toutes les exigences de
règlement sur le matériel brouilleur du Canada.
The term ‘IC:’ before radio certification number only signifies that Industry Canada technical
specifications were met.
i
firealarmresources.com

WARNING Please Read Carefully
Note to Installers
This warning contains vital information. As the only individual in
contact with system users, it is your responsibility to bring each item
in this warning to the attention of the users of this system.
System Failures
This system has been carefully designed to be as effective as possible.
There are circumstances, however, involving fire, burglary, or other
types of emergencies where it may not provide protection.Any alarm
system of any type may be compromised deliberately or may fail to
operate as expected for a variety of reasons. Some but not all of these
reasons may be:
■■
■■
■
Inadequate Installation
A security system must be installed properly in order to provide
adequate protection. Every installation should be evaluated by a se-
curity professional to ensure that all access points and areas are cov-
ered. Locks and latches on windows and doors must be secure and
operate as intended. Windows, doors, walls, ceilings and other build-
ing materials must be of sufficient strength and construction to pro-
vide the level of protection expected. A reevaluation must be done
during and after any construction activity. An evaluation by the fire
and/or police department is highly recommended if this service is
available.
■■
■■
■
Criminal Knowledge
This system contains security features which were known to be ef-
fective at the time of manufacture. It is possible for persons with
criminal intent to develop techniques which reduce the effective-
ness of these features. It is important that a security system be re-
viewed periodically to ensure that its features remain effective and
that it be updated or replaced if it is found that it does not provide
the protection expected.
■■
■■
■
Access by Intruders
Intruders may enter through an unprotected access point, circumvent
a sensing device, evade detection by moving through an area of insuf-
ficient coverage, disconnect a warning device, or interfere with or
prevent the proper operation of the system.
■■
■■
■
Power Failure
Control units, intrusion detectors, smoke detectors and many other
security devices require an adequate power supply for proper opera-
tion. If a device operates from batteries, it is possible for the batteries
to fail. Even if the batteries have not failed, they must be charged, in
good condition and installed correctly. If a device operates only by
AC power, any interruption, however brief, will render that device
inoperative while it does not have power. Power interruptions of any
length are often accompanied by voltage fluctuations which may dam-
age electronic equipment such as a security system. After a power
interruption has occurred, immediately conduct a complete system
test to ensure that the system operates as intended.
■■
■■
■
Failure of Replaceable Batteries
This system’s wireless transmitters have been designed to provide
several years of battery life under normal conditions. The expected
battery life is a function of the device environment, usage and type.
Ambient conditions such as high humidity, high or low temperatures,
or large temperature fluctuations may reduce the expected battery life.
While each transmitting device has a low battery monitor which iden-
tifies when the batteries need to be replaced, this monitor may fail to
operate as expected. Regular testing and maintenance will keep the
system in good operating condition.
■■
■■
■
Compromise of Radio Frequency (Wireless) Devices
Signals may not reach the receiver under all circumstances which could
include metal objects placed on or near the radio path or deliberate
jamming or other inadvertent radio signal interference.
■■
■■
■
System Users
A user may not be able to operate a panic or emergency switch possi-
bly due to permanent or temporary physical disability, inability to
reach the device in time, or unfamiliarity with the correct operation. It
is important that all system users be trained in the correct operation of
the alarm system and that they know how to respond when the system
indicates an alarm.
■■
■■
■
Smoke Detectors
Smoke detectors that are a part of this system may not properly alert
occupants of a fire for a number of reasons, some of which follow.
The smoke detectors may have been improperly installed or posi-
tioned. Smoke may not be able to reach the smoke detectors, such
as when the fire is in a chimney, walls or roofs, or on the other side
of closed doors. Smoke detectors may not detect smoke from fires
on another level of the residence or building.
Every fire is different in the amount of smoke produced and the
rate of burning. Smoke detectors cannot sense all types of fires
equally well. Smoke detectors may not provide timely warning of
fires caused by carelessness or safety hazards such as smoking in
bed, violent explosions, escaping gas, improper storage of flam-
mable materials, overloaded electrical circuits, children playing
with matches or arson.
Even if the smoke detector operates as intended, there may be circum-
stances when there is insufficient warning to allow all occupants to
escape in time to avoid injury or death.
■■
■■
■
Motion Detectors
Motion detectors can only detect motion within the designated areas
as shown in their respective installation instructions. They cannot dis-
criminate between intruders and intended occupants. Motion detec-
tors do not provide volumetric area protection. They have multiple
beams of detection and motion can only be detected in unobstructed
areas covered by these beams. They cannot detect motion which oc-
curs behind walls, ceilings, floor, closed doors, glass partitions, glass
doors or windows. Any type of tampering whether intentional or un-
intentional such as masking, painting, or spraying of any material on
the lenses, mirrors, windows or any other part of the detection system
will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in tem-
perature. However their effectiveness can be reduced when the ambi-
ent temperature rises near or above body temperature or if there are
intentional or unintentional sources of heat in or near the detection
area. Some of these heat sources could be heaters, radiators, stoves,
barbeques, fireplaces, sunlight, steam vents, lighting and so on.
■■
■■
■
Warning Devices
Warning devices such as sirens, bells, horns, or strobes may not warn
people or waken someone sleeping if there is an intervening wall or
door. If warning devices are located on a different level of the resi-
dence or premise, then it is less likely that the occupants will be alerted
or awakened. Audible warning devices may be interfered with by
other noise sources such as stereos, radios, televisions, air condition-
ers or other appliances, or passing traffic. Audible warning devices,
however loud, may not be heard by a hearing-impaired person.
■■
■■
■
Telephone Lines
If telephone lines are used to transmit alarms, they may be out of
service or busy for certain periods of time. Also an intruder may cut
the telephone line or defeat its operation by more sophisticated means
which may be difficult to detect.
■■
■■
■
Insufficient Time
There may be circumstances when the system will operate as intended,
yet the occupants will not be protected from the emergency due to
their inability to respond to the warnings in a timely manner. If the
system is monitored, the response may not occur in time to protect the
occupants or their belongings.
■■
■■
■
Component Failure
Although every effort has been made to make this system as reliable
as possible, the system may fail to function as intended due to the
failure of a component.
■■
■■
■
Inadequate Testing
Most problems that would prevent an alarm system from operating as
intended can be found by regular testing and maintenance. The com-
plete system should be tested weekly and immediately after a break-
in, an attempted break-in, a fire, a storm, an earthquake, an accident,
or any kind of construction activity inside or outside the premises.
The testing should include all sensing devices, keypads, consoles, alarm
indicating devices and any other operational devices that are part of
the system.
■■
■■
■
Security and Insurance
Regardless of its capabilities, an alarm system is not a substitute for
property or life insurance. An alarm system also is not a substitute for
property owners, renters, or other occupants to act prudently to pre-
vent or minimize the harmful effects of an emergency situation.
ii
firealarmresources.com

