FOODSERVICE EV4331-31 SPECIFICATION SHEET
MONITORING SYSTEM FOR CLARIS FILTER CARTRIDGE SYSTEMS
Vending
Hotel
Restaurant
Cafe
The programming and display unit
provides the following information:
• Residual capacity of installed
filter cartridge
• Filtrate volume of the last five (5)
installed filter cartridges
• Operation time of the last five (5)
• Total filtrate volume since flow meter
installation
APPLICATIONS
FEATURES • BENEFITS
If mounting display to a wall, securely
connect the display to the wall using
suitable screws or mounting hardware.
Shut-off valve must be installed upstream
of the filter.
Refer to Installation, Operation &
Maintenance manual for flow meter start
up and programing.
Change Claris Cartridge when its
pre-calculated water volume has been
reached or at least once per year.
Change cartridges when capacity
is reached.
Operating Pressure: 29 - 116 psi (2 - 8 bar)
Flow Rate: 2.64 - 26.4 gph (10 -100 Lph)
INSTALLATION TIPS OPERATION TIPS
Claris Flow Meter: EV4339-31
EVERPURE®CLARIS FLOW METER
EV4339-31
SIZING
The CLARIS Flow Meter has been
developed specifically to monitor the
usage rate of the CLARIS Water Filter
System and to determine the optimum
cartridge replacement interval. After
setting the programming unit to monitor
the specific filter size, the Claris Flow
Meter continually measures the filtrate
volume to calculate and display the
remaining filtration capcity in liters.
Once the available filtration capacity is
exhausted or the maximum operation
time has been reached the display unit
indicates the filter cartridge replacement.
All Pentair trademarks and logos are owned by Pentair, Inc. or its affiliates. All other registered and unregistered trademarks and logos are the property of their
respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
Pentair is an equal opportunity employer.
© 2015 Pentair Filtration Solutions, LLC. All Rights Reserved.
WATER QUALITY SYSTEMS
EVERPURE-SHURFLO WORLD HEADQUARTERS, 1040 MUIRFIELD DRIVE, HANOVER PARK, IL 60133 USA • FOODSERVICE.PENTAIR.COM
800.942.1153 MAIN (US ONLY) • 630.307.3000 MAIN • 630.307.3030 FAX • CSEVERPURE@PENTAIR.COM EMAIL
EVERPURE-SHURFLO AUSTRALIA, 1-21 MONASH DRIVE, DANDENONG SOUTH, VIC 3175, AUSTRALIA
011.1300.576.190 TEL • 011.61.39.562.7237 FAX • AU.EVERPURE@PENTAIR.COM EMAIL
EVERPURE-SHURFLO CHINA, 21F CLOUD 9 PLAZA, NO 1118, SHANGHAI, 200052, CHINA
86.21.3211.4588 TEL • 86.21.3211.4580 FAX • [email protected] EMAIL
EVERPURE-SHURFLO INDIA, GREEN BOULEVARD, B-9/A, 7TH FLOOR - TOWER B SECTOR 62, NOIDA - 201301
91.120.419.9444 TEL • 91.120.419.9400 FAX • INDIACUSTOMER@PENTAIR.COM EMAIL
EVERPURE-SHURFLO EUROPE, PENTAIR WATER BELGIUM BVBA, INDUSTRIEPARK WOLFSTEE, TOEKOMSTLAAN, 30 B-2200 HERENTALS, BELGIUM
+32.(0).14.283.500 TEL • +32.(0).14.283.505 FAX • SALES@EVERPURE-EUROPE.COM EMAIL
EVERPURE-SHURFLO JAPAN INC., HASHIMOTO MN BLDG. 7F, 3-25-1 HASHIMOTO, MIDORI-KU, SAGAMIHARA-SHI KANAGAWA 252-0143, JAPAN
81.(0)42.775.3011 TEL • 81.(0)42.775.3015 FAX • INFO@EVERPURE.CO.JP EMAIL
EVERPURE-SHURFLO SOUTHEAST ASIA, SOUTHEAST ASIA, 390 HAVELOCK ROAD, #04-01, KING’S CENTRE, SINGAPORE 169662
65.6768.5800 TEL • 65.6737.5149 FAX • CSEVERPURE@PENTAIR.COM EMAIL
EV4339-31 JL15
SENSOR UNIT
Overall Dimensions
3.15" H x 1.81" W x 1.69" D
(8 cm x 4.5 cm x 4.2 cm)
Inlet Connection
3/8" BSP F Nut
Outlet Connection
3/8" BSP M
Operating Pressure
29 - 116 psi (2 - 8 bar)
Flow Rate
2.64 - 26.4 gph (10 - 100 Lph)
Pressure Loss up to 26.4 gph (100 Lph)
Flow Rate
3 psi (0.2 bar)
Precision (horizontal installation)
±5%
Water Temperature
39 – 86°F (4 – 30°C)
Ambient Temperature
39 – 104°F (4 – 40°C)
Installation Position
Horizontal recommended
SPECIFICATIONS
WARRANTY
Everpure Claris water treatment systems by Pentair®are covered by a limited
warranty against defects in material and workmanship for a period of one year
after date of purchase. Everpure replaceable elements (filter cartridges and water
treatment cartridges) are covered by a limited warranty against defects in material and
workmanship for a period of one year after date of purchase. See printed warranty for
details. Pentair will provide a copy of the warranty upon request.
EVERPURE®CLARIS FLOW METER
EV4339-31
PROGRAMMING AND DISPLAY UNIT
Overall Dimensions
1.97" H x 2.95" W x 67" L
(5 cm x 7.4 cm x 170.1cm)
Splash Proof
IPX4
Display 5 Digits
Counter 99999 - 9999 gallons
(Downwards 99999 - 9999 L)
Cable
59" (1.5 meters)
Claris™ is a trademark of Aquis, GmbH

