Pecron P600 User manual

www.pecron.com
User manual for outdoor power station P600
PORTABLE POWER STATION

PORTABLE POWER STATION

Contents
1. Introduction
2. Technical Specifications
3. Control Panel and Features
4. Working Guidelines
5. Warranty
PORTABLE POWER STATION

1. INTRODUCTION
Thank you for purchasing the Pecron P600 portable power station.
The P600 is a portable, multi-use battery powered solar generator. It is
light weight, has a large output capacity and offers a variety of charging
outputs to meet all your needs.
The P600 has a wide variety of uses, in the field, mobile working, outdoor
recreation, camping, emergency use, recharging cell phones and
communication devices and power outage backup.
P600 Outdoor Portable Power Station Highlights
220V/60Hz pure sine wave AC output
DC12V 10A output
USB 5V 3A/9V 2.5A QC 3.0*2 AC output
LED emergency lighting
Supports car charging
Supports solar charging with MPPT controller
Packing List Includes
AC Charging Adapter
Charging Cable
12V Car Charging Adapter
Accessory Bag
User Manual
Please read the following Features and Functions instructions before
using the Portable Power Station to avoid damage to the unit and connected
devices.
Please keep the purchase receipt as a proof of purchase for any warranty
claim.
1
PORTABLE POWER STATION

2. Technical Specifications
This section looks good
Item No.
P600
Rated power
600W
Peak power
1200W
Output voltage
AC 220V/60Hz pure sine wave
DC12-14V10A
USB QC3.0 5V3A/9V2.5A
Type-c 5V3A/9V3A/12V2.25A
Battery capacity
578Wh(25.2V22.95Ah)
Battery type
Lithium ion
Charging time
2~3h
Charging voltage
DC29.4V9AMAX
Car and solar
charging
DC12V cigarette lighter/18V solar panel (open
circuit voltage is 22V and the total input is maximum
100W)
Protection
Over-Voltage, Low-Voltage, Over-Temperature
Over-Load, Short-Circuit
Working
temperature
0℃~45℃for (charging)
-20℃~45℃for (discharging)
LED light
LED 2W
Product size
L280*W152*H225mm
Net weight
13lbs(5.9Kg)
2
PORTABLE POWER STATION

3. Control Panel and Features
Please read the following instructions before using the Portable Power
Station to avoid damage to the unit and connected devices.
Packing List
.Charging Adapter
.Charging Cable
.Accessory Bag
.User Manual
3
PORTABLE POWER STATION
2
34 5
1
Display
Panel
DCPower
Button
ACPower
Button
USB
ports
DC 12V
Socket

4
PORTABLE POWER STATION
1
2
3
4
5
DC12V Socket (#5): Supports 12-14V DC output with a
maximum output of 10A.Provides overload and short circuit
protection.
USB QC3.0 Ports (#4): Supports 5V / 9A fast charging
(5V for maximum 3A or 9V for maximum 2.25A)
Provides overload and short circuit protection.
USB-C Ports (#4): Supports 5V / 9A / 12V fast charging.
(5V/9A for maximum 3A, or 12V for maximum 2.25A)
Provides overload and short circuit protection.
AC power button: To activate the AC outlets - press and
hold the AC button (#3) for one second. The screen will turn
on and the AC outlets (#8-9) will be active. To turn off- press
and hold the AC button for 2-3 seconds. The screen will turn
off and the 220 AC outlets will be deactivated.
DC power button: To activate the DC output ports - press
and hold the DC button (#2) for one second. The LCD
screen will turn on and the USB ports (#4) and DC 12V
socket (#5) will be active. To turn off - press and hold the
DC button (#2) for 2-3 seconds. The LCD screen will turn
off and the USB and DC 12V socket will be deactivated.
LCD display
No. Features
Note: Reset - In case of crash or abnormal display, press and hold the AC
button for 14 seconds to reset.

PORTABLE POWER STATION
INPUT PORTS A/C OUTPUT
6 7 8 9
12/18V DC
Solar/car
Charger
29.4V - 9A
Wall Charger
220V output plugs
No.
Description
6
DC5521 Input Port (#6): Supports voltage input from 12 - 18
volts. For solar charging and car charging with maximum input of
100 watts. Port is MPPT controller regulated.
(use manufactures provided car charging adapter only)
7
DC GX16-4 Input Port (#7): Charging port for factory
supplied wall charger (use only manufactures wall charging
converter). Supports 16mm four-pin aviation plug for DC
charging (29.4V - 9A max). (1-2 positive / 3-4
negative)
8&9
AC Output Outlets (#8-9): When the AC button is used to turn
on the power station the AC outlets will provide Pure Sine
Wave AC current.
(no indication in manual what this port is for)
10
5