1
The RF4164-433 is a wireless signal receiver for use with Maxsys PC4020 panels. The
RF4164-433 receives signals from DSC 433MHz wireless devices.
Install up to eight RF4164-433 v4.0 receivers: If you are installing a PC4020 or
higher system, you can enroll up to eight RF4164-433 wireless receivers. This will
give you a greater range in which to install wireless devices. It will also allow you to
install backup wireless receivers with overlapping ranges, to provide increased security
for the wireless zones on the system.
1.1 Before You Begin
This manual describes how to install, program and maintain the RF4164-433 v4.0 on
a PC4020 Security System. You should have completed the following steps in your
PC4020 installation before you install the RF4164-433 module:
1. Plan the installation and wiring of the PC4020 system (see PC4020
Installation
Manual
, Section 2: Installation and Wiring)
2. Install the control panel and at least one keypad to use for programming (see
PC4020
Installation Manual
, Section 3: How to Program)
3. Install and enroll all hardwired zone expander modules (PC4108 or PC4116) (see
PC4020
Installation Manual
, Section 4: Module Enrollment).
You can program the RF4164-433 from a PC4020 system LCD keypad or using DSC
downloading software (DLS-3 or higher). See the PC4020
Installation Manual
,
Section 3 “How to Program”.
1.2 How to Use This Manual
To install and set up the RF4164-433 and wireless devices, follow these steps:
1. Enroll and temporarily mount the RF4164-433 module (see
Section 2
)
2. Enroll and program wireless devices using zones and wireless keys (see
Section 3
)
3. Complete zone and other programming on the system (see
Sections 4 and 5)
4. Test the placement of all the wireless devices
(see Section 6)
5. Permanently mount the RF4164-433 receiver and wireless devices
(see Section 6)
To replace or delete wireless devices already enrolled, see
Section 4.
For additional information on wireless motion detectors and wireless keys, see
Sections
7 and 8.
For help with troubleshooting, see
Section 9.
Record the zone or slot and serial numbers of all wireless devices, and other programming
in the
Programming Worksheets
section at the end of the manual.
PC4020 Programming
All programming sections in this manual are referred to by reference number. A detailed
description of PC4020 programming is in the PC4020
Installation Manual
, section 3
“How to Program.”
To program using reference numbers, enter Installer’s programming ([✱][8][Installer’s
Code]). Press and hold the [A]uxiliary key until the keypad displays the following
message:
“Enter Ref # then ✱.”
S E C T I O N 1
Introduction
firealarmresources.com