Other Pentair Measuring Instrument manuals

Pentair HAFFMANS 006.625 User manual

Pentair

Pentair HAFFMANS 006.625 User manual

Pentair LINCOLN A Series Owner's manual

Pentair

Pentair LINCOLN A Series Owner's manual

Pentair GOYEN MECAIR PEM User manual

Pentair

Pentair GOYEN MECAIR PEM User manual

Pentair Point Four Tracker User manual

Pentair

Pentair Point Four Tracker User manual

Pentair HAFFMANS GMT User manual

Pentair

Pentair HAFFMANS GMT User manual

Pentair INTELLISYNC User manual

Pentair

Pentair INTELLISYNC User manual

Pentair HAFFMANS c-DGM User manual

Pentair

Pentair HAFFMANS c-DGM User manual

Pentair HAFFMANS RPU-352 User manual

Pentair

Pentair HAFFMANS RPU-352 User manual

Popular Measuring Instrument manuals by other brands

Proteus ATEX Zone 1 Original User Instruction Manual

Proteus

Proteus ATEX Zone 1 Original User Instruction Manual

HBM GEN series user manual

HBM

HBM GEN series user manual

PCB Piezotronics ICP J356A44 Installation and operating manual

PCB Piezotronics

PCB Piezotronics ICP J356A44 Installation and operating manual

JPT YDFLP Installation guide and user's manual

JPT

JPT YDFLP Installation guide and user's manual

Triplett GSM250 user manual

Triplett

Triplett GSM250 user manual

Michell Instruments Optidew Vision user guide

Michell Instruments

Michell Instruments Optidew Vision user guide

Metro DataVac MET200 user manual

Metro DataVac

Metro DataVac MET200 user manual

PCB Piezotronics X3501A2060KG Installation and operating manual

PCB Piezotronics

PCB Piezotronics X3501A2060KG Installation and operating manual

TRAMEX PROFESSIONAL PTM 2.0 user guide

TRAMEX

TRAMEX PROFESSIONAL PTM 2.0 user guide

PCB Piezotronics IMI SENSORS 66392CPZ1 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 66392CPZ1 Installation and operating manual

Mollet MSD-420 quick start guide

Mollet

Mollet MSD-420 quick start guide

Anritsu Field Master Pro MS2090A user guide

Anritsu

Anritsu Field Master Pro MS2090A user guide

ECP VARILUX X Series user guide

ECP

ECP VARILUX X Series user guide

Oceanic Systems NMEA2000 3410 user manual

Oceanic Systems

Oceanic Systems NMEA2000 3410 user manual

QED GA5000 operating manual

QED

QED GA5000 operating manual

HP 4262A Operating and service manual

HP

HP 4262A Operating and service manual

IPG Photonics YLR Series user guide

IPG Photonics

IPG Photonics YLR Series user guide

CT Lab Vecto III user manual

CT Lab

CT Lab Vecto III user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.