No.
Feature
10
LED Light Switch: Press to turn on / off the LED light.
11
LED Light: The working power of the LED light is 2W.
Caution: Do not look directly into the light when illuminated.
12&13
Air Vents: For proper ventilation, cooling and performance of
the power station do not block air vents. Maintain at least 1-2
feet of air space around the power station to allow continual air
flow.
10
11 12
13
PORTABLE POWER STATION
6

DC Output: When the DC power is turned on, the LCD screen will display
“DC OUT”. The USB ports and 12V DC socket will be active.
AC Output: When the AC power is turned on, the LCD screen will display
“AC OUT”. It will show the current charge of the battery and percentage
level (each bar represents 20%). The AC outlets will be active. When used -
The AC meter shows the percentage of the AC output of the current load
used. AC outlets will provide Pure Sine Wave 220V.
Battery Level: The display shows the current charge of the battery. Each
bar represents 20%. When charging - the bars will illuminate one bar at a
time. When the bars stop the battery is fully charged. When there is less
than 10% of charge remaining the battery icon will begin to flash. At this
point Please charge the power station immediately.
Battery % / Battery Voltage: The power station will reserve some power to
protect itself from over-discharging, even if the battery level drops to 0%.
When the power station is running devices that require high power
consumption, the low-voltage alarm will be displayed when the battery level
drops to 10%-20%. When this occurs, recharge the power station
immediately.
(Section 3.1) LCD Intelligence Display
Figure 4( intelligence display screen)
DC output power
Charge
Discharge
Time
Battery level
AC output power
AC output power
Battery percentage(%)/
Battery voltage(V)
Temperature Alarm
Charge/discharge power
AC output(W)/Voltage(V)
AC output overload alarm
PF value/charge and discharge time
PORTABLE POWER STATION
7

Temperature Alarm: When the temperature of the power station is too high,
all output power will be shut down. You will hear five “di” tones. The power
station will resume working when the temperature falls within its working
range.
Charging: When the power station is charging (AC/DC), the LCD
intelligence screen will display (image) icon.
Discharging: When DC devices are being operated the LCD intelligence
screen will display to indicate there is DC output current.(image) icon
Charge/Discharge Power: The screen will display the net value in Watts
of the input and output rate when the power station is being charged and
discharged at the same time.
AC Output Wattage/Voltage: When the AC output is on - the Wattage (W)
and Voltage (V) levels of the power being used will be displayed.
AC Overload Alarm: When the total AC output exceeds the rated power of
the power station (500W / 600W) the “Over Load” icon will flash (IMAGE)
and you will hear two “beep” tones. The power station will shut down all AC
output current.
PF Value / Charge and Discharge Time: PF (Power Factor) is the ratio of
the actual flow of current of the power station calculated in time whether
charging or discharging. The remaining charge or discharge time (in hours)
will be displayed.
PORTABLE POWER STATION
8

9
PORTABLE POWER STATION
When the DC button is activated
the LCD screen with show the
battery level and percentage
(each bar represents 20%),
estimated discharge time
remaining in hours and the
wattage load being used.
Quickly pressing the DC button
again will show the discharging
voltage. Press again to return
to the battery level.
To turn off - press and the DC
button for 2-3 seconds.
When the AC button is activated
the LCD screen with show the
battery level and percentage
(each bar represents 20%),
estimated discharge time
remaining in hours and the
wattage load being used.
To turn off - press the AC button
for 2-3 seconds.
Quickly pressing the AC
button a second time will
show the discharging
voltage and PF (power
factor) level as indicated
by the meter.
To turn off - press and the
AC button for 2-3 seconds.
DC Display Screen
AC Display Screen
AC Display Screen

4. Working Guidelines
Dry
Use and store the unit only in a cool and dry environment
Temperature
0 degree C / 45 degrees C for charging (32 F - 113 F)
-20 degree C / 45 degree C for discharging (-4 F - 113 F)
Ventilation
Keep the air vents at least 20cm (8 inches) away from any
objects to allow for proper air flow
Safety
Do not store, charge or use the unit in an area exposed to
flammable or corrosive gas
4.1 Charging:
Use only the Pecron original power adapter to charge the power station.
To charge - First, Plug the 4 prong aviation plug of the charging cable into
the DC “input” charging port labeled (29.4V 9A). Second plug the power
cable of the charger into the wall outlet. The red light on the charger will
illuminate and the fan will start. When the unit is 100% charged the charger
will continue delivering a small trickle charge. When the light on the charger
turns green the charge is complete. Unplug the charger from the wall outlet
first, then unplug the charging cord from the power station.
Do not leave the unit unattended while charging. Though the power
station can work with pass through charging it is recommended to not
have a load running on the power station while charging to prevent
overheating.
PORTABLE POWER STATION
10