2
Enter the reference number found in the Programming Worksheets for the section
you wish to program, then press the [✱] key. The display will immediately go to the
programming item you have selected.
1.3 RF4164-433 Specifications
• Up to eight RF4164-433 receivers can be installed per PC4020 v3.2 or higher
system.
• Nominal current draw of 35mA
• Frequency: 433 MHz
• Receives signals from up to 64 wireless zones on a PC4020 v3.2 and later
• Programmable supervisory window, programmable hours from 01:00 to 23:59
• Location
- can be wired up to 750 ft. / 230 m from the main panel with 22 gauge wire
- connects to Combus
- for longer wire runs, thicker gauge wire must be used.
1.4 Wireless Devices
Please refer to the Installation Instruction sheets of the following devices for more information.
The RF4164-433 v4.0 can receive signals from the following devices:
• WLS912L-433 Glass Break Detector
• WLS914-433 Pet Immune PIR
• WS4904 Motion Detector
• WS4904P Pet Immune PIR
• WS4916 Smoke Detector
• WS4938 Panic Button
• WS4945 Mini Door/Window Contact
• DV-WS4975 Vanishing Contact
• WS4939 Wireless Key
• WS4949 2-Button Wireless Key
• WS4959 5-Button Wireless Key
• WS4969 Wireless Key with LED
I N T R O D U C T I O N
firealarmresources.com

3
S E C T I O N 2
This section describes how to set up and enroll the RF4164-433 module.
2.1 Unpack the RF4164-433 Receiver
Check that the following parts are in your RF4164-433 package:
Diagram 1
• RF4164-433 PCB
• RF4164-433 plastic cabinet
2.2 Find a Mounting Location for the RF4164-433
NOTE: Do not permanently mount the RF4164-433 now. Mount the RF4164-433 receiver after you
have done placement tests with all the wireless devices (see sections 4.1 and 4.2).
Find a place that is:
• Dry
• Central to the proposed placement of all wireless devices
• As high as possible
• Far from sources of interference, including: electrical noise such as computers,
televisions and electric motors in appliances and heating and air conditioning
units; large metal objects like heating ducts and plumbing which may shield the
antenna.
Make sure that electrical wires will not run over the case of the module when it is
mounted.
When mounting the RF4164-433 in a basement, place the module as high and as
close to the underside of the first floor as possible. The range of the module will be
reduced if the unit is mounted below ground level.
2.3 Connecting the RF4164-433
The RF4164-433 is connected to the control panel
via the Combus.
CAUTION: Remove all power from the panel while
connecting modules to the Combus.
Wire the RF4164-433 to the Combus of the PC4020
according to diagram 1:
2.4 Enroll the RF4164-433
You must enroll one RF4164-433 module with the PC4020 panel before you can
install and program the wireless devices.
If you are installing a PC4020 v3.2 or higher, you can enroll up to eight RF4164-433
wireless receivers. This will give you a greater range in which to install wireless
devices. It will also allow you to install backup wireless receivers with overlapping
ranges, to provide increased security for the wireless zones on the system.
NOTE: The maximum number of wireless zones you can enroll on the PC4020/16128 is 64,
even if you install more than one RF4164-433 wireless receiver.
Combus to
PC4010/PC4020/P-16128
Main Control Panel
Getting Started
RF4164-433RF4164-433
RF4164-433RF4164-433
RF4164-433
firealarmresources.com

4
G E T T I N G S T A R T E D
NOTE: You cannot have more than 128 zones on the PC4020. If the total number of zones
theoretically available on the zone expanders exceeds the maximum for the panel, you will not
be able to use the extra zones.
A description of how to enroll keypads and modules is in your PC4020
Installation
Manual.
Follow these steps to enroll your RF4164-433 module.
1. At a PC4020 system LCD keypad, enter [✱][8][Installer’s Code] to go to the
Installer’s Programming section.
2. Enter Ref #[0200], to go to the Enroll Module section.
3 Scroll to PC41xx Zn. Ex., press [✱]. The LCD keypad will display Create Tamper
on Desired Unit.
4. Tamper the RF4164-433:
i) Remove the cover of the RF4164-433
ii) Press the case tamper switch located to the right of the terminal strip and
release
NOTE: If equipped, the wall tamper will also need to be depressed with the case tamper.
However, it does not need to be released to complete the enrollment.
5. The LCD keypad will display RF4164-433 Zn. Ex. Mod XX Enrolled. Record the
module number of the RF4164-433 receiver in the
Programming Worksheets
.
6. When the module is enrolled, re-secure the connection between the T1 and T2
terminals.
7. To enroll another RF4164-433 module, repeat steps 2 to 6. To exit module
enrollment, press [#].
The RF4164-433 module is now installed and enrolled on the PC4020 system. You can
now enroll and program the wireless devices (see Section 3).
firealarmresources.com

5
S E C T I O N 3
Enroll & Program Wireless Devices
This section describes how to enroll and program wireless devices.
For more information,
read the instruction sheet included with each device.
3.1 A Note about Electronic Serial Numbers (ESN)
In order to reduce the occurrence of wireless devices with the same serial number, 6-
digit serial numbers are now printed on the back of each wireless device. The 6-digit
serial numbers include hexadecimal digits. For instructions on programming
hexadecimal numbers, see your
PC4020 Installation manual, section 3: How to
Program
.
Older wireless devices will only have 5-digit serial numbers. To enroll these devices,
enter [0], then the 5-digit serial number.
3.2 Enrolling Wireless Detectors
NOTE: Before you permanently mount wireless devices, test each one in its intended mounting
location to make sure that it can communicate properly with the RF4164-433. Test the device at
least 3 times. See Section 4.1 for more information.
1. At a system LCD keypad, enter [✱][8][Installer’s Code].
2. Enter Ref #[001300] to go to the Enroll Device programming section.
This section will only be available if you have already enrolled the RF4164-433
module with the panel (see
Section 2.5
).
The LCD keypad will display Enroll Device Serial # [ ].
3. Look at the back of the first wireless device you want to enroll. If the device has a 6-digit
serial number, enter it now. If the device only has a 5-digit number, enter a [0] and then
the 5-digit number.
4.
PC4020 v3.2 and higher panels:
The LCD keypad prompts Enroll Device Zone XXX.
Enter a 3-digit zone number for the device.
NOTE: If the zone selected is a hardwired zone, the wireless zone will replace it. However,
you cannot replace an AML or PC4820 zone with a wireless zone. If you select an AML or
PC4820 zone, the keypad will sound an error tone.
5. The LCD keypad will display Enroll Device Serial # [ ]. Continue with steps 3 and
4 until all devices have been enrolled.
6. To exit device enrollment, press [#].
Program Partitions and Zones
Now that you have enrolled and mounted the wireless devices, you should program
your PC4020 partitions and zones. See your
PC4020 Installation Manual, section 5:
Partitions and Zones
.
firealarmresources.com

6
3.3 Enrolling and Programming Wireless Keys
For wireless keys to work on the system, you need to enroll them and then program
the function buttons. You can enroll up to 16 wireless keys on the RF4164-433
receiver.
Step 1: Enrolling Wireless keys
1. At a PC4020 system LCD keypad, enter [✱][8][Installer’s Code] to go to the
Installer’s Programming section.
2. Enter Ref #[001300], to go to the Enroll Device programming section. This section
will only be available if you have already enrolled the RF4164-433 module with
the panel (see
Section 2.6
). The LCD keypad will display
Enroll Device Serial # [ ].
3. Look at the back of the wireless key. If it has a 6-digit serial number, enter it
now. If it only has a 5-digit number, enter a [0] and then the 5-digit number.
4. The display will show Enroll Device WKEY #XX, where XX = the Wkey slot to
which the wireless key is assigned (01 to 16).
5. Record the serial number and assigned slot number in the programming
worksheets in the back of this manual.
6. Continue with steps 3 to 5 until all wireless keys have been enrolled.
Wireless Key Reporting
When you enroll a wireless key, the panel will assign a user number (0101 to 0116) to the
key. The wireless key enrolled in slot 01 will be given user number 0101, slot 02 will
have user number 0102, and so on. This allows the panel to transmit and log the arm/
disarm events performed by each wireless key.
You can still program access codes for user numbers 0101 to 0116.
For example:
User 0101 arms or disarms using an access code - the panel transmits and logs
Closing/
Opening User 0101
.
A user arms or disarms using wireless key 01 - the panel transmits
Closing/Opening User
0101
and logs
Closing/Opening User 0101
AND
Closing/Opening WKey #01
.
Step 2: Program the Wireless Key Function Buttons
All wireless keys have four programmable function buttons. When you press and hold
a button for two seconds, the programmed function will be executed. Each function
button can be assigned to one partition.
NOTE: Wireless key function buttons will not work when the partition(s) to which they are
assigned are being accessed for zone bypassing or programming.
1. From Installer’s Programming, enter Ref #[001304], to go to WLSKey Functions.
2. Scroll to the slot number of the key you want to program (01-16). Press [✱].
3. Scroll to the number of the button you want to program (1-4). Press [✱].
I N S T A L L I N G W I R E L E S S D E V I C E S
firealarmresources.com

7
4. Enter the 2-digit number of the function you want to select, or scroll to the
function you want to assign to that button and press [✱]. The following
functions may be programmed:
00 Null Key 07 Arm Interior
01 Stay Arm 08-15 [✱][7] Command Outputs 1-8
02 Away Arm 16 Fire Alarm
03 No-Entry Arm 17 Auxiliary Alarm
04 Chime On/Off 18 Panic Alarm
05 System Test 19 Disarm (Off)
06 Quick Exit
NOTE: If programmed, these options do not require access code entry regardless of other
system options. The programmed function will be executed immediately.
5. The LCD keypad will show Select (01) Partition 1. Scroll to the partition you want
the button to work in and press [✱] to select.
6. Repeat steps 3 to 5 until all the buttons are programmed.
7. Repeat steps 4 to 6 until all the wireless keys are programmed.
8. To exit, press [#].
NOTE: When a wireless key is used to disarm a partition, all courtesy pulse outputs enabled
for that partition will activate for two minutes.
Now that you have enrolled and programmed all the wireless devices, you will need to
test the devices and mount wireless devices using zones. See section 4 for more
information.
I N S T A L L I N G W I R E L E S S D E V I C E S
firealarmresources.com

8
You should test each device you have enrolled to ensure good signal strength between
the devices and the RF4164-433 receiver. Follow the instructions in this section to
test wireless devices which use zones, wireless keys and handheld keypads.
If several wireless devices produce BAD test results, you may need to move the RF4164-433 to a
better location (see section 2.3 for tips on finding a location for the RF4164-433 module).
4.1 Test the Placement of the Wireless Detectors
It is very important to test each wireless device before it is mounted. Following these
steps will test the placement of WLS904/WLS904P(L)-433, WLS906-433, WLS907(T)-
433, WLS912L-433, WLS914-433 (North America only), WLS925L-433 & WLS935L-433
wireless devices, based on the signal strength between the RF4164-433 module and
the device:
NOTE: You cannot test the wireless key in this mode. See section 4.2 for instructions on
testing wireless keys.
1. Temporarily place the device in its intended mounting location.
2. At a system LCD keypad, enter [✱][8][Installer’s Code].
3. Enter Ref # [001303] to go to the Device Test section.
4. Enter [00] to have test results sounded on the keypad buzzers only. Enter [01] to
have test results sounded by the system bells, as well as the keypad buzzers.
5. Use the [<][>] keys to scroll to the device number and press [✱] to select it. The
keypad will display Activate Device.
6. Activate the device being tested. A result will be displayed on the keypad or sounded
by the keypad or bell.
WLS904-433/WLS904P(L)-433/WLS914-433 (N. A. only): Remove the detector from
the backplate, wait for the result to be presented, then reattach the detector to its
backplate.
WS4916: Hold the supplied magnet near the raised line on the outer rim of the
bracket. Wait for the result to be presented. The magnet can now be removed
and the next result must be waited for.
WS4945/DV-WS4975: Open the contact by moving the magnet away from the
unit. If the unit is attached to a door or a window, open the door or window to
activate the device. Wait for the result to be presented. Close the contact by
moving the magnet near the unit. If the unit is attached to a door or a window,
close the door or window to restore the device. Wait for the result to be presented.
WLS912L-433: Press and hold the test mode tab. Wait for the result to be
presented. Release the test mode tab. Wait for the result to be presented.
7. Read the placement test results:
Placement LCD Keypad Display Keypad Buzzer/ Bells
Good Good 1 Beep/squawk
Fair Fair 2 Beeps/squawks
Bad Bad 3 Beeps/squawks
Activate the device until you get 3 good or fair in a row. Wait for the result to be
presented between each test on the same device. You may mount your device where
results were good or fair.
S E C T I O N 4
Testing & Mounting Devices
firealarmresources.com

9
For PC4020 v3.2 system, the system keypad will also display the number of RF4164-
433 receivers that reported the highest level result (e.g., “Placement Good by 2
Receivers”).
Devices indicating a bad result must be moved to another location. You may
only have to move the device a few inches to correct a bad result.
NOTE: Do not mount any device where a “bad” test result was indicated.
If several wireless devices produce BAD test results, you may need to move the
RF4164-433 receiver to a better location (see section 2.3 for tips on finding a
location for the RF4164-433).
8.
To test another device, press [#] once, then repeat steps 4 to 7. Continue to test the devices
until both the RF4164-433 receiver and the devices are in good or fair locations.
9. To exit Installer Programming, press [#].
4.2 Test Wireless Key Reception
The wireless key (WLS909-433/WLS919-433) cannot be tested using the module
placement test described above. To ensure that the RF4164-433 is receiving
transmissions from these devices, conduct the following tests:
Use the function keys to arm and disarm the system at several different points in
the installation.
NOTE: Do not use a Fire, Auxiliary or Panic key to test your WLS9X9-433, as pressing these
buttons will always notify your central station of a nonmedical emergency.
If these devices do not operate from all points in the installation, you will need to move the
RF4164-433 receiver. Moving the RF4164-433 higher will usually improve the reception.
If you move the RF4164-433 receiver, repeat the tests described in sections 4.1 and
4.2 on all the wireless devices. Continue to test the devices until you have found
locations with good or fair placement results for all wireless detectors, and there is
acceptable range between the RF4164-433 and the WLS9X9 devices.
4.3 Mount the RF4164-433 Receiver and Wireless Devices
Do not permanently mount the RF4164-433 until you have tested reception with all
the wireless devices (see sections 4.1 and 4.2). Once you have done this and have a
good location, mount the RF4164-433:
1. Remove the four screws that attach the RF4164-433 module to the plastic cabinet.
2. Pull the Combus wires through the hole at the back of the cabinet.
3. Mount the cabinet securely to the wall.
4.
Reattach the RF4164-433 module to the mounted cabinet using the 4 mounting screws.
Mount the Wireless Detectors
If you have conducted the placement test described in section 4.1 and got 3 “Good”
or “Fair” results in a row for each device, you can mount the wireless devices. See the
installation sheet for each device for mounting instructions.
T E S T I N G & M O U N T I N G D E V I C E S
firealarmresources.com

10
If a device is not working, or you need to change the setup of the system, you may need to
replace or delete wireless devices. Follow the appropriate procedure in this section.
5.1 Replacing Devices
1. At a system LCD keypad, enter [✱][8][Installer’s code].
2.
Enter Ref #[001302] to go to the Replace Device section. The LCD keypad will display
Serial # [ ] and either
Zone XXX, Wkey# XX
3. Use the [<][>] keys to scroll to the device to be deleted, then press [✱]. The LCD
keypad will display
With Device
Serial# [ ].
4. Enter the serial number of the new device. The LCD keypad will display Device
Replaced Serial # [ ] Zone XXX
NOTE: You cannot replace devices of different classes. (For example, a motion detector cannot
be replaced by a universal transmitter.) If you need to do this, you must delete the first device
(see ‘Deleting Devices’ below) and enroll the second. You will also need to change the
programming for the new device. See Section 3: ‘Enrolling and Programming WLS9XX
Wireless Devices’.
5. To exit, press [#].
5.2 Deleting Devices
This section describes how to delete any of the enrolled wireless devices from the
RF4164-433 receiver, and from the system.
1. At a system LCD keypad, enter [✱][8][Installer’s Code].
2. Enter Ref #[001301] to go to the Delete Device section. The LCD keypad will
display
Serial # [ ] and either
Zone Label XXX, Wkey# XX
3. Use the [<][>] keys to scroll to the device you want to delete; then press [✱].
The bottom line of the display will read Device Deleted.
4. To exit, press [#].
If you enroll a device of the same class as the one deleted (See ‘Replacing Devices’,
above) it will be placed in the old device’s slot.
S E C T I O N 5
Deleting & Replacing Devices
firealarmresources.com

11
Make sure you update the programming for each device you enroll.
5.3 Deleting Device Serial Numbers
Entering this programming section will erase the serial numbers of all the wireless
devices.
Zone and partition programming will not be affected. When you reenroll the wireless
devices, remember to change the zone and partition programming, if necessary.
1. At an LCD keypad, enter [✱][8][Installer’s Code].
2. Enter Ref #[001308], to go to Default Wireless and press [✱].
3. The LCD will display Confirm Default Press ‘✱’. To confirm the default procedure,
press [✱]. To cancel the default procedure, press any other key.
5.4 Deleting a RF4164-433 Module
To delete a RF4164-433 module, enter the following at any enrolled keypad:
1. Enter Installer’s Programming by pressing [✱][8][Installer’s Code].
2. Enter reference number [0201] to go to Delete Device, then press [✱].
3. Scroll through the different modules, type and select PC41XX. Press [✱] to select.
4. Scroll to the correct module type, then to the correct module number. For example,
to delete RF4164-433 module 04, scroll to “PC41XX (04).” Press the [✱] key to
delete the module.
NOTE: If you are removing all RF4164-433 modules from the system, you will need to
perform a wireless default BEFORE you delete the last module. If you do not, the hardwired
zones may not work correctly. (See section 5.3 ‘Erasing Device Serial Numbers’ above.)
D E L E T I N G & R E P L A C I N G D E V I C E S
firealarmresources.com

12
6.1 Device Fail Time
When supervision of a wireless detector is turned ON, the panel will show a trouble if a
wireless zone stops working or is removed from the system. When supervision is turned
OFF, the panel will not show a trouble.
NOTE: Wireless keys are NOT supervised.
A
zone supervisory
is a test transmission that each wireless zone sends to the RF4164-433
receiver. When the RF4164-433 module receives the supervisory transmission from the zone,
the RF4164-433 module will transmit this information to the control panel.
If the control panel does not get a supervisory transmission from a zone within the
Device Fail time, the zone will be considered “missing”, causing a Device Fault.
The next supervisory transmission that the RF4164-433 receives from the “missing”
zone will restore communication with that zone and restore the Zone Supervisory Fault.
The Device Fail timer will also be reset.
Change the Supervision Option
1. At an LCD keypad, enter [✱][8][Installer’s Code].
2. Enter Ref #[001306] to go to the Supv Window section.
3. Devices are listed by zone number in the order in which they were enrolled.
Scroll to each device. Press [✱] to turn the supervision option ON or OFF for that
device.
4. To exit, press [#].
Change the Device Fail Time
The default amount of time is 3 hours.
NOTE: This must be changed to 24 hours for systems using North American devices.
1. At an LCD keypad, enter [✱][8][Installer’s Code].
2. Enter Ref #[001307] to go to the Device Fail Time section.
3. Enter the time as [HHMM] (valid entries 01:00 - 23:59).
4. To exit, press [#].
6.2 Trouble Conditions
The PC4020 always watches for possible trouble conditions. If a trouble condition
occurs, the LCD keypad “Trouble” light will turn on and the keypad will beep. Press
[✱][2] to display the trouble conditions.
S E C T I O N 6
Additional Programming Notes
firealarmresources.com

13
The following trouble conditions apply to the RF4164-433 receiver. For a description
of all troubles, please see
Section 16 “Diagnostics and Troubleshooting
” in the PC4020
Installation Manual.
• RF4164-433 Tamper • Smoke Low Sense
• RF Jam Detected (see below) • Device Low Batt
• Device Fault (see section 6.1)
Wireless Device Low Battery Trouble Transmission Delay
When a device reports a low battery trouble, the keypad will indicate the trouble
immediately, but the panel will delay transmission of the trouble to the monitoring
station. You can program the length of the delay (in days) in Installer’s Programming.
If the user does not correct the low battery condition before the delay expires, the
low battery trouble will be transmitted.
The low battery alarm and restoral codes will only be reported once per armed period.
The low battery restore transmission is not delayed. The default transmission delay is 7
days.
To change the transmission delay:
1. At an LCD keypad, enter [✱][8][Installer’s code].
2. Enter Ref #[00040211] to go to the 4164 Low Bat Dly section.
3. Enter the new transmission delay (from 000 to 255 days).
4. To exit, press [#].
Replacing Batteries in Wireless Devices
1. Remove the cover of the device from its backplate. This creates a tamper condition
on the zone.
2. Refer to the battery installation instructions on the installation sheet of each
component. Ensure the proper orientation of the batteries as you install them.
3. When the fresh batteries are in place, reattach the cover to the backplate. The tamper
is restored and the zone sends a battery trouble restoral signal to the RF4164-433
receiver. The battery trouble is now clear.
NOTE: When batteries in one device need to be replaced, the batteries in all devices should be
replaced at the same time.
Enable RF Jam Detect Trouble
The RF Jam Detect trouble condition will be generated and logged when the
RF4164-433 module detects an attempt to block RF signals. This tells the user that
the RF4164-433 module is not receiving wireless device transmissions. The panel
will transmit the General System Trouble reporting code.
To enable warning of this trouble condition (The default setting for this option is OFF):
1. At an LCD keypad, enter [✱][8][Installer’s Code].
2. Enter Ref #[000200] to go to the System Toggles section.
3. Scroll to RF Jam Detect.
4. Press [✱] to toggle the option ON or OFF.
5. To exit System Toggles, press [#}.
NOTE: Devices must be placement tested as ‘Good’ or ‘Fair’ for RF Jam Detection to work
properly.
NOTE: This option must be turned on for UL/ULC/CE installations.
A D D I T I O N A L P R O G R A M M I N G N O T E S
firealarmresources.com

14
Troubleshooting
S E C T I O N 7
1. When I enter [0013] RF4164-433 options, the keypad gives me a
long beep.
You cannot enter ESNs unless the RF4164-433 wireless receiver is enrolled. See section
2 for instructions on enrolling the RF4164-433 module.
2. I have entered the ESN for the device but when I violate the
device, the zone does not show open on the keypad.
Check the following:
• Check that you are looking at a keypad on the same partition as the device you are testing
• Check that the ESN has been entered correctly
• Check that the zone is assigned to one or more partitions
3. When I try a module placement test I get no result or “Bad” results.
Check the following (see sections 4.1 and 4.2 for more information on testing devices):
• Verify that you are testing the correct zone
• Verify that the correct ESN was entered when the device was enrolled
• Verify that the device is in range of the RF4164-433 receiver. Try testing the
device in the same room as the receiver
• Confirm that the RF4164-433 receiver is properly connected to the Combus (see
section 2 for RF4164-433 receiver setup and wiring instructions)
• Check that you are testing the zone correctly (see sections 4.1 and 4.2 for testing
instructions)
• Check that the batteries are working and installed correctly
• Look for large metal objects that may be preventing the signal from reaching
the RF4164-433 receiver
The device must be located where consistent “Good” or “Fair” results are obtained. If
several devices show “Bad” results, or if panic pendants and wireless keys operate
inconsistently, move the receiver. See section 2.3 for tips on choosing a mounting location
for the RF4164-433 receiver.
4. The LED on the motion detector does not turn on when I walk in
front of the unit.
The LED is for walk test purposes only. See your WLS904(L)-433
Instruction Sheet
for wa
k test instructions.
firealarmresources.com

15
Programming Worksheets
S E C T I O N 4
[001300] Enroll Wireless Detector (see section 3.2)
• Default = 000000
• 6-digit entry is required; for 5-digit serial numbers, enter [0], then the number
(See section 3.1 “A Note About Electronic Serial Numbers”.)
Serial Number Zone
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
Serial Number Zone
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
l
_____l
_____l
_____l
_____l
_____l
_____ll
_____l
_____l
_____l
firealarmresources.com

16
P R O G R A M M I N G W O R K S H E E T S
WLS9X9 Wireless Key Options (see section 3.3)
[001300] Enroll Device Default = 000000
Wi r eless Serial W i reless Serial
Key No. No. Key No. No.
01
l
_____l
_____l
_____l
_____l
_____l
_____l
09
l
_____l
_____l
_____l
_____l
_____l
_____l
02
l
_____l
_____l
_____l
_____l
_____l
_____l
10
l
_____l
_____l
_____l
_____l
_____l
_____l
03
l
_____l
_____l
_____l
_____l
_____l
_____l
11
l
_____l
_____l
_____l
_____l
_____l
_____l
04
l
_____l
_____l
_____l
_____l
_____l
_____l
12
l
_____l
_____l
_____l
_____l
_____l
_____l
05
l
_____l
_____l
_____l
_____l
_____l
_____l
13
l
_____l
_____l
_____l
_____l
_____l
_____l
06
l
_____l
_____l
_____l
_____l
_____l
_____l
14
l
_____l
_____l
_____l
_____l
_____l
_____l
07
l
_____l
_____l
_____l
_____l
_____l
_____l
15
l
_____l
_____l
_____l
_____l
_____l
_____l
08
l
_____l
_____l
_____l
_____l
_____l
_____l
16
l
_____l
_____l
_____l
_____l
_____l
_____l
[001304] Wireless key Functions Default = 00
Key Button Partition Button Partition Button Partition Button Partition
No. 1 No. 2 No. 3 No. 4 No.
01
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
02
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
03
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
04
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
05
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
06
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
07
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
08
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
09
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
10
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
11
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
12
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
13
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
14
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
15
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
16
l
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________ll
_____l
_____ll
_________l
*Enter partition number 1-8
Wireless Key Function Key Options
00 Null Key 16 Fire Alarm
01 Stay Arm 17 Auxiliary Alarm
02 Away Arm 18 PanicAlarm
03 No-EntryArm 19 Disarm(Off)
04 Chime On/Off 20 Quick Bypass
05 System Test 21 Music Input
06 Quick Exit 22 T-code
07 Arm Interior 23 ZoneControl
08-15 [✱][7] Command Outputs 1-8
firealarmresources.com
Table of contents
Other DSC Security Sensor manuals

DSC
DSC ws8904 User manual

DSC
DSC GS3050-A User manual

DSC
DSC Force2 F2-200 Series User manual

DSC
DSC PG9984(P) User manual

DSC
DSC Encore PEC-300DP User manual

DSC
DSC The NEW FORCE 2 F2-210 User manual

DSC
DSC F2-220 User manual

DSC
DSC Bravo 6 User manual

DSC
DSC PowerG PG9985 User manual

DSC
DSC LC-102PIGBSS User manual
Popular Security Sensor manuals by other brands

Eaton
Eaton CEAG 6811 LED CGLine+ Mounting and operating instructions

TELECO AUTOMATION
TELECO AUTOMATION TVTXS868A02 instruction manual

Vemer
Vemer Sensor-T user manual

Pfeiffer Vacuum
Pfeiffer Vacuum MiniTest 300 operating instructions

Interlogix
Interlogix TX-2413-03-1 Installation sheet

Visonic
Visonic TOWER 20 AM MCW installation instructions