Make sure to charge the power station every 6 months.
When you leave the power station unattended / unused for a period of
time, be sure to charge it fully to 100% before using.
4.2 AC Output
Operation Steps:
(1) Check the working power rating of your device and ensure it’s within the
P600 allowable output range. (You can get larger capacity power
stations from www.pecron.com - if P600 does not meet your needs).
(2) Turn on AC output by pressing the AC button for 1 second.
(3) Plug the device into the AC outlet. Then turn on or use your device.
(4) When finished turn off the device, disconnect it from AC outlet and turn
off the power station by depressing the AC button for 2-3 seconds.
(5) For longer battery life and maintenance, please recharge your P600
when the battery is running low. Best to recharge before reaching 20%
battery capacity. Disconnect all devices and recharge immediately if the
battery reaches 10% charge.
The P600 portable power station supports many devices. Always check
to make sure the power rating of your device is within the designated range
of the P600. Note that some appliances require extra power to start up. In
general, the starting power for different types of equipment (e.g. motors,
compressors, drill, fluorescent lamps, etc.) can require 3-8 times their rated
power level. For safety measures, the internal BMS will engage the over-
load protection and shut down all outputs if the total output load exceeds
the P600 working power.
11
PORTABLE POWER STATION

When the power station battery capacity has been run too low or the total
load capacity of any device exceeds the output rating of the P600 or the
temperature is too high, the power station will automatically turn itself off.
To restart - turn off all devices. Disconnect all devices from the power
station, allow the power station to cool down then restart and plug in one
device at a time - not exceeding the power range.
12
PORTABLE POWER STATION
5. Warranty
All Pecron products come with a 12-month warranty. The warranty
activates automatically from the date the power station is delivered.
(Please keep the purchase receipt as a proof of purchase for any warranty
claim.) Pecron warrants our products to be free from defects in
workmanship and materials under normal operating conditions and use.
We will not assume, nor authorize any person to assume for us, any other
liability in connection with the sale of Pecron products.
Pecron will repair or replace (at our discretion) any Pecron product that
fails to operate during the applicable warranty period due to defects in
workmanship or material. If a valid claim is made during the applicable
period, Pecron at its option will either (1) replace the product or (2)
exchange the product with a product that is the same or equal value. A
replacement product will assume the remaining warranty period of the
original product. Customer is responsible for the return shipping costs and
proper packaging.

Pecron warranty does not apply to the following situations, even if
it is within the warranty period.
* Altering or disassembly of the unit.
* Wear and tear on the outer surface
* Misuse or abuse for anything other than normal consumer use as
authorized in Pecron’s current product literature
* Breakdown or damage caused by natural hazards beyond our control
(fire, rain damage, water damage, sun exposure, etc)
* Warranty does not cover the packaging and accessories
For additional coverage, we offer paid service once the warranty expires.
Thank you for your purchase of our Pecron products. We hope you will
enjoy your unit and have years of active service.
PORTABLE POWER STATION
13

Certificate of Conformity
Warranty Card
Item and specifications:
Inspector:
Date of manufacture:
PORTABLE POWER STATION
ITEM: Name: Date of purchase:
Serial number: Customer: Tel:
Address: Invoice:
Distributor: Address:
Table of contents
Other Pecron Portable Generator manuals

Pecron
Pecron EB3000-24V User manual

Pecron
Pecron E3000 User manual

Pecron
Pecron P-II User manual

Pecron
Pecron S500 User manual

Pecron
Pecron E1000 User manual

Pecron
Pecron E600 LFP User manual

Pecron
Pecron H600 User manual

Pecron
Pecron P500 User manual

Pecron
Pecron E3000 User manual

Pecron
Pecron S500 User manual
Popular Portable Generator manuals by other brands

Mech Marvels
Mech Marvels MM2000I instruction manual

Fischer Panda
Fischer Panda 8000 NE user manual

Yamaha
Yamaha EF2000iS - Inverter Generator owner's manual

Raider
Raider Power Tools RD-GG11 user manual

Hyundai
Hyundai HY3600SEi operating instructions

SG GROUP
SG GROUP GENERGY LIMITED1000I Instructions